Permit #2021071554
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-00730-0070 |
| CONDITIONED SPACE: 1508 sqft |
| CONDITIONED SPACE: 1381 sqft |
| GARAGE: 487 sqft |
| GARAGE: 505 sqft |
| OPENED PORCH (WITH ROOF) : 170 sqft |
| OPENED PORCH (WITH ROOF) : 170 sqft |
| OPENED PORCH (WITH ROOF) : 56 sqft |
| OPENED PORCH (WITH ROOF) : 53 sqft |
| Total Square Footage: 4330 sqft |
| Block: 00730 |
| Subdivision: 2176 - SECTION 37-LAKEVIEW |
| Job Phone: 386-585-2654 |
| Location Address: 2 LINDSAY DR |
| Type: DU - DUPLEX |
| Issue Date: 12/17/2021 |
| NOC: RECORDED |
| Applicant name: DESIDERIO CARLOS CARREIRO |
| Owner: SOARES CARLOS |
|
Address 25 GRANT STREET NEW BEDFORD, MA 02740 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤200,000.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
RED LINE CONSTRUCTION CO
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6 COMMERCIAL CT PALM COAST, FL 32137 |
CGC1527392 (Exp: 08/31/2026) | 386-585-2654 |
Sub Contractors
CHARLES K DAVIS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3000 E MOODY BLVD BLDG 2 BUNNELL , FL 32110 |
EC13004270 (Exp: 08/31/2026) | 386-931-6614 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
DESIDERIO CARLOS CARREIRO
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6 COMMERCIAL CT PALM COAST, FL 32137 |
CGC1527392 (Exp: 08/31/2026) | 386-585-2654 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/20/2022 | FINAL APPROVED | KSANDOE |
| Note: 12/19/2022 - PREVIOUS INSPECTION NOTES 12/16/2022 - PREVIOUS INSPECTION NOTES 1. Kitchen rangehood exhaust must have smooth interior surface and air tight with backdraft damper and shall be metal or copper M1503.1or 2 2. SMOKE DETECTORS NEED TO BE INTERCONNECTED FBC R314.5 3. Revision needed for energy calcs (model numbers not matching approved energy calcs 12-19-22 cancelled per contractor | |||
| BLD - BUILDING FINAL | 12/19/2022 | CANCELLED BY APPLICANT | LMILLER |
| Note: 12/16/2022 - PREVIOUS INSPECTION NOTES 1. Kitchen rangehood exhaust must have smooth interior surface and air tight with backdraft damper and shall be metal or copper M1503.1or 2 2. SMOKE DETECTORS NEED TO BE INTERCONNECTED FBC R314.5 3. Revision needed for energy calcs (model numbers not matching approved energy calcs 12-19-22 cancelled per contractor | |||
| BLD - BUILDING FINAL | 12/16/2022 | Disapproved -FEE REQUIRED | LMILLER |
| Note: 1. Kitchen rangehood exhaust must have smooth interior surface and air tight with backdraft damper and shall be metal or copper M1503.1or 2 2. SMOKE DETECTORS NEED TO BE INTERCONNECTED FBC R314.5 3. Revision needed for energy calcs (model numbers not matching approved energy calcs | |||
| U -UTILITY RESIDENTIAL FINAL | 12/16/2022 | FINAL APPROVED | DHANEY |
| ROW - FINAL INSPECTION | 12/15/2022 | FINAL APPROVED | PFLANAGAN |
| Note: 12/9/2022 - PREVIOUS INSPECTION NOTES ** 12/09/22 BUILDER NEEDS TO SUBMIT AND UPLOAD THE FINAL SURVEY FOR APPROVAL BEFORE THE FINAL ROW CAN BE COMPLETED | |||
| ROW - FINAL APRON (AFTER POUR) | 12/15/2022 | APPROVED | PFLANAGAN |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/13/2022 | FINAL APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/13/2022 | APPROVED | EMADISON |
| ROW - FINAL INSPECTION | 12/09/2022 | CANCELLED BY APPLICANT | WEB |
| ROW - FINAL INSPECTION | 12/09/2022 | Disapproved - NO FEE | EMADISON |
| Note: ** 12/09/22 BUILDER NEEDS TO SUBMIT AND UPLOAD THE FINAL SURVEY FOR APPROVAL BEFORE THE FINAL ROW CAN BE COMPLETED | |||
| ELECTRIC - EARLY POWER | 11/23/2022 | APPROVED - AS NOTED | KSANDOE |
| Note: Emailed FPL @ 1207. Release Power | |||
| ROW- PRE-APRON (PRE-POUR) | 11/02/2022 | APPROVED | EMADISON |
| Note: ** 11/02/22 MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** IN THE EVENT OF RAIN RECHECK ELEVATIONS AND COMPACTION .. | |||
