I want to search for...
Permit #2021060101
Permit Details
Status: COED
| Parcel Id: 07-11-31-7030-00310-0190 |
| CONDITIONED SPACE: 1691 sqft |
| GARAGE: 450 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| OPENED PORCH (WITH ROOF) : 22 sqft |
| Total Square Footage: 2275 sqft |
| Block: 00310 |
| Subdivision: 2154 - SECTION 30-ROYAL PALMS |
| Job Phone: 863-845-6967 |
| Location Address: 31 RADFORD LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/16/2022 |
| NOC: RECORDED |
| Applicant name: LARRY SHERWIN THOMPSON |
| Owner: CARPENTER COMPANIES FLORIDA |
|
Address 142 WEST PLATT STREET STE 116 TAMPA, FL 33606 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
THOMCO OF FLORIDA LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
6381 ROBERTS RD KATHLEEN, FL 33849 |
CGC1513647 (Exp: 08/31/2024) | 863-845-6967 |
Sub Contractors
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
ROBERT MICHAEL RENNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
531 CODISCO WAY SANFORD, FL 32771 |
CAC051477 (Exp: 08/31/2026) | 407-333-2665 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/28/2023 | FINAL APPROVED | JWALKER |
| Note: 7/20/2023 - PREVIOUS INSPECTION NOTES Project incomplete. Contruction debris throughout AAV is installed Check for AAV at kitchen sink at final inspection. | |||
| BLD - BUILDING FINAL | 07/20/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Project incomplete. Contruction debris throughout AAV is installed Check for AAV at kitchen sink at final inspection. | |||
| ROW - STORMWATER FINAL | 07/18/2023 | APPROVED | FSLADISH |
| Note: 07/18/23 CORRECTION BEING MADE. OTHERWISE EVERYTHING LOOKED GOOD AT THE TIME OF THIS INSPECTION. _____________________________________________________________________________________________________________________________ 07/17/23 WILL NEED TO CLEAN UP OLD HOT TUB, TRASH AND CONTRUCTION DEBRIS ON VACANT LOTS. | |||
| U -UTILITY RESIDENTIAL FINAL | 07/18/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: pep circuit breaker WAS NOT labled-inspector labled it in future lable or will result in failed inspection | |||
| ROW - FINAL APRON (AFTER POUR) | 07/17/2023 | APPROVED | FSLADISH |
| Note: 07/17/23 PIPE IS GOOD. CUTS MADE. CULVERT CLEAR. LOOKED GOOD AT THE TIME OF THIS INSPECTION. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/17/2023 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/17/2023 | APPROVED | FSLADISH |
| Note: 07/17/23 APPEARS DRAINAGE WILL WORK AS INDICATED IN FINAL SURVEY. LOOKED GOOD AT THE TIME OF THIS INSPECTION. | |||
| U-CROSS CONNECTION | 07/13/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: has potable irrigation with PVB installed-no cross connection | |||
| ROW- PROJECT STATUS | 04/28/2023 | APPROVED | GBERTOLA |
| Note: meeting with the builder, NEED TO RAISE THE BACK YARD AND MOVE THE WATER TO THE FRONT. ON THE SIDE NEED TO HAVE A COMMON SWALE | |||
| ELECTRIC - EARLY POWER | 04/26/2023 | APPROVED | JWALKER |
| GRAVITY SEWER TEST | 04/20/2023 | APPROVED | MGIBSON |
| U - SEWER TIE IN | 04/20/2023 | APPROVED | MGIBSON |
| ROW- PRE-APRON (PRE-POUR) | 04/13/2023 | APPROVED | FSLADISH |
| Note: 04/13/23 READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| PEP TANK INSTALLATION REQUEST | 03/29/2023 | APPROVED | TSCHWEERS |
| INSULATION | 01/20/2023 | APPROVED | JWALKER |
| LATH/BRICK/ WATER BARRIER | 01/17/2023 | APPROVED | JWALKER |
| ALL ROUGH | 01/12/2023 | APPROVED | JWALKER |
| Note: 1/6/2023 - PREVIOUS INSPECTION NOTES 1. 200 amp service breaker installed. Service wire install is 2/0 awg aluminum, 4/0 must be used. 2. Copper ground wire to UFER needs to be protected in IMC, PVC, XW, EMT, OF Cable armor. Remove flexible NM conduit. NEC 250.64 B (2) 3. 5' head test is not holding water. 4. Bathroom exhaust fans are not wired. Check for AAV at kitchen sink at final inspection. | |||
| ALL ROUGH | 01/06/2023 | Disapproved - NO FEE | JWALKER |
| Note: 1. 200 amp service breaker installed. Service wire install is 2/0 awg aluminum, 4/0 must be used. 2. Copper ground wire to UFER needs to be protected in IMC, PVC, XW, EMT, OF Cable armor. Remove flexible NM conduit. NEC 250.64 B (2) 3. 5' head test is not holding water. 4. Bathroom exhaust fans are not wired. Check for AAV at kitchen sink at final inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/08/2022 | APPROVED - AS NOTED | JWALKER |
