I want to search for...
Permit #2021040901
Permit Details
Status: COED
| Parcel Id: 07-11-31-7026-00640-0300 |
| CONDITIONED SPACE: 1448 sqft |
| GARAGE: 415 sqft |
| OPENED PORCH (WITH ROOF) : 234 sqft |
| OPENED PORCH (WITH ROOF) : 60 sqft |
| Total Square Footage: 2157 sqft |
| Block: 00640 |
| Subdivision: 2153 - SECTION 26-PINE GROVE |
| Job Phone: 386-447-4151 |
| Location Address: 21 PINELL LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/26/2021 |
| NOC: RECORDED |
| Applicant name: GENE WARREN SLONE |
| Owner: FLORIDA GREEN CONSTRUCTION INC |
|
Address 50 LEANNI WAY UNIT C1 PALM COAST, FL 32137 |
| Lot: 0300 |
| Contracted Stated Job Value: ¤200,000.00 |
| Job Description: Single Family Home |
| Type: CN |
Contractor
FLORIDA GREEN CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone |
| INACTIVE |
870 E RETTA STREET DELEON SPRINGS, FL 32130 |
CBC1260957 (Exp: 08/31/2026) | 407-580-2657 |
Sub Contractors
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
ERIC FRANCO
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
840 DELTONA BLVD DELTONA, FL 32725 |
STE F2 DELTONA, FL 32725 |
CCC1327280 (Exp: 08/31/2026) | 386-575-4007 |
KERRY DWAIN AYLESWORTH II
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
2820 LEWIS SPEEDWAY ST AUGUSTINE, FL 32084 |
STE B ST AUGUSTINE, FL 32084 |
CAC1820713 (Exp: 08/31/2026) | 904-342-5709 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/04/2022 | FINAL APPROVED | KSANDOE |
| Note: 10/2/2022 12:30:43 PM- PREVIOUS INSPECTION NOTES Inspections requested for October 3rd and been rescheduled to October 4th. The Building Inspectors are working with the Utility Department pumping PEP tanks from homes that are currently without power. 9/22/2022 - PREVIOUS INSPECTION NOTES 9/20/2022 - PREVIOUS INSPECTION NOTES Dishwasher drain line needs to be rerouted. Dishwasher needs breaker lock in panel or power supply from adjacent cabinet 9/22/22 P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in tha tposition before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece. | |||
| BLD - BUILDING FINAL | 10/03/2022 | CANCELLED BY APPLICANT | BBEMBRY |
| Note: Inspections requested for October 3rd and been rescheduled to October 4th. The Building Inspectors are working with the Utility Department pumping PEP tanks from homes that are currently without power. 9/22/2022 - PREVIOUS INSPECTION NOTES 9/20/2022 - PREVIOUS INSPECTION NOTES Dishwasher drain line needs to be rerouted. Dishwasher needs breaker lock in panel or power supply from adjacent cabinet 9/22/22 P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in tha tposition before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece. | |||
| BLD - BUILDING FINAL | 09/22/2022 | Disapproved - NO FEE | KSANDOE |
| Note: 9/20/2022 - PREVIOUS INSPECTION NOTES Dishwasher drain line needs to be rerouted. Dishwasher needs breaker lock in panel or power supply from adjacent cabinet 9/22/22 P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in tha tposition before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece. | |||
| BLD - BUILDING FINAL | 09/20/2022 | Disapproved - NO FEE | KSANDOE |
| Note: Dishwasher drain line needs to be rerouted. Dishwasher needs breaker lock in panel or power supply from adjacent cabinet | |||
| U-CROSS CONNECTION | 08/01/2022 | APPROVED - AS NOTED | LFITZGERALD |
| Note: has potable irrigation with PVB installed NOTE-THERE IS AN IRRIGATION METER INSTALLED BUT NOT HOOKED UP TO ANYTHING/NOT INTENDING TO BE USE IN THE FUTURE-PLEASE CONTACT UTILITY DEPT. AT CUSTOMER-SERVICE@PALMCOASTGOV.COM TO GET REMOVED SO NEW HOMEONEWER DOES NOT INCURE A CHARGE. | |||
| U -UTILITY RESIDENTIAL FINAL | 08/01/2022 | Disapproved -FEE REQUIRED | LFITZGERALD |
| Note: pep circuit breaker coupled with garage breaker-required to be on a single line | |||
| U -UTILITY RESIDENTIAL FINAL | 08/01/2022 | FINAL APPROVED | LFITZGERALD |
| Note: THIS IS A REINSPECTION pep circuit breaker coupled with garage breaker-required to be on a single line | |||
| ROW - STORMWATER FINAL | 07/07/2022 | APPROVED | PFLANAGAN |
| Note: THIS IS A REINSPECTION NEED TO PICK UP TRASH WHERE THE PORTER JOHN WAS AND ADD NEW SOD WHERE THE PORTER JOHN WAS | |||
| ROW - STORMWATER FINAL | 06/29/2022 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: NEED TO PICK UP TRASH WHERE THE PORTER JOHN WAS AND ADD NEW SOD WHERE THE PORTER JOHN WAS | |||
| ELECTRIC - EARLY POWER | 06/28/2022 | APPROVED - AS NOTED | KSANDOE |
| Note: Emailed FPL @ 1217. Release Power | |||
| FINAL SURVEY (OFFICE USE ONLY) | 06/10/2022 | APPROVED | GBERTOLA |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/10/2022 | APPROVED | GBERTOLA |
| ROW - FINAL APRON (AFTER POUR) | 06/10/2022 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD | |||
| ROW- PRE-APRON (PRE-POUR) | 03/30/2022 | APPROVED | RGROSS |
| Note: READY TO POUR | |||
| U - SEWER TIE IN | 03/16/2022 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 03/16/2022 | APPROVED | MGIBSON |
| PEP TANK INSTALLATION REQUEST | 02/18/2022 | APPROVED | CSTONE |
| INSULATION | 02/01/2022 | APPROVED | KSANDOE |
| LATH/BRICK/ WATER BARRIER | 01/28/2022 | APPROVED | KSANDOE |
