I want to search for...

Permit #2021041204

Permit Details

Status: COED

Parcel Id: 07-11-31-7060-00120-0110
CONDITIONED SPACE: 1246 sqft
GARAGE: 404 sqft
OPENED PORCH (WITH ROOF) : 100 sqft
OPENED PORCH (WITH ROOF) : 54 sqft
Total Square Footage: 1804 sqft
Block: 00120
Subdivision: -
Job Phone: 321-249-3126
Location Address: 20 SLIPPER ORCHID TR E
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/13/2021
NOC: RECORDED
Applicant name: MOREY C DOYLE
Owner: WJHFL LLC

Address

3091 GOVERNORS LAKE DR

NORCROSS, GA 30071

Address

STE 300

NORCROSS, GA 30071

Lot: 0110
Contracted Stated Job Value: ¤87,220.00
Job Description: SINGLE FAMILY HOME
Type: CN

Contractor

WADE JURNEY HOMES
Status Location Address State License Number Phone
CANCEL

3091 GOVERNORS LAKE DRIVE

NORCROSS, GA 30071

CGC1517458 (Exp: 08/31/2022) 321-249-3126

Sub Contractors

EDWIN R INSALACO
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

3191 MAGUIRE BLVD

ORLANDO, FL 32803

STE 200

ORLANDO, FL 32803

EC13001310 (Exp: 08/31/2024) 321-441-7990 407-426-9741
MICHAEL LEE RAFFENSBERGER
Status Location Address State License Number Phone Fax
CANCEL

7725 SANDSCOVE CT

WINTER PARK, FL 32792

CAC1819723 (Exp: 08/31/2024) 407-629-6920 407-629-9307
DANIEL P GREGOIRE
Status Location Address State License Number Phone
INACTIVE

