I want to search for...
Permit #2021061005
Permit Details
Status: COED
| Parcel Id: 07-11-31-7059-00120-0060 |
| CONDITIONED SPACE: 1669 sqft |
| GARAGE: 454 sqft |
| OPENED PORCH (WITH ROOF) : 225 sqft |
| OPENED PORCH (WITH ROOF) : 125 sqft |
| OPENED PORCH (WITH ROOF) : 40 sqft |
| Total Square Footage: 2513 sqft |
| Block: 00120 |
| Subdivision: 2211 - SECTION 59-SEMINOLE PARK |
| Job Phone: 386-313-6950 |
| Location Address: 27 SEA SPIRAL PATH |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/30/2021 |
| NOC: RECORDED |
| Applicant name: MARK ANTHONY LANGELLO |
| Owner: SHEEKEY LINDSAY JASON GREGORY WILLIAMS JTWROS |
|
Address 26 SEA SPIRAL PATH PALM COAST, FL 32164 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤143,306.23 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
M & M DEVELOPMENT & CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
2323 N. STATE ST BUNNELL, FL 32110 |
RG291103911 (Exp: 08/31/2023) | 386-313-6950 |
Sub Contractors
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
WERNER SCHUMACHER
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 350791 PALM COAST, FL 32135 |
EC13007106 (Exp: 08/31/2026) | 386-852-8541 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - STORMWATER FINAL | 05/24/2022 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION swale need to be rapeir ON THE LEFT SIDE, ALL MATERIAL ON THE EMPTY LOT NEED TO BE ROMOVED INCLUDE THE PELLETS SWALE DAMAGE NEED TO BE COMPLETELY REPAIR AND RE-SOD. ALL RUTTS AND BARE SPOTS MUST BE FILLED AND SODDED, NOT SEEDED OR COVERED W/STRAW AND/OR PINE NEEDLE | |||
| U -UTILITY RESIDENTIAL FINAL | 05/23/2022 | FINAL APPROVED | JHARDING |
| ROW - STORMWATER FINAL | 05/23/2022 | Disapproved - NO FEE | GBERTOLA |
| Note: swale need to be rapeir ON THE LEFT SIDE, ALL MATERIAL ON THE EMPTY LOT NEED TO BE ROMOVED INCLUDE THE PELLETS SWALE DAMAGE NEED TO BE COMPLETELY REPAIR AND RE-SOD. ALL RUTTS AND BARE SPOTS MUST BE FILLED AND SODDED, NOT SEEDED OR COVERED W/STRAW AND/OR PINE NEEDLE | |||
| BLD - BUILDING FINAL | 05/23/2022 | FINAL APPROVED | RMARTIN |
| ROW - FINAL APRON (AFTER POUR) | 05/19/2022 | APPROVED | PFLANAGAN |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/19/2022 | APPROVED | PFLANAGAN |
| FINAL SURVEY (OFFICE USE ONLY) | 05/19/2022 | APPROVED | PFLANAGAN |
| U-CROSS CONNECTION | 05/13/2022 | APPROVED - AS NOTED | JHARDING |
| Note: No irrigation, no cross connections. | |||
| U - SEWER TIE IN | 05/05/2022 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 05/05/2022 | APPROVED | MGIBSON |
| ROW- PRE-APRON (PRE-POUR) | 04/28/2022 | APPROVED - AS NOTED | PFLANAGAN |
| Note: 4/28/22 ITS IS THE CONTRACTORS RESPONSIBILITY TO CHECK CULVERT PIPE ELEVATIONS BEFORE POURING CONCRETE 04/22/22= CULVERT PIPE IS OUT OF TOLERANCE BOTH END. PLEASE RESET THE PIPE ACCORDING SWALE PLAN – CULVERT PIPE IS PITCHED IN WRONG WAY NEED TO LOWER LEFT SIDE OF PIPE BY .20 | |||
| ROW- PRE-APRON (PRE-POUR) | 04/22/2022 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 04/22/22= CULVERT PIPE IS OUT OF TOLERANCE BOTH END. PLEASE RESET THE PIPE ACCORDING SWALE PLAN – CULVERT PIPE IS PITCHED IN WRONG WAY NEED TO LOWER LEFT SIDE OF PIPE BY .20 | |||
| ROW- PRE-APRON (PRE-POUR) | 04/18/2022 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: CULVERT PIPE IS PITCHED IN WRONG WAY NEED TO LOWER LEFT SIDE OF PIPE BY .20 | |||
| PEP TANK INSTALLATION REQUEST | 04/14/2022 | APPROVED | CSTONE |
| ELECTRIC - EARLY POWER | 04/04/2022 | PARTIALLY APPROVED | TSTAUFFACHER |
| Note: emailed FPL released power at 12:04 PM | |||
| LATH/BRICK/ WATER BARRIER | 03/10/2022 | APPROVED | TSTAUFFACHER |