| ALL ROUGH | 01/24/2022 | APPROVED - AS NOTED | KSANDOE |
| Note: Exterior garage junction boxes need to be grounded. | |||
| WALL SHEATHING | 01/19/2022 | APPROVED | KSANDOE |
| ELECTRIC TEMP POLE | 08/30/2021 | APPROVED - AS NOTED | JMUNSON |
| Note: Emailed FPL at 9:45 am | |||
| ROOF VALLEY & METAL | 08/26/2021 | APPROVED | JWALKER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/24/2021 | APPROVED - AS NOTED | JWALKER |
| Note: THIS IS A REINSPECTION Missed nailing at roof sheating. Left side of garage., Right side of house front hip roof, Rear hip roof left side. Marked areas in black marker. Garage bearing wall 2x12 header is missing 2 LSTA 21 straps Front 6x6 column, the top calls for 4 MSTA 24 straps. Missing strong back and 2x4 blocking required at gable end walls Truss 11 and 9 are missing hold down anchors at block wall Missing engineering on Truss #2 All trusses landing on CMU wall need to have a moisture barrier / metal plate between truss and top of block wall Install blocking to carry load of the 2x ridge board at rear hip roof, both ends for contiuous load path. 8/24/21 Truss 9 still missing hold down anchor. Interior block wall. Check at all rough inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/20/2021 | Disapproved -FEE REQUIRED | JWALKER |
| Note: Missed nailing at roof sheating. Left side of garage., Right side of house front hip roof, Rear hip roof left side. Marked areas in black marker. Garage bearing wall 2x12 header is missing 2 LSTA 21 straps Front 6x6 column, the top calls for 4 MSTA 24 straps. Missing strong back and 2x4 blocking required at gable end walls Truss 11 and 9 are missing hold down anchors at block wall Missing engineering on Truss #2 All trusses landing on CMU wall need to have a moisture barrier / metal plate between truss and top of block wall Install blocking to carry load of the 2x ridge board at rear hip roof, both ends for contiuous load path. | |||
| FOUND SURVEY APPROVED (OFFICE) | 08/19/2021 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 08/02/2021 | APPROVED | JWALKER |
| MONOLITHIC SLAB | 07/06/2021 | APPROVED | JWALKER |
| PLUMBING 1ST ROUGH UNDERGROUND | 06/22/2021 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 05/13/2021 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 09/15/2022 | 09/16/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 09/14/2022 | 09/14/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder per 107.1 FBC Residential 2020 7th edition | |||
| CUSVC | COMPLETE | 03/11/2022 | 03/16/2022 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/19/2021 | 08/19/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/19/2021 | 08/19/2021 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 04/16/2021 | 07/13/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/15/2021 | 04/21/2021 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 04/15/2021 | 04/21/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 04/15/2021 | 04/19/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/15/2021 | 04/16/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 04/15/2021 | 04/22/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/15/2021 | 04/16/2021 |
| Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/15/2021 | 04/22/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/15/2021 | 04/20/2021 |
| Note: Released By: ESTELLE LENS - (386)986-2655 - |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 09/19/2022 |
| REINSPECTION FEE | ¤40.00 | 09/19/2022 |
| SW ENG REINSPECTION 20 | ¤20.00 | 09/19/2022 |
| PLAN REVIEW - REVISION | ¤32.50 | 09/19/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/19/2022 |
| CONNECTION FEES | ¤1,017.83 | 04/26/2021 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/26/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 04/26/2021 |
| SEWER CREDIT | (¤1,147.00) | 04/26/2021 |
| SEWER INSPECTION | ¤25.00 | 04/26/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 04/26/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 04/26/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤400.00 | 04/26/2021 |
| SITE PLAN 20 | ¤20.00 | 04/26/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/26/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/26/2021 |
| METER - DEPOSIT | ¤60.00 | 04/26/2021 |
| METER - DEPOSIT | ¤60.00 | 04/26/2021 |
| WATER-METER | ¤441.07 | 04/26/2021 |
| WATER- TURN ON | ¤25.00 | 04/26/2021 |
| WATER- TURN ON | ¤25.00 | 04/26/2021 |
| ADMIN FEE | ¤20.00 | 04/26/2021 |
| BUILDING DISCOUNT 100% | (¤1,040.00) | 04/26/2021 |
| ELECTRIC FEE | ¤180.00 | 04/26/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 04/26/2021 |
| IMPACT FEE FIRE | ¤367.00 | 04/26/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 04/26/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 04/26/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 04/26/2021 |
| MECHANICAL FEE | ¤180.00 | 04/26/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/26/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/26/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 04/26/2021 |
| PLAN CHECK FEE | ¤80.00 | 04/26/2021 |
| PLUMBING FEE | ¤180.00 | 04/26/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,708.00 |