Permit #2021070511

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7016-00100-0390
CONDITIONED SPACE: 2429 sqft
GARAGE: 840 sqft
OPENED PORCH (WITH ROOF) : 167 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
Total Square Footage: 3496 sqft
Block: 00100
Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE
Job Phone: 386-447-7007
Location Address: 8 CHERRYTREE CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/09/2021
NOC: RECORDED
Applicant name: MAXIM TARANNIK
Owner: LUBENSKIY LLYA

Address

4606 FARGO AVE

SKOKIE, IL 60076

Lot: 0390
Contracted Stated Job Value: ¤350,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

GOLDEN MAGNOLIA, INC
Status Location Address State License Number Phone
INACTIVE

1 ROCKEFELLER DRIVE

PALM COAST, FL 32164

RR282811984 (Exp: 08/31/2025) 386-447-7007

Sub Contractors

GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
THOMAS JOSEPH WALL
Status Location Address State License Number Phone
ACTIVE

PO BOX 314

PALAKTKA, FL 32177

CFC037193 (Exp: 08/31/2026) 386-336-9050
BRIAN WOOD
Status Location Address State License Number Phone
ACTIVE

2439 HYATT CREEK LANE

, 0

CAC1821021 (Exp: 08/31/2026) 386-282-1224

Inspection History

Type Request Date Result Inspector
ROW - DRAINAGE 08/14/2023 APPROVED EMADISON
Note: 8/9/2023 - PREVIOUS INSPECTION NOTES ** 08/09/23 AT THE TIME OF THE FINAL ROW BUILDER HAD ATTEMPTED TO REMOVE SEDIMENT FROM ALONG THE SEAWALL WATER WAS VERY CLOUDY FROM RAINS AND REMOVAL PROCESS STILL SEDIMENT THAT NEEDS TO BE REMOVED SPOKE TO BUILDER WHO SAID HE WILL TAKE CARE OF REMOVING MORE SEDIMENT ** FOLLOW UP ON 08/14/23 ______________________________________________________________________________________________________________________ rjg. Please check for stable silt fence and sediment going into canal.
ROW - DRAINAGE 08/09/2023 PARTIALLY APPROVED EMADISON
Note: ** 08/09/23 AT THE TIME OF THE FINAL ROW BUILDER HAD ATTEMPTED TO REMOVE SEDIMENT FROM ALONG THE SEAWALL WATER WAS VERY CLOUDY FROM RAINS AND REMOVAL PROCESS STILL SEDIMENT THAT NEEDS TO BE REMOVED SPOKE TO BUILDER WHO SAID HE WILL TAKE CARE OF REMOVING MORE SEDIMENT ** FOLLOW UP ON 08/14/23 ______________________________________________________________________________________________________________________ rjg. Please check for stable silt fence and sediment going into canal.
ROW - STORMWATER FINAL 08/04/2023 FINAL APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 08/04/2023 APPROVED EMADISON
Note: ** 08/04/23 CORRECTIONS MADE ___________________________________________________________________________________________________________________ 7/27/2023 - PREVIOUS INSPECTION NOTES ** 07/27/23 RIGHT SIDE ALONG PROPERTY FINAL SURVEY INDICATES A COMMON SWALE BUILDER NEEDS TO REMOVE DROP OFFF AND CREATE THE COMMON SWALE BETWEEN #8 AND #6 CHERRYTREE CT. ** RIGHT SIDE ROAD SIDE SWALE NEED TO RE-ESTABLISH SWALE TO HIGH NOT ALLOWING WATER TO FLOW FROM RIGHT TO LEFT ** LEFT SIDE PROPERTY LIJE FROM SEAWALL TOWARDS FRONT BUILDER NEEDS TO REPAIR AND RE-SOD THE ADJACENT PROPERTY # 10 ALONG PROPERTY LINE YOU MUST REPLACE SOD WITH ST. AUGUSTINE WHICH IS WHAT IS ON #10 CHERRYTREE. MUST REPAIR TO LIKE OR BETTER CONDITION ** LEFT SIDE ROAD SIDE SWALE CHECK GRADE TO ENSURE WATER WILL FLOW RIGHT TO LEFT ** ALL AREAS TO BE REPAIRED ARE OUTLINED WITH WHITE PAINT ** SEDIMENT IN CANAL THAT ERODED AND WASHED DURING CONSTRUCTION OF THIS SITE NEEDS TO BE REMOVED
BLD - BUILDING FINAL 08/04/2023 FINAL APPROVED TSTAUFFACHER
Note: 8/2/2023 - PREVIOUS INSPECTION NOTES 08/02/2023- House is good, but energy calcs do not match the unit installed. 7/28/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2320 Need dumpster on site. Remove construction debris and excess dirt 07-28-2023 1. Energy calcs not on site. 2. Entry exterior light not working. 3. Multiple bedroom ceiling lights not working. 4. Disposal not working. 5. Loose outlets. Check all. Inspection stopped.
BLD - BUILDING FINAL 08/02/2023 Disapproved - NO FEE TSTAUFFACHER
Note: 08/02/2023- House is good, but energy calcs do not match the unit installed. 7/28/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2320 Need dumpster on site. Remove construction debris and excess dirt 07-28-2023 1. Energy calcs not on site. 2. Entry exterior light not working. 3. Multiple bedroom ceiling lights not working. 4. Disposal not working. 5. Loose outlets. Check all. Inspection stopped.
