I want to search for...

Permit #2021050090

Permit Details

Status: COED

Parcel Id: 03-12-31-0000-01010-0120
Total Square Footage: 22725 sqft
Block: 01010
Subdivision: -
Job Phone: 407-448-9300
Location Address: 6372 STATE HWY 100 E
Type: BC - BUILDING COMMERCIAL
Issue Date: 09/27/2021
NOC: RECORDED
Applicant name: GARY WAYNE BRIDGES
Owner: BELLA CITA STORAGE LLC

Address

880 BAY ROAD

MOUNT DORA, FL 32757

Lot: 0120
Contracted Stated Job Value: ¤989,000.00
Job Description: Building E -Self Storage Facility
Type: CN

Contractor

G&M CONSTRUCTION SERVICES, INC.
Status Location Address State License Number Phone
INACTIVE

PO BOX 2316

ORLANDO, FL 32804

CGC062542 (Exp: 08/31/2022) 407-448-9300

Sub Contractors

THOMAS ERIC SWORD
Status Location Address State License Number Phone
CANCEL

10330 PLEASANT VIEW DR

LEESBURG, FL 34788

CAC1814523 (Exp: 08/31/2022) 352-434-7550
MATTHEW JAMES BLANCHARD
Status Location Address State License Number Phone
INACTIVE

PO BOX 932

MT. DORA, FL 32757

EC13009373 (Exp: 08/31/2022) 352-383-4868
JOHN CHARLES GRAY
Status Location Address State License Number Phone Fax
ACTIVE

2707 ANNETTE STREET

FLAGLER BEACH, FL 32136

CFC1425975 (Exp: 08/31/2026) (386)793-3690 (386)439-7585

Inspection History

Type Request Date Result Inspector
BUILDING FINAL 07/01/2022 FINAL APPROVED DCUSHING
FIRE FINAL 07/01/2022 APPROVED JMUNSON
U - UTILITY COMMERCIAL FINAL 07/01/2022 APPROVED JHARDING
FOUNDATION SURVEY - OFFICE USE ONLY 06/30/2022 APPROVED DLEAP
PLUMBING FINAL 06/23/2022 CANCELLED BY INSPECTOR MGIBSON
Note: NO PLUMBING TO INSPECT
ELECTRIC - EARLY POWER 06/23/2022 APPROVED - AS NOTED RMARTIN
Note: emailed fpl released power 3:30
FIREWALL FRAMING 06/23/2022 APPROVED DCUSHING
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Framing are not placed per approved plans (supports are not located at perlins per plans) 3-9-22 ok mto place firs layer of drywall up to 8 foot
FIREWALL FINAL 06/23/2022 FINAL APPROVED DCUSHING
EXTERIOR ARCHITECTURAL FEATURES 06/21/2022 APPROVED JHARDING
FIREWALL PENETRATIONS 06/13/2022 APPROVED DCUSHING
ELECTRIC FINAL 06/07/2022 APPROVED RMARTIN
FIREWALL DRYWALL NAILING 04/29/2022 APPROVED - AS NOTED DCUSHING
Note: Fire Caulk and Rock Wool @ cutouts as discussed w/ super
HVAC ROUGH 04/28/2022 APPROVED CPISCITELLI
HVAC FINAL 04/28/2022 FINAL APPROVED CPISCITELLI
FIREWALL FRAMING 03/09/2022 PARTIALLY APPROVED LMILLER
Note: THIS IS A REINSPECTION Framing are not placed per approved plans (supports are not located at perlins per plans) 3-9-22 ok mto place firs layer of drywall up to 8 foot
FIREWALL FRAMING 02/24/2022 Disapproved - NO FEE LMILLER
Note: Framing are not placed per approved plans (supports are not located at perlins per plans)
LATH/BRICK/WATER BARRIER 01/18/2022 APPROVED LMILLER
Note: endwalls only
EXTERIOR WALL SHEATHING / SHEARWALL 01/11/2022 PARTIALLY APPROVED LMILLER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION end wall panels only call back in for DesGlass screw off inspeection 01-10-21... lath was placed on west end prior to inspection og densglass screw off inspection ( need to uncover work for inspection) east end ok to place lath, 01-11-21... OK to place Lathe at east and west ends.
EXTERIOR WALL SHEATHING / SHEARWALL 01/10/2022 PARTIALLY APPROVED LMILLER
Note: THIS IS A REINSPECTION end wall panels only call back in for DesGlass screw off inspeection 01-10-21... lath was placed on west end prior to inspection og densglass screw off inspection ( need to uncover work for inspection) east end ok to place lath,
EXTERIOR WALL SHEATHING / SHEARWALL 12/22/2021 PARTIALLY APPROVED LMILLER
Note: end wall panels only call back in for DesGlass screw off inspeection
MONOLITHIC SLAB 11/01/2021 APPROVED JWALKER
Note: THIS IS A REINSPECTION minimum clearance on steel from earth on reinfrcing bars not met
FOOTER 10/27/2021 Disapproved - NO FEE LMILLER
Note: minimum clearance on steel from earth on reinfrcing bars not met
MONOLITHIC SLAB 10/27/2021 Disapproved - NO FEE LMILLER
Note: minimum clearance on steel from earth on reinfrcing bars not met
ELECTRIC UNDERGROUND 10/15/2021 APPROVED RMARTIN
ELECTRIC - EARLY POWER 10/15/2021 CANCELLED BY APPLICANT WEB