| U-CROSS CONNECTION | 10/12/2022 | APPROVED - AS NOTED | DHANEY |
| Note: Yard/IRR. not installed yet - No Cross CN. . | |||
| U - SEWER TIE IN | 10/12/2022 | APPROVED | MKRASKI |
| GRAVITY SEWER TEST | 10/12/2022 | APPROVED | MKRASKI |
| PEP TANK INSTALLATION REQUEST | 08/09/2022 | APPROVED | CSTONE |
| INSULATION | 08/09/2022 | APPROVED | RMARTIN |
| LATH/BRICK/ WATER BARRIER | 08/04/2022 | APPROVED | FWILLIS |
| ALL ROUGH | 08/04/2022 | APPROVED | MKRASKI |
| FIREWALL FINAL | 07/18/2022 | APPROVED | FWILLIS |
| FIREWALL DRYWALL NAILING | 07/15/2022 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/13/2022 | APPROVED | FWILLIS |
| Note: New inspection due to canceled inspection THIS IS A REINSPECTION Plans are Ripped and dirty. Please provide a decent set of plans for reviewing. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/12/2022 | CANCELLED BY APPLICANT | WEB |
| Note: THIS IS A REINSPECTION Plans are Ripped and dirty. Please provide a decent set of plans for reviewing. | |||
| ROOF VALLEY & METAL | 07/08/2022 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/08/2022 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/08/2022 | Disapproved - NO FEE | FWILLIS |
| Note: Plans are Ripped and dirty. Please provide a decent set of plans for reviewing. | |||
| TIE BEAM / LINTEL | 06/09/2022 | APPROVED | FWILLIS |
| TIE BEAM / LINTEL | 06/08/2022 | CANCELLED BY APPLICANT | WEB |
| FOUND SURVEY APPROVED (OFFICE) | 05/11/2022 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 04/13/2022 | APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL (need the APPROVED AHRI on site at time of final) (SAME FOR 6TH EDITION) NEED PROOF OF COMPACTION. | |||
| MONOLITHIC SLAB | 04/12/2022 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL (need the APPROVED AHRI on site at time of final) (SAME FOR 6TH EDITION) NEED PROOF OF COMPACTION. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/01/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 04/01/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | HOLD | 12/19/2022 | 12/19/2022 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM placed on hold per contractors request (was submitted without srgnature per contractor, he asked for it to be placed on hold so he coulf submit the correct documents) | |||
| MECH | COMPLETE | 12/19/2022 | 12/19/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/10/2022 | 05/11/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/10/2022 | 05/10/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM no zoning changes | |||
| BLD | HOLD | 12/17/2021 | 12/17/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/17/2021 | 12/17/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Review Comments: Repeat Comments 1.Product Approval Specification Sheet: a. Exterior Wall Soffits product approval number (FL#23352) is invalid; provide approved product, product description, manufacturer, and product approval number. b. Mullion product approval number (FL17676) is for a MI 3540 single hung window. Provide a correct product approval for the proposed mullions. | |||
| BLD | COMPLETE | 12/17/2021 | 12/17/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/02/2021 | 12/02/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/02/2021 | 12/17/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Review Comments: Repeat Comments 1.Product Approval Specification Sheet: a. Exterior Wall Soffits product approval number (FL#23352) is invalid; provide approved product, product description, manufacturer, and product approval number. b. Mullion product approval number (FL17676) is for a MI 3540 single hung window. Provide a correct product approval for the proposed mullions. | |||
