Permit #2021050091

Permit Details

Status: COED

Parcel Id: 03-12-31-0000-01010-0120
Total Square Footage: 9800 sqft
Block: 01010
Subdivision: -
Job Phone: 407-448-9300
Location Address: 6372 STATE HWY 100 E
Type: BC - BUILDING COMMERCIAL
Issue Date: 09/22/2021
NOC: RECORDED
Applicant name: GARY WAYNE BRIDGES
Owner: BELLA CITA STORAGE LLC

Address

880 BAY ROAD

MOUNT DORA, FL 32757

Lot: 0120
Contracted Stated Job Value: ¤392,000.00
Job Description: BUILDING D- SELF STORAGE FACILITY
Type: CN

Contractor

G&M CONSTRUCTION SERVICES, INC.
Status Location Address State License Number Phone
INACTIVE

PO BOX 2316

ORLANDO, FL 32804

CGC062542 (Exp: 08/31/2022) 407-448-9300

Sub Contractors

MATTHEW JAMES BLANCHARD
Status Location Address State License Number Phone
INACTIVE

PO BOX 932

MT. DORA, FL 32757

EC13009373 (Exp: 08/31/2022) 352-383-4868

Inspection History

Type Request Date Result Inspector
BUILDING FINAL 07/01/2022 FINAL APPROVED DCUSHING
FIRE FINAL 07/01/2022 APPROVED JMUNSON
U - UTILITY COMMERCIAL FINAL 07/01/2022 APPROVED JHARDING
FOUNDATION SURVEY - OFFICE USE ONLY 06/30/2022 APPROVED DLEAP
FIREWALL FINAL 06/23/2022 FINAL APPROVED DCUSHING
FIREWALL PENETRATIONS 06/23/2022 APPROVED DCUSHING
EXTERIOR ARCHITECTURAL FEATURES 06/21/2022 APPROVED JHARDING
ELECTRIC FINAL 06/07/2022 APPROVED RMARTIN
FIREWALL FRAMING 05/06/2022 Disapproved - NO FEE LMILLER
Note: THIS IS A REINSPECTION Firewall and Firewall and base detail was is not as proposed 5-6-22 Firewall and Firewall and base detail was is not as proposed also still does not meet fire sepration requirements at outside walls
FIREWALL FRAMING 03/23/2022 Disapproved -FEE REQUIRED LMILLER
Note: Firewall and Firewall and base detail was is not as proposed
LATH/BRICK/WATER BARRIER 12/30/2021 APPROVED LMILLER
EXTERIOR WALL SHEATHING / SHEARWALL 12/13/2021 APPROVED - AS NOTED LMILLER
Note: This is for DensGlass screw inspection only. Approved based on site inspection verifying screws are applied in vertical rows 12 inches apart max with max spacing of 6 inches within rows. (approved based on conversations between Building Official and Architect).
ROOF SHEATHING / BRACE / TIE DOWN 11/19/2021 PARTIALLY APPROVED LMILLER
Note: THIS IS A REINSPECTION need detail for method of end panel application (reversed) sheathing passed
ROOF SHEATHING / BRACE / TIE DOWN 11/18/2021 CANCELLED BY APPLICANT LMILLER
MONOLITHIC SLAB 10/01/2021 APPROVED JWALKER
FOOTER 10/01/2021 APPROVED JWALKER