| Note: 1.Gable truss T38 Blocking and bracing not installed as per detail GE21 on pg 6. 2. Minimum permanent bracing Truss X braces (4) not installed detail TBO5, Pg 6. 3. Simpson HGMA10 anchor and bracing not installed at rear porch CMU wall. Detail TB14, Pg S-2 12/8/22 Please have items listed aboved corrected for ALL ROUGH inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/04/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 1.Gable truss T38 Blocking and bracing not installed as per detail GE21 on pg 6. 2. Minimum permanent bracing Truss X braces (4) not installed detail TBO5, Pg 6. 3. Simpson HGMA10 anchor and bracing not installed at rear porch CMU wall. Detail TB14, Pg S-2 4. Gable end truss over garage opening Missing Cross bracing, 2x4 between bottom chords, HGA10 anchors, 2x8 at top of cmu not completed. See and follow Detail GEO1, Pg S-2. 5. Two ply trusses TO1 and T 39 Not fastened together as per the Mitek truss engineering specs. 6. Trusses T29, T30, T31, and T38 Missing engineering. Roof sheating previously checked, Down Cells Passed. Check all strapping at reinspection. | |||
| ROOF VALLEY & METAL | 10/20/2022 | APPROVED | JWALKER |
| ROOF SHEATHING | 10/14/2022 | APPROVED | JWALKER |
| WALL SHEATHING | 10/14/2022 | APPROVED | JWALKER |
| TIE BEAM / LINTEL | 09/26/2022 | APPROVED | JWALKER |
| FOUND SURVEY APPROVED (OFFICE) | 07/25/2022 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 06/28/2022 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION Soil has eroded into the footings covering rebar. footings will need to be dug out. Plastic will need resealed. | |||
| MONOLITHIC SLAB | 06/27/2022 | Disapproved - NO FEE | JWALKER |
| Note: Soil has eroded into the footings covering rebar. footings will need to be dug out. Plastic will need resealed. | |||
| MONOLITHIC SLAB | 06/01/2022 | Disapproved - NO FEE | JWALKER |
| Note: The garage and front area of the building footings are not 12" below undisturbed soil. The entire slab needs to be tamped. UFER not installed. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/25/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 04/08/2022 | APPROVED | CSTONE |
| WATER METER INSTALLATION REQUEST | 02/22/2022 | CANCELLED BY APPLICANT | WEB |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/31/2022 | 10/31/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/25/2022 | 07/25/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/25/2022 | 07/25/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/10/2022 | 02/10/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/10/2022 | 02/10/2022 |
| Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/10/2022 | 02/10/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 02/03/2022 | 02/09/2022 |
| Note: Held By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM nothing has changed on site plan R.O.W lane need to be equal or greater than centerline road | |||
| ENGIN1 | HOLD | 02/03/2022 | 02/03/2022 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Site plan submitted on 2-3-22 has incorrect benchmark elevation - please coinfirm and resubmit. | |||
| ZON | COMPLETE | 01/03/2022 | 01/03/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 01/03/2022 | 01/11/2022 |
| Note: Held By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM front property line is to be greater than or equl to the center of the road | |||
| ZON | HOLD | 11/17/2021 | 11/17/2021 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: Section number in the description on site plan/survey is incorrect. Should be Section 30 | |||
| SW1 | HOLD | 11/17/2021 | 11/19/2021 |
| Note: Held By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM Need to submit a new Site plan | |||
| ENGIN1 | COMPLETE | 11/17/2021 | 11/17/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 09/22/2021 | 09/22/2021 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: Section number on site plan/survey is incorrect | |||
| SW1 | HOLD | 09/22/2021 | 09/29/2021 |
| Note: Held By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM Holding for the same reason. When building next to a vacant lot. Drainage needs to run down the property line, not inside the property line. The revised site plan show the drainage running between the house and the property line, not ON the property line. | |||
| ENGIN1 | COMPLETE | 09/22/2021 | 09/23/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/12/2021 | 08/12/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/12/2021 | 08/12/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/12/2021 | 08/16/2021 |
| Note: Released By: JPI | |||
| SW1 | HOLD | 08/12/2021 | 08/19/2021 |
