I want to search for...

Permit #2021050661

Permit Details

Status: COED

Parcel Id: 29-10-31-5540-00000-0340
CONDITIONED SPACE: 2902 sqft
GARAGE: 910 sqft
OPENED PORCH (WITH ROOF) : 546 sqft
OPENED PORCH (WITH ROOF) : 145 sqft
Total Square Footage: 4503 sqft
Block: 00000
Subdivision: 1005 - SANCTUARY SUBDIVISION
Job Phone: 386-263-8272
Location Address: 62 OLD OAK DR S
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/31/2021
NOC: RECORDED
Applicant name: ROY CHARLES WALDHAUER
Owner: MCAVOY DONALD L F JR & SILVIA MOOREFIELD H&W

Address

4321 TRADEWINDS DRIVE

JACKSONVILLE, FL 32250

Lot: 0340
Contracted Stated Job Value: ¤400,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

BY THE SHORE INC.
Status Location Address State License Number Phone Fax
ACTIVE

1600 N STATE STREET # 102

,

CRC1327300 (Exp: 08/31/2026) 386-263-8272 386-263-8289

Sub Contractors

THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
DANIEL DAVID RUTKOWSKI III
Status Location Address State License Number Phone Fax
ACTIVE

1687 STATE AVENUE

HOLLY HILL, FL 32117

CCC1328639 (Exp: 08/31/2026) 386-290-7490 386-256-0001
KEN DEPRINZIO
Status Location Address State License Number Phone Fax
ACTIVE

