I want to search for...
Permit #2021061033
Permit Details
Status: COED
| Parcel Id: 07-11-31-7010-00190-0030 |
| CONDITIONED SPACE: 2860 sqft |
| GARAGE: 625 sqft |
| OPENED PORCH (WITH ROOF) : 212 sqft |
| OPENED PORCH (WITH ROOF) : 100 sqft |
| Total Square Footage: 3797 sqft |
| Block: 00190 |
| Subdivision: 2137 - SECTION 10-FLORIDA PARK |
| Job Phone: 386-960-7720 |
| Location Address: 6 FLAT ROCK LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/13/2021 |
| NOC: RECORDED |
| Applicant name: LAWRENCE FRED SIETSMA |
| Owner: AVTEC HOMES INC |
|
Address 620 MALABAR RD SE STE 5 PALM BAY, FL 32907 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤341,775.00 |
| Job Description: single family residence |
| Type: CN |
Contractor
AVTEC HOMES INC
| Status | Location Address | State License Number | Phone |
| CANCEL |
2405 E GRAVES AVE ORANGE CITY, FL 32763 |
CRC041905 (Exp: 08/31/2024) | 386-960-7720 |
Sub Contractors
DOUGLAS EDWARD RICHARDS
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
108 E INDIANA AVENUE DELAND, FL 32724 |
CCC1328824 (Exp: 08/31/2024) | 386-736-4226 | 386-740-0535 |
STEVEN JAY SMITH
| Status | Location Address | State License Number | Phone |
| INACTIVE |
104 West Cedar Avenue Orange City, FL 32763 |
EC0001542 (Exp: 08/31/2022) | (386)775-7776 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
BRUCE R BOLTON
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
1982 SR 44 NEW SMYRNA BEACH, FL 32168 |
SUITE 357 NEW SMYRNA BEACH, FL 32168 |
CAC1817407 (Exp: 08/31/2022) | 386-216-5975 | 386-402-4191 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 02/16/2022 | FINAL APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION 1. Master bath toilet closet does not work. 2. AHU high voltage wire not seasled. 3. Energy calculations do not match. 2-16-22 notes above resolved | |||
| BLD - BUILDING FINAL | 02/15/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 1. Master bath toilet closet does not work. 2. AHU high voltage wire not seasled. 3. Energy calculations do not match. | |||
| ROW - FINAL APRON (AFTER POUR) | 02/15/2022 | APPROVED | KRUTH |
| ROW - STORMWATER FINAL | 02/15/2022 | APPROVED | KRUTH |
| ROW - STORMWATER FINAL | 02/14/2022 | CANCELLED BY APPLICANT | WEB |
| ROW - FINAL APRON (AFTER POUR) | 02/14/2022 | CANCELLED BY APPLICANT | WEB |
| BLD - BUILDING FINAL | 02/14/2022 | CANCELLED BY APPLICANT | WEB |
| ROW - FINAL APRON (AFTER POUR) | 02/10/2022 | CANCELLED BY APPLICANT | WEB |
| ROW - STORMWATER FINAL | 02/10/2022 | CANCELLED BY APPLICANT | WEB |
| U -UTILITY RESIDENTIAL FINAL | 02/10/2022 | FINAL APPROVED | DHANEY |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/07/2022 | APPROVED | KRUTH |
| FINAL SURVEY (OFFICE USE ONLY) | 02/07/2022 | APPROVED | KRUTH |
| ELECTRIC - EARLY POWER | 01/20/2022 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 1:10 PM | |||
| GRAVITY SEWER TEST | 01/10/2022 | APPROVED | MGIBSON |
| U - SEWER TIE IN | 01/10/2022 | APPROVED | MGIBSON |
| U-CROSS CONNECTION | 01/10/2022 | APPROVED - AS NOTED | DHANEY |
| Note: Approved Yard/ IRR. not installed yet. no cross CN. | |||
| ROW- PRE-APRON (PRE-POUR) | 12/02/2021 | APPROVED | KRUTH |
| Note: pipe is good at the time of the inspection It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete | |||
| LATH/BRICK/ WATER BARRIER | 10/27/2021 | APPROVED | DCUSHING |
| INSULATION | 10/22/2021 | APPROVED | RMARTIN |
| ALL ROUGH | 10/21/2021 | APPROVED | DCUSHING |
| Note: THIS IS A REINSPECTION Electrical wiring in kitchen (refridge. area) coming out of floor outside of framed wall, conduit cut flush with floor, nail guard pinching wire, wall or wiring needs to be moved 10-20-21 ISSUE RESOLVED | |||
| ALL ROUGH | 10/19/2021 | Disapproved -FEE REQUIRED | DCUSHING |
| Note: Electrical wiring in kitchen (refridge. area) coming out of floor outside of framed wall, conduit cut flush with floor, nail guard pinching wire, wall or wiring needs to be moved | |||
| ROOF VALLEY & METAL | 10/04/2021 | APPROVED | DCUSHING |
| WALL SHEATHING | 09/27/2021 | APPROVED | LMILLER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/27/2021 | APPROVED | LMILLER |
| TIE BEAM / LINTEL | 09/03/2021 | APPROVED | RMARTIN |
| FOUND SURVEY APPROVED (OFFICE) | 09/02/2021 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 08/06/2021 | APPROVED | PBUCKLEY |
| PLUMBING 1ST ROUGH UNDERGROUND | 07/29/2021 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 07/19/2021 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 02/16/2022 | 02/16/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/15/2022 | 02/15/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| MECH | HOLD | 02/15/2022 | 02/15/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder | |||
| ENGIN1 | COMPLETE | 09/02/2021 | 09/02/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/02/2021 | 09/02/2021 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/14/2021 | 07/14/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/06/2021 | 07/07/2021 |