Review History

Department Status Date In Date Out
BADMIN INFORMATION 06/30/2022 06/30/2022
Note: Marked INFORMATION By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM PLEASE RESUBMIT A SIGNED AND SEALED OR DIGITALLY FOUNDATION SURVEY AND NAME IT FOUNDATION NOT SURVEY
BADMIN INFORMATION 06/30/2022 06/30/2022
Note: Marked INFORMATION By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM missing Foundation
PLENG COMPLETE 06/30/2022 06/30/2022
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
FI1 COMPLETE 09/21/2021 09/22/2021
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
ARCHR COMPLETE 09/21/2021 09/21/2021
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
BLD COMPLETE 09/09/2021 09/09/2021
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Upon further review of the previous Building Plan Review Hold, the architect and engineer responded to all comments.
ARCHR HOLD 09/02/2021 09/21/2021
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM Submit color elevation plan in a single PDF file.
ELEC COMPLETE 09/02/2021 09/03/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 09/02/2021 09/08/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
FI1 HOLD 09/02/2021 09/16/2021
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Still need the Building Lighting plans for Building D (plans provided are for building C)
PLUM COMPLETE 09/02/2021 09/07/2021
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Plumbing - not applicable.
BLD HOLD 09/02/2021 09/07/2021
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comments: 2. Design professional in responsible charge to fill in steel building design engineer’s "approval’ certification box and sign and date on each plan sheet. As an alternative, these plan sheets can be provided at a later date as a deferred submittal in accordance with FBC-Building Section 107.3.4.1. If requesting these plan sheets to be a deferred submittal, approval blocks will still need to be signed and dated before they are submitted to the Building Department for review and approval and Architectural cover sheet will have to be noted in some manner indicating steel building plans will be provided at a later date as a deferred submittal per Section 107.3.4.1. Please note however, if steel building plans will be submitted later as a deferred submittal, an inspection hold will be placed preventing a framing inspection until deferred submittals have been submitted, reviewed and approved. Please allow ample time for review. 3. Remove all references to "fire barrier" on steel building erection plans. Walls are actually "fire walls" per FBC-Building Section 706.1 and shall be referred to as fire walls. 8. Provide dimensions (both width and length in the direction of egress) of landings at all exterior doors per Section 1010.1.6. All comments below per the 2020 Florida Building Code-Accessibility 1. Provide maneuvering dimensions of exterior landings at all exterior doors based on side approach to hinge side of pull side of doors per Section 404.2.4 and Table 404.2.4.1. It appears the required dimension of 24 inches extending beyond the latch side has not been provided. It is unclear if the landing provides 48 inches of clearance perpendicular to doorways. 2. Provide maneuvering dimensions at all interior doorways based on forward approach per Section 404.2.4 and Table3 404.2.4.1. It is unclear if maneuvering space of 18 inches is provided beyond the latch side on the pull side of interior doors including bathroom door. Repeat comments:
BADMIN HOLD 06/24/2021 06/24/2021
Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM RENAME TO NOC.PDF
BADMIN COMPLETE 06/24/2021 06/24/2021
Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM
BADMIN HOLD 06/23/2021 06/23/2021
Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM RENAME TO NOC.PDF
BADMIN COMPLETE 06/23/2021 06/23/2021
Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM
ARCHR HOLD 05/03/2021 05/06/2021
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM Provide color elevation renderings approved with the DO to note colors being used on the walls.
BLD HOLD 05/03/2021 05/17/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building 1. Provide complete copy of Geotechnical Investigation Report signed and sealed by a Florida licensed professional engineer. It appears a geotechnical investigation report was not included with the civil plans under the Commercial Site Development Permit. 2. Design professional in responsible charge to fill in steel building design engineer’s “approval’ certification box and sign and date on each plan sheet. As an alternative, these plan sheets can be provided at a later date as a deferred submittal in accordance with FBC-Building Section 107.3.4.1. If requesting these plan sheets to be a deferred submittal, approval blocks will still need to be signed and dated before they are submitted to the Building Department for review and approval and Architectural cover sheet will have to be noted in some manner indicating steel building plans will be provided at a later date as a deferred submittal per Section 107.3.4.1. Please note however, if steel building plans will be submitted later as a deferred submittal, an inspection hold will be placed preventing a framing inspection until deferred submittals have been submitted, reviewed and approved. Please allow ample time for review. 