I want to search for...

Permit #2021070593

Permit Details

Status: COED

Parcel Id: 07-11-31-7016-00120-1300
Block: 00120
Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE
Job Phone: 904-759-6435
Location Address: 10 CURTIS CT
Type: RF - REROOF
Issue Date: 07/13/2021
NOC: RECORDED
Applicant name: DAVID GLENN ENGLAND
Owner: LUMAJ FRANK P & DIELLE H&W

Address

10 CURTIS COURT

PALM COAST, FL 32137

Lot: 1300
Contracted Stated Job Value: ¤10,000.00
Job Description: re-roof 10124.1
Type: CN

Contractor

ENGLAND CLASSIC ROOFING INC
Status Location Address State License Number Phone
ACTIVE

PO BOX 840006

ST AUGUSTINE, FL 32080

CCC1330631 (Exp: 08/31/2026) 904-759-6435

Inspection History

Type Request Date Result Inspector
ROOF IN PROGRESS- MIDROOF 08/25/2021 APPROVED DCUSHING
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION no one here for unspection (destructive inspection needed, passed midroof inspection without inspection as required 7-23-21... cancelled (raining) 7-27-21... DESTRUCTIVE INSPECTION PERFORMED missing manufacturers overlap on underlayment...missing second layer, Per FBC, section R905.1.1.1 remove all roof coverings and underlayment reapply underlayment and drip edge and call fir midroof with no more than 20 % OF SHINGLES APPLIED AND HAVE ALL DOCUMENTS ON SITE FOR INSPECTION (summit 60 was used and requires a 2 inch overlap) Contractor addressed issues and opened for inspection - OK to final
ROOF FINAL 08/25/2021 FINAL APPROVED DCUSHING
Note: contractor addressed issues - ok for final
ROOF IN PROGRESS- MIDROOF 07/27/2021 Disapproved - NO FEE WMILLER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION no one here for unspection (destructive inspection needed, passed midroof inspection without inspection as required 7-23-21... cancelled (raining) 7-27-21... DESTRUCTIVE INSPECTION PERFORMED missing manufacturers overlap on underlayment...missing second layer, Per FBC, section R905.1.1.1 remove all roof coverings and underlayment reapply underlayment and drip edge and call fir midroof with no more than 20 % OF SHINGLES APPLIED AND HAVE ALL DOCUMENTS ON SITE FOR INSPECTION (summit 60 was used and requires a 2 inch overlap)
ROOF IN PROGRESS- MIDROOF 07/23/2021 CANCELLED BY APPLICANT WMILLER
Note: THIS IS A REINSPECTION no one here for unspection (destructive inspection needed, passed midroof inspection without inspection as required 7-23-21... cancelled (raining)
ROOF AFFIDAVIT 07/21/2021 APPROVED MDEFREITAS
ROOF IN PROGRESS- MIDROOF 07/21/2021 Disapproved - NO FEE WMILLER
Note: no one here for unspection (destructive inspection needed, passed midroof inspection without inspection as required

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 07/13/2021
BUILDING DISCOUNT 100% (¤60.00) 07/13/2021
INSPECTION 40 ¤40.00 07/13/2021
SURCHARGE FS 533.721 ¤2.00 07/13/2021
SURCHARGE - FS 468.631 ¤2.00 07/13/2021
Fees Total Due: ¤0.00 Total Paid: ¤4.00