BLD - BUILDING FINAL 07/28/2023 Disapproved -FEE REQUIRED AGAETANO
Note: Inspector Notes from Inspection 2320 Need dumpster on site. Remove construction debris and excess dirt 07-28-2023 1. Energy calcs not on site. 2. Entry exterior light not working. 3. Multiple bedroom ceiling lights not working. 4. Disposal not working. 5. Loose outlets. Check all. Inspection stopped.
ROW - FINAL APRON (AFTER POUR) 07/28/2023 FINAL APPROVED EMADISON
U -UTILITY RESIDENTIAL FINAL 07/28/2023 FINAL APPROVED DHANEY
ROW - STORMWATER FINAL 07/28/2023 Disapproved -FEE REQUIRED EMADISON
Note: *** 07/28/23 SPOKE WITH BUILDER ON 07/27/23 IN REGARD TO ALL CORRECTIONS THAT ARE REQUIRED NO CORRECTIVE ACTION TAKEN AT THE TIME OF INSPECTION ** RIGHT SIDE ROAD SIDE SWALE NEED TO RE-ESTABLISH SWALE TO HIGH NOT ALLOWING WATER TO FLOW FROM RIGHT TO LEFT MARKED WITH WHITE PAINT ** RIGHT SIDE ALONG PROPERTY LINE NWHERE LARGE BERM NEED TO REMOVE AND CREATE A COMMON (SWALE) DRAINAGE CONVEYANCE ON RIGHT SIDE ALONG PROPERTY LINE ** LEFT SIDE PROPERTY LIJE FROM SEAWALL TOWARDS FRONT BUILDER NEEDS TO REPAIR AND RE-SOD THE ADJACENT PROPERTY # 10 ALONG PROPERTY LINE YOU MUST REPLACE SOD WITH ST. AUGUSTINE WHICH IS WHAT IS ON #10 CHERRYTREE. MUST REPAIR TO LIKE OR BETTER CONDITION ** LEFT SIDE ROAD SIDE SWALE CHECK GRADE TO ENSURE WATER WILL FLOW RIGHT TO LEFT ** ALL AREAS TO BE REPAIRED ARE OUTLINED WITH WHITE PAINT ** SEDIMENT IN CANAL THAT ERODED AND WASHED DURING CONSTRUCTION OF THIS SITE NEEDS TO BE REMOVED __________________________________________________________________________________________________________________ ** NOTE INSPECTOR ENSURE THAT SEDIMENT FROM WASHOUTS INTO CANAL IS TAKEN CARE OF. EM ** ANY SEDIMENT THAT HAS IMPACTED THE ADJACENT PROPERTIES NEEDS TO BE CLEANED UP.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/27/2023 APPROVED EMADISON
Note: 7/24/2023 - PREVIOUS INSPECTION NOTES ** 07/24/23 NO CORRECTIONS MADE SINCE PREVIOUS FINAL SURVEY INSPECTION ** YOUR CULVERT INVERT NUMBERS **DO NOT** MATCH THE SWALE PLAN DIAGRAM OUT OF TOLERANCE ** ALL HARD SHOTS NEED TO BE TO THE 100TH (CENTER LINE OF ROAD INCLUDED) _______________________________________________________________________________________________________________________ 7/12/2023 - PREVIOUS INSPECTION NOTES ** 07/12/23 YOUR CULVERT INVERT NUMBERS **DO NOT** MATCH THE SWALE PLAN DIAGRAM ** ** ALL HARD SHOTS NEED TO BE TO THE 100TH (CENTER LINE OF ROAD INCLUDED) ______________________________________________________________________________________________________________________ 7/7/2023 - PREVIOUS INSPECTION NOTES ** 07/07/23 NEED TO CLEAN UP FINAL SURVEY ELEVATION SHOTS ON PROPERTY LINE NOT CLEAR AS THEY ARE ON THE LINE HARD TO READ AS WELL AS MANY OTHER ELEVATION NUMBERS MIXED WITH OTHER INFO ** CENTER ELEVATION SHOT IN REAR YARD SHOWS (2.3) THATS A 7 FOOT DROP FROM REAR OF HOUSE AND 4 FEET LOWER THAN SHOTS ON EITHER SIDE OF IT ** TOO MUCH GOING ON IN SWALE AND INVERT SHOTS NEED TO CLEAN IT UP ** ALL HARD SHOTS NEED TO BE TO THE 100TH (CENTER LINE OF ROAD INCLUDED)
ROW FIELD SURVEY /GRADING CERTIFICATION 07/27/2023 Disapproved - NO FEE EMADISON
Note: ** 07/27/23 RIGHT SIDE ALONG PROPERTY FINAL SURVEY INDICATES A COMMON SWALE BUILDER NEEDS TO REMOVE DROP OFFF AND CREATE THE COMMON SWALE BETWEEN #8 AND #6 CHERRYTREE CT. ** RIGHT SIDE ROAD SIDE SWALE NEED TO RE-ESTABLISH SWALE TO HIGH NOT ALLOWING WATER TO FLOW FROM RIGHT TO LEFT ** LEFT SIDE PROPERTY LIJE FROM SEAWALL TOWARDS FRONT BUILDER NEEDS TO REPAIR AND RE-SOD THE ADJACENT PROPERTY # 10 ALONG PROPERTY LINE YOU MUST REPLACE SOD WITH ST. AUGUSTINE WHICH IS WHAT IS ON #10 CHERRYTREE. MUST REPAIR TO LIKE OR BETTER CONDITION ** LEFT SIDE ROAD SIDE SWALE CHECK GRADE TO ENSURE WATER WILL FLOW RIGHT TO LEFT ** ALL AREAS TO BE REPAIRED ARE OUTLINED WITH WHITE PAINT ** SEDIMENT IN CANAL THAT ERODED AND WASHED DURING CONSTRUCTION OF THIS SITE NEEDS TO BE REMOVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/24/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 07/24/23 NO CORRECTIONS MADE SINCE PREVIOUS FINAL SURVEY INSPECTION ** YOUR