Permit #2021080528
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7058-00280-0160 |
| CONDITIONED SPACE: 2065 sqft |
| GARAGE: 420 sqft |
| OPENED PORCH (WITH ROOF) : 248 sqft |
| OPENED PORCH (WITH ROOF) : 48 sqft |
| Total Square Footage: 2781 sqft |
| Block: 00280 |
| Subdivision: 2215 - SECTION 58-SEMINOLE PARK |
| Job Phone: (386) 547-0409 |
| Location Address: 13 SERENADE PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/02/2021 |
| NOC: Unknown |
| Applicant name: BOHDAN HAWRYLUK |
| Owner: INTERCOASTAL CONSTRUCTION |
|
Address 33 SENECA PATH PALM COAST, FL 32164 |
| Lot: 0160 |
| Contracted Stated Job Value: ¤100,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INTERCOASTAL CONSTRUCTION CO.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
14 SLIPPER ORCHID TRAIL EAST PALM COAST, FL 32164 |
CBC035048 (Exp: 08/31/2024) | (386) 547-0409 | 386-673-8868 |
Sub Contractors
GREGORY ALLEN HENRY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1332 SUNSET BLVD DAYTONA BEACH, FL 32117 |
EC13009193 (Exp: 08/31/2026) | 386-679-6908 |
DENNIS EDWARD CLARKE
| Status | Location Address | State License Number | Phone |
| CANCEL |
453 PALM AVE ORMOND BEACH, FL 32174 |
CAC058147 (Exp: 08/31/2024) | 386-677-1040 |
BOHDAN HAWRYLUK
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
14 SLIPPER ORCHID TRAIL EAST PALM COAST, FL 32164 |
CBC035048 (Exp: 08/31/2024) | (386) 547-0409 | 386-673-8868 |
JOHN ROBERT LONGFRITZ
| Status | Location Address | State License Number | Phone |
| CANCEL |
1323 10TH ST HOLLY HILL, FL 32117 |
CFC057901 (Exp: 08/31/2022) | 386-258-7316 |
Inspection History
| Type | Request Date | Result | Inspector |
| MONOLITHIC SLAB | 03/30/2022 | APPROVED | DCUSHING |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Edges caved in everywhere Column pad steel covered with dirt, multipe 03/28/2022: Missing dowel right side of garage Missing ground wire Missing island electrical chase all items addressed | |||
| MONOLITHIC SLAB | 03/28/2022 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Edges caved in everywhere Column pad steel covered with dirt, multipe 03/28/2022: Missing dowel right side of garage Missing ground wire Missing island electrical chase | |||
| MONOLITHIC SLAB | 03/21/2022 | Disapproved - NO FEE | DCUSHING |
| Note: Edges caved in everywhere Column pad steel covered with dirt, multipe | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 03/16/2022 | CANCELLED BY INSPECTOR | MGIBSON |
| Note: WRONG INSPECTION CALLED IN | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 03/04/2022 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS IS A REINSPECTION PLANS DO NOT INDICATE L/T AND WATER PIPES GOING THROUGH FOOTERS IN MULTIPLE PLACES NEED SLEEVED WITH 2X THE DIAMETER OF PIPE PASSING THROUGH EXP..3/4'' NEEDS 1 1/2'' 1/2'' NEEDS 1'' MEET WITH PLUMBING CONTRACTOR ALL WAS TAKEN CARE OF | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/15/2022 | CANCELLED BY APPLICANT | AWS_IVR |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/15/2022 | Disapproved - NO FEE | MGIBSON |
| Note: PLANS DO NOT INDICATE L/T AND WATER PIPES GOING THROUGH FOOTERS IN MULTIPLE PLACES NEED SLEEVED WITH 2X THE DIAMETER OF PIPE PASSING THROUGH EXP..3/4'' NEEDS 1 1/2'' 1/2'' NEEDS 1'' | |||
| WATER METER INSTALLATION REQUEST | 02/14/2022 | APPROVED | CSTONE |
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| U - SEWER TIE IN | |||
| ROW - STORMWATER FINAL | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| FOUND SURVEY APPROVED (OFFICE) | |||
| FINAL SURVEY (OFFICE USE ONLY) | |||
| GRAVITY SEWER TEST | |||
| ELECTRIC - EARLY POWER | |||
| LATH/BRICK/ WATER BARRIER | |||
| TIE BEAM / LINTEL | |||
| ALL ROUGH | |||
| WALL SHEATHING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| ROOF VALLEY & METAL | |||
| INSULATION | |||
| BLD - BUILDING FINAL |
Review History
| Department | Status | Date In | Date Out |
| PLUM | COMPLETE | 02/25/2022 | 02/25/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/24/2022 | 02/25/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 02/24/2022 | 02/25/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Per the inspector comments dated 2/15/2022, plans do not indicate size and multiple locations of the propose sleeve. Plans call-out a 6 inch sleeve in one location. A revision to the plans required to reflect the multiple locations and sizes of the proposed sleeves. | |||
| PLUM | HOLD | 02/18/2022 | 02/22/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Plans submitted were altered. Plans altered by someone other than the Engineer of record are not accepted and in violation of F.S. 568. 2. Per the inspector comments dated 2/15/2022, plans do not indicate size and multiple locations of the propose sleeve. Plans call-out a 6 inch sleeve in one location. A revision to the plans required to reflect the multiple locations and sizes of the proposed sleeves. | |||