325 WALKER STREET

HOLLY HILL, FL 32117

11351 (Exp: 08/31/2026) 386-672-8494 386-673-7856

Inspection History

Type Request Date Result Inspector
GAS FINAL 02/14/2023 FINAL APPROVED AGAETANO
Note: Inspector Notes from Inspection 2225 LOOKED AT GAS ALREADY
BLD - BUILDING FINAL 02/14/2023 FINAL APPROVED AGAETANO
Note: 2/7/2023 - PREVIOUS INSPECTION NOTES 02-07-2023 1. AC needs to be 3" above grade. 2. Disconnect needs to be serviceable of 30".
WILDLIFE CHECK - ENVIRONMENTAL 02/07/2023 APPROVED JMYERS
BLD - BUILDING FINAL 02/07/2023 Disapproved - NO FEE AGAETANO
Note: 02-07-2023 1. AC needs to be 3" above grade. 2. Disconnect needs to be serviceable of 30".
U-CROSS CONNECTION 01/06/2023 APPROVED - AS NOTED LFITZGERALD
Note: has well irrigation-no cross connection
ROW - STORMWATER FINAL 01/05/2023 APPROVED GBERTOLA
U -UTILITY RESIDENTIAL FINAL 01/05/2023 APPROVED - AS NOTED LFITZGERALD
Note: water meter pit too low-utility dept. informed too raise
TUB SET 01/05/2023 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2075 BOTH GRAVITY SEWER AND U-SEWER TIE IN ARE APPROVED, CONTRACTOR NEEDS TO SCEDULE THE U-SEWER TIE IN INSPECTION FOR 7/22/22
GAS ROUGH 01/05/2023 APPROVED - AS NOTED MGIBSON
Note: LOOKED AT GAS ALREADY
ROW - FINAL APRON (AFTER POUR) 12/09/2022 FINAL APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/09/2022 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 12/09/2022 APPROVED EMADISON
Note: ** 12/09/22 RIGHT SIDE OF PROPERTY LINE NEEDS ONE MORE ROW OF SOD TO HOLD BARK MULCH IN PLACE AND TO PREVENT EROSION
ELECTRIC - EARLY POWER 09/15/2022 APPROVED RMARTIN
Note: Inspector Notes from Inspection 2200 THIS IS A REINSPECTION 1.Load side conductors can not be landed 2. UFER ground needs to be protected. NEC 2017 250.64 6/17/22 Emailed FPL at 9:46 am
ROW- PRE-APRON (PRE-POUR) 08/19/2022 APPROVED EMADISON
Note: ** 08/19/22 AT THE TIME OF THIS INSPECTION EVERYTHING LOOKS GOOD READY TO POUR
U - SEWER TIE IN 07/22/2022 APPROVED MGIBSON
GRAVITY SEWER TEST 07/21/2022 APPROVED - AS NOTED MGIBSON
Note: BOTH GRAVITY SEWER AND U-SEWER TIE IN ARE APPROVED, CONTRACTOR NEEDS TO SCEDULE THE U-SEWER TIE IN INSPECTION FOR 7/22/22
GRAVITY SEWER TEST 07/19/2022 CANCELLED BY APPLICANT WEB
ELECTRIC-TUG 06/17/2022 APPROVED - AS NOTED JMUNSON
Note: THIS IS A REINSPECTION 1.Load side conductors can not be landed 2. UFER ground needs to be protected. NEC 2017 250.64 6/17/22 Emailed FPL at 9:46 am
ELECTRIC-TUG 06/14/2022 Disapproved - NO FEE JMUNSON
Note: 1.Load side conductors can not be landed 2. UFER ground needs to be protected. NEC 2017 250.64
INSULATION 04/12/2022 APPROVED AGAETANO
ALL ROUGH 04/06/2022 APPROVED - AS NOTED AGAETANO
Note: 1. Stand alone tub in bathroom next to the garage drain will need to be filled. Stand alone tub will need drywall first. Add a tub set in inspection. 2. Gas line in ceiling at T needs to be secured properly. This is for gas rough for the interior of the home only. A revision was added already. 3. 2" vent stack at bathroom ceiling at garage needs to be supported properly.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/05/2022 APPROVED AGAETANO
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Piggy back trusses missing hold down anchors. Over framing is to be strapped to trusses below. Missing Gable end bracing and blocking - Detail page 6/7. DO1 truss missing strap at front post. Missing engineer trusses at A05,A08,A09. CG2, CG3 not strapped to wall below. Front wall trusses missing straps at bearing wall. Please specify R1, R2, R3/R4 are on the connector schedule. Have architect specify hold down anchors at girder trusses. Check that all threads at bearing walls at all locations. 3-25-22 Missing engineer trusses at A05,A08,A09. CG1, CG2 not strapped to wall below and not shown in connector schedule. Please specify R1, R2, R3/R4 are on the connector schedule. Have architect specify hold down anchors at girder trusses. Check that all threads at bearing walls at all locations (interior garage walls maximum OC spacing of all-thread exceeded, calls for a max of 6 ft on wall details) overframing not tied to framing below
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/25/2022 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION Piggy back trusses missing hold down anchors. Over framing is to be strapped to trusses below. Missing Gable end bracing and blocking - Detail page 6/7. DO1 truss missing strap at front post. Missing engineer trusses at A05,A08,A09. CG2, CG3 not strapped to wall below. Front wall trusses missing straps at bearing wall. Please specify R1, R2, R3/R4 are on the connector schedule. Have architect specify hold down anchors at girder trusses. Check that all threads at bearing walls at all locations. 3-25-22 Missing engineer trusses at A05,A08,A09. CG1, CG2 not strapped to wall below and not shown in connector schedule. Please specify R1, R2, R3/R4 are on the connector schedule. Have architect specify hold down anchors at girder trusses. Check that all threads at bearing walls at all locations (interior garage walls maximum OC spacing of all-thread exceeded, calls for a max of 6 ft on wall details) overframing not tied to framing below
WINDOW NAILING 03/25/2022 APPROVED LMILLER
Note: added at the request of site manager (approved)
ROOF VALLEY & METAL 01/14/2022 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/08/2021 Disapproved - NO FEE AGAETANO
Note: Piggy back trusses missing hold down anchors. Over framing is to be strapped to trusses below. Missing Gable end bracing and blocking - Detail page 6/7. DO1 truss missing strap at front post. Missing engineer trusses at A05,A08,A09. CG2, CG3 not strapped to wall below. Front wall trusses missing straps at bearing wall. Please specify R1, R2, R3/R4 are on the connector schedule. Have architect specify hold down anchors at girder trusses. Check that all threads at bearing walls at all locations. Roof sheathing and wall sheathing pass inspection.
FOUND SURVEY APPROVED (OFFICE) 11/15/2021 APPROVED TDOAK
MONOLITHIC SLAB 11/01/2021 APPROVED RMARTIN
PLUMBING 1ST ROUGH UNDERGROUND 10/18/2021 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 09/01/2021 APPROVED CSTONE

