I want to search for...

Permit #2021051504

Permit Details

Status: COED

Parcel Id: 07-11-31-7057-00860-0080
CONDITIONED SPACE: 1215 sqft
CONDITIONED SPACE: 1215 sqft
GARAGE: 280 sqft
GARAGE: 280 sqft
OPENED PORCH (WITH ROOF) : 118 sqft
OPENED PORCH (WITH ROOF) : 118 sqft
OPENED PORCH (WITH ROOF) : 22 sqft
OPENED PORCH (WITH ROOF) : 22 sqft
Total Square Footage: 3270 sqft
Block: 00860
Subdivision: -
Job Phone: 863-845-6967
Location Address: 176 ULLIAN TR
Type: DU - DUPLEX
Issue Date: 02/01/2022
NOC: RECORDED
Applicant name: LARRY SHERWIN THOMPSON
Owner: CARPENTER COMPANIES FLORIDA LLC

Address

142 WEST PLATT ST STE 116

TAMPA, FL 33606

Lot: 0080
Contracted Stated Job Value: ¤150,000.00
Job Description: DUPLEX
Type: CN

Contractor

THOMCO OF FLORIDA LLC
Status Location Address State License Number Phone
INACTIVE

6381 ROBERTS RD

KATHLEEN, FL 33849

CGC1513647 (Exp: 08/31/2024) 863-845-6967

Sub Contractors

JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/04/2023 FINAL APPROVED BTAYLOR
U -UTILITY RESIDENTIAL FINAL 04/04/2023 FINAL APPROVED JHARDING
ROW - FINAL INSPECTION 04/03/2023 FINAL APPROVED PFLANAGAN
Note: ** 03/07/23 REVIEW NOTES IN FIELD SURVEY FOR CORRECTIONS NEEDED BEFORE FINAL ROW IS APPROVED
U-CROSS CONNECTION 04/03/2023 APPROVED - AS NOTED JHARDING
Note: No cross connections.
ELECTRIC - EARLY POWER 03/08/2023 APPROVED - AS NOTED BTAYLOR
Note: 3-8-23 1. Emailed FPL at 2:51.
ROW - FINAL APRON (AFTER POUR) 03/07/2023 FINAL APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/07/2023 APPROVED EMADISON
Note: ** 03/07/23 CORRECTIONS MADE __________________________________________________________________________________________________________________________ 3/2/2023 - PREVIOUS INSPECTION NOTES ** 03/02/23 FINAL SURVEY IS SUBMITTED AFTER FINAL GRADE HAS BEEN SET AND THE SOD HAS BEEN LAID THEN YOUR FINAL SURVEY SHOTS ARE ON TOP OF THE SOD THAT HAS BEEN SET. ** RESUBMIT WHEN SITE HAS BEEN PREPARED FOR A FINAL SURVEY
ROW FIELD SURVEY /GRADING CERTIFICATION 03/07/2023 APPROVED EMADISON
Note: ** 03/07/23 LEFT SIDE PROPERTY LINE NEED TO EXTEND SOD TO COVER ADJACENT PROPERTY THAT WAS IMPACTED FROM YOUR CONSTRUCTION. COVER ALL AREAS OF BARE EARTH **REMOVE SILT FENCE ON LEFT SIDE COVERED WITH SOD
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/02/2023 Disapproved - NO FEE EMADISON
Note: ** 03/02/23 FINAL SURVEY IS SUBMITTED AFTER FINAL GRADE HAS BEEN SET AND THE SOD HAS BEEN LAID THEN YOUR FINAL SURVEY SHOTS ARE ON TOP OF THE SOD THAT HAS BEEN SET. ** RESUBMIT WHEN SITE HAS BEEN PREPARED FOR A FINAL SURVEY
ROW- PRE-APRON (PRE-POUR) 01/26/2023 APPROVED PFLANAGAN
Note: IT'S THE CONTRACTORS RESPONSIBILITY TO CHECK THE CULVERT PIPE ELEVATIONS BEFORE POURING CONCRETE FOR THE DRIVEWAY. ----------------------------------------------------------------------------- 1/24/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO COMPACT THE ROCK SO THERE ARE NOT SO MANY VOIDS AROUND THEM 2) NEED TO HAVE THE FLAIRS 3' WIDE
ROW- PRE-APRON (PRE-POUR) 01/24/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO COMPACT THE ROCK SO THERE ARE NOT SO MANY VOIDS AROUND THEM 2) NEED TO HAVE THE FLAIRS 3' WIDE
ROW- PRE-APRON (PRE-POUR) 01/23/2023 CANCELLED BY APPLICANT WEB
U - SEWER TIE IN 12/16/2022 APPROVED MGIBSON
GRAVITY SEWER TEST 12/16/2022 APPROVED MGIBSON
INSULATION 11/17/2022 APPROVED BTAYLOR
LATH/BRICK/ WATER BARRIER 11/16/2022 APPROVED BTAYLOR