| BLD | HOLD | 02/18/2022 | 02/22/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Plans submitted were altered. Plans altered by someone other than the Engineer of record are not accepted and in violation of F.S. 568. 2. Per the inspector comments dated 2/15/2022, plans do not indicate size and multiple locations of the propose sleeve. Plans call-out a 6 inch sleeve in one location. A revision to the plans required to reflect the multiple locations and sizes of the proposed sleeves. | |||
| MECH | COMPLETE | 08/25/2021 | 08/25/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/25/2021 | 08/26/2021 |
| Note: Released By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 08/25/2021 | 08/26/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/20/2021 | 08/20/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/20/2021 | 08/23/2021 |
| Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS 1. Revised plans where alternated and resubmitted. Per the architects copyright and State of Florida laws, plans are required to be revised and resubmitted. | |||
| MECH | HOLD | 08/20/2021 | 08/23/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition- Chosen equipment on Manual J/S exceeds the maximum of 1.15 times the load calculated. (Second Request) | |||
| ELEC | HOLD | 08/20/2021 | 08/23/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Can not write on sealed plans | |||
| ZON | COMPLETE | 08/20/2021 | 08/20/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/20/2021 | 08/24/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 08/20/2021 | 12/01/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/12/2021 | 08/12/2021 |
| Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS: 1. Per 302.6 2020 FBCR, 20 min rated door is required. Plans shows a 2868 but a callout for 6068 slider is noted per the door schedule. A revision is required to reflect the requirements of the Code section mentioned above. 2. Product Approval for the proposed roof underlayment is not correct. Please revise and resubmit. | |||
| CUSVC | COMPLETE | 08/12/2021 | 08/19/2021 |
| Note: Released By: ALYSSA ROSCOE - - | |||
| ELEC | HOLD | 08/12/2021 | 08/13/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need outlet on the front of the house. NEC 2017 210.52 (E) (1) Outlets in garage need to be GFCI protected NEC 2017 210.8 | |||
| ENGIN1 | HOLD | 08/12/2021 | 08/12/2021 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM No Survey or Site Plan in submittal | |||
| LOCATE | COMPLETE | 08/12/2021 | 08/16/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/12/2021 | 08/13/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition- Chosen equipment on Manual J/S exceeds the maximum of 1.15 times the load calculated. 2. Duct Layout needs to be signed by AC contractor | |||
| SW1 | HOLD | 08/12/2021 | 08/19/2021 |
| Note: Held By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM no site plan uploaded for review | |||
| ZON | HOLD | 08/12/2021 | 08/13/2021 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Please submit a Site Plan Landscape plan needs: Residential homes shall provide a foundation plantings consisting of 16 shrubs on interior lots. Eight shrubs shall be planted in front of home and four shrubs planted on each side of the home. The corners of the home shall be wrapped with shrubbery or have an understory tree planted there. Please include the proposed shrubs that will provide coverage for the mechanical equipment. also provide what type of grass will be used at this site and if it will require an irrigation system. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| METER - DEPOSIT | ¤60.00 | 09/02/2021 |
| WATER- TURN ON | ¤25.00 | 09/02/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/02/2021 |
| INSPECTION - RESIDENTIAL | ¤709.50 | 09/02/2021 |
| PLAN REVIEW - RESIDENTIAL | ¤201.24 | 09/02/2021 |
| CONNECTION FEES | ¤1,017.83 | 09/02/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 09/02/2021 |
| IMPACT FEE FIRE | ¤367.00 | 09/02/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 09/02/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 09/02/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 09/02/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/02/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 09/02/2021 |
| SURCHARGE FS 533.721 | ¤9.96 | 09/02/2021 |
| SURCHARGE - FS 468.631 | ¤14.94 | 09/02/2021 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/02/2021 |
| SW ENG INSPECTION 60 | ¤60.00 | 09/02/2021 |
| SW ENG PRE APRON | ¤30.00 | 09/02/2021 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/02/2021 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/02/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 09/02/2021 |
| SEWER CREDIT | (¤1,700.00) | 09/02/2021 |
| SEWER INSPECTION | ¤25.00 | 09/02/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 09/02/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 09/02/2021 |
| SITE PLAN 30 | ¤30.00 | 09/02/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,653.07 |