CULVERT INVERT NUMBERS **DO NOT** MATCH THE SWALE PLAN DIAGRAM OUT OF TOLERANCE ** ALL HARD SHOTS NEED TO BE TO THE 100TH (CENTER LINE OF ROAD INCLUDED) _______________________________________________________________________________________________________________________ 7/12/2023 - PREVIOUS INSPECTION NOTES ** 07/12/23 YOUR CULVERT INVERT NUMBERS **DO NOT** MATCH THE SWALE PLAN DIAGRAM ** ** ALL HARD SHOTS NEED TO BE TO THE 100TH (CENTER LINE OF ROAD INCLUDED) ______________________________________________________________________________________________________________________ 7/7/2023 - PREVIOUS INSPECTION NOTES ** 07/07/23 NEED TO CLEAN UP FINAL SURVEY ELEVATION SHOTS ON PROPERTY LINE NOT CLEAR AS THEY ARE ON THE LINE HARD TO READ AS WELL AS MANY OTHER ELEVATION NUMBERS MIXED WITH OTHER INFO ** CENTER ELEVATION SHOT IN REAR YARD SHOWS (2.3) THATS A 7 FOOT DROP FROM REAR OF HOUSE AND 4 FEET LOWER THAN SHOTS ON EITHER SIDE OF IT ** TOO MUCH GOING ON IN SWALE AND INVERT SHOTS NEED TO CLEAN IT UP ** ALL HARD SHOTS NEED TO BE TO THE 100TH (CENTER LINE OF ROAD INCLUDED)
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/12/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 07/12/23 YOUR CULVERT INVERT NUMBERS **DO NOT** MATCH THE SWALE PLAN DIAGRAM ** ** ALL HARD SHOTS NEED TO BE TO THE 100TH (CENTER LINE OF ROAD INCLUDED) ______________________________________________________________________________________________________________________ 7/7/2023 - PREVIOUS INSPECTION NOTES ** 07/07/23 NEED TO CLEAN UP FINAL SURVEY ELEVATION SHOTS ON PROPERTY LINE NOT CLEAR AS THEY ARE ON THE LINE HARD TO READ AS WELL AS MANY OTHER ELEVATION NUMBERS MIXED WITH OTHER INFO ** CENTER ELEVATION SHOT IN REAR YARD SHOWS (2.3) THATS A 7 FOOT DROP FROM REAR OF HOUSE AND 4 FEET LOWER THAN SHOTS ON EITHER SIDE OF IT ** TOO MUCH GOING ON IN SWALE AND INVERT SHOTS NEED TO CLEAN IT UP ** ALL HARD SHOTS NEED TO BE TO THE 100TH (CENTER LINE OF ROAD INCLUDED)
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/07/2023 Disapproved - NO FEE EMADISON
Note: ** 07/07/23 NEED TO CLEAN UP FINAL SURVEY ELEVATION SHOTS ON PROPERTY LINE NOT CLEAR AS THEY ARE ON THE LINE HARD TO READ AS WELL AS MANY OTHER ELEVATION NUMBERS MIXED WITH OTHER INFO ** CENTER ELEVATION SHOT IN REAR YARD SHOWS (2.3) THATS A 7 FOOT DROP FROM REAR OF HOUSE AND 4 FEET LOWER THAN SHOTS ON EITHER SIDE OF IT ** TOO MUCH GOING ON IN SWALE AND INVERT SHOTS NEED TO CLEAN IT UP ** ALL HARD SHOTS NEED TO BE TO THE 100TH (CENTER LINE OF ROAD INCLUDED)
ELECTRIC - EARLY POWER 06/08/2023 APPROVED - AS NOTED AGAETANO
Note: 06-08-2023 FPL notified at 9:02. [F] 501.2 Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address identification shall be maintained.
GRAVITY SEWER TEST 05/30/2023 APPROVED MGIBSON
Note: 5/26/2023 - PREVIOUS INSPECTION NOTES NOT READY FOR INSPECTION STILL WORKING
U - SEWER TIE IN 05/30/2023 APPROVED MGIBSON
Note: 5/26/2023 - PREVIOUS INSPECTION NOTES TAP NOT MADE
U-CROSS CONNECTION 05/30/2023 APPROVED - AS NOTED DHANEY
Note: 5/26/2023 - PREVIOUS INSPECTION NOTES Could not locate water meter pit . NOTE: At time of utility final, you will need to have installed a additional water meter pit base on top of existing one to bring up lid height .
U-CROSS CONNECTION 05/26/2023 Disapproved - NO FEE DHANEY
Note: Could not locate water meter pit .
U - SEWER TIE IN 05/26/2023 Disapproved - NO FEE MGIBSON
Note: TAP NOT MADE
GRAVITY SEWER TEST 05/26/2023 Disapproved -FEE REQUIRED MGIBSON
Note: NOT READY FOR INSPECTION STILL WORKING
ROW- PRE-APRON (PRE-POUR) 05/22/2023 APPROVED EMADISON
Note: ** 05/22/23 READY TO POUR BUILDERS RESPONSIBILITY TO ENSURE CULVERT ELEVATION IS WITHIN TOLERANCE BEFORE THE POUR IN THE EVENT OF RAIN CHECK COMPACTION OF MATERIAL **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
LATH/BRICK/ WATER BARRIER 05/02/2023 APPROVED - AS NOTED KSANDOE
Note: Need dumpster on site. Remove construction debris and excess dirt
ALL ROUGH 04/26/2023 APPROVED TSTAUFFACHER