| Note: Held By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM When there is a vacant on the side of the house there must be a "Common Swale". Survey shows a drainage pattern inside the property line. | |||
| ZON | HOLD | 08/12/2021 | 08/12/2021 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: Site plan must show the width and material of front entry walkway and driveway House layout on landscape plan doesn't match plans and site plan Must have a total of four trees for this lot size Residential homes shall provide foundation plantings consisting of sixteen (16) shrubs. On interior lots, eight (8) shrubs shall be planted in front of the home, and four (4) shrubs planted on each side of the home. AC pad must be screened with 7 gallon shrubs Section number on site plan/survey is incorrect | |||
| SW1 | HOLD | 06/08/2021 | 06/08/2021 |
| Note: Held By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM Refer to stormwater checklist to make the corrections needed to meet the city minimums stormwater requirements | |||
| SWALE | COMPLETE | 06/02/2021 | 11/03/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 06/02/2021 | 06/02/2021 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Centerline of road elevations differ from ITT as-builts by 3.5' | |||
| ZON | HOLD | 06/01/2021 | 06/10/2021 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Site plan must show the width and material of front entry walkway and driveway House layout on landscape plan doesn't match plans and site plan Must have a total of four trees for this lot size Residential homes shall provide foundation plantings consisting of sixteen (16) shrubs. On interior lots, eight (8) shrubs shall be planted in front of the home, and four (4) shrubs planted on each side of the home. Please state on color sheet that stucco and siding will all be one color. Section number on site plan/survey is incorrect | |||
| BLD | HOLD | 06/01/2021 | 06/07/2021 |
| Note: Held By: JPI 1. Product Approval Spec Sheet provided, and Product Approval #’s provided on drawings, page PA. Numbers do not match for multiple products. Please review and provide matching numbers or eliminate one. 2. Provide dutch/boston gable end framing details. | |||
| CUSVC | COMPLETE | 06/01/2021 | 06/08/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 06/01/2021 | 06/02/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/01/2021 | 06/02/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 06/01/2021 | 06/09/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/01/2021 | 06/02/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Orientation of Energy Calcs does not match the site plan. Revise to match the site plan. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 08/24/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 08/24/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 08/24/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/24/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 08/24/2023 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/16/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 02/16/2022 |
| SEWER INSPECTION | ¤25.00 | 02/16/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 02/16/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 02/16/2022 |
| CONNECTION FEES | ¤1,077.88 | 02/16/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 02/16/2022 |
| BUILDING DISCOUNT 100% | (¤1,090.40) | 02/16/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 02/16/2022 |
| IMPACT FEE FIRE | ¤367.00 | 02/16/2022 |
| IMPACT FEE PARKS | ¤1,199.12 | 02/16/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 02/16/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 02/16/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 02/16/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 02/16/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 02/16/2022 |
| NEW RESIDENTIAL INSPECTIONS | ¤424.00 | 02/16/2022 |
| SITE PLAN 20 | ¤20.00 | 02/16/2022 |
| SURCHARGE FS 533.721 | ¤2.00 | 02/16/2022 |
| SURCHARGE - FS 468.631 | ¤2.00 | 02/16/2022 |
| METER - DEPOSIT | ¤60.00 | 02/16/2022 |
| METER - DEPOSIT | ¤60.00 | 02/16/2022 |
| WATER-METER | ¤467.09 | 02/16/2022 |
| WATER- TURN ON | ¤25.00 | 02/16/2022 |
| WATER- TURN ON | ¤25.00 | 02/16/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤20.00 | 02/16/2022 |
| EXTENSION | ¤40.00 | 02/16/2022 |
| INSPECTION- ELECTRICAL | ¤187.20 | 02/16/2022 |
| INSPECTION - MECHANICAL | ¤187.20 | 02/16/2022 |
| INSPECTION - PLUMBING | ¤187.20 | 02/16/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤84.80 | 02/16/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤17,458.33 |