| Note: Released By: ESTELLE LENS - (386)986-3751 - | |||
| BLD | COMPLETE | 06/24/2021 | 06/29/2021 |
| Note: Released By: JPI | |||
| ZON | HOLD | 06/24/2021 | 06/25/2021 |
| Note: Held By: ESTELLE LENS - (386)986-3751 - Repeat comments: Horizontal banding must wrap the corners. Banding is required on the windows and doors in the rear facing the public right of way. | |||
| ELEC | COMPLETE | 06/24/2021 | 06/28/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/24/2021 | 06/25/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/23/2021 | 06/23/2021 |
| Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/22/2021 | 06/22/2021 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM PLEASE NOTE, THE ADVISORY NOTE REQUESTING LOCATION AND SIZE OF ATTIC ACCESS HAS BEEN REMOVED FROM THE PREVIOUS BUILDING REVIEW HOLD BECAUSE ADVISORY NOTES ARE NOT MANDATORY. ADDITIONALLY, THE ATTIC ACCESS IS CLEARLY SHOWN ON PLAN SHEET A1. PLEASE ALSO NOTE, THE PREVIOUS REVIEW COMMENT NO. 1. a. REQUSTING OPENING PROTECTIVE PRODUCT APPROVAL NUMBER HAS ALSO BEEN REMOVED. THE HOME IS NOT LOCATED IN THE WINDBORNE DEBRIS REGION AND THEREFORE PROTECTED OPENINGS ARE NOT REQUIRED FOR THIS HOME. PLEASE ALSO NOTE, THE PREVIOUS REVIEW COMMENTS NO. 2 AND NO. 3 HAVE ALSO BEEN REMOVED AS THE DIMENSION FOR FILLED-SELLS IS SHOWN IN THE GENERAL CONSTRUCTION NOTE BOX ON PLAN SHEET A1 AND BECAUSE SAFE LOAD LIMITS FOR LINTELS IS NOT REQURIED IN SECTION R608.1. PLEASE RESPOND TO THE REMAINING REVIEW COMMENTS BELOW. 1. Product Approval Specification Sheet: b. 8’-0 Sectional/Roll Up door omitted from Product Approval Specification Sheet; provide approved product, product description, manufacturer, and product approval number. c. Identify appropriate product approval numbers for each sectional/rollup door. | |||
| ZON | HOLD | 06/16/2021 | 06/23/2021 |
| Note: Held By: ESTELLE LENS - (386)986-3751 - Four foundation plantings are required in the rear facing the public right of way. Horizontal banding must wrap the corners. Banding is required on the windows and doors in the rear facing the public right of way. | |||
| BLD | HOLD | 06/16/2021 | 06/20/2021 |
| Note: Held By: JPI 1. Product Approval Specification Sheet: a. Swinging Exterior Doors (Therm Tru) are described/specified as “non-impact”. Provide the product approval for the opening protection methods. b. 8’-0” Sectional/Roll Up door omitted from Product Approval Specification Sheet; provide approved product, product description, manufacturer, and product approval number. c. Identify appropriate product approval numbers for each sectional/rollup door. 2. Provide filled-cell vertical reinforcement dimensioned locations on Foundation Plan, Sht. A1. FBC-R2108.1. 3. Provide lintel schedule with safe load limits and submittals. FBC-R608.1. Advisory Note a. Clearly label the location and size of the attic access. | |||
| CUSVC | COMPLETE | 06/16/2021 | 06/21/2021 |
| Note: Released By: ALYSSA ROSCOE - - | |||
| ELEC | HOLD | 06/16/2021 | 06/17/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit electric load calcs. | |||
| ENGIN1 | COMPLETE | 06/16/2021 | 06/16/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 06/16/2021 | 06/21/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/16/2021 | 06/17/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Orientation of Energy calcs does not match the site plan. Revise to match. | |||
| SWALE | COMPLETE | 06/16/2021 | 09/01/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 02/22/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/22/2022 |
| CONNECTION FEES | ¤1,017.83 | 07/13/2021 |
| BUILDING DISCOUNT 100% | (¤1,691.00) | 07/13/2021 |
| ELECTRIC FEE | ¤273.00 | 07/13/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 07/13/2021 |
| IMPACT FEE FIRE | ¤367.00 | 07/13/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 07/13/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 07/13/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 07/13/2021 |
| MECHANICAL FEE | ¤273.00 | 07/13/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/13/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 07/13/2021 |
| PLAN CHECK FEE | ¤142.00 | 07/13/2021 |
| PLUMBING FEE | ¤273.00 | 07/13/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤710.00 | 07/13/2021 |
| SITE PLAN 20 | ¤20.00 | 07/13/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 07/13/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 07/13/2021 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/13/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 07/13/2021 |
| SEWER INSPECTION | ¤25.00 | 07/13/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 07/13/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 07/13/2021 |
| METER - DEPOSIT | ¤60.00 | 07/13/2021 |
| WATER- TURN ON | ¤25.00 | 07/13/2021 |
| ADMIN FEE | ¤20.00 | 07/13/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤16,203.93 |