Review History

Department Status Date In Date Out
BADMIN INFORMATION 06/30/2022 06/30/2022
Note: Marked INFORMATION By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM PLEASE RESUBMIT A SIGNED AND SEALED OR DIGITALLY FOUNDATION SURVEY AND NAME IT FOUNDATION NOT SURVEY
PLENG COMPLETE 06/30/2022 06/30/2022
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
MECH COMPLETE 09/23/2021 09/27/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 09/21/2021 09/23/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Upload digitally signed page M700
ELEC COMPLETE 09/21/2021 09/21/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 09/21/2021 09/22/2021
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
ARCHR COMPLETE 09/21/2021 09/22/2021
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
ARCHR COMPLETE 06/23/2021 06/24/2021
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
UD1 COMPLETE 06/23/2021 06/29/2021
Note: Released By: CHRIS JOHNSON - - CJOHNSON@PALMCOASTGOV.COM
ELEC HOLD 06/23/2021 06/28/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Reference the 2020 Energy code 2nd request
MECH HOLD 06/23/2021 06/23/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. All codes need to reference 2020 7Th edition- FBC Mechanical, FBC Energy Conservation, and FBC Accessibility 2. Ventialtion calculation needs to reference 2020 7Th edition FBC Mechanical 3. Provide heatload calculation per C403.2.1 FBC Energy Conservation 2020 7th edition (Second Request)
BLD COMPLETE 06/23/2021 07/07/2021
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
ARCHR HOLD 05/03/2021 05/06/2021
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM Provide color elevation renderings approved with the DO to note colors being used on the walls.
BLD HOLD 05/03/2021 05/17/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building 1. Provide complete copy of Geotechnical Investigation Report signed and sealed by a Florida licensed professional engineer. It appears a geotechnical investigation report was not included with the civil plans under the Commercial Site Development Permit. 2. Design professional in responsible charge to fill in steel building design engineer’s “approval’ certification box and sign and date on each plan sheet. As an alternative, these plan sheets can be provided at a later date as a deferred submittal in accordance with FBC-Building Section 107.3.4.1. If requesting these plan sheets to be a deferred submittal, approval blocks will still need to be signed and dated before they are submitted to the Building Department for review and approval and Architectural cover sheet will have to be noted in some manner indicating steel building plans will be provided at a later date as a deferred submittal per Section 107.3.4.1. Please note however, if steel building plans will be submitted later as a deferred submittal, an inspection hold will be placed preventing a framing inspection until deferred submittals have been submitted, reviewed and approved. Please allow ample time for review. 3. Remove all references to “fire barrier” on steel building erection plans. Walls are actually “fire walls” per FBC-Building Section 706.1 and shall be referred to as fire walls. 