ALL ROUGH 11/15/2022 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/14/2022 APPROVED BTAYLOR
Note: New inspection due to canceled inspection 9/16/2022 - PREVIOUS INSPECTION NOTES THIS IS A REINSPECTION WE TYPICALLY DO NOT DO THIS INSPECTION SEPERATE, ITS ALL IN ONE ROOF SHEATHING,BRACES AND TIES WILL NEED TO BE ALL DONE IN THE FUTURE 9-16-22 1. Strap in right unit not nailed off. 2.Gagles not strapped. 3. Bearing walls not per detail.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/04/2022 CANCELLED BY APPLICANT WEB
Note: 9/16/2022 - PREVIOUS INSPECTION NOTES THIS IS A REINSPECTION WE TYPICALLY DO NOT DO THIS INSPECTION SEPERATE, ITS ALL IN ONE ROOF SHEATHING,BRACES AND TIES WILL NEED TO BE ALL DONE IN THE FUTURE 9-16-22 1. Strap in right unit not nailed off. 2.Gagles not strapped. 3. Bearing walls not per detail.
FIREWALL FINAL 10/05/2022 APPROVED BTAYLOR
FIREWALL DRYWALL NAILING 09/23/2022 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/16/2022 Disapproved - NO FEE BTAYLOR
Note: THIS IS A REINSPECTION WE TYPICALLY DO NOT DO THIS INSPECTION SEPERATE, ITS ALL IN ONE ROOF SHEATHING,BRACES AND TIES WILL NEED TO BE ALL DONE IN THE FUTURE 9-16-22 1. Strap in right unit not nailed off. 2.Gagles not strapped. 3. Bearing walls not per detail.
ROOF VALLEY & METAL 08/01/2022 APPROVED BTAYLOR
WALL SHEATHING 07/14/2022 APPROVED RMARTIN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/14/2022 PARTIALLY APPROVED RMARTIN
Note: WE TYPICALLY DO NOT DO THIS INSPECTION SEPERATE, ITS ALL IN ONE ROOF SHEATHING,BRACES AND TIES WILL NEED TO BE ALL DONE IN THE FUTURE
WATER METER INSTALLATION REQUEST 07/11/2022 APPROVED CSTONE
Note: THIS IS A REINSPECTION ADDED ON 4/12/2022 10:57:22 AM LOT NOT CLEAR-TRUSSES
TIE BEAM / LINTEL 06/27/2022 APPROVED LMILLER
TIE BEAM / LINTEL 06/24/2022 CANCELLED BY APPLICANT WEB
FOUND SURVEY APPROVED (OFFICE) 06/03/2022 APPROVED TBAKER
MONOLITHIC SLAB 05/27/2022 APPROVED LMILLER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION MANY AREAS WASHED IN, NEED TO CLEAN OUT FOOTERS 5-26-22 Revision needed 1. Missing details (check all) and missing footing on plans Just behind back of garage wall (not in plans). 2. There are details called out on the foundation sheet that are not in the plans 3. Some areas still do not have the 3 inch clearance needed for reinforcing steel (all this is needed to perform the inspection) 5-27-22 notes above resolved inspection was set for today by contra ctor request .
MONOLITHIC SLAB 05/26/2022 Disapproved - NO FEE LMILLER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION MANY AREAS WASHED IN, NEED TO CLEAN OUT FOOTERS 5-26-22 Revision needed 1. Missing details (check all) and missing footing on plans Just behind back of garage wall (not in plans). 2. There are details called out on the foundation sheet that are not in the plans 3. Some areas still do not have the 3 inch clearance needed for reinforcing steel (all this is needed to perform the inspection)
MONOLITHIC SLAB 05/25/2022 CANCELLED BY APPLICANT DCUSHING
Note: THIS IS A REINSPECTION MANY AREAS WASHED IN, NEED TO CLEAN OUT FOOTERS
MONOLITHIC SLAB 05/23/2022 Disapproved - NO FEE RMARTIN
Note: MANY AREAS WASHED IN, NEED TO CLEAN OUT FOOTERS
PLUMBING 1ST ROUGH UNDERGROUND 05/12/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 04/08/2022 Disapproved - NO FEE CSTONE
Note: LOT NOT CLEAR-TRUSSES

