I want to search for...
Permit #2021050149
Permit Details
Status: COED
| Parcel Id: 03-12-31-0000-01010-0120 |
| Total Square Footage: 6750 sqft |
| Block: 01010 |
| Subdivision: - |
| Job Phone: 407-448-9300 |
| Location Address: 6372 STATE HWY 100 E |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 12/14/2021 |
| NOC: RECORDED |
| Applicant name: GARY WAYNE BRIDGES |
| Owner: BELLA CITA STORAGE LLC |
|
Address 880 BAY ROAD MOUNT DORA, FL 32757 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤405,000.00 |
| Job Description: Building J- Self Storage Facility |
| Type: CN |
Contractor
G&M CONSTRUCTION SERVICES, INC.
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 2316 ORLANDO, FL 32804 |
CGC062542 (Exp: 08/31/2022) | 407-448-9300 |
Sub Contractors
THOMAS ERIC SWORD
| Status | Location Address | State License Number | Phone |
| CANCEL |
10330 PLEASANT VIEW DR LEESBURG, FL 34788 |
CAC1814523 (Exp: 08/31/2022) | 352-434-7550 |
MATTHEW JAMES BLANCHARD
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 932 MT. DORA, FL 32757 |
EC13009373 (Exp: 08/31/2022) | 352-383-4868 |
JOHN CHARLES GRAY
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2707 ANNETTE STREET FLAGLER BEACH, FL 32136 |
CFC1425975 (Exp: 08/31/2026) | (386)793-3690 | (386)439-7585 |
Inspection History
| Type | Request Date | Result | Inspector |
| U - UTILITY COMMERCIAL FINAL | 06/24/2022 | APPROVED | JHARDING |
| EXTERIOR ARCHITECTURAL FEATURES | 06/21/2022 | APPROVED | JHARDING |
| BUILDING FINAL | 06/14/2022 | FINAL APPROVED | DCUSHING |
| FIRE FINAL | 06/14/2022 | APPROVED | RMARTIN |
| FIREWALL FRAMING | 06/13/2022 | APPROVED | DCUSHING |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION partial Firewall Framing for botton track nailing only, OK to place first drywall layer up within 2 feet of top track only at contractor risk 2-24-22 wrong inspection called in, proper inspection set up and partially resulted 3-14-22 Wrong inspection set (needed Firewall Nailing) All complete, clips in place | |||
| FIREWALL FINAL | 06/13/2022 | APPROVED | DCUSHING |
| ELECTRIC FINAL | 06/07/2022 | APPROVED | RMARTIN |
| FOUNDATION SURVEY - OFFICE USE ONLY | 06/01/2022 | APPROVED | DLEAP |
| FIREWALL PENETRATIONS | 05/26/2022 | APPROVED | DCUSHING |
| ELECTRIC - EARLY POWER | 05/10/2022 | APPROVED - AS NOTED | RMARTIN |
| FIREWALL DRYWALL NAILING | 04/27/2022 | APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION partial for first layer up to within 2 - feet of roof, first layer only 3-14-22 Minimum horizontal offset not met per UL419 detail 3-22-22 Partial only, Second Layer approved per Building Official PB | |||
| EXTERIOR WALL SHEATHING / SHEARWALL | 03/29/2022 | PARTIALLY APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION need plans on site for inspection 12-22-21... end wall panels only call back in for DesGlass screw off inspeection 01-05-21... for DensGlass screw off inspeection at endwalls only. 3-22-22... wrong inspection called in (should have called in Firewall drywall nailing inspection) 3-29-22 wall sheathing screw-off only (Still need trim for approval) | |||
| ROOF SHEATHING / BRACE / TIE DOWN | 03/29/2022 | PARTIALLY APPROVED | LMILLER |
| Note: sheathing only, (need to complete firewalls prior to approval) | |||
| EXTERIOR WALL SHEATHING / SHEARWALL | 03/22/2022 | Disapproved - NO FEE | LMILLER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION need plans on site for inspection 12-22-21... end wall panels only call back in for DesGlass screw off inspeection 01-05-21... for DensGlass screw off inspeection at endwalls only. 3-22-22... wrong inspection called in (should have called in Firewall drywall nailing inspection) | |||
| FIREWALL DRYWALL NAILING | 03/22/2022 | PARTIALLY APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION partial for first layer up to within 2 - feet of roof, first layer only 3-14-22 Minimum horizontal offset not met per UL419 detail 3-22-22 Partial only, Second Layer approved per Building Official PB | |||