4. Steel building design engineer shall certify structural stability of fire walls per Section 706.2 indicating either by written notes on one or more plan sheets indicating firewalls are designed and constructed to allow collapse of the structure on either side without collapse of the fire wall. As an alternative engineer can provide design in accordance with NFPA 221. 5. Steel building plans shall reference the 2020 Florida Building Code Building (2017 edition is referenced). Engineer to remove references to the IBC. 6. Reorganize UL fire wall details on Sheet A801 so that the file is organized to read from top to bottom and left to right from file beginning to file end. As currently printed, file details appear out of order. Please also ensure complete file is provided. Please be advised, the UL (U419) design provided is for a proprietary fire wall; therefore no material substitutions are allowed beyond those called out in the file. IT IS STRONGLY recommended a note or notes be added advising the contractor of the limitations to those proprietary materials listed as deviations from approved materials will not be allowed under any circumstances. 7. Add fire wall door design standard to door schedule or by conspicuous note for doors in firewalls per Section 716.5.6. 8. Provide dimensions (both width and length in the direction of egress) of landings at all exterior doors per Section 1010.1.6. All comments below per the 2020 Florida Building Code-Accessibility 1. Provide maneuvering dimensions of exterior landings at all exterior doors based on side approach to hinge side of pull side of doors per Section 404.2.4 and Table 404.2.4.1. It appears the required dimension of 24 inches extending beyond the latch side has not been provided. It is unclear if the landing provides 48 inches of clearance perpendicular to doorways. 2. Provide maneuvering dimensions at all interior doorways based on forward approach per Section 404.2.4 and Table3 404.2.4.1. It is unclear if maneuvering space of 18 inches is provided beyond the latch side on the pull side of interior doors including bathroom door.
DSD COMPLETE 05/03/2021 05/06/2021
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
ELEC HOLD 05/03/2021 05/10/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Reference the 2020 Energy code
FI1 COMPLETE 05/03/2021 05/17/2021
Note: Released By: WILLIAM MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
MECH HOLD 05/03/2021 05/11/2021
Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM 1. All codes need to reference 2020 7Th edition- FBC Mechanical, FBC Energy Conservation, and FBC Accessibility 2. Ventialtion calculation needs to reference 2020 7Th edition FBC Mechanical 3. Provide heatload calculation per C403.2.1 FBC Energy Conservation 2020 7th edition
PLUM COMPLETE 05/03/2021 05/17/2021
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
UD1 HOLD 05/03/2021 05/06/2021
Note: Held By: CHRIS JOHNSON - - CJOHNSON@PALMCOASTGOV.COM Civil plans do not show potable water service to this building.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE - COMMERCIAL ¤60.00 09/27/2021
INSPECTION- ELECTRICAL ¤653.40 09/27/2021
INSPECTION - MECHANICAL ¤653.40 09/27/2021
INSPECTION - PLUMBING ¤653.40 09/27/2021
PLAN REVIEW - COMMERCIAL ¤1,137.35 09/27/2021
BUILDING DISCOUNT 100% (¤3,157.55) 09/27/2021
IMPACT FEE FIRE ¤13,407.75 09/27/2021
IMPACT FEE TRANSPORTATION ¤10,248.98 09/27/2021
SITE PLAN 20 ¤20.00 09/27/2021
SURCHARGE FS 533.721 ¤2.00 09/27/2021
SURCHARGE - FS 468.631 ¤2.00 09/27/2021
Fees Total Due: ¤0.00 Total Paid: ¤23,680.73