I want to search for...

Permit #2021061118

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7057-00790-0150
Block: 00790
Subdivision: 0 -
Job Phone: 904-742-6790
Location Address: 89 ULLIAN TR
Type: RF - REROOF
Issue Date: 06/18/2021
NOC: RECORDED
Applicant name: CLARK R BRIGGS JR
Owner: FORD TERRY & DONNA H&W

Address

89 ULLIAN TRAIL

PALM COAST, FL 32164

Lot: 0150
Contracted Stated Job Value: ¤11,720.00
Job Description: Re-Roof Shingles, 33 sq 5/12 pitch built in 1999
Type: CN

Contractor

KAYCO ROOFING LLC
Status Location Address State License Number Phone Fax
ACTIVE

1014 BLANDING BLVD

PALM COAST, FL 32137

CCC1328803 (Exp: 08/31/2026) 904-742-6790 904-644-8513

Inspection History

Type Request Date Result Inspector
ROOF FINAL 09/28/2021 FINAL APPROVED TSTAUFFACHER
ROOF IN PROGRESS- MIDROOF 09/22/2021 APPROVED DCUSHING
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 06/28/2021--Roof is complete prior to approval of mid roof. Will need to remove a portion of shingles so underlayment can be verified. THIS IS A REINSPECTION Please call in for 06/22/2021 8-11021... need the following by insulation... 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) First Check at 12.25 PM working on stripping Second check at 2.12PM working on dry-in no drip edge yet. Roof getting stocked at this time. 8-11-21... Midroof inspection was missed and shingles were applied prior to approval. Met crew onsite for destructive inspection and found underlayment did not meet the requirements for double coverage (measured 21 inches between row where crew opened the roof) FURTHER DESTRUCTIVE INSP PERFORMED, ISSSUES RESOLVED
ROOF AFFIDAVIT 09/22/2021 APPROVED STHOMAS
ROOF IN PROGRESS- MIDROOF 08/11/2021 Disapproved - NO FEE WMILLER
Note: THIS IS A REINSPECTION 06/28/2021--Roof is complete prior to approval of mid roof. Will need to remove a portion of shingles so underlayment can be verified. THIS IS A REINSPECTION Please call in for 06/22/2021 8-11021... need the following by insulation... 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) First Check at 12.25 PM working on stripping Second check at 2.12PM working on dry-in no drip edge yet. Roof getting stocked at this time. 8-11-21... Midroof inspection was missed and shingles were applied prior to approval. Met crew onsite for destructive inspection and found underlayment did not meet the requirements for double coverage (measured 21 inches between row where crew opened the roof)
ROOF IN PROGRESS- MIDROOF 06/28/2021 Disapproved - NO FEE TSTAUFFACHER
Note: 06/28/2021--Roof is complete prior to approval of mid roof. Will need to remove a portion of shingles so underlayment can be verified. THIS IS A REINSPECTION Please call in for 06/22/2021 First Check at 12.25 PM working on stripping Second check at 2.12PM working on dry-in no drip edge yet. Roof getting stocked at this time.
ROOF IN PROGRESS- MIDROOF 06/21/2021 Disapproved - NO FEE TSTAUFFACHER
Note: Please call in for 06/22/2021 First Check at 12.25 PM working on stripping Second check at 2.12PM working on dry-in no drip edge yet. Roof getting stocked at this time.

Review History

Department Status Date In Date Out
BADMIN HOLD 06/25/2021 06/25/2021
Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM INCORRECT ROOFING AFFIDAVIT FOR ADDRESS
BADMIN COMPLETE 06/25/2021 06/25/2021
Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 06/18/2021
BUILDING DISCOUNT 100% (¤60.00) 06/18/2021
INSPECTION 40 ¤40.00 06/18/2021
SURCHARGE FS 533.721 ¤2.00 06/18/2021
SURCHARGE - FS 468.631 ¤2.00 06/18/2021
Fees Total Due: ¤0.00 Total Paid: ¤4.00