Permit #2021061601

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7016-00120-0200
Block: 00120
Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE
Job Phone: 386-585-2654
Location Address: 6 CRISTON CT
Type: BA - BUILDING ADDITION
Issue Date: 07/26/2021
NOC: RECORDED
Applicant name: DESIDERIO CARLOS CARREIRO
Owner: CROZIER BRENT & SUZY H&W

Address

6 CRISTON COURT

PALM COAST, FL 32137

Lot: 0200
Contracted Stated Job Value: ¤10,000.00
Job Description: Deck addition and screen enclosure
Type: CN

Contractor

RED LINE CONSTRUCTION CO
Status Location Address State License Number Phone
ACTIVE

6 COMMERCIAL CT

PALM COAST, FL 32137

CGC1527392 (Exp: 08/31/2026) 386-585-2654

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/18/2022 FINAL APPROVED AGAETANO
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION 1. FALL PROTECTION HANDRAILS REQUIRED… R312.1, Guards shall be located along open sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. Insect screening shall not be considered as a guard. 2. Beam To Gutter Detail is not per plans (see highlighted area on plans) 1-31-2022. 1. Screen door landing needs to be 36" wide and width of door. R311. 2. FALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGH.
BLD - BUILDING FINAL 01/31/2022 Disapproved -FEE REQUIRED AGAETANO
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1. FALL PROTECTION HANDRAILS REQUIRED… R312.1, Guards shall be located along open sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. Insect screening shall not be considered as a guard. 2. Beam To Gutter Detail is not per plans (see highlighted area on plans) 1-31-2022. 1. Screen door landing needs to be 36" wide and width of door. R311. 2. FALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGH.
BLD - BUILDING FINAL 01/28/2022 CANCELLED BY APPLICANT AGAETANO
Note: THIS IS A REINSPECTION 1. FALL PROTECTION HANDRAILS REQUIRED… R312.1, Guards shall be located along open sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. Insect screening shall not be considered as a guard. 2. Beam To Gutter Detail is not per plans (see highlighted area on plans)
BLD - BUILDING FINAL 12/10/2021 Disapproved -FEE REQUIRED LMILLER
Note: 1. FALL PROTECTION HANDRAILS REQUIRED… R312.1, Guards shall be located along open sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. Insect screening shall not be considered as a guard. 2. Beam To Gutter Detail is not per plans (see highlighted area on plans)
FRAMING 08/16/2021 APPROVED JPI
FOOTER 08/11/2021 APPROVED WMILLER

Review History

Department Status Date In Date Out
BLD COMPLETE 01/27/2022 01/27/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 07/20/2021 07/26/2021
Note: Released By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM
BADMIN HOLD 07/19/2021 07/19/2021
Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM PLANS DO NOT HAVE DIGITAL SIGNATURE
BADMIN COMPLETE 07/19/2021 07/19/2021
Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM
BLD HOLD 06/28/2021 07/07/2021
Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM Held By: Harold Allen - (386)986-2357 - HAllen@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2020 FLORIDA BUILDING CODE-RESIDENTIAL 1. COMMENT: Provide exterior deck live and dead loads per 2020 FBC-Residential Sections R301.4, R301.5 and Table R301.5. 2. COMMENT: Guards and handrails must be designed for a single concentrated load of 200 p.s.f. applied in any direction at any point along the top. Guard in-fill components must be designed for a 50 p.s.f. horizontal load. See Table R305.1 3. COMMENT: LUS26 Is called-out for 2” x 8” Floor Joist to Header attachment. LS28 is for a 2” x 6” connection. Please revised the call-out for the correct connector. 4. COMMENT: Proposed 2” x 6” Ledger is attached using ¼” Tapcons. Ledgers are to be attached per section R507 2020 Florida Building Code residential 7th Edition. 5. Pressure treated wood is called-out. Please provide species and grade of lumber be used.
ZON COMPLETE 06/28/2021 06/28/2021
Note: Released By: ESTELLE LENS - (386)986-3751 -

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 03/17/2022
REINSPECTION RESIDENTIAL ¤40.00 01/27/2022
PLAN REVIEW - REVISION ¤32.50 01/27/2022
ADMIN FEE ¤20.00 07/26/2021
BUILDING DISCOUNT 100% (¤100.00) 07/26/2021
PLAN CHECK FEE ¤40.00 07/26/2021
REMODEL/ADDITION/ACCES INSPECT ¤40.00 07/26/2021
SITE PLAN 20 ¤20.00 07/26/2021
SURCHARGE FS 533.721 ¤2.00 07/26/2021
SURCHARGE - FS 468.631 ¤2.00 07/26/2021
Fees Total Due: ¤0.00 Total Paid: ¤136.50