I want to search for...
Permit #2021080719
Permit Details
Status: COED
| Parcel Id: 07-11-31-7030-00040-0100 |
| CONDITIONED SPACE: 1926 sqft |
| GARAGE: 769 sqft |
| OPENED PORCH (WITH ROOF) : 267 sqft |
| OPENED PORCH (WITH ROOF) : 42 sqft |
| Total Square Footage: 3004 sqft |
| Block: 00040 |
| Subdivision: 2154 - SECTION 30-ROYAL PALMS |
| Job Phone: 386-447-4151 |
| Location Address: 1 RAEMOND LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/20/2021 |
| NOC: RECORDED |
| Applicant name: GENE WARREN SLONE |
| Owner: KALMANOVSKY, ANATOLY |
|
Address 950 DUNHAM LN BUFFALO GROVE, IL 60089 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY HOME |
| Type: CN |
Contractor
FLORIDA GREEN CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone |
| INACTIVE |
870 E RETTA STREET DELEON SPRINGS, FL 32130 |
CBC1260957 (Exp: 08/31/2026) | 407-580-2657 |
Sub Contractors
GREGG A MCANALLY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE PALM COAST, FL 32092 |
CAC1815760 (Exp: 08/31/2022) | 904-829-8898 |
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
ERIC FRANCO
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
840 DELTONA BLVD DELTONA, FL 32725 |
STE F2 DELTONA, FL 32725 |
CCC1327280 (Exp: 08/31/2026) | 386-575-4007 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/20/2023 | FINAL APPROVED | JWALKER |
| Note: 1/18/2023 - PREVIOUS INSPECTION NOTES 1. Laundry room outlets need to be GFI protected. 2. Exterior outlets are to be of the water resistant type and GFI protected. Check all 3. Pep tank is being moved. From rear of home to conduit with 12-2 wire capped off at side wall next to garage. 4. Smoke detector in the left side hallway is to have 4" minimum clearance from the wall. 5. Outdoor heat pump calls for max breaker of 35 amp 60 amp installed. The Mini split calls for a 15amp max. 6. Dishwasher / Garbage disposal outlet cannot be mounted in the face up position in the sink cabinet. 406.5 NEC. | |||
| U -UTILITY RESIDENTIAL FINAL | 01/20/2023 | FINAL APPROVED | LFITZGERALD |
| Note: 1/17/2023 - PREVIOUS INSPECTION NOTES pep panel required to be installed on front corner of house -3feet in by 3feet high from proposed grade-on same side as pep tank/ALSO check pep panel has power-my utility deipt. informed to relocate panel and rewire | |||
| BLD - BUILDING FINAL | 01/18/2023 | Disapproved - NO FEE | JWALKER |
| Note: 1. Laundry room outlets need to be GFI protected. 2. Exterior outlets are to be of the water resistant type and GFI protected. Check all 3. Pep tank is being moved. From rear of home to conduit with 12-2 wire capped off at side wall next to garage. 4. Smoke detector in the left side hallway is to have 4" minimum clearance from the wall. 5. Outdoor heat pump calls for max breaker of 35 amp 60 amp installed. The Mini split calls for a 15amp max. 6. Dishwasher / Garbage disposal outlet cannot be mounted in the face up position in the sink cabinet. 406.5 NEC. | |||
| U-CROSS CONNECTION | 01/17/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: has potable irrigation with PVB installed-no cross connection | |||
| U -UTILITY RESIDENTIAL FINAL | 01/17/2023 | Disapproved - NO FEE | LFITZGERALD |
| Note: pep panel required to be installed on front corner of house -3feet in by 3feet high from proposed grade-on same side as pep tank/ALSO check pep panel has power-my utility deipt. informed to relocate panel and rewire | |||
| ROW - STORMWATER FINAL | 01/13/2023 | APPROVED - AS NOTED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD | |||
| ROW - FINAL APRON (AFTER POUR) | 01/13/2023 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/03/2023 | APPROVED | PFLANAGAN |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/03/2023 | APPROVED | PFLANAGAN |
| ELECTRIC - EARLY POWER | 12/08/2022 | APPROVED | JWALKER |
| ROW- PRE-APRON (PRE-POUR) | 12/06/2022 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| ELECTRIC-TUG | 11/18/2022 | APPROVED | RMARTIN |
| GRAVITY SEWER TEST | 10/27/2022 | APPROVED | MGIBSON |
| U - SEWER TIE IN | 10/27/2022 | APPROVED | MGIBSON |
| PEP TANK INSTALLATION REQUEST | 10/13/2022 | APPROVED | CSTONE |
| INSULATION | 09/26/2022 | APPROVED | JWALKER |
