Permit #2021050661
Permit Details
Status: COED
| Parcel Id: 29-10-31-5540-00000-0340 |
| CONDITIONED SPACE: 2902 sqft |
| GARAGE: 910 sqft |
| OPENED PORCH (WITH ROOF) : 546 sqft |
| OPENED PORCH (WITH ROOF) : 145 sqft |
| Total Square Footage: 4503 sqft |
| Block: 00000 |
| Subdivision: 1005 - SANCTUARY SUBDIVISION |
| Job Phone: 386-263-8272 |
| Location Address: 62 OLD OAK DR S |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/31/2021 |
| NOC: RECORDED |
| Applicant name: ROY CHARLES WALDHAUER |
| Owner: MCAVOY DONALD L F JR & SILVIA MOOREFIELD H&W |
|
Address 4321 TRADEWINDS DRIVE JACKSONVILLE, FL 32250 |
| Lot: 0340 |
| Contracted Stated Job Value: ¤400,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
BY THE SHORE INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1600 N STATE STREET # 102 , |
CRC1327300 (Exp: 08/31/2026) | 386-263-8272 | 386-263-8289 |
Sub Contractors
THOMAS A REGULA
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11320 PHILLIPS PKWY DRIVE E JACKSONVILLE, FL 32256 |
CMC1250075 (Exp: 08/31/2026) | 904-278-0339 | 904-278-0366 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
KEN DEPRINZIO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
325 WALKER STREET HOLLY HILL, FL 32117 |
11351 (Exp: 08/31/2026) | 386-672-8494 | 386-673-7856 |
Inspection History
| Type | Request Date | Result | Inspector |
| GAS FINAL | 02/14/2023 | FINAL APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2225 LOOKED AT GAS ALREADY | |||
| BLD - BUILDING FINAL | 02/14/2023 | FINAL APPROVED | AGAETANO |
| Note: 2/7/2023 - PREVIOUS INSPECTION NOTES 02-07-2023 1. AC needs to be 3" above grade. 2. Disconnect needs to be serviceable of 30". | |||
| WILDLIFE CHECK - ENVIRONMENTAL | 02/07/2023 | APPROVED | JMYERS |
| BLD - BUILDING FINAL | 02/07/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 02-07-2023 1. AC needs to be 3" above grade. 2. Disconnect needs to be serviceable of 30". | |||
| U-CROSS CONNECTION | 01/06/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: has well irrigation-no cross connection | |||
| ROW - STORMWATER FINAL | 01/05/2023 | APPROVED | GBERTOLA |
| U -UTILITY RESIDENTIAL FINAL | 01/05/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: water meter pit too low-utility dept. informed too raise | |||
| TUB SET | 01/05/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2075 BOTH GRAVITY SEWER AND U-SEWER TIE IN ARE APPROVED, CONTRACTOR NEEDS TO SCEDULE THE U-SEWER TIE IN INSPECTION FOR 7/22/22 | |||
| GAS ROUGH | 01/05/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: LOOKED AT GAS ALREADY | |||
| ROW - FINAL APRON (AFTER POUR) | 12/09/2022 | FINAL APPROVED | EMADISON |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/09/2022 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/09/2022 | APPROVED | EMADISON |
| Note: ** 12/09/22 RIGHT SIDE OF PROPERTY LINE NEEDS ONE MORE ROW OF SOD TO HOLD BARK MULCH IN PLACE AND TO PREVENT EROSION | |||
| ELECTRIC - EARLY POWER | 09/15/2022 | APPROVED | RMARTIN |
| Note: Inspector Notes from Inspection 2200 THIS IS A REINSPECTION 1.Load side conductors can not be landed 2. UFER ground needs to be protected. NEC 2017 250.64 6/17/22 Emailed FPL at 9:46 am | |||
| ROW- PRE-APRON (PRE-POUR) | 08/19/2022 | APPROVED | EMADISON |
| Note: ** 08/19/22 AT THE TIME OF THIS INSPECTION EVERYTHING LOOKS GOOD READY TO POUR | |||
| U - SEWER TIE IN | 07/22/2022 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 07/21/2022 | APPROVED - AS NOTED | MGIBSON |
| Note: BOTH GRAVITY SEWER AND U-SEWER TIE IN ARE APPROVED, CONTRACTOR NEEDS TO SCEDULE THE U-SEWER TIE IN INSPECTION FOR 7/22/22 | |||
| GRAVITY SEWER TEST | 07/19/2022 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC-TUG | 06/17/2022 | APPROVED - AS NOTED | JMUNSON |
| Note: THIS IS A REINSPECTION 1.Load side conductors can not be landed 2. UFER ground needs to be protected. NEC 2017 250.64 6/17/22 Emailed FPL at 9:46 am | |||
| ELECTRIC-TUG | 06/14/2022 | Disapproved - NO FEE | JMUNSON |
| Note: 1.Load side conductors can not be landed 2. UFER ground needs to be protected. NEC 2017 250.64 | |||
| INSULATION | 04/12/2022 | APPROVED | AGAETANO |
| ALL ROUGH | 04/06/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: 1. Stand alone tub in bathroom next to the garage drain will need to be filled. Stand alone tub will need drywall first. Add a tub set in inspection. 2. Gas line in ceiling at T needs to be secured properly. This is for gas rough for the interior of the home only. A revision was added already. 3. 2" vent stack at bathroom ceiling at garage needs to be supported properly. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/05/2022 | APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Piggy back trusses missing hold down anchors. Over framing is to be strapped to trusses below. Missing Gable end bracing and blocking - Detail page 6/7. DO1 truss missing strap at front post. Missing engineer trusses at A05,A08,A09. CG2, CG3 not strapped to wall below. Front wall trusses missing straps at bearing wall. Please specify R1, R2, R3/R4 are on the connector schedule. Have architect specify hold down anchors at girder trusses. Check that all threads at bearing walls at all locations. 