I want to search for...

Permit #2021060271

Permit Details

Status: FINAL

Parcel Id: 29-10-31-5540-00000-1630
Block: 00000
Subdivision: 1005 - SANCTUARY SUBDIVISION
Job Phone: (321)251-8359
Location Address: 13 OLD OAK DR S
Type: RF - REROOF
Issue Date: 06/15/2021
NOC: RECORDED
Applicant name: ELMER ANTONIO CAMPOS
Owner: HECK SCOTT A & EILEEN GUARIN HECK H&W LIFE ESTATE

Address

13 OLD OAK DRIVE SOUTH

PALM COAST, FL 32137

Lot: 1630
Contracted Stated Job Value: ¤20,783.00
Job Description: ROOF WITH ASPHALT SHINGLES ---- FL5444
Type: CN

Contractor

PRO ROOFING & ASSOCIATE INC.
Status Location Address State License Number Phone Fax
ACTIVE

2895 S. ORLANDO DR

SANFORD, FL 32773

CCC1328416 (Exp: 08/31/2026) 407-542-5903 (321)251-8639

Inspection History

Type Request Date Result Inspector
ROOF FINAL 07/30/2021 FINAL APPROVED WMILLER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION A Drone Inspection is required. A drone inspection will be set up in the near future. 7-27-21... same notes as above 7-30-21... drone inspection complete
ROOF FINAL 07/27/2021 Disapproved - NO FEE WMILLER
Note: THIS IS A REINSPECTION A Drone Inspection is required. A drone inspection will be set up in the near future. 7-27-21... same notes as above
ROOF FINAL 07/26/2021 CANCELLED BY APPLICANT WMILLER
Note: A Drone Inspection is required. A drone inspection will be set up in the near future.
ROOF AFFIDAVIT 07/22/2021 APPROVED MDEFREITAS
ROOF IN PROGRESS- MIDROOF 07/21/2021 APPROVED WMILLER
Note: THIS IS A REINSPECTION Midroof not ready: • At least 50% shingles need to be removed, • At least 50% of drip edge needs to be applied, • at least 90 percent of underlayment needs to be installed, • need up to 25 percent of shingles installed, • need worksheet and, ASTM docs and Manufacturer docs along with permit on site for inspection 7-21-21... notes above resolved
ROOF IN PROGRESS- MIDROOF 07/20/2021 Disapproved -FEE REQUIRED WMILLER
Note: Midroof not ready: • At least 50% shingles need to be removed, • At least 50% of drip edge needs to be applied, • at least 90 percent of underlayment needs to be installed, • need up to 25 percent of shingles installed, • need worksheet and, ASTM docs and Manufacturer docs along with permit on site for inspection

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 07/20/2021
SURCHARGE FS 533.721 ¤2.00 06/15/2021
SURCHARGE - FS 468.631 ¤2.00 06/15/2021
ADMIN FEE ¤20.00 06/15/2021
BUILDING DISCOUNT 100% (¤60.00) 06/15/2021
INSPECTION 40 ¤40.00 06/15/2021
Fees Total Due: ¤0.00 Total Paid: ¤44.00