Review History

Department Status Date In Date Out
BLD COMPLETE 01/20/2023 01/20/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Building review not required.
ELEC COMPLETE 01/20/2023 01/20/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/29/2022 03/30/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
PLUM HOLD 03/22/2022 03/22/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: Repeat Comment 1. Gas riser diagram appears to be exactly the same as the original diagram. Please identify the change(s) made for clarity per FBC 7th Ed. Sec. 107.3. Gas Riser is lastly dated 12/8/2021.
BLD COMPLETE 03/22/2022 03/22/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
PLUM COMPLETE 03/22/2022 03/24/2022
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
BLD HOLD 02/02/2022 02/03/2022
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Revision: Revision Form only indicates "Revised Plan". This revision appears to be an additional Sheet 2 of 8 deleting the AC Duct Layout and Electrical Load Calculations as shown on Sheet 2 of 7. You can delete the AC Duct layout because there is another copy on AC Energy calculation. The Electical Load Calculation cannot be deleted because there would be NO RECORD of it. Please clarify the revision narrative of what you intend to do - FBC 7th Ed. Sec. 107.3.
PLUM HOLD 02/02/2022 02/03/2022
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Revision: Gas riser diagram appears to be exactly the same as the original diagram. Please identify the change(s) made for clarity per FBC 7th Ed. Sec. 107.3.
PLUM COMPLETE 12/09/2021 12/13/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/15/2021 11/15/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 11/15/2021 11/15/2021
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/21/2021 09/21/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 09/21/2021 09/29/2021
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON COMPLETE 09/21/2021 09/21/2021
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/23/2021 07/23/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 07/23/2021 07/29/2021
Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM
ZON COMPLETE 07/23/2021 07/23/2021
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
PLENV COMPLETE 07/22/2021 07/22/2021
Note: Released By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM The Approved After Action Report has been accepted
BLD COMPLETE 06/21/2021 06/24/2021
Note: Released By: JPI
PLENV HOLD 06/21/2021 06/22/2021
Note: Held By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM Staff appreciates the update on the Gopher Tortoise relocation. Please provide Approved After Action Report after relocation activities have been completed.
ELEC COMPLETE 06/21/2021 06/21/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 06/21/2021 06/21/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
ZON HOLD 06/21/2021 06/22/2021
Note: Held By: ESTELLE LENS - (386)986-3751 - Repeat comment: Please provide the driveway width at the garage door. (along the garage door)
PLENV HOLD 05/14/2021 05/19/2021
Note: Held By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM Staff conducted a site visit on 5/19/2021 and noted Potentially Occupied Gopher Tortoise burrows. Please either provide a Gopher Tortoise survey by a QEP showing the burrow outside of construction activities or provide the Approved After Action Report after relocation activities have been completed.
PLFM COMPLETE 05/14/2021 05/14/2021
Note: Released By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM According to the Site Plan submitted on 5/12/21 the structure will be outside of the Special Flood Hazard Area. No elevation certificates will be required.
BLD HOLD 05/12/2021 05/16/2021
Note: Held By: JPI 1. Product approval for swing door, widndows and soffit are not valid. Please provide another selection. 2. Indicate slope of garage floor. 3. Provide size of attic access. 4. Provide foundation detail for garage to dwelling wall. 5. Provide mullion product approval number. 6. Incorrect Code citation on drawings 3 thru 7. 7. Provide garage to dwelling fire separation details. 8. Provide mixed construction details. 9. Provide dutch gable end details.
CUSVC COMPLETE 05/12/2021 05/14/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 05/12/2021 05/12/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Outlets in the garage need to be GFCI protected. NEC 2017 210.8 Reference the 2017 NEC
ENGIN1 COMPLETE 05/12/2021 05/12/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 05/12/2021 05/17/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 05/12/2021 05/13/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide Energy Calcs from 2020 7Th edition code cycle 2. Plans show Frame wall w/ R19 Insulation and R30 insulation attic. Energy Calcs show Block wall with R5 and Spray foam R20 on roof deck. Revise to match. 3. Square footage on Energy Calcs does not match the house plans.
SW1 COMPLETE 05/12/2021 05/18/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
ZON HOLD 05/12/2021 05/14/2021
Note: Held By: ESTELLE LENS - (386)986-3751 - The proposed residence does not meet the 10' left side setback. Please provide the driveway width at the garage door. Need to show the A/C pad on the site plan. The driveway configuration on the landscape plan does not match the site plan. (A/C pad is shown on the landscape plan but not on the site plan.) The right side elevation is labeled as left side.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 02/13/2023
PLAN REVIEW - REVISION ¤32.50 02/13/2023
PLAN REVIEW - REVISION ¤32.50 02/13/2023
PLAN REVIEW - REVISION ¤32.50 02/13/2023
REINSPECTION RESIDENTIAL ¤40.00 02/13/2023
CONNECTION FEES ¤25.00 08/31/2021
METER - DEPOSIT ¤60.00 08/31/2021
WATER-METER ¤441.07 08/31/2021
ADMIN FEE ¤20.00 08/31/2021
BUILDING DISCOUNT 100% (¤1,880.00) 08/31/2021
ELECTRIC FEE ¤300.00 08/31/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 08/31/2021
IMPACT FEE FIRE ¤367.00 08/31/2021
IMPACT FEE PARKS ¤1,199.12 08/31/2021
IMPACT FEE SCHOOL ¤3,600.00 08/31/2021
IMPACT FEE TRANSPORTATION ¤3,139.00 08/31/2021
MECHANICAL FEE ¤300.00 08/31/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 08/31/2021
PLAN CHECK FEE ¤160.00 08/31/2021
PLUMBING FEE ¤300.00 08/31/2021
NEW RESIDENTIAL INSPECTIONS ¤800.00 08/31/2021
SITE PLAN 20 ¤20.00 08/31/2021
SURCHARGE FS 533.721 ¤2.00 08/31/2021
SURCHARGE - FS 468.631 ¤2.00 08/31/2021
STORM WATER PERMIT FEES ¤80.00 08/31/2021
3% TRANS IMPACT FEE CREDIT (¤94.17) 08/31/2021
SEWER INSPECTION ¤25.00 08/31/2021
SEWER CAPITAL FACILITY ¤4,664.55 08/31/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 08/31/2021
Fees Total Due: ¤0.00 Total Paid: ¤17,085.54