Review History

Department Status Date In Date Out
MECH HOLD 03/09/2023 03/09/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Entire heatload is not readable. Please resubmit. Energy Calcs
MECH COMPLETE 03/09/2023 03/09/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 02/21/2023 02/21/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Rename your files to final survey
ENGIN1 COMPLETE 08/08/2022 08/08/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 08/08/2022 08/08/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/03/2022 06/03/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/03/2022 06/03/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 04/13/2022 04/13/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 02/09/2022 02/16/2022
Note: Released By: ALYSSA ROSCOE - -
ZON COMPLETE 10/01/2021 10/01/2021
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/01/2021 10/04/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 10/01/2021 10/08/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
ZON HOLD 09/22/2021 09/23/2021
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Driveways must be a minimum of 16ft in width on both sides so if one driveway for both it must be 32ft wide within the first 20ft of the garage. Please show this on the site plan for review. Noticed in notes on site plan that driveway may be asphalt millings or crushed concrete fines. Driveways must be solid concrete or pavers per the ldc. Please correct site plan/survey to specify the correct approved material. The A/C units are in the back on landscape plan, and on the sides on the floor plan and site plan. All must match.
ENGIN1 COMPLETE 09/22/2021 09/23/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 09/22/2021 09/29/2021
Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM
ZON HOLD 09/08/2021 09/08/2021
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENTS: Need to fix the legal description on the survey and site plan. (Missing the section number – Section 57) The minimum driveway width is 16 feet per unit – to total 32’. Need to provide the widths of the walkways on the site plan. The A/C units are in the back on the site plan and landscape plan, and on the sides on the floor plan. All must match.
ENGIN1 COMPLETE 09/08/2021 09/08/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 09/08/2021 09/15/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
MECH COMPLETE 08/19/2021 08/19/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/19/2021 08/19/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 08/19/2021 08/20/2021
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENTS: Need to fix the legal description on the survey and site plan. (Missing the section number.) The minimum driveway width is 16 feet per unit – to total 32’. Need to provide the widths of the walkways on the site plan. Please upload the correct landscape plan for review. (The uploaded plan is for a single family residence.) The A/C units are in the back on the site plan, and on the sides on the floor plan. All must match (including the landscape plan.)
BLD COMPLETE 08/19/2021 08/19/2021
Note: Released By: JPI
SW1 COMPLETE 08/19/2021 08/26/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
SWALE COMPLETE 05/25/2021 08/25/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 05/25/2021 05/31/2021
Note: Held By: JPI 1. Provide design loads. 2. Product approval number for single hung window is for a nail fin window, for frame installation. Dwelling is a block home. Clarify.
CUSVC COMPLETE 05/25/2021 05/26/2021
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 05/25/2021 05/26/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 HOLD 05/25/2021 05/26/2021
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Site plan elevations are off by approx. -1.50'; please revise
LOCATE COMPLETE 05/25/2021 06/01/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 05/25/2021 05/26/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy calcs and heatload for both sides of duplex
SW1 HOLD 05/25/2021 06/02/2021
Note: Held By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM “The minimum driveway width is 16 feet for at least 20 feet from the garage doors.
ZON HOLD 05/25/2021 05/28/2021
Note: Held By: ESTELLE LENS - (386)986-3751 - Need to fix the legal description on the survey and site plan. (Missing the section number.) Must show all platted easements on the site plan and survey. The minimum driveway width is 16 feet for at least 20 feet from the garage doors. They may then be reduced to a minimum of 10 feet to the roadway. Need to provide the driveway material on the site plan. Need to provide the widths and material of the walkways on the site plan. Please upload the correct landscape plan for review. (The uploaded plan is for a single family residence.) Please provide the roof material and color where requested on the color sheet. Please provide the exterior material where requested on the color sheet. The color of the garage door must be an earth tone as provided on the color sheet. Please provide a color sample for Bowman Blue so it may be determined whether it is an earth tone. The A/C units are in the back on the site plan, and on the sides on the floor plan. All must match (including the landscape plan.)

