I want to search for...
Permit #2021051731
Permit Details
Status: COED
| Parcel Id: 07-11-31-7029-00770-0040 |
| CONDITIONED SPACE: 1351 sqft |
| GARAGE: 631 sqft |
| OPENED PORCH (WITH ROOF) : 46 sqft |
| Total Square Footage: 2028 sqft |
| Block: 00770 |
| Subdivision: 2209 - SECTION 29-ROYAL PALMS |
| Job Phone: 863-845-6967 |
| Location Address: 16 RYMSHAW DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/18/2021 |
| NOC: RECORDED |
| Applicant name: LARRY SHERWIN THOMPSON |
| Owner: CARPENTER COMPANIES FLORIDA |
|
Address 142 WEST PLATT STREET STE 116 TAMPA, FL 33606 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
THOMCO OF FLORIDA LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
6381 ROBERTS RD KATHLEEN, FL 33849 |
CGC1513647 (Exp: 08/31/2024) | 863-845-6967 |
Sub Contractors
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
ROBERT MICHAEL RENNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
531 CODISCO WAY SANFORD, FL 32771 |
CAC051477 (Exp: 08/31/2026) | 407-333-2665 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/10/2022 | FINAL APPROVED | JWALKER |
| Note: 10/7/2022 - PREVIOUS INSPECTION NOTES 1. Need to seal hole in wall at air handler (backside of garage wall), FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 2. Master path sink plunger is not operable P2705.1 – 8 3. Need approved Energy Calcs on site that match the units installed | |||
| U-CROSS CONNECTION | 10/10/2022 | APPROVED - AS NOTED | LFITZGERALD |
| Note: has potable irrigation with PVB installed-no cross connection | |||
| ROW - FINAL APRON (AFTER POUR) | 10/07/2022 | APPROVED - AS NOTED | GBERTOLA |
| Note: BUILDER WILL BE ADDING HOTPATCH ASAP 7 DAYS CARPENTER HOMES WILL BE RESPONSIBLE FOR COMPLETION | |||
| BLD - BUILDING FINAL | 10/07/2022 | Disapproved -FEE REQUIRED | LMILLER |
| Note: 1. Need to seal hole in wall at air handler (backside of garage wall), FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 2. Master path sink plunger is not operable P2705.1 – 8 3. Need approved Energy Calcs on site that match the units installed | |||
| ROW - STORMWATER FINAL | 10/07/2022 | APPROVED - AS NOTED | GBERTOLA |
| Note: BULIDER WILL ADD SOD TO LEFT EDGE OF PROPERTY WITH IN 7 DAYS | |||
| U -UTILITY RESIDENTIAL FINAL | 10/07/2022 | FINAL APPROVED | LFITZGERALD |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/06/2022 | APPROVED | RGROSS |
| Note: 10/3/2022 - PREVIOUS INSPECTION NOTES 10/03/22 check the numbers on the inverts they are out of tolerance | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/06/2022 | APPROVED | RGROSS |
| Note: 10/3/2022 - PREVIOUS INSPECTION NOTES 10/03/22 check the numbers on the inverts they are out of tolerance | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/03/2022 | Disapproved - NO FEE | GBERTOLA |
| Note: 10/03/22 check the numbers on the inverts they are out of tolerance | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/03/2022 | Disapproved - NO FEE | GBERTOLA |
| Note: 10/03/22 check the numbers on the inverts they are out of tolerance | |||
| U - SEWER TIE IN | 09/07/2022 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 09/07/2022 | APPROVED | MGIBSON |
| ELECTRIC - EARLY POWER | 09/07/2022 | APPROVED - AS NOTED | JWALKER |
| Note: Emailed FPL 2:38 pm | |||
| ROW- PRE-APRON (PRE-POUR) | 09/02/2022 | APPROVED - AS NOTED | GBERTOLA |
| Note: 09/02/22=AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| ROW- PRE-APRON (PRE-POUR) | 09/01/2022 | CANCELLED BY APPLICANT | GBERTOLA |
| ROW- PRE-APRON (PRE-POUR) | 08/26/2022 | CANCELLED BY APPLICANT | WEB |
| PEP TANK INSTALLATION REQUEST | 08/04/2022 | APPROVED | CSTONE |
| INSULATION | 07/11/2022 | APPROVED | RMARTIN |
| ALL ROUGH | 07/07/2022 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION Missing engineering on truss T04S, T06S, and T07BS The X bracing and the continuous lateral bracing on minimum required Page 6 of the prints has not been installed The above items were listed at roof brace inspection and have not been corrected. The ground to UFER has not been installed. Line set not installed. The 1 1/2 PVC vent line above the tub area is to slope downward toward the drain and be supported a 4' o.c. Bath exhaust duct seal where the duct meets the fan. big hole. | |||
| ALL ROUGH | 06/29/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: Missing engineering on truss T04S, T06S, and T07BS The X bracing and the continuous lateral bracing on minimum required Page 6 of the prints has not been installed The above items were listed at roof brace inspection and have not been corrected. The ground to UFER has not been installed. Line set not installed. The 1 1/2 PVC vent line above the tub area is to slope downward toward the drain and be supported a 4' o.c. Bath exhaust duct seal where the duct meets the fan. big hole. | |||