Note: 4/21/2023 - PREVIOUS INSPECTION NOTES 04/21/2023 1.Need 5' head pressure on drain lines 2.Install slider in rear//slider in onsite 3.Install protection plates abe electric panel/ both sides 4/18/2023 - PREVIOUS INSPECTION NOTES 04/18/2023 1.Load bearing wall missing blocking -pg. 3 on plans 2.Gable end framing not per detail pg 4 3.Truss T06 multiple repairs-provide engineering and fix for repair- must be submitted to city for approval 4. Missing engineering on Truss - T02, T05,T06,T08 INSPECTION STOPPED- PLEASE WALK HOUSE WITH FRAMER TO VERIFY WORK IS PER PLANS AND CODE COMPLIANT-THIS IS NOT A COMPLETE LIST Inspector Notes from Inspection 2450 Please clean jobsite- remove excess block, concrete over pour, repair silt fencing - soil falling into canal.
INSULATION 04/26/2023 APPROVED TSTAUFFACHER
ALL ROUGH 04/21/2023 Disapproved - NO FEE TSTAUFFACHER
Note: 04/21/2023--OK to insulate 1.Need 5' head pressure on drain lines 2.Install slider in rear//slider in onsite 3.Install protection plates abe electric panel/ both sides 4/18/2023 - PREVIOUS INSPECTION NOTES 04/18/2023 1.Load bearing wall missing blocking -pg. 3 on plans 2.Gable end framing not per detail pg 4 3.Truss T06 multiple repairs-provide engineering and fix for repair- must be submitted to city for approval 4. Missing engineering on Truss - T02, T05,T06,T08 INSPECTION STOPPED- PLEASE WALK HOUSE WITH FRAMER TO VERIFY WORK IS PER PLANS AND CODE COMPLIANT-THIS IS NOT A COMPLETE LIST Inspector Notes from Inspection 2450 Please clean jobsite- remove excess block, concrete over pour, repair silt fencing - soil falling into canal.
ALL ROUGH 04/18/2023 Disapproved - NO FEE TSTAUFFACHER
Note: 04/18/2023 1.Load bearing wall missing blocking -pg. 3 on plans 2.Gable end framing not per detail pg 4 3.Truss T06 multiple repairs-provide engineering and fix for repair- must be submitted to city for approval 4. Missing engineering on Truss - T02, T05,T06,T08 INSPECTION STOPPED- PLEASE WALK HOUSE WITH FRAMER TO VERIFY WORK IS PER PLANS AND CODE COMPLIANT-THIS IS NOT A COMPLETE LIST Inspector Notes from Inspection 2450 Please clean jobsite- remove excess block, concrete over pour, repair silt fencing - soil falling into canal.
WALL SHEATHING 04/05/2023 APPROVED - AS NOTED TSTAUFFACHER
Note: Please clean jobsite- remove excess block, concrete over pour, repair silt fencing - soil falling into canal.
ROW - DRAINAGE 03/01/2023 APPROVED PFLANAGAN
Note: 2/24/2023 - PREVIOUS INSPECTION NOTES TALKED TO CONTRACTOR YESTERDAY AFTERNOON AND GIVING THEM TILL 3/1/2023 TO FIX ALL ISSUES. IF WORK IS NOT COMPLETED NEED TO PUT STOP WORK ON THIS PERMIT ----------------------------------------------------------------------------------------------------------- 2/23/2023 - PREVIOUS INSPECTION NOTES NONE OF THE ISSUES HAVE BEEN ADDRESSED YOU HAVE INTILL TOMORROWS INSPECTION TO MAKE ALL CORRECTION OR THERE WILL BE A STOP WORK ON THIS PERMIT ------------------------------------------------------------------------------------------- 2/22/2023 - PREVIOUS INSPECTION NOTES 1) RE-ESTABLISH THE SILT FENCES 2) NEED TO HAVE ALL SEDIMENT CLEANED OUT OF THE CANAL YOU HAVE INTILL THE INSPECTION ON FRIDAY AND IF ALL ISSUES ARE NOT ADDRESSED THERE WILL BE A STOP WORK ON THIS PERMIT NEXT INSPECTION IS 2/23/2023 -------------------------------------------------------------------------------------------------- 2/21/2023 - PREVIOUS INSPECTION NOTES NEED TO DO THE FOLLOWING 1) RE-ESTABLISH SILT FENCES 2) NEED TO CLEAN OUT SEDIMENT FROM CANAL NEXT INSPECTION ON 2/22/2023 YOU HAVE INTILL FRIDAY TO FIX ALL AREAS BEFORE A STOP WORK IS PLACED ON THIS PERMIT --------------------------------------------------------------------------------------------- 2/13/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO RE-ESTABLISH ALL SILT FENCES SO THEY WORK CORRECTLY 2) NEED TO DIG ALL SEDIMENT OUT OF CANAL 3) NEED TO PICK UP ALL TRASH AROUND THE CONSTRUCTION SITE NEXT INSPECTION ON 2/21/2023