| ROOF VALLEY & METAL | 02/24/2022 | APPROVED | TSTAUFFACHER |
| INSULATION | 02/18/2022 | APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Recess cans not allowed in garage FBC 302.5 | |||
| INSULATION | 02/16/2022 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Recess cans not allowed in garage FBC 302.5 | |||
| ALL ROUGH | 02/08/2022 | APPROVED | TSTAUFFACHER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/25/2022 | APPROVED | TSTAUFFACHER |
| FOUND SURVEY APPROVED (OFFICE) | 01/24/2022 | APPROVED | TBAKER |
| ELECTRIC TEMP POLE | 12/17/2021 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POLE 12/17/21 | |||
| ELECTRIC TEMP POLE | 12/15/2021 | Disapproved - NO FEE | JMUNSON |
| Note: 1. Outlets need to be weather resistant 2. Unused opening in panel needs to be sealed. NEC 2017 110.12 | |||
| TIE BEAM / LINTEL | 10/25/2021 | APPROVED | TSTAUFFACHER |
| MONOLITHIC SLAB | 09/10/2021 | APPROVED | TSTAUFFACHER |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/07/2021 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION NO PRESSURE ON WATER LINES | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 09/03/2021 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: NO PRESSURE ON WATER LINES | |||
| WATER METER INSTALLATION REQUEST | 08/20/2021 | APPROVED | TCHURCHILL |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 01/24/2022 | 01/24/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/24/2022 | 01/24/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/07/2021 | 07/08/2021 |
| Note: Released By: ESTELLE LENS - (386)986-3751 - | |||
| BLD | COMPLETE | 07/07/2021 | 07/07/2021 |
| Note: Released By: JPI | |||
| SWALE | COMPLETE | 07/07/2021 | 09/01/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/07/2021 | 07/07/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/07/2021 | 07/07/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/07/2021 | 07/13/2021 |
| Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/24/2021 | 06/24/2021 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM PLAN REVIEW COMMENT NO. 3 FROM PREVIOUS BUILDING REVIEW HOLD HAS BEEN REMOVED. THE CITY HAS NOT HISTORICALLY REQAUIRED EGRESS WINDOWS TO BE IDENTIFIED ON FLOOR PLANS. PLEASE RESPOND TO REMAINING ITEMS BELOW. 1. Product Approval Specification Sheet: a. Exterior Wall Soffits product approval number is invalid (17636); provide approved product, product description, manufacturer, and product approval number. b. Non-Structural Metal Roofing Product approval number does NOT match the Roofing Worksheet/Form. c. Provide ALL wood connectors, wood anchors, and truss plates product approval numbers that are utilized on the project. 2. It appears that the Metal Roof Panels product approval number on the City of Palm Coast Roofing Worksheet/Form is invalid and does NOT match Product Approval Specification Sheet. | |||
| BADMIN | HOLD | 06/24/2021 | 06/24/2021 |
| Note: Held By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM YOU NEED TO SUBMIT ALL THE OTHER HOLDS NOT JUST THE BUILDING . | |||
| BADMIN | COMPLETE | 06/24/2021 | 06/24/2021 |
| Note: Released By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/23/2021 | 06/23/2021 |
| Note: Held By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM Refer to stormwater checklist to make the corrections needed to meet the city minimums stormwater requirements | |||
| ZON | HOLD | 06/23/2021 | 06/23/2021 |