| HVAC ROUGH | 06/28/2022 | CANCELLED BY INSPECTOR | CPISCITELLI |
| Note: Need to call in an ALL ROUGH | |||
| PLUMBING 2ND ROUGH | 06/28/2022 | CANCELLED BY INSPECTOR | MGIBSON |
| Note: CITY OF PALM COAST DOESN'T DO SINGLE TRADE INSPECTIONS ON SINGLE FAMILY HOMES ON COMMERCIAL PROJECTS WE DO | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/24/2022 | APPROVED - AS NOTED | JWALKER |
| Note: THIS IS A REINSPECTION Missing engineering on truss T04S, T06S, and T07BS The X bracing and the continuous lateral bracing on minimum required Page 6 of the prints has not been installed Check at ALL ROUGH, | |||
| PLUMBING 2ND ROUGH | 06/23/2022 | CANCELLED BY INSPECTOR | MGIBSON |
| Note: MUST CALL IN ALL ROUGH INSPECTION, AS WE DO NOT DO SINGLE TRADE INSPECTIONS FOR SINGLE FAMILY HOMES | |||
| FRAMING | 06/21/2022 | APPROVED | JWALKER |
| Note: Bearing walls , trusses etc. are checked at Roof braces trusses and tie downs. | |||
| LATH/BRICK/ WATER BARRIER | 06/06/2022 | APPROVED | JWALKER |
| ROOF VALLEY & METAL | 05/09/2022 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION Drip edge is not installed. | |||
| ROOF VALLEY & METAL | 05/04/2022 | Disapproved - NO FEE | JWALKER |
| Note: Drip edge is not installed. | |||
| WALL SHEATHING | 04/28/2022 | APPROVED | JWALKER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/28/2022 | Disapproved - NO FEE | JWALKER |
| Note: Missing engineering on truss T04S, T06S, and T07BS Truss T07BS has a broken bottom chord and will need to be fixed as per Mitek details. The X bracing and the continuous lateral bracing on minimum required Page 6 of the prints has not been installed Truss T24 is missing 1 heta strap at both ends. Girder Truss T22B is missing the 2 required LGT anchors at each end. Roof sheating passes inspection Down cells pass. | |||
| FOUND SURVEY APPROVED (OFFICE) | 04/27/2022 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 03/01/2022 | APPROVED | JWALKER |
| MONOLITHIC SLAB | 02/17/2022 | APPROVED | MKRASKI |
| MONOLITHIC SLAB | 02/14/2022 | CANCELLED BY APPLICANT | WEB |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/04/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 02/02/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 10/07/2022 | 10/07/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/07/2022 | 10/07/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/19/2022 | 08/19/2022 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Per the Land Development Code Chapter 13302.06.B. 1.Wall or garage door colors.a.Light pastel colors and white. Acceptable light pastel colors and white shall have LRV of 80 or greater.b.Earth tones. Earth tones include shades of brown, brown-taupe or sandy-taupe, beige, terra cotta, olive, sage and gray. Acceptable earth tone shades shall have a LRV of 25 or greater. The paint color you resubmitted as a revision does not meet the LDC. | |||
| BLD | COMPLETE | 06/28/2022 | 06/29/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 06/24/2022 | 06/24/2022 |
| Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM RENAME TO TRUSS.PDF | |||
| BLD | COMPLETE | 06/21/2022 | 06/21/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/27/2022 | 04/27/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/27/2022 | 04/27/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 04/13/2022 | 04/13/2022 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Formboard survey is not acceptable as foundation survey. Please provide a foundation survey showing location, dimensions and elevations of finished concrete slab/foundation. | |||
| ZON | COMPLETE | 04/13/2022 | 04/13/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/18/2021 | 10/25/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/18/2021 | 10/18/2021 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/22/2021 | 09/22/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/22/2021 | 09/23/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 09/22/2021 | 09/29/2021 |
| Note: Held By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM Adjacent driveway culverts and drainage features: Site Plan must include the inverts of adjacent developed property driveway culverts and any other drainage features within 100 feet of the property lines. (A) See uploaded Stormwater checklist in attachments for correction. Make corrections on all unchecked items. | |||
| SW1 | COMPLETE | 09/08/2021 | 09/15/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 09/08/2021 | 09/08/2021 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENTS: Site Plan: - Need width of the front walkway. Landscape Plan: - 4 foundation plantings are required in the rear facing the public right of way. | |||