ROW - DRAINAGE 02/24/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: TALKED TO CONTRACTOR YESTERDAY AFTERNOON AND GIVING THEM TILL 3/1/2023 TO FIX ALL ISSUES. IF WORK IS NOT COMPLETED NEED TO PUT STOP WORK ON THIS PERMIT ----------------------------------------------------------------------------------------------------------- 2/23/2023 - PREVIOUS INSPECTION NOTES NONE OF THE ISSUES HAVE BEEN ADDRESSED YOU HAVE INTILL TOMORROWS INSPECTION TO MAKE ALL CORRECTION OR THERE WILL BE A STOP WORK ON THIS PERMIT ------------------------------------------------------------------------------------------- 2/22/2023 - PREVIOUS INSPECTION NOTES 1) RE-ESTABLISH THE SILT FENCES 2) NEED TO HAVE ALL SEDIMENT CLEANED OUT OF THE CANAL YOU HAVE INTILL THE INSPECTION ON FRIDAY AND IF ALL ISSUES ARE NOT ADDRESSED THERE WILL BE A STOP WORK ON THIS PERMIT NEXT INSPECTION IS 2/23/2023 -------------------------------------------------------------------------------------------------- 2/21/2023 - PREVIOUS INSPECTION NOTES NEED TO DO THE FOLLOWING 1) RE-ESTABLISH SILT FENCES 2) NEED TO CLEAN OUT SEDIMENT FROM CANAL NEXT INSPECTION ON 2/22/2023 YOU HAVE INTILL FRIDAY TO FIX ALL AREAS BEFORE A STOP WORK IS PLACED ON THIS PERMIT --------------------------------------------------------------------------------------------- 2/13/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO RE-ESTABLISH ALL SILT FENCES SO THEY WORK CORRECTLY 2) NEED TO DIG ALL SEDIMENT OUT OF CANAL 3) NEED TO PICK UP ALL TRASH AROUND THE CONSTRUCTION SITE NEXT INSPECTION ON 2/21/2023
ROW - DRAINAGE 02/23/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: NONE OF THE ISSUES HAVE BEEN ADDRESSED YOU HAVE INTILL TOMORROWS INSPECTION TO MAKE ALL CORRECTION OR THERE WILL BE A STOP WORK ON THIS PERMIT ------------------------------------------------------------------------------------------- 2/22/2023 - PREVIOUS INSPECTION NOTES 1) RE-ESTABLISH THE SILT FENCES 2) NEED TO HAVE ALL SEDIMENT CLEANED OUT OF THE CANAL YOU HAVE INTILL THE INSPECTION ON FRIDAY AND IF ALL ISSUES ARE NOT ADDRESSED THERE WILL BE A STOP WORK ON THIS PERMIT NEXT INSPECTION IS 2/23/2023 -------------------------------------------------------------------------------------------------- 2/21/2023 - PREVIOUS INSPECTION NOTES NEED TO DO THE FOLLOWING 1) RE-ESTABLISH SILT FENCES 2) NEED TO CLEAN OUT SEDIMENT FROM CANAL NEXT INSPECTION ON 2/22/2023 YOU HAVE INTILL FRIDAY TO FIX ALL AREAS BEFORE A STOP WORK IS PLACED ON THIS PERMIT --------------------------------------------------------------------------------------------- 2/13/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO RE-ESTABLISH ALL SILT FENCES SO THEY WORK CORRECTLY 2) NEED TO DIG ALL SEDIMENT OUT OF CANAL 3) NEED TO PICK UP ALL TRASH AROUND THE CONSTRUCTION SITE NEXT INSPECTION ON 2/21/2023
ROW - DRAINAGE 02/22/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) RE-ESTABLISH THE SILT FENCES 2) NEED TO HAVE ALL SEDIMENT CLEANED OUT OF THE CANAL YOU HAVE INTILL THE INSPECTION ON FRIDAY AND IF ALL ISSUES ARE NOT ADDRESSED THERE WILL BE A STOP WORK ON THIS PERMIT NEXT INSPECTION IS 2/22/2023 -------------------------------------------------------------------------------------------------- 2/21/2023 - PREVIOUS INSPECTION NOTES NEED TO DO THE FOLLOWING 1) RE-ESTABLISH SILT FENCES 2) NEED TO CLEAN OUT SEDIMENT FROM CANAL NEXT INSPECTION ON 2/22/2023 YOU HAVE INTILL FRIDAY TO FIX ALL AREAS BEFORE A STOP WORK IS PLACED ON THIS PERMIT --------------------------------------------------------------------------------------------- 2/13/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO RE-ESTABLISH ALL SILT FENCES SO THEY WORK CORRECTLY 2) NEED TO DIG ALL SEDIMENT OUT OF CANAL 3) NEED TO PICK UP ALL TRASH AROUND THE CONSTRUCTION SITE NEXT INSPECTION ON 2/21/2023
ROW - DRAINAGE 02/21/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: NEED TO DO THE FOLLOWING 1) RE-ESTABLISH SILT FENCES 2) NEED TO CLEAN OUT SEDIMENT FROM CANAL NEXT INSPECTION ON 2/22/2023 YOU HAVE INTILL FRIDAY TO FIX ALL AREAS BEFORE A STOP WORK IS PLACED ON THIS PERMIT --------------------------------------------------------------------------------------------- 2/13/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO RE-ESTABLISH ALL SILT FENCES SO THEY WORK CORRECTLY 2) NEED TO DIG ALL SEDIMENT OUT OF CANAL 3) NEED TO PICK UP ALL TRASH AROUND THE CONSTRUCTION SITE NEXT INSPECTION ON 2/21/2023
ROW - DRAINAGE 02/13/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO RE-ESTABLISH ALL SILT FENCES SO THEY WORK CORRECTLY 2) NEED TO DIG ALL SEDIMENT OUT OF CANAL 3) NEED TO PICK UP ALL TRASH AROUND THE CONSTRUCTION SITE NEXT INSPECTION ON 2/21/2023
ROOF VALLEY & METAL 02/06/2023 APPROVED TSTAUFFACHER
Note: 2/3/2023 - PREVIOUS INSPECTION NOTES 02-03-2023 Contractor not ready.