| Note: 9/16/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 Protect the ground wire at the meter. The windows installed are Viwinco windows fl approval # 29511.1 The approval worksheet calls for MI windows Fl # 21638 please submitt a revision to the building department for the change of material. Check above listed at insulation inspectoin 9/16/22 Listed item above has not been corrected. | |||
| LATH/BRICK/ WATER BARRIER | 09/21/2022 | APPROVED | JWALKER |
| INSULATION | 09/16/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: Inspector Notes from Inspection 2420 Protect the ground wire at the meter. The windows installed are Viwinco windows fl approval # 29511.1 The approval worksheet calls for MI windows Fl # 21638 please submitt a revision to the building department for the change of material. Check above listed at insulation inspectoin 9/16/22 Listed item above has not been corrected. | |||
| ALL ROUGH | 09/01/2022 | APPROVED - AS NOTED | JWALKER |
| Note: Protect the ground wire at the meter. The windows installed are Viwinco windows fl approval # 29511.1 The approval worksheet calls for MI windows Fl # 21638 please submitt a revision to the building department for the change of material. Check above listed at insulation inspectoin | |||
| ALL ROUGH | 08/29/2022 | Disapproved - NO FEE | JWALKER |
| Note: Install nail plate at dryer duct. The 14-2 wire running at the 2x4 wall in between the two rear doors has been cut. remove and replace Missing 5' head test. Front door missing fasteners right side jamb. Protect the ground wire at the meter. The windows installed are Viwinco windows fl approval # 29511.1 The approval worksheet calls for MI windows Fl # 21638 please submitt a revision to the building department for the change of material. Contractor may procede with spray foaming the roof decking. | |||
| WALL SHEATHING | 04/25/2022 | APPROVED | JWALKER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/18/2022 | APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION Truss 28, 15, 7, 3, Missing hold down anchors. Marked the drawings. Please remove the plywood at the front entry concealing the post hold down anchors and the 2x12 beam returns. Please provide a detail for the bolting used to connect the beams to the IFC wall. Truss page of the approve drawing Page 10 needs to be onsite for reinspection. Roof decking passed inspection Engineering on trusses passed inspection. | |||
| ROOF VALLEY & METAL | 03/29/2022 | APPROVED | JWALKER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/21/2022 | Disapproved - NO FEE | JWALKER |
| Note: Truss 28, 15, 7, 3, Missing hold down anchors. Marked the drawings. Please remove the plywood at the front entry concealing the post hold down anchors and the 2x12 beam returns. Please provide a detail for the bolting used to connect the beams to the IFC wall. Truss page of the approve drawing Page 10 needs to be onsite for reinspection. Roof decking passed inspection Engineering on trusses passed inspection. | |||
| TIE BEAM / LINTEL | 02/02/2022 | APPROVED | JWALKER |
| FOUND SURVEY APPROVED (OFFICE) | 12/16/2021 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 12/07/2021 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION The 2" PVC drain line running through the footing in 2 areas at the rear of the garage center area. The pipe needs to be sleeved or a install releving arches. | |||
| MONOLITHIC SLAB | 12/06/2021 | Disapproved - NO FEE | JWALKER |
| Note: The 2" PVC drain line running through the footing in 2 areas at the rear of the garage center area. The pipe needs to be sleeved or a install releving arches. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/17/2021 | APPROVED | MGIBSON |
| ELECTRIC TEMP POLE | 10/13/2021 | APPROVED - AS NOTED | JWALKER |
| Note: Email FPL | |||
| WATER METER INSTALLATION REQUEST | 10/13/2021 | APPROVED | CSTONE |
| Note: THIS IS A REINSPECTION ADDED ON 10/12/2021 9:19:27 AM lot not clear | |||
| WATER METER INSTALLATION REQUEST | 10/06/2021 | Disapproved - NO FEE | CSTONE |
| Note: lot not clear |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 01/12/2023 | 01/12/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/20/2022 | 10/20/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/21/2022 | 09/23/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 09/20/2022 | 09/20/2022 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM We do not require the product approval sheets to be submitted, we do require the product approval worksheet with the numbers to be submitted. | |||