| Note: Held By: ESTELLE LENS - (386)986-3751 - Held By: ESTELLE LENS - (386)986-3751 - Please submit a signed and sealed survey. Survey and site plan need to have the legal description of the property including the map book and page. Survey and site plan need to have the flood zone and FEMA map panel number. Site plan needs to specify the driveway and walkway widths. Please specify the type of under story tree being proposed on the landscape plan to ensure it is a credit tree. Need to provide the size of the foundation plantings being proposed. The A/C screening needs to be 7 gallon shrubs. The foundation plantings need to be min. 3 gallon shrubs. | |||
| BLD | HOLD | 06/16/2021 | 06/22/2021 |
| Note: Held By: JPI 1. Product Approval Specification Sheet: a. Exterior Wall Soffits product approval number is invalid (17636); provide approved product, product description, manufacturer, and product approval number. b. Non-Structural Metal Roofing Product approval number does NOT match the Roofing Worksheet/Form. c. Provide ALL wood connectors, wood anchors, and truss plates product approval numbers that are utilized on the project. d. Siding Trim (elevations) omitted; provide product description& type, manufacturer, and product approval number. e. Awnings (elevations) omitted; provide product description& type, manufacturer, and product approval number. 2. It appears that the Metal Roof Panels product approval number on the City of Palm Coast Roofing Worksheet/Form is invalid and does NOT match Product Approval Specification Sheet. 3 Indicate “EGRESS” windows/doors on the Floor Plan, Sht. 3 for ALL Bedrooms- FBC 107.3.5. | |||
| CUSVC | COMPLETE | 06/16/2021 | 06/21/2021 |
| Note: Released By: ALYSSA ROSCOE - - | |||
| ELEC | HOLD | 06/16/2021 | 06/17/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Electric load calcs do not match the square footage of the house. NEC 2017 220 | |||
| ENGIN1 | HOLD | 06/16/2021 | 06/16/2021 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM No benchmark on survey. | |||
| LOCATE | COMPLETE | 06/16/2021 | 06/24/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/16/2021 | 06/17/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 05/24/2022 |
| SW ENG REINSPECTION 30 | ¤30.00 | 05/24/2022 |
| SW ENG REINSPECTION 30 | ¤30.00 | 05/24/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/24/2022 |
| CONNECTION FEES | ¤1,017.83 | 07/30/2021 |
| METER - DEPOSIT | ¤60.00 | 07/30/2021 |
| WATER- TURN ON | ¤25.00 | 07/30/2021 |
| ADMIN FEE | ¤20.00 | 07/30/2021 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/30/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 07/30/2021 |
| SEWER CREDIT | (¤1,147.00) | 07/30/2021 |
| SEWER INSPECTION | ¤25.00 | 07/30/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 07/30/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 07/30/2021 |
| BUILDING DISCOUNT 100% | (¤1,124.00) | 07/30/2021 |
| ELECTRIC FEE | ¤192.00 | 07/30/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 07/30/2021 |
| IMPACT FEE FIRE | ¤367.00 | 07/30/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 07/30/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 07/30/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 07/30/2021 |
| MECHANICAL FEE | ¤192.00 | 07/30/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/30/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 07/30/2021 |
| PLAN CHECK FEE | ¤88.00 | 07/30/2021 |
| PLUMBING FEE | ¤192.00 | 07/30/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤440.00 | 07/30/2021 |
| SITE PLAN 20 | ¤20.00 | 07/30/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 07/30/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 07/30/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,124.43 |