| BLD | HOLD | 07/30/2021 | 08/10/2021 |
| Note: Held By: JPI 1. Product Approval Specification Sheet: a. Exterior Swinging Door product approval number (FL#15225.3) is invalid; provide approved product, product description, manufacturer, and product approval number. b. Properly identify Exterior Sectional/Roll Up Doors used on the project with the specific Florida Product Approval Number (i.e. 17671.#-R2); there are thirty-seven (37) types under the number you have provided. c. Exterior Wall Soffits product approval number (FL#15964.8) is invalid; provide approved product, product description, manufacturer, and product approval number. d. Off Ridge Vent omitted; provide approved product, product description& type, manufacturer, and product approval number. 2. Identify/Specify wall construction between Garage and Interior of the home- FBC-R302.6. 3. Identify/Specify fire rating of door from garage to interior of the home- FBC-R302.5.1. 4. Provide interior non load bearing wall detail- FBC 1607.14. 5. Provide Roof Framing Plan (omitted from drawings) that includes but not limited to member identifiers, dimensions, spacing, schedule, and diagrams of trusses identified on the plan- FBC 107.3.5. 6. Provide roof pressure zone nailing schedule- FBC-R301.2(7). 7. Framing illustrated in firewall section does NOT match the U.L. Design #U337 assembly specified on the drawings; provide details and cut sheets for ALL U.L. Rated Assemblies utilized on this project. 8. Specify on drawings that penetrations through rated assemblies must be per FBC R302.4.1.1 and R302.4.1.2. | |||
| CUSVC | COMPLETE | 07/30/2021 | 08/05/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 07/30/2021 | 08/02/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/30/2021 | 07/30/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 07/30/2021 | 08/04/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/30/2021 | 08/03/2021 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/30/2021 | 08/05/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 07/30/2021 | 08/03/2021 |
| Note: Held By: ESTELLE LENS - (386)986-3751 - Landscape plan is missing. Please upload for review/comment. Need to show the A/C pads on the site plan | |||
| SWALE | COMPLETE | 07/30/2021 | 11/03/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 12/20/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/17/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/14/2022 |
| METER - DEPOSIT | ¤120.00 | 12/17/2021 |
| WATER- TURN ON | ¤50.00 | 12/17/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤20.00 | 12/17/2021 |
| INSPECTION- ELECTRICAL | ¤288.00 | 12/17/2021 |
| INSPECTION - MECHANICAL | ¤288.00 | 12/17/2021 |
| INSPECTION - PLUMBING | ¤288.00 | 12/17/2021 |
| PLAN REVIEW - RESIDENTIAL | ¤152.00 | 12/17/2021 |
| CONNECTION FEES | ¤2,035.66 | 12/17/2021 |
| BUILDING DISCOUNT 100% | (¤1,796.00) | 12/17/2021 |
| IMPACT FEE FIRE | ¤734.00 | 12/17/2021 |
| IMPACT FEE PARKS | ¤2,398.24 | 12/17/2021 |
| IMPACT FEE SCHOOL | ¤7,200.00 | 12/17/2021 |
| IMPACT FEE TRANSPORTATION | ¤2,666.00 | 12/17/2021 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 12/17/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤760.00 | 12/17/2021 |
| SITE PLAN 20 | ¤20.00 | 12/17/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 12/17/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 12/17/2021 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/17/2021 |
| SEWER CREDIT | (¤850.00) | 12/17/2021 |
| SEWER INSPECTION | ¤25.00 | 12/17/2021 |
| SEWER CAPITAL FACILITY | ¤9,329.10 | 12/17/2021 |
| WATER CAPITAL FACILITY FEE | ¤6,848.90 | 12/17/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤30,823.40 |