| BLD | COMPLETE | 04/07/2022 | 04/08/2022 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/16/2021 | 12/16/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/16/2021 | 12/16/2021 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/21/2021 | 09/21/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/21/2021 | 09/28/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/21/2021 | 09/21/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/31/2021 | 08/31/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/31/2021 | 08/31/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 08/31/2021 | 09/03/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| BLD | COMPLETE | 08/31/2021 | 08/31/2021 |
| Note: Released By: JPI | |||
| SWALE | COMPLETE | 08/13/2021 | 11/09/2021 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/12/2021 | 08/18/2021 |
| Note: Held By: JPI 1. Product Approval Specification Sheet: a. Architectural Brackets (elevations) omitted; provide product description& type, manufacturer, and product approval number. b. Exterior Sectional/Roll Up Overhead Garage Door product approval number provided is for a door which is “9’-2” to 16’-0” wide. The drawings specify an 8’-0” wide door; provide approved product, product description, manufacturer, and product approval number. c. Exterior Wall Soffit product approval number is invalid; provide approved product, product description, manufacturer, and product approval number. d. Roofing Asphalt Shingles product approval number is invalid; provide approved product, product description, manufacturer, and product approval number. e. Roofing Single Ply Roof Exterior Sheathing product approval number is invalid; provide approved product, product description, manufacturer, and product approval number. | |||
| CUSVC | HOLD | 08/12/2021 | 08/18/2021 |
| Note: Held By: HALEIGH HAND - - Please correct the utility application to have the correct address and parcel number. | |||
| ELEC | COMPLETE | 08/12/2021 | 08/13/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/12/2021 | 08/13/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 08/12/2021 | 08/16/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/12/2021 | 08/16/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Square footage on Energy Calcs and Heatload does not match the house. Revise to match | |||
| SW1 | COMPLETE | 08/12/2021 | 08/19/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/12/2021 | 08/16/2021 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Please provide banding on windows facing the right of wat on left side of the home. Please provide the elevation from farther side of garage to the property line (corner before the A/C pad). |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 01/20/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 01/20/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/20/2023 |
| CONNECTION FEES | ¤1,017.83 | 09/20/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 09/20/2021 |
| IMPACT FEE FIRE | ¤367.00 | 09/20/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 09/20/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 09/20/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 09/20/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/20/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 09/20/2021 |
| SURCHARGE FS 533.721 | ¤9.96 | 09/20/2021 |
| SURCHARGE - FS 468.631 | ¤14.94 | 09/20/2021 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/20/2021 |
| SW ENG INSPECTION 60 | ¤60.00 | 09/20/2021 |
| SW ENG PRE APRON | ¤30.00 | 09/20/2021 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/20/2021 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/20/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 09/20/2021 |
| SEWER CREDIT | (¤1,146.59) | 09/20/2021 |
| SEWER INSPECTION | ¤25.00 | 09/20/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 09/20/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 09/20/2021 |
| SITE PLAN 30 | ¤30.00 | 09/20/2021 |
| METER - DEPOSIT | ¤60.00 | 09/20/2021 |
| WATER- TURN ON | ¤25.00 | 09/20/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/20/2021 |
| INSPECTION - RESIDENTIAL | ¤709.50 | 09/20/2021 |
| PLAN REVIEW - RESIDENTIAL | ¤201.24 | 09/20/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤16,311.48 |