ROOF VALLEY & METAL 02/03/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 02-03-2023 Contractor not ready. 2:20 pm
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/30/2023 APPROVED BTAYLOR
Note: New inspection due to canceled inspection 1/26/2023 - PREVIOUS INSPECTION NOTES 1/25/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection New inspection due to canceled inspection Inspector Notes from Inspection 2340 Soil has collapsed under back lanai slab. 01-25-2023 1. Please provide an Approved set of drawings for inspection.NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Engineering packet is disorganized. Please organize for inspection. 2. ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2. R319.1 Residential R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 01-26-2023 1. Missing sheets 4,6,9. All details missing. 2. Engineering packet not complete. 3. Gable end anchors not installed completely. No details. Inspection stopped.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/27/2023 CANCELLED BY APPLICANT WEB
Note: 1/26/2023 - PREVIOUS INSPECTION NOTES 1/25/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection New inspection due to canceled inspection Inspector Notes from Inspection 2340 Soil has collapsed under back lanai slab. 01-25-2023 1. Please provide an Approved set of drawings for inspection.NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Engineering packet is disorganized. Please organize for inspection. 2. ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2. R319.1 Residential R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 01-26-2023 1. Missing sheets 4,6,9. All details missing. 2. Engineering packet not complete. 3. Gable end anchors not installed completely. No details. Inspection stopped.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/26/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 1/25/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection New inspection due to canceled inspection Inspector Notes from Inspection 2340 Soil has collapsed under back lanai slab. 01-25-2023 1. Please provide an Approved set of drawings for inspection.NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Engineering packet is disorganized. Please organize for inspection. 2. ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2. R319.1 Residential R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 01-26-2023 1. Missing sheets 4,6,9. All details missing. 2. Engineering packet not complete. 3. Gable end anchors not installed completely. No details. Inspection stopped.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/25/2023 Disapproved -FEE REQUIRED AGAETANO
Note: New inspection due to canceled inspection New inspection due to canceled inspection Inspector Notes from Inspection 2340 Soil has collapsed under back lanai slab. 01-25-2023 1. Please provide an Approved set of drawings for inspection.NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Engineering packet is disorganized. Please organize for inspection. 2. ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2. R319.1 Residential R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/23/2023 CANCELLED BY APPLICANT WEB
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2340 Soil has collapsed under back lanai slab.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/10/2023 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2340 Soil has collapsed under back lanai slab.
TIE BEAM / LINTEL 08/24/2022 APPROVED - AS NOTED AGAETANO
Note: Soil has collapsed under back lanai slab.
FOUND SURVEY APPROVED (OFFICE) 06/29/2022 APPROVED TBAKER
MONOLITHIC SLAB 06/03/2022 APPROVED RMARTIN
Note: THIS IS A REINSPECTION footing walls have slumped in and no longer meet the detail reqquirements (check right side)
ROW - DRAINAGE 06/02/2022 APPROVED - AS NOTED EMADISON