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 04/04/2023
PLAN REVIEW - REVISION ¤32.50 04/04/2023
CONTRACTOR CHANGE ¤20.00 04/04/2023
CONTRACTOR CHANGE ¤20.00 04/04/2023
SW ENG REINSPECTION 30 ¤30.00 04/04/2023
WATER -IRRIGATION INSPECTION ¤25.00 02/16/2022
CONNECTION FEES ¤1,077.88 02/16/2022
METER - DEPOSIT ¤60.00 02/16/2022
WATER- TURN ON ¤25.00 02/16/2022
SEWER CAPITAL FACILITY ¤4,939.76 02/16/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 02/16/2022
SEWER CAPITAL FACILITY ¤4,939.76 02/01/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 02/01/2022
WATER- TURN ON ¤25.00 02/01/2022
WATER- TURN ON ¤25.00 02/01/2022
ADMINISTRATIVE RESIDENTIAL ¤20.00 02/01/2022
INSPECTION- ELECTRICAL ¤242.40 02/01/2022
INSPECTION - MECHANICAL ¤242.40 02/01/2022
INSPECTION - PLUMBING ¤242.40 02/01/2022
PLAN REVIEW - RESIDENTIAL ¤121.60 02/01/2022
WATER-METER ¤467.09 02/01/2022
METER - DEPOSIT ¤60.00 02/01/2022
METER - DEPOSIT ¤60.00 02/01/2022
CONNECTION FEES ¤1,077.88 02/01/2022
CONTRACTOR CHANGE ¤40.00 02/01/2022
3% PARKS IMPACT FEE CREDIT (¤71.95) 02/01/2022
NEW RESIDENTIAL INSPECTIONS ¤608.00 02/01/2022
SITE PLAN 20 ¤20.00 02/01/2022
SURCHARGE FS 533.721 ¤2.00 02/01/2022
SURCHARGE - FS 468.631 ¤2.00 02/01/2022
STORM WATER PERMIT FEES ¤80.00 02/01/2022
3% TRANS IMPACT FEE CREDIT (¤79.98) 02/01/2022
SEWER INSPECTION ¤25.00 02/01/2022
BUILDING DISCOUNT 100% (¤1,476.80) 02/01/2022
3% FIRE IMPACT FEE CREDIT (¤22.02) 02/01/2022
IMPACT FEE FIRE ¤734.00 02/01/2022
IMPACT FEE PARKS ¤2,398.24 02/01/2022
IMPACT FEE SCHOOL ¤7,200.00 02/01/2022
IMPACT FEE TRANSPORTATION ¤2,666.00 02/01/2022
WATER -IRRIGATION INSPECTION ¤25.00 02/01/2022
WATER -IRRIGATION INSPECTION ¤25.00 02/01/2022
Fees Total Due: ¤0.00 Total Paid: ¤33,213.66