Permit #2021040901

Permit Details

Status: COED

Parcel Id: 07-11-31-7026-00640-0300
CONDITIONED SPACE: 1448 sqft
GARAGE: 415 sqft
OPENED PORCH (WITH ROOF) : 234 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
Total Square Footage: 2157 sqft
Block: 00640
Subdivision: 2153 - SECTION 26-PINE GROVE
Job Phone: 386-447-4151
Location Address: 21 PINELL LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/26/2021
NOC: RECORDED
Applicant name: GENE WARREN SLONE
Owner: FLORIDA GREEN CONSTRUCTION INC

Address

50 LEANNI WAY UNIT C1

PALM COAST, FL 32137

Lot: 0300
Contracted Stated Job Value: ¤200,000.00
Job Description: Single Family Home
Type: CN

Contractor

FLORIDA GREEN CONSTRUCTION INC.
Status Location Address State License Number Phone
INACTIVE

870 E RETTA STREET

DELEON SPRINGS, FL 32130

CBC1260957 (Exp: 08/31/2026) 407-580-2657

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
ERIC FRANCO
Status Location Address Mailing Address State License Number Phone
INACTIVE

840 DELTONA BLVD

DELTONA, FL 32725

STE F2

DELTONA, FL 32725

CCC1327280 (Exp: 08/31/2026) 386-575-4007
KERRY DWAIN AYLESWORTH II
Status Location Address Mailing Address State License Number Phone
ACTIVE

2820 LEWIS SPEEDWAY

ST AUGUSTINE, FL 32084

STE B

ST AUGUSTINE, FL 32084

CAC1820713 (Exp: 08/31/2026) 904-342-5709

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/04/2022 FINAL APPROVED KSANDOE
Note: 10/2/2022 12:30:43 PM- PREVIOUS INSPECTION NOTES Inspections requested for October 3rd and been rescheduled to October 4th. The Building Inspectors are working with the Utility Department pumping PEP tanks from homes that are currently without power. 9/22/2022 - PREVIOUS INSPECTION NOTES 9/20/2022 - PREVIOUS INSPECTION NOTES Dishwasher drain line needs to be rerouted. Dishwasher needs breaker lock in panel or power supply from adjacent cabinet 9/22/22 P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in tha tposition before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece.
BLD - BUILDING FINAL 10/03/2022 CANCELLED BY APPLICANT BBEMBRY
Note: Inspections requested for October 3rd and been rescheduled to October 4th. The Building Inspectors are working with the Utility Department pumping PEP tanks from homes that are currently without power. 9/22/2022 - PREVIOUS INSPECTION NOTES 9/20/2022 - PREVIOUS INSPECTION NOTES Dishwasher drain line needs to be rerouted. Dishwasher needs breaker lock in panel or power supply from adjacent cabinet 9/22/22 P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in tha tposition before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece.
BLD - BUILDING FINAL 09/22/2022 Disapproved - NO FEE KSANDOE
Note: 9/20/2022 - PREVIOUS INSPECTION NOTES Dishwasher drain line needs to be rerouted. Dishwasher needs breaker lock in panel or power supply from adjacent cabinet 9/22/22 P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in tha tposition before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece.
BLD - BUILDING FINAL 09/20/2022 Disapproved - NO FEE KSANDOE
Note: Dishwasher drain line needs to be rerouted. Dishwasher needs breaker lock in panel or power supply from adjacent cabinet
U-CROSS CONNECTION 08/01/2022 APPROVED - AS NOTED LFITZGERALD
Note: has potable irrigation with PVB installed NOTE-THERE IS AN IRRIGATION METER INSTALLED BUT NOT HOOKED UP TO ANYTHING/NOT INTENDING TO BE USE IN THE FUTURE-PLEASE CONTACT UTILITY DEPT. AT CUSTOMER-SERVICE@PALMCOASTGOV.COM TO GET REMOVED SO NEW HOMEONEWER DOES NOT INCURE A CHARGE.
U -UTILITY RESIDENTIAL FINAL 08/01/2022 Disapproved -FEE REQUIRED LFITZGERALD
Note: pep circuit breaker coupled with garage breaker-required to be on a single line
U -UTILITY RESIDENTIAL FINAL 08/01/2022 FINAL APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION pep circuit breaker coupled with garage breaker-required to be on a single line
ROW - STORMWATER FINAL 07/07/2022 APPROVED PFLANAGAN
Note: THIS IS A REINSPECTION NEED TO PICK UP TRASH WHERE THE PORTER JOHN WAS AND ADD NEW SOD WHERE THE PORTER JOHN WAS
ROW - STORMWATER FINAL 06/29/2022 Disapproved -FEE REQUIRED PFLANAGAN
Note: NEED TO PICK UP TRASH WHERE THE PORTER JOHN WAS AND ADD NEW SOD WHERE THE PORTER JOHN WAS
ELECTRIC - EARLY POWER 06/28/2022 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 1217. Release Power
FINAL SURVEY (OFFICE USE ONLY) 06/10/2022 APPROVED GBERTOLA
ROW FIELD SURVEY /GRADING CERTIFICATION 06/10/2022 APPROVED GBERTOLA
ROW - FINAL APRON (AFTER POUR) 06/10/2022 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
ROW- PRE-APRON (PRE-POUR) 03/30/2022 APPROVED RGROSS
Note: READY TO POUR
U - SEWER TIE IN 03/16/2022 APPROVED MGIBSON
GRAVITY SEWER TEST 03/16/2022 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 02/18/2022 APPROVED CSTONE
INSULATION 02/01/2022 APPROVED KSANDOE
LATH/BRICK/ WATER BARRIER 01/28/2022 APPROVED KSANDOE
ALL ROUGH 01/24/2022 APPROVED - AS NOTED KSANDOE
Note: Exterior garage junction boxes need to be grounded.
WALL SHEATHING 01/19/2022 APPROVED KSANDOE
ELECTRIC TEMP POLE 08/30/2021 APPROVED - AS NOTED JMUNSON
Note: Emailed FPL at 9:45 am
ROOF VALLEY & METAL 08/26/2021 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/24/2021 APPROVED - AS NOTED JWALKER
Note: THIS IS A REINSPECTION Missed nailing at roof sheating. Left side of garage., Right side of house front hip roof, Rear hip roof left side. Marked areas in black marker. Garage bearing wall 2x12 header is missing 2 LSTA 21 straps Front 6x6 column, the top calls for 4 MSTA 24 straps. Missing strong back and 2x4 blocking required at gable end walls Truss 11 and 9 are missing hold down anchors at block wall Missing engineering on Truss #2 All trusses landing on CMU wall need to have a moisture barrier / metal plate between truss and top of block wall Install blocking to carry load of the 2x ridge board at rear hip roof, both ends for contiuous load path. 8/24/21 Truss 9 still missing hold down anchor. Interior block wall. Check at all rough inspection.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/20/2021 Disapproved -FEE REQUIRED JWALKER
Note: Missed nailing at roof sheating. Left side of garage., Right side of house front hip roof, Rear hip roof left side. Marked areas in black marker. Garage bearing wall 2x12 header is missing 2 LSTA 21 straps Front 6x6 column, the top calls for 4 MSTA 24 straps. Missing strong back and 2x4 blocking required at gable end walls Truss 11 and 9 are missing hold down anchors at block wall Missing engineering on Truss #2 All trusses landing on CMU wall need to have a moisture barrier / metal plate between truss and top of block wall Install blocking to carry load of the 2x ridge board at rear hip roof, both ends for contiuous load path.
FOUND SURVEY APPROVED (OFFICE) 08/19/2021 APPROVED TBAKER
TIE BEAM / LINTEL 08/02/2021 APPROVED JWALKER
MONOLITHIC SLAB 07/06/2021 APPROVED JWALKER
PLUMBING 1ST ROUGH UNDERGROUND 06/22/2021 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 05/13/2021 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 09/15/2022 09/16/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 09/14/2022 09/14/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder per 107.1 FBC Residential 2020 7th edition
CUSVC COMPLETE 03/11/2022 03/16/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ENGIN1 COMPLETE 08/19/2021 08/19/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 08/19/2021 08/19/2021
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SWALE COMPLETE 04/16/2021 07/13/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 04/15/2021 04/21/2021
Note: Released By: JPI
CUSVC COMPLETE 04/15/2021 04/21/2021
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 04/15/2021 04/19/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/15/2021 04/16/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 04/15/2021 04/22/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 04/15/2021 04/16/2021
Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 04/15/2021 04/22/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
ZON COMPLETE 04/15/2021 04/20/2021
Note: Released By: ESTELLE LENS - (386)986-2655 -