Note: * CORRECTIONS HAVE BEEN MADE NEED TO CONTINUE TO MONITOR THE EROSION ON SITE TO PREVENT ANY FURTHER NEGATIVE IMPACT FROM OCCURING TO CANAL AND ADJACENT PROPERTIES. EM * RESCHEDULE INSPECTION FOR 05/23/22 * SILT FENCE AT REAR OF PROPERTY NOT INSTALLED PROPERLY AND WILL NOT CATCH SEDIMENT IN THE EVENT OF RAIN, WHICH WILL HAVE IMPACT ON THE CANAL (WATERWAY) * SILT FENCE AT REAR LEFT SIDE OF PROPERTY IS NOT INSTALLED PROPERLY AND WILL ALLOW FOR SEDIMENT TO IMPACT AJACENT PROPERTY AT #10 CHERRYTREE. * THE RIGHT SIDE OF PROPERTY DOES NOT HAVE A SILT FENCE INSTALLED AS THE EXISTING ONE THERE IS FOR #6 CHERRYTREE CT. * 05/16/22 NO REPAIRS HAVE BEEN MADE AT THIS TIME, SEDIMENT IS WASHING ONTO NEIGHBORING PROPERTY #10 CHERRYTREE CT LEFT SIDE WITH A NEGATIVE IMPACT * SILT FENCE ON RIGHT SIDE IS INSUFFICENT ALLOWING SEDIMENT TO WASH ONTO NEIGHBORING PROPERTY #6 CHERRYTREE CT RIGHT SIDE, WITH A NEGATIVE IMPACT * SEVERE EROSION IS OCCURRING AT THIS PROJECT SITE SILT FENCE ACROSS BACK OF PROPERTY IS DOWN ALLOWING SEDIMENT TO WASH INTO CANAL, 5/23/22 - Silt fence at the seawall has collapsed in two places and is allowing sediment to flow into the waterway. Next Inspection 6/2/22. * SILT FENCE ON LEFT REAR PROPERTY LINE NEEDS TO BE REPAIRED, TO PREVENT FURTHER WASHOUTS
MONOLITHIC SLAB 06/01/2022 Disapproved - NO FEE LMILLER
Note: footing walls have slumped in and no longer meet the detail reqquirements (check right side)
PLUMBING 1ST ROUGH UNDERGROUND 05/23/2022 APPROVED MGIBSON
ROW - DRAINAGE 05/23/2022 Disapproved -FEE REQUIRED RGROSS
Note: * RESCHEDULE INSPECTION FOR 05/23/22 * SILT FENCE AT REAR OF PROPERTY NOT INSTALLED PROPERLY AND WILL NOT CATCH SEDIMENT IN THE EVENT OF RAIN, WHICH WILL HAVE IMPACT ON THE CANAL (WATERWAY) * SILT FENCE AT REAR LEFT SIDE OF PROPERTY IS NOT INSTALLED PROPERLY AND WILL ALLOW FOR SEDIMENT TO IMPACT AJACENT PROPERTY AT #10 CHERRYTREE. * THE RIGHT SIDE OF PROPERTY DOES NOT HAVE A SILT FENCE INSTALLED AS THE EXISTING ONE THERE IS FOR #6 CHERRYTREE CT. * 05/16/22 NO REPAIRS HAVE BEEN MADE AT THIS TIME, SEDIMENT IS WASHING ONTO NEIGHBORING PROPERTY #10 CHERRYTREE CT LEFT SIDE WITH A NEGATIVE IMPACT * SILT FENCE ON RIGHT SIDE IS INSUFFICENT ALLOWING SEDIMENT TO WASH ONTO NEIGHBORING PROPERTY #6 CHERRYTREE CT RIGHT SIDE, WITH A NEGATIVE IMPACT * SEVERE EROSION IS OCCURRING AT THIS PROJECT SITE SILT FENCE ACROSS BACK OF PROPERTY IS DOWN ALLOWING SEDIMENT TO WASH INTO CANAL, 5/23/22 - Silt fence at the seawall has collapsed in two places and is allowing sediment to flow into the waterway. Next Inspection 6/2/22. * SILT FENCE ON LEFT REAR PROPERTY LINE NEEDS TO BE REPAIRED, TO PREVENT FURTHER WASHOUTS
ROW - DRAINAGE 05/19/2022 Disapproved -FEE REQUIRED EMADISON
Note: * SILT FENCE AT REAR OF PROPERTY NOT INSTALLED PROPERLY AND WILL NOT CATCH SEDIMENT IN THE EVENT OF RAIN, WHICH WILL HAVE IMPACT ON THE CANAL (WATERWAY) * SILT FENCE AT REAR LEFT SIDE OF PROPERTY IS NOT INSTALLED PROPERLY AND WILL ALLOW FOR SEDIMENT TO IMPACT AJACENT PROPERTY AT #10 CHERRYTREE. * THE RIGHT SIDE OF PROPERTY DOES NOT HAVE A SILT FENCE INSTALLED AS THE EXISTING ONE THERE IS FOR #6 CHERRYTREE CT. * SILT FENCE NEED TO BE BURIED 4 INCH IN THE GROUND * 05/16/22 NO REPAIRS HAVE BEEN MADE AT THIS TIME, SEDIMENT IS WASHING ONTO NEIGHBORING PROPERTY #10 CHERRYTREE CT LEFT SIDE WITH A NEGATIVE IMPACT * SILT FENCE ON RIGHT SIDE IS INSUFFICENT ALLOWING SEDIMENT TO WASH ONTO NEIGHBORING PROPERTY #6 CHERRYTREE CT RIGHT SIDE, WITH A NEGATIVE IMPACT * SEVERE EROSION IS OCCURRING AT THIS PROJECT SITE SILT FENCE ACROSS BACK OF PROPERTY IS DOWN ALLOWING SEDIMENT TO WASH INTO CANAL, * SILT FENCE ON LEFT REAR PROPERTY LINE NEEDS TO BE REPAIRED, TO PREVENT FURTHER WASHOUTS
ROW - DRAINAGE 05/16/2022 Disapproved -FEE REQUIRED EMADISON
Note: * 05/16/22 NO REPAIRS HAVE BEEN MADE AT THIS TIME, SEDIMENT IS WASHING ONTO NEIGHBORING PROPERTY #10 CHERRYTREE CT LEFT SIDE WITH A NEGATIVE IMPACT * SILT FENCE ON RIGHT SIDE IS INSUFFICENT ALLOWING SEDIMENT TO WASH ONTO NEIGHBORING PROPERTY #6 CHERRYTREE CT RIGHT SIDE, WITH A NEGATIVE IMPACT * SEVERE EROSION IS OCCURRING AT THIS PROJECT SITE SILT FENCE ACROSS BACK OF PROPERTY IS DOWN ALLOWING SEDIMENT TO WASH INTO CANAL, * SILT FENCE ON LEFT REAR PROPERTY LINE NEEDS TO BE REPAIRED, TO PREVENT FURTHER WASHOUTS
ROW - DRAINAGE 05/11/2022 Disapproved - NO FEE EMADISON
Note: * SILT FENCE ON LEFT REAR PROPERTY LINE NEEDS TO BE REPAIRED, TO PREVENT FURTHER WASHOUTS
WATER METER INSTALLATION REQUEST 12/03/2021 APPROVED TCHURCHILL
PROJECT STATUS (OFFICE USE) 11/15/2021 Disapproved -FEE REQUIRED KRUTH
Note: silt fence needs to be installed asap the lo has been cleared almost a month next inspection on friday