3-25-22 Missing engineer trusses at A05,A08,A09. CG1, CG2 not strapped to wall below and not shown in connector schedule. Please specify R1, R2, R3/R4 are on the connector schedule. Have architect specify hold down anchors at girder trusses. Check that all threads at bearing walls at all locations (interior garage walls maximum OC spacing of all-thread exceeded, calls for a max of 6 ft on wall details) overframing not tied to framing below | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/25/2022 | Disapproved -FEE REQUIRED | LMILLER |
| Note: THIS IS A REINSPECTION Piggy back trusses missing hold down anchors. Over framing is to be strapped to trusses below. Missing Gable end bracing and blocking - Detail page 6/7. DO1 truss missing strap at front post. Missing engineer trusses at A05,A08,A09. CG2, CG3 not strapped to wall below. Front wall trusses missing straps at bearing wall. Please specify R1, R2, R3/R4 are on the connector schedule. Have architect specify hold down anchors at girder trusses. Check that all threads at bearing walls at all locations. 3-25-22 Missing engineer trusses at A05,A08,A09. CG1, CG2 not strapped to wall below and not shown in connector schedule. Please specify R1, R2, R3/R4 are on the connector schedule. Have architect specify hold down anchors at girder trusses. Check that all threads at bearing walls at all locations (interior garage walls maximum OC spacing of all-thread exceeded, calls for a max of 6 ft on wall details) overframing not tied to framing below | |||
| WINDOW NAILING | 03/25/2022 | APPROVED | LMILLER |
| Note: added at the request of site manager (approved) | |||
| ROOF VALLEY & METAL | 01/14/2022 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/08/2021 | Disapproved - NO FEE | AGAETANO |
| Note: Piggy back trusses missing hold down anchors. Over framing is to be strapped to trusses below. Missing Gable end bracing and blocking - Detail page 6/7. DO1 truss missing strap at front post. Missing engineer trusses at A05,A08,A09. CG2, CG3 not strapped to wall below. Front wall trusses missing straps at bearing wall. Please specify R1, R2, R3/R4 are on the connector schedule. Have architect specify hold down anchors at girder trusses. Check that all threads at bearing walls at all locations. Roof sheathing and wall sheathing pass inspection. | |||
| FOUND SURVEY APPROVED (OFFICE) | 11/15/2021 | APPROVED | TDOAK |
| MONOLITHIC SLAB | 11/01/2021 | APPROVED | RMARTIN |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/18/2021 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 09/01/2021 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/20/2023 | 01/20/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Building review not required. | |||
| ELEC | COMPLETE | 01/20/2023 | 01/20/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/29/2022 | 03/30/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 03/22/2022 | 03/22/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: Repeat Comment 1. Gas riser diagram appears to be exactly the same as the original diagram. Please identify the change(s) made for clarity per FBC 7th Ed. Sec. 107.3. Gas Riser is lastly dated 12/8/2021. | |||
| BLD | COMPLETE | 03/22/2022 | 03/22/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 03/22/2022 | 03/24/2022 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/02/2022 | 02/03/2022 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Revision: Revision Form only indicates "Revised Plan". This revision appears to be an additional Sheet 2 of 8 deleting the AC Duct Layout and Electrical Load Calculations as shown on Sheet 2 of 7. You can delete the AC Duct layout because there is another copy on AC Energy calculation. The Electical Load Calculation cannot be deleted because there would be NO RECORD of it. Please clarify the revision narrative of what you intend to do - FBC 7th Ed. Sec. 107.3. | |||
| PLUM | HOLD | 02/02/2022 | 02/03/2022 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Revision: Gas riser diagram appears to be exactly the same as the original diagram. Please identify the change(s) made for clarity per FBC 7th Ed. Sec. 107.3. | |||
| PLUM | COMPLETE | 12/09/2021 | 12/13/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/15/2021 | 11/15/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/15/2021 | 11/15/2021 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/21/2021 | 09/21/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/21/2021 | 09/29/2021 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/21/2021 | 09/21/2021 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/23/2021 | 07/23/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/23/2021 | 07/29/2021 |
| Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/23/2021 | 07/23/2021 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| PLENV | COMPLETE | 07/22/2021 | 07/22/2021 |