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 09/19/2022
REINSPECTION FEE ¤40.00 09/19/2022
SW ENG REINSPECTION 20 ¤20.00 09/19/2022
PLAN REVIEW - REVISION ¤32.50 09/19/2022
REINSPECTION RESIDENTIAL ¤40.00 09/19/2022
CONNECTION FEES ¤1,017.83 04/26/2021
STORM WATER PERMIT FEES ¤80.00 04/26/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 04/26/2021
SEWER CREDIT (¤1,147.00) 04/26/2021
SEWER INSPECTION ¤25.00 04/26/2021
SEWER CAPITAL FACILITY ¤4,664.55 04/26/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 04/26/2021
NEW RESIDENTIAL INSPECTIONS ¤400.00 04/26/2021
SITE PLAN 20 ¤20.00 04/26/2021
SURCHARGE FS 533.721 ¤2.00 04/26/2021
SURCHARGE - FS 468.631 ¤2.00 04/26/2021
METER - DEPOSIT ¤60.00 04/26/2021
METER - DEPOSIT ¤60.00 04/26/2021
WATER-METER ¤441.07 04/26/2021
WATER- TURN ON ¤25.00 04/26/2021
WATER- TURN ON ¤25.00 04/26/2021
ADMIN FEE ¤20.00 04/26/2021
BUILDING DISCOUNT 100% (¤1,040.00) 04/26/2021
ELECTRIC FEE ¤180.00 04/26/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 04/26/2021
IMPACT FEE FIRE ¤367.00 04/26/2021
IMPACT FEE PARKS ¤1,199.12 04/26/2021
IMPACT FEE SCHOOL ¤3,600.00 04/26/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 04/26/2021
MECHANICAL FEE ¤180.00 04/26/2021
WATER -IRRIGATION INSPECTION ¤25.00 04/26/2021
WATER -IRRIGATION INSPECTION ¤25.00 04/26/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 04/26/2021
PLAN CHECK FEE ¤80.00 04/26/2021
PLUMBING FEE ¤180.00 04/26/2021
Fees Total Due: ¤0.00 Total Paid: ¤15,708.00