Review History

Department Status Date In Date Out
MECH COMPLETE 08/02/2023 08/04/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 07/31/2023 08/01/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 07/18/2023 07/18/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM MAIN CONTRACTOR INACTIVE
BLD COMPLETE 12/27/2022 12/28/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ELEC COMPLETE 12/27/2022 12/28/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
MECH COMPLETE 12/27/2022 12/28/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON COMPLETE 12/27/2022 12/28/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BADMIN INFORMATION 11/07/2022 11/07/2022
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The required file naming convention is to be followed for all documents uploaded. Please refer to website for the document submittal requirements (file naming).
ENGIN1 COMPLETE 06/29/2022 06/29/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/29/2022 06/29/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
PLFM COMPLETE 07/21/2021 07/22/2021
Note: Released By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM According to the Site Plan submitted on 7/7/21, the structure will fall outside of the Special Flood Hazard Area. No elevation certificates will be required.
BLD COMPLETE 07/12/2021 07/18/2021
Note: Released By: JPI
CUSVC COMPLETE 07/12/2021 07/16/2021
Note: Released By: ALYSSA ROSCOE - -
ELEC COMPLETE 07/12/2021 07/14/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/12/2021 07/12/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 07/12/2021 07/14/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 07/12/2021 07/13/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 07/12/2021 07/20/2021
Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM
ZON COMPLETE 07/12/2021 07/21/2021
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 07/12/2021 09/29/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 08/04/2023
PLAN REVIEW - REVISION ¤32.50 08/04/2023
REINSPECTION RESIDENTIAL ¤40.00 08/04/2023
REINSPECTION RESIDENTIAL ¤40.00 08/04/2023
REINSPECTION RESIDENTIAL ¤40.00 08/04/2023
REINSPECTION RESIDENTIAL ¤40.00 08/04/2023
REINSPECTION RESIDENTIAL ¤40.00 08/04/2023
CONTRACTOR CHANGE ¤40.00 08/04/2023
CONTRACTOR CHANGE ¤20.00 08/04/2023
CONTRACTOR CHANGE ¤20.00 08/04/2023
SW ENG - INSPECTION 20 ¤20.00 08/04/2023
SW ENG - INSPECTION 20 ¤20.00 08/04/2023
SW ENG - INSPECTION 20 ¤20.00 08/04/2023
SW ENG - INSPECTION 20 ¤20.00 08/04/2023
SW ENG - INSPECTION 20 ¤20.00 08/04/2023
SW ENG - INSPECTION 20 ¤20.00 08/04/2023
SW ENG - INSPECTION 20 ¤20.00 08/04/2023
SW ENG - INSPECTION 20 ¤20.00 08/04/2023
SW ENG - INSPECTION 20 ¤20.00 08/04/2023
SW ENG - INSPECTION 20 ¤20.00 08/04/2023
SW ENG REINSPECTION 20 ¤20.00 08/04/2023
REINSPECTION FEE ¤40.00 02/07/2022
SW ENG - INSPECTION 20 ¤20.00 02/07/2022
METER - DEPOSIT ¤60.00 11/09/2021
WATER- TURN ON ¤25.00 11/09/2021
ADMIN FEE ¤20.00 11/09/2021
NEW RESIDENTIAL INSPECTIONS ¤700.00 11/09/2021
SITE PLAN 20 ¤20.00 11/09/2021
SURCHARGE FS 533.721 ¤2.00 11/09/2021
SURCHARGE - FS 468.631 ¤2.00 11/09/2021
STORM WATER PERMIT FEES ¤80.00 11/09/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 11/09/2021
SEWER CREDIT (¤1,147.00) 11/09/2021
SEWER INSPECTION ¤25.00 11/09/2021
SEWER CAPITAL FACILITY ¤4,664.55 11/09/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 11/09/2021
BUILDING DISCOUNT 100% (¤1,670.00) 11/09/2021
ELECTRIC FEE ¤270.00 11/09/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 11/09/2021
IMPACT FEE FIRE ¤367.00 11/09/2021
IMPACT FEE PARKS ¤1,199.12 11/09/2021
IMPACT FEE SCHOOL ¤3,600.00 11/09/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 11/09/2021
MECHANICAL FEE ¤270.00 11/09/2021
WATER -IRRIGATION INSPECTION ¤25.00 11/09/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 11/09/2021
PLAN CHECK FEE ¤140.00 11/09/2021
PLUMBING FEE ¤270.00 11/09/2021
CONNECTION FEES ¤1,017.83 11/09/2021
SW ENG - INSPECTION 20 ¤20.00
SW ENG - INSPECTION 20 ¤20.00
Fees Total Due: ¤40.00 Total Paid: ¤15,609.43