64 W. CENTRAL AVENUE

LAKE WALES, FL 33853

CFC057378 (Exp: 08/31/2024) (863)696-3737
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 11/05/2021 APPROVED - AS NOTED GBERTOLA
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION *Clean Culvert ends. *Repair washout on the right top mitered end. A washout occurred on the right side where the mitered end meets the edge of driveway. 11/3/21 - *Clean Culvert ends. *Repair washout on the right top mitered end. A washout occurred on the right side where the mitered end meets the edge of driveway. 11/05/20221= CORRECTION WERE MADE
ROW - FINAL APRON (AFTER POUR) 11/03/2021 Disapproved -FEE REQUIRED RGROSS
Note: THIS IS A REINSPECTION *Clean Culvert ends. *Repair washout on the right top mitered end. A washout occurred on the right side where the mitered end meets the edge of driveway. 11/3/21 - *Clean Culvert ends. *Repair washout on the right top mitered end. A washout occurred on the right side where the mitered end meets the edge of driveway.
ROW - STORMWATER FINAL 11/03/2021 APPROVED RGROSS
Note: THIS IS A REINSPECTION *Regrade and re-sod the swale across the street to match existing surrounding grade. Repair very large ruts. *Pick up all trash in swale across the street that fell out of the dumpster. *Repair road edge damage where dumpster was pulled out. See paint marks.
U -UTILITY RESIDENTIAL FINAL 10/20/2021 FINAL APPROVED JHARDING
ROW - FINAL APRON (AFTER POUR) 10/20/2021 Disapproved - NO FEE RGROSS
Note: *Clean Culvert ends. *Repair washout on the right top mitered end. A washout occurred on the right side where the mitered end meets the edge of driveway.
ROW - STORMWATER FINAL 10/20/2021 Disapproved -FEE REQUIRED RGROSS
Note: *Regrade and re-sod the swale across the street to match existing surrounding grade. Repair very large ruts. *Pick up all trash in swale across the street that fell out of the dumpster. *Repair road edge damage where dumpster was pulled out. See paint marks. Photo's Attached.
ROW FIELD SURVEY /GRADING CERTIFICATION 10/19/2021 APPROVED RGROSS
FINAL SURVEY (OFFICE USE ONLY) 10/19/2021 APPROVED RGROSS
PLUMBING FINAL 10/18/2021 Approval - Private Provider PPROVIDER
Note: THIS IS A REINSPECTION ADDED ON 10/13/2021 10:55:49 AM
HVAC FINAL 10/18/2021 Approval - Private Provider PPROVIDER
Note: THIS IS A REINSPECTION ADDED ON 10/13/2021 10:54:43 AM
ELECTRIC FINAL 10/18/2021 Approval - Private Provider PPROVIDER
Note: THIS IS A REINSPECTION ADDED ON 10/13/2021 10:54:27 AM
BLD - BUILDING FINAL 10/18/2021 Approval - Private Provider PPROVIDER
PLUMBING FINAL 10/13/2021 Disapproved- Private Provider PPROVIDER
ELECTRIC FINAL 10/13/2021 Disapproved- Private Provider PPROVIDER
HVAC FINAL 10/13/2021 Disapproved- Private Provider PPROVIDER
U-CROSS CONNECTION 10/11/2021 APPROVED - AS NOTED JHARDING
Note: No irrigation, no cross connections.
ROW- PRE-APRON (PRE-POUR) 09/24/2021 APPROVED - AS NOTED RGROSS
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION NEED TO REMOVE THE DIRT INSIDE THE CULVERT PIPE, PUMP THE WATER OUT. AT LEAST 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. 9/14/21 - *Culvert Full of Water *Missing the face board. Possibly hit by a car. *Not 6 inches thick at the Road edge. *Not 4 inches thick across the entrance of the garage or porch. *Left side bottom back miter board cannot be up against pipe. Move back 6 - 10 inches away from culvert. 9/24/21 - READY TO POUR
ROW- PRE-APRON (PRE-POUR) 09/17/2021 CANCELLED BY APPLICANT RGROSS
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION NEED TO REMOVE THE DIRT INSIDE THE CULVERT PIPE, PUMP THE WATER OUT. AT LEAST 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. 9/14/21 - *Culvert Full of Water *Missing the face board. Possibly hit by a car. *Not 6 inches thick at the Road edge. *Not 4 inches thick across the entrance of the garage or porch. *Left side bottom back miter board cannot be up against pipe. Move back 6 - 10 inches away from culvert.
ROW- PRE-APRON (PRE-POUR) 09/14/2021 Disapproved -FEE REQUIRED RGROSS
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION NEED TO REMOVE THE DIRT INSIDE THE CULVERT PIPE, PUMP THE WATER OUT. AT LEAST 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. 9/14/21 - *Culvert Full of Water *Missing the face board. Possibly hit by a car. *Not 6 inches thick at the Road edge. *Not 4 inches thick across the entrance of the garage or porch. *Left side bottom back miter board cannot be up against pipe. Move back 6 - 10 inches away from culvert.
ROW- PRE-APRON (PRE-POUR) 09/09/2021 CANCELLED BY APPLICANT GBERTOLA
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION NEED TO REMOVE THE DIRT INSIDE THE CULVERT PIPE, PUMP THE WATER OUT. AT LEAST 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE.
GRAVITY SEWER TEST 09/09/2021 Approval - Private Provider PPROVIDER
ROW- PRE-APRON (PRE-POUR) 09/08/2021 CANCELLED BY APPLICANT GBERTOLA
Note: THIS IS A REINSPECTION NEED TO REMOVE THE DIRT INSIDE THE CULVERT PIPE, PUMP THE WATER OUT. AT LEAST 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE.
ROW- PRE-APRON (PRE-POUR) 09/07/2021 Disapproved -FEE REQUIRED GBERTOLA
Note: NEED TO REMOVE THE DIRT INSIDE THE CULVERT PIPE, PUMP THE WATER OUT. AT LEAST 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE.
ELECTRIC - EARLY POWER 09/07/2021 Approval - Private Provider PPROVIDER
U - SEWER TIE IN 09/07/2021 APPROVED JGIBSON
INSULATION 08/09/2021 Approval - Private Provider PPROVIDER
ALL ROUGH 08/02/2021 Approval - Private Provider PPROVIDER
LATH/BRICK/ WATER BARRIER 08/02/2021 Approval - Private Provider PPROVIDER
PEP TANK INSTALLATION REQUEST 07/29/2021 APPROVED CSTONE
ALL ROUGH 07/28/2021 Approval - Private Provider PPROVIDER
LATH/BRICK/ WATER BARRIER 07/28/2021 Approval - Private Provider PPROVIDER
WALL SHEATHING 07/14/2021 Approval - Private Provider PPROVIDER
Note: 07/14/2021 Wall sheathing inspection passed.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/14/2021 Approval - Private Provider PPROVIDER
Note: 07/14/2021 Roof sheathing, braces and ties inspection passed.
ROOF VALLEY & METAL 07/12/2021 Approval - Private Provider PPROVIDER
ROOF VALLEY & METAL 07/07/2021 Approval - Private Provider PPROVIDER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/07/2021 Approval - Private Provider PPROVIDER
TIE BEAM / LINTEL 06/23/2021 Approval - Private Provider PPROVIDER
Note: 06/23/2021 Lintel inspection passed.
FOUND SURVEY APPROVED (OFFICE) 06/22/2021 APPROVED TBAKER
TIE BEAM / LINTEL 06/21/2021 Approval - Private Provider PPROVIDER
MONOLITHIC SLAB 06/07/2021 Approval - Private Provider PPROVIDER
PLUMBING 1ST ROUGH UNDERGROUND 06/02/2021 PPROVIDER
WATER METER INSTALLATION REQUEST 05/19/2021 APPROVED CSTONE