| Note: Released By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM The Approved After Action Report has been accepted | |||
| BLD | COMPLETE | 06/21/2021 | 06/24/2021 |
| Note: Released By: JPI | |||
| PLENV | HOLD | 06/21/2021 | 06/22/2021 |
| Note: Held By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM Staff appreciates the update on the Gopher Tortoise relocation. Please provide Approved After Action Report after relocation activities have been completed. | |||
| ELEC | COMPLETE | 06/21/2021 | 06/21/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/21/2021 | 06/21/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/21/2021 | 06/22/2021 |
| Note: Held By: ESTELLE LENS - (386)986-3751 - Repeat comment: Please provide the driveway width at the garage door. (along the garage door) | |||
| PLENV | HOLD | 05/14/2021 | 05/19/2021 |
| Note: Held By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM Staff conducted a site visit on 5/19/2021 and noted Potentially Occupied Gopher Tortoise burrows. Please either provide a Gopher Tortoise survey by a QEP showing the burrow outside of construction activities or provide the Approved After Action Report after relocation activities have been completed. | |||
| PLFM | COMPLETE | 05/14/2021 | 05/14/2021 |
| Note: Released By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM According to the Site Plan submitted on 5/12/21 the structure will be outside of the Special Flood Hazard Area. No elevation certificates will be required. | |||
| BLD | HOLD | 05/12/2021 | 05/16/2021 |
| Note: Held By: JPI 1. Product approval for swing door, widndows and soffit are not valid. Please provide another selection. 2. Indicate slope of garage floor. 3. Provide size of attic access. 4. Provide foundation detail for garage to dwelling wall. 5. Provide mullion product approval number. 6. Incorrect Code citation on drawings 3 thru 7. 7. Provide garage to dwelling fire separation details. 8. Provide mixed construction details. 9. Provide dutch gable end details. | |||
| CUSVC | COMPLETE | 05/12/2021 | 05/14/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | HOLD | 05/12/2021 | 05/12/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Outlets in the garage need to be GFCI protected. NEC 2017 210.8 Reference the 2017 NEC | |||
| ENGIN1 | COMPLETE | 05/12/2021 | 05/12/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 05/12/2021 | 05/17/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 05/12/2021 | 05/13/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide Energy Calcs from 2020 7Th edition code cycle 2. Plans show Frame wall w/ R19 Insulation and R30 insulation attic. Energy Calcs show Block wall with R5 and Spray foam R20 on roof deck. Revise to match. 3. Square footage on Energy Calcs does not match the house plans. | |||
| SW1 | COMPLETE | 05/12/2021 | 05/18/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/12/2021 | 05/14/2021 |
| Note: Held By: ESTELLE LENS - (386)986-3751 - The proposed residence does not meet the 10' left side setback. Please provide the driveway width at the garage door. Need to show the A/C pad on the site plan. The driveway configuration on the landscape plan does not match the site plan. (A/C pad is shown on the landscape plan but not on the site plan.) The right side elevation is labeled as left side. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 02/13/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 02/13/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 02/13/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 02/13/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/13/2023 |
| CONNECTION FEES | ¤25.00 | 08/31/2021 |
| METER - DEPOSIT | ¤60.00 | 08/31/2021 |
| WATER-METER | ¤441.07 | 08/31/2021 |
| ADMIN FEE | ¤20.00 | 08/31/2021 |
| BUILDING DISCOUNT 100% | (¤1,880.00) | 08/31/2021 |
| ELECTRIC FEE | ¤300.00 | 08/31/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 08/31/2021 |
| IMPACT FEE FIRE | ¤367.00 | 08/31/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 08/31/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 08/31/2021 |
| IMPACT FEE TRANSPORTATION | ¤3,139.00 | 08/31/2021 |
| MECHANICAL FEE | ¤300.00 | 08/31/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 08/31/2021 |
| PLAN CHECK FEE | ¤160.00 | 08/31/2021 |
| PLUMBING FEE | ¤300.00 | 08/31/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤800.00 | 08/31/2021 |
| SITE PLAN 20 | ¤20.00 | 08/31/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 08/31/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 08/31/2021 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/31/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤94.17) | 08/31/2021 |
| SEWER INSPECTION | ¤25.00 | 08/31/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 08/31/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 08/31/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤17,085.54 |