Permit #2021061601
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7016-00120-0200 |
| Block: 00120 |
| Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE |
| Job Phone: 386-585-2654 |
| Location Address: 6 CRISTON CT |
| Type: BA - BUILDING ADDITION |
| Issue Date: 07/26/2021 |
| NOC: RECORDED |
| Applicant name: DESIDERIO CARLOS CARREIRO |
| Owner: CROZIER BRENT & SUZY H&W |
|
Address 6 CRISTON COURT PALM COAST, FL 32137 |
| Lot: 0200 |
| Contracted Stated Job Value: ¤10,000.00 |
| Job Description: Deck addition and screen enclosure |
| Type: CN |
Contractor
RED LINE CONSTRUCTION CO
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6 COMMERCIAL CT PALM COAST, FL 32137 |
CGC1527392 (Exp: 08/31/2026) | 386-585-2654 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/18/2022 | FINAL APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION 1. FALL PROTECTION HANDRAILS REQUIRED… R312.1, Guards shall be located along open sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. Insect screening shall not be considered as a guard. 2. Beam To Gutter Detail is not per plans (see highlighted area on plans) 1-31-2022. 1. Screen door landing needs to be 36" wide and width of door. R311. 2. FALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGH. | |||
| BLD - BUILDING FINAL | 01/31/2022 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1. FALL PROTECTION HANDRAILS REQUIRED… R312.1, Guards shall be located along open sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. Insect screening shall not be considered as a guard. 2. Beam To Gutter Detail is not per plans (see highlighted area on plans) 1-31-2022. 1. Screen door landing needs to be 36" wide and width of door. R311. 2. FALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGH. | |||
| BLD - BUILDING FINAL | 01/28/2022 | CANCELLED BY APPLICANT | AGAETANO |
| Note: THIS IS A REINSPECTION 1. FALL PROTECTION HANDRAILS REQUIRED… R312.1, Guards shall be located along open sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. Insect screening shall not be considered as a guard. 2. Beam To Gutter Detail is not per plans (see highlighted area on plans) | |||
| BLD - BUILDING FINAL | 12/10/2021 | Disapproved -FEE REQUIRED | LMILLER |
| Note: 1. FALL PROTECTION HANDRAILS REQUIRED… R312.1, Guards shall be located along open sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. Insect screening shall not be considered as a guard. 2. Beam To Gutter Detail is not per plans (see highlighted area on plans) | |||
| FRAMING | 08/16/2021 | APPROVED | JPI |
| FOOTER | 08/11/2021 | APPROVED | WMILLER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/27/2022 | 01/27/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/20/2021 | 07/26/2021 |
| Note: Released By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 07/19/2021 | 07/19/2021 |
| Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM PLANS DO NOT HAVE DIGITAL SIGNATURE | |||
| BADMIN | COMPLETE | 07/19/2021 | 07/19/2021 |
| Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/28/2021 | 07/07/2021 |
| Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM Held By: Harold Allen - (386)986-2357 - HAllen@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2020 FLORIDA BUILDING CODE-RESIDENTIAL 1. COMMENT: Provide exterior deck live and dead loads per 2020 FBC-Residential Sections R301.4, R301.5 and Table R301.5. 2. COMMENT: Guards and handrails must be designed for a single concentrated load of 200 p.s.f. applied in any direction at any point along the top. Guard in-fill components must be designed for a 50 p.s.f. horizontal load. See Table R305.1 3. COMMENT: LUS26 Is called-out for 2” x 8” Floor Joist to Header attachment. LS28 is for a 2” x 6” connection. Please revised the call-out for the correct connector. 4. COMMENT: Proposed 2” x 6” Ledger is attached using ¼” Tapcons. Ledgers are to be attached per section R507 2020 Florida Building Code residential 7th Edition. 5. Pressure treated wood is called-out. Please provide species and grade of lumber be used. | |||
| ZON | COMPLETE | 06/28/2021 | 06/28/2021 |
| Note: Released By: ESTELLE LENS - (386)986-3751 - |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/17/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/27/2022 |
| PLAN REVIEW - REVISION | ¤32.50 | 01/27/2022 |
| ADMIN FEE | ¤20.00 | 07/26/2021 |
| BUILDING DISCOUNT 100% | (¤100.00) | 07/26/2021 |
| PLAN CHECK FEE | ¤40.00 | 07/26/2021 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 07/26/2021 |
| SITE PLAN 20 | ¤20.00 | 07/26/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 07/26/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 07/26/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤136.50 |