Review History

Department Status Date In Date Out
ZON COMPLETE 06/22/2021 06/22/2021
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/22/2021 06/22/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/19/2021 05/19/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 05/19/2021 05/19/2021
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM A site plan was submitted today for review with no notes as to what the changes are from the one that was approved on 5/11/21.
SW1 COMPLETE 05/19/2021 05/25/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
ZON COMPLETE 05/11/2021 05/13/2021
Note: Released By: ESTELLE LENS - (386)986-3751 -
MECH COMPLETE 04/29/2021 04/29/2021
Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM
ZON HOLD 04/29/2021 04/30/2021
Note: Held By: ESTELLE LENS - (386)986-2655 - Repeat comments: Need to fix FEMA map panel number. (...024OE) Banding is required on windows and doors in the rear facing the public right of way.
CUSVC COMPLETE 04/29/2021 05/05/2021
Note: Released By: HALEIGH HAND - -
BLD COMPLETE 04/21/2021 04/26/2021
Note: Released By: JPI
CUSVC HOLD 04/21/2021 04/27/2021
Note: Held By: HALEIGH HAND - - Please correct the utility application to reflect the correct parcel number.
ELEC COMPLETE 04/21/2021 04/22/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/21/2021 04/21/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 04/21/2021 04/26/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 04/21/2021 04/22/2021
Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder
SW1 COMPLETE 04/21/2021 04/27/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
ZON HOLD 04/21/2021 04/22/2021
Note: Held By: ESTELLE LENS - (386)986-2655 - Need to fix FEMA map panel number. (...024OE) Banding is required on windows and doors in the rear facing the public right of way.
SWALE COMPLETE 04/21/2021 07/19/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG REINSPECTION 20 ¤20.00 11/05/2021
SW ENG REINSPECTION 30 ¤30.00 10/29/2021
SW ENG REINSPECTION 30 ¤30.00 10/29/2021
SW ENG - FIELD SURVEY INSPECT ¤20.00 10/29/2021
SW ENG REINSPECTION 20 ¤20.00 10/29/2021
STORM WATER PERMIT FEES ¤80.00 05/13/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 05/13/2021
SEWER CREDIT (¤2,465.75) 05/13/2021
SEWER INSPECTION ¤25.00 05/13/2021
SEWER CAPITAL FACILITY ¤4,664.55 05/13/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 05/13/2021
METER - DEPOSIT ¤60.00 05/13/2021
WATER- TURN ON ¤25.00 05/13/2021
ADMIN FEE ¤20.00 05/13/2021
CONNECTION FEES ¤1,017.83 05/13/2021
BUILDING DISCOUNT 100% (¤20.00) 05/13/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 05/13/2021
IMPACT FEE FIRE ¤367.00 05/13/2021
IMPACT FEE PARKS ¤1,199.12 05/13/2021
IMPACT FEE SCHOOL ¤3,600.00 05/13/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 05/13/2021
WATER -IRRIGATION INSPECTION ¤25.00 05/13/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 05/13/2021
SITE PLAN 20 ¤20.00 05/13/2021
SURCHARGE FS 533.721 ¤2.00 05/13/2021
SURCHARGE - FS 468.631 ¤2.00 05/13/2021
Fees Total Due: ¤0.00 Total Paid: ¤13,785.68