| FIREWALL FRAMING | 03/14/2022 | Disapproved - NO FEE | LMILLER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION partial Firewall Framing for botton track nailing only, OK to place first drywall layer up within 2 feet of top track only at contractor risk 2-24-22 wrong inspection called in, proper inspection set up and partially resulted 3-14-22 Wrong inspection set (needed Firewall Nailing) | |||
| FIREWALL DRYWALL NAILING | 03/14/2022 | Disapproved - NO FEE | LMILLER |
| Note: THIS IS A REINSPECTION partial for first layer up to within 2 - feet of roof, first layer only 3-14-22 Minimum horizontal offset not met per UL419 detail | |||
| FIREWALL FRAMING | 02/24/2022 | CANCELLED BY APPLICANT | LMILLER |
| Note: THIS IS A REINSPECTION partial Firewall Framing for botton track nailing only, OK to place first drywall layer up within 2 feet of top track only at contractor risk 2-24-22 wrong inspection called in, proper inspection set up and partially resulted | |||
| FIREWALL DRYWALL NAILING | 02/24/2022 | PARTIALLY APPROVED | LMILLER |
| Note: partial for first layer up to within 2 - feet of roof, first layer only | |||
| FIREWALL FRAMING | 02/16/2022 | PARTIALLY APPROVED | LMILLER |
| Note: partial Firewall Framing for botton track nailing only, OK to place first drywall layer up within 2 feet of top track only at contractor risk | |||
| LATH/BRICK/WATER BARRIER | 01/18/2022 | APPROVED | LMILLER |
| Note: endwalls only | |||
| EXTERIOR WALL SHEATHING / SHEARWALL | 01/05/2022 | PARTIALLY APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION need plans on site for inspection 12-22-21... end wall panels only call back in for DesGlass screw off inspeection 01-05-21... for DensGlass screw off inspeection at endwalls only. | |||
| EXTERIOR WALL SHEATHING / SHEARWALL | 12/22/2021 | PARTIALLY APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION need plans on site for inspection 12-22-21... end wall panels only call back in for DesGlass screw off inspeection | |||
| EXTERIOR WALL SHEATHING / SHEARWALL | 12/15/2021 | Disapproved -FEE REQUIRED | LMILLER |
| Note: need plans on site for inspection |
Review History
| Department | Status | Date In | Date Out |
| PLENG | COMPLETE | 05/27/2022 | 05/31/2022 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/21/2022 | 03/21/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 12/02/2021 | 12/13/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/02/2021 | 12/13/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ARCHR | COMPLETE | 09/27/2021 | 09/29/2021 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| UD1 | COMPLETE | 09/27/2021 | 09/27/2021 |
| Note: Released By: CHRIS JOHNSON - - CJOHNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 09/27/2021 | 09/29/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 09/27/2021 | 09/27/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/27/2021 | 10/11/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building 1. (Repeat Comment) Provide complete copy of Geotechnical Investigation Report signed and sealed by a Florida licensed professional engineer. It appears a geotechnical investigation report was not included with the civil plans under the Commercial Site Development Permit. On approved Site Plans was submitted. 2. (Repeat Comment) Design professional in responsible charge to fill in steel building design engineer’s “approval’ certification box and sign and date on each plan sheet. As an alternative, these plan sheets can be provided at a later date as a deferred submittal in accordance with FBC-Building Section 107.3.4.1. If requesting these plan sheets to be a deferred submittal, approval blocks will still need to be signed and dated before they are submitted to the Building Department for review and approval and Architectural cover sheet will have to be noted in some manner indicating steel building plans will be provided at a later date as a deferred submittal per Section 107.3.4.1. Please note however, if steel building plans will be submitted later as a deferred submittal, an inspection hold will be placed preventing a framing inspection until deferred submittals have been submitted, reviewed and approved. Please allow ample time for review. | |||