3. Remove all references to “fire barrier” on steel building erection plans. Walls are actually “fire walls” per FBC-Building Section 706.1 and shall be referred to as fire walls. 4. Steel building design engineer shall certify structural stability of fire walls per Section 706.2 indicating either by written notes on one or more plan sheets indicating firewalls are designed and constructed to allow collapse of the structure on either side without collapse of the fire wall. As an alternative engineer can provide design in accordance with NFPA 221. 5. Steel building plans shall reference the 2020 Florida Building Code Building (2017 edition is referenced). Engineer to remove references to the IBC. 6. Reorganize UL fire wall details on Sheet A801 so that the file is organized to read from top to bottom and left to right from file beginning to file end. As currently printed, file details appear out of order. Please also ensure complete file is provided. Please be advised, the UL (U419) design provided is for a proprietary fire wall; therefore no material substitutions are allowed beyond those called out in the file. IT IS STRONGLY recommended a note or notes be added advising the contractor of the limitations to those proprietary materials listed as deviations from approved materials will not be allowed under any circumstances. 7. Add fire wall door design standard to door schedule or by conspicuous note for doors in firewalls per Section 716.5.6. 8. Provide dimensions (both width and length in the direction of egress) of landings at all exterior doors per Section 1010.1.6. All comments below per the 2020 Florida Building Code-Accessibility 1. Provide maneuvering dimensions of exterior landings at all exterior doors based on side approach to hinge side of pull side of doors per Section 404.2.4 and Table 404.2.4.1. It appears the required dimension of 24 inches extending beyond the latch side has not been provided. It is unclear if the landing provides 48 inches of clearance perpendicular to doorways. 2. Provide maneuvering dimensions at all interior doorways based on forward approach per Section 404.2.4 and Table3 404.2.4.1. It is unclear if maneuvering space of 18 inches is provided beyond the latch side on the pull side of interior doors including bathroom door.
DSD COMPLETE 05/03/2021 05/06/2021
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
ELEC HOLD 05/03/2021 05/10/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Reference the 2020 Energy code
FI1 HOLD 05/03/2021 05/17/2021
Note: Held By: WILLIAM MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM 1. FFPC 1 13.3.2.27.4 An automatic Sprinkler system is needed for Mini-Storage Buildings greater 2,500 s/f The building as designed requires Sprinklers. 2. Please provide Fire Extinguishers as required per NFPA 1, section 13.6 and table 13.6.1.2 3. Need the Building Lighting plans for Building D (plans provided are for building C)
MECH HOLD 05/03/2021 05/11/2021
Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM 1. All codes need to reference 2020 7Th edition- FBC Mechanical, FBC Energy Conservation, and FBC Accessibility 2. Ventialtion calculation needs to reference 2020 7Th edition FBC Mechanical 3. Provide heatload calculation per C403.2.1 FBC Energy Conservation 2020 7th edition
PLUM HOLD 05/03/2021 05/17/2021
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM It appears Enlarged Plumbing Plan from Building A was inadvertently uploaded for this permit. It also appears Overall Plumbing Plan from Building E (hose-bibbs only) was uplloaded for this permit. Building E floor plan not indicate a bathroom in this building, but Enlarged Plumbing Plan and Overall Plumbing Plan does. Please advise if this is true and then the City can remove the plumbing plan sheets accordingly.
UD1 COMPLETE 05/03/2021 05/06/2021
Note: Released By: CHRIS JOHNSON - - CJOHNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION - COMMERCIAL ¤60.00 06/29/2022
BUILDING DISCOUNT 100% (¤1,396.40) 09/22/2021
3% FIRE IMPACT FEE CREDIT (¤173.46) 09/22/2021
IMPACT FEE FIRE ¤5,782.00 09/22/2021
IMPACT FEE TRANSPORTATION ¤4,419.80 09/22/2021
SITE PLAN 20 ¤20.00 09/22/2021
SURCHARGE FS 533.721 ¤2.00 09/22/2021
SURCHARGE - FS 468.631 ¤2.00 09/22/2021
3% TRANS IMPACT FEE CREDIT (¤132.59) 09/22/2021
ADMINISTRATIVE - COMMERCIAL ¤60.00 09/22/2021
INSPECTION- ELECTRICAL ¤295.20 09/22/2021
INSPECTION - MECHANICAL ¤295.20 09/22/2021
INSPECTION - PLUMBING ¤295.20 09/22/2021
PLAN REVIEW - COMMERCIAL ¤450.80 09/22/2021
Fees Total Due: ¤0.00 Total Paid: ¤9,979.75