| BLD | COMPLETE | 09/08/2021 | 09/11/2021 |
| Note: Released By: JPI | |||
| BLD | HOLD | 06/24/2021 | 06/24/2021 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM PLAN REVIEW COMMENT NO. 1 FROM PREVIOUS REVIEW HOLD HAS BEEN REMOVED. PLEASE RESPOND TO REMAINING COMMENT BELOW. 2. Product Approval Spec Sheet provided, and Product Approval #’s provided for on drawings, page PA. Numbers do not match for multiple products. Please review and either provide matching numbers or eliminate one. | |||
| BLD | HOLD | 05/27/2021 | 05/31/2021 |
| Note: Held By: JPI 1. Continuing comment. Correct sheet numbering and/or append missing sheets. 2. Product Approval Spec Sheet provided, and Product Approval #’s provided for on drawings, page PA. Numbers do not match for multiple products. Please review and either provide matching numbers or eliminate one. | |||
| CUSVC | COMPLETE | 05/27/2021 | 06/02/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 05/27/2021 | 06/01/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/27/2021 | 05/27/2021 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 05/27/2021 | 06/02/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/27/2021 | 05/28/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 05/27/2021 | 06/04/2021 |
| Note: Held By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM Must show proposed elevations down each side of the property line with directional arrows. | |||
| ZON | HOLD | 05/27/2021 | 06/04/2021 |
| Note: Held By: ESTELLE LENS - (386)986-3751 - Site Plan: - Need material of driveway. - Need material and width of the walkway. Landscape Plan: - Need to upload the correct landscape plan. (This one is garage left. The site plan and floor plan are garage right.) - 4 foundation plantings are required on the right side. - 4 foundation plantings are required in the rear facing the public right of way. - 4 credit trees are required. One must be a shade tree. Need to specify type and location of proposed trees. (Pine trees are non credit.) Color Sheet: - Need to provide the manufacturer (along with the color) of the proposed exterior paint where requested on the color sheet. - Need to provide the exterior material where requested on the color sheet. (Stucco and siding?) - Need include a note on the color sheet stating that the siding and the stucco will be the same color. Elevations: - Banding is required around the front door (as well as the windows and garage door.) - Banding is required around the rear windows and doors facing the public right of way. | |||
| SWALE | COMPLETE | 05/27/2021 | 08/09/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 10/10/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/10/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/07/2022 |
| PLAN REVIEW - REVISION | ¤32.50 | 10/07/2022 |
| CONTRACTOR CHANGE | ¤20.00 | 10/07/2022 |
| CONTRACTOR CHANGE | ¤20.00 | 10/07/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 11/18/2021 |
| BUILDING DISCOUNT 100% | (¤947.60) | 11/18/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 11/18/2021 |
| IMPACT FEE FIRE | ¤367.00 | 11/18/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 11/18/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 11/18/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 11/18/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 11/18/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 11/18/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 11/18/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤356.00 | 11/18/2021 |
| SITE PLAN 20 | ¤20.00 | 11/18/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 11/18/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 11/18/2021 |
| STORM WATER PERMIT FEES | ¤80.00 | 11/18/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 11/18/2021 |
| SEWER CREDIT | (¤1,342.00) | 11/18/2021 |
| SEWER INSPECTION | ¤25.00 | 11/18/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 11/18/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 11/18/2021 |
| CONNECTION FEES | ¤1,017.83 | 11/18/2021 |
| METER - DEPOSIT | ¤60.00 | 11/18/2021 |
| METER - DEPOSIT | ¤60.00 | 11/18/2021 |
| WATER-METER | ¤441.07 | 11/18/2021 |
| WATER- TURN ON | ¤25.00 | 11/18/2021 |
| WATER- TURN ON | ¤25.00 | 11/18/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤20.00 | 11/18/2021 |
| INSPECTION- ELECTRICAL | ¤166.80 | 11/18/2021 |
| INSPECTION - MECHANICAL | ¤166.80 | 11/18/2021 |
| INSPECTION - PLUMBING | ¤166.80 | 11/18/2021 |
| PLAN REVIEW - RESIDENTIAL | ¤71.20 | 11/18/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,565.50 |