I want to search for...
Permit #2021060089
Permit Details
Status: FINAL
| Parcel Id: 22-11-31-0000-02020-0200 |
| Block: 02020 |
| Subdivision: - |
| Job Phone: (386)446-6426 |
| Location Address: 2001 WATERSIDE PKWY |
| Type: CAS - COMMERCIAL ACCESSORY STRUCTURE |
| Issue Date: 07/30/2021 |
| NOC: RECORDED |
| Applicant name: SCOTT DALE SOWERS |
| Owner: GRAND HAVEN COMMUNITY DEVELOPMENT DISTRICT C/O WRA |
|
Address 2300 GLADES ROAD, SUITE 410W BOCA RATON, FL 33431 |
| Lot: 0200 |
| Contracted Stated Job Value: ¤79,062.00 |
| Job Description: 2 - Pickle Ball Courts at Grand Haven Village Center |
| Type: CN |
Contractor
S E CLINE CONSTRUCTION, INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 354425 PALM COAST, FL 32137 |
CGC061947 (Exp: 08/31/2028) | (386)446-6426 | (386)446-6481 |
Sub Contractors
MARK JOHN LUTCZA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
26 ROYAL LEAF LANE PALM COAST, FL 32164 |
EC13005145 (Exp: 08/31/2026) | 386-586-0770 |
Inspection History
| Type | Request Date | Result | Inspector |
| LDSC- LANDSCAPE FINAL | 12/17/2021 | APPROVED | JHARDING |
| ELECTRIC FINAL | 12/13/2021 | APPROVED | JMUNSON |
| ACCESSORY FINAL | 12/13/2021 | FINAL APPROVED | LMILLER |
| BLD - UNDERGROUND SITE LIGHTING CONDUITS | 08/31/2021 | APPROVED | RMARTIN |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 07/15/2021 | 07/15/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/15/2021 | 07/29/2021 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 06/21/2021 | 06/21/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. List breaker size. 2. List sub contractor on correction form with name and license number. 2nd request | |||
| BLD | HOLD | 06/21/2021 | 07/06/2021 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM 1. REPEAT COMMENT. NO RESPONSE PROVIDED BY THE ARCHITECT. PLEASE RESPOND TO COMMENT: Is there a plan sheet C5.0? Plan sheet C3.0 mentions a sidewalk detail on Plan Sheet C5.00. Please provide this plan sheet if it exists. 2. REPEAT COMMENT. NO RESPONSE PROVIDED BY THE ARCHITECT. PLEASE RESPOND TO COMMENT: This recreation facility must be connected to remainder of site by accessible route complying with Section 206, 402, 403. . Provide notes indicating this facility is on a connected accessible exterior route that connects to all other site facilities, recreational facilities, accessible building entrances and accessible parking spaces. Yo do not need to provide a site plan for the entire site if you can add the requested notes and do the research to determine this recreational facility complies. 3. REPEAT COMMENT. NO RESPONSE PROVIDED BY THE ARCHITECT. PLEASE RESPOND TO COMMENT: On this site plan you will need to show cross and running slopes for new sidewalks serving this new facility per Section 403.3. 4. REPEAT COMMENT. NO RESPONSE PROVIDED BY THE ARCHITECT. PLEASE RESPOND TO COMMENT: Gates must be provided with maneuverability clearances per Section 404.2.4.1 and Table 404.2.4.1 based on forward approach. From the exterior side of the pickle ball courts, this means the sidewalk landing in front of gates (pull side) must extend 18 inches beyond the latch side of the gate. 5. REPEAT COMMENT. NO RESPONSE PROVIDED BY THE ARCHITECT. PLEASE RESPOND TO COMMENT: Gate latches must comply with Section 309.3. Please provide gate latch / hardware mounting height consistent with this Section 308.2 and Figure 308.2.1 for forward reach. Gate hardware to comply with Section 309.4. | |||
| ELEC | HOLD | 06/09/2021 | 06/09/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM List elctrical sub contractor and need to show where power is coming from for new pole light and include wire and breaker size. | |||
| ARCHR | COMPLETE | 06/01/2021 | 06/13/2021 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/01/2021 | 06/14/2021 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Accessibility 1. This recreational facility is subject to regulation under the 2020 Florida Building Code-Accessibility. Please add this code as a referenced standard. 2. Is there a plan sheet C1.0? If so provide it. 3. Is there a plan sheet C5.0? Plan sheet C3.0 mentions a sidewalk detail on Plan Sheet C5.00. Please provide this plan sheet if it exists. 4. This recreation facility must be connected to remainder of site by accessible route complying with Section 206, 402, 403. . Povide notes indicating this facility is on a connected accessible exterior route that connects to all other site facilities, recreational facilities, accessible building entrances and accessible parking spaces. Yo do not need to provide a site plan for the entire site if you can add the requested notes and do the research to determine this recreational facility complies. 5. On this site plan you will need to show cross and running slopes for new sidewalks serving this new facility per Section 403.3. 6. Gates must be provided with maneuverability clearances per Section 404.2.4.1 and Table 404.2.4.1 based on forward approach. From the exterior side of the pickle ball courts, this means the sidewalk landing in front of gates (pull side) must extend 18 inches beyond the latch side of the gate. 7. Gate latches must comply with Section 309.3. Please provide gate latch / hardware mounting height consistent with this Section 308.2 and Figure 308.2.1 for forward reach. Gate hardware to comply with Section 309.4. | |||
| DSD | COMPLETE | 06/01/2021 | 06/13/2021 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| FI1 | COMPLETE | 06/01/2021 | 06/09/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| UD1 | COMPLETE | 06/01/2021 | 06/02/2021 |
| Note: Released By: CHRIS JOHNSON - - CJOHNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN COMMERCIAL | ¤60.00 | 07/30/2021 |
| INSPECTION - COMMERCIAL ACCESS | ¤553.43 | 07/30/2021 |
| BUILDING DISCOUNT 100% | (¤820.87) | 07/30/2021 |
| ELECTRIC FEE | ¤107.44 | 07/30/2021 |
| PLAN CHECK FEE | ¤100.00 | 07/30/2021 |
| SITE PLAN 20 | ¤20.00 | 07/30/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 07/30/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 07/30/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤24.00 |