| FI1 | COMPLETE | 09/27/2021 | 10/05/2021 |
| Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 09/27/2021 | 10/04/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Second Request - Per Patrick Buckley CBO upload Page P200 plumbing plans for review. | |||
| MECH | HOLD | 05/17/2021 | 05/17/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM This is the corrected mechanical review. 1. Upon discussion with the building, this building is classified as an S2 occupancy. An Enclosed parking garage. Provide mechanical ventilation calculation and ventilation details per Section 404 FBC Mechanical 2020 7Th edition. 2. All codes need to reference 2020 7Th edition- FBC Mechanical, FBC Energy Conservation, and FBC Accessibility | |||
| ARCHR | HOLD | 05/04/2021 | 05/06/2021 |
| Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM Provide color elevation renderings approved with the DO to note colors being used on the walls. | |||
| BLD | HOLD | 05/04/2021 | 05/18/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide complete copy of Geotechnical Investigation Report signed and sealed by a Florida licensed professional engineer. It appears a geotechnical investigation report was not included with the civil plans under the Commercial Site Development Permit. 2. Change occupancy classification in occupancy description on cover page from S-1 to S-2. Building cannot be classified as a private garage by definition and is not a commercial repair or open parking garage also in definitions. | |||
| DSD | COMPLETE | 05/04/2021 | 05/06/2021 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 05/04/2021 | 05/10/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Reference the 2020 Energy code 2. Riser diagram does not match the load for panel J | |||
| FI1 | HOLD | 05/04/2021 | 05/18/2021 |
| Note: Held By: WILLIAM MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Provide Fire Extinguishers as required per FFPC 1, section 13.6 and table 13.6.1.2 Provide Fire Extinguishers located so that the maximum travel distances does not exceed 75 ft. FFPC 1, 13.6.3.2.1.2.2 | |||
| MECH | HOLD | 05/04/2021 | 05/11/2021 |
| Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM All codes need to reference 2020 7Th edition- FBC Mechanical, FBC Energy Conservation, and FBC Accessibility | |||
| PLUM | HOLD | 05/04/2021 | 05/18/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Per Patrick Buckley CBO upload Page P200 plumbing plans for review. | |||
| UD1 | HOLD | 05/04/2021 | 05/06/2021 |
| Note: Held By: CHRIS JOHNSON - - CJOHNSON@PALMCOASTGOV.COM Civil plans do not show potable water service to this building. P200 not in the plans |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 03/23/2022 |
| REINSPECTION - COMMERCIAL | ¤60.00 | 03/23/2022 |
| BUILDING DISCOUNT 100% | (¤2,287.50) | 12/14/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤199.12) | 12/14/2021 |
| IMPACT FEE FIRE | ¤6,637.50 | 12/14/2021 |
| IMPACT FEE TRANSPORTATION | ¤5,073.75 | 12/14/2021 |
| PERMIT FEE | ¤2,227.50 | 12/14/2021 |
| SITE PLAN 20 | ¤20.00 | 12/14/2021 |
| SURCHARGE FS 533.721 | ¤9.29 | 12/14/2021 |
| SURCHARGE - FS 468.631 | ¤14.07 | 12/14/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤152.21) | 12/14/2021 |
| ADMINISTRATIVE - COMMERCIAL | ¤60.00 | 12/14/2021 |
| INSPECTION- ELECTRICAL | ¤303.00 | 12/14/2021 |
| INSPECTION - MECHANICAL | ¤303.00 | 12/14/2021 |
| INSPECTION - PLUMBING | ¤303.00 | 12/14/2021 |
| PLAN REVIEW - COMMERCIAL | ¤465.75 | 12/14/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤12,870.53 |