Permit #2021080874
Permit Details
Status: COED
| Parcel Id: 07-11-31-7017-00040-0290 |
| CONDITIONED SPACE: 2086 sqft |
| GARAGE: 867 sqft |
| OPENED PORCH (WITH ROOF) : 371 sqft |
| OPENED PORCH (WITH ROOF) : 60 sqft |
| Total Square Footage: 3384 sqft |
| Block: 00040 |
| Subdivision: 2129 - SECTION 17-BELLE TERRE |
| Job Phone: 386-237-5837 |
| Location Address: 51 BOLLING LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/12/2021 |
| NOC: RECORDED |
| Applicant name: MARSEL GILMANSHIN |
| Owner: WROBEL BOGDAN |
|
Address 161 MILTON AVE NUTLEY, NJ 07110 |
| Lot: 0290 |
| Contracted Stated Job Value: ¤295,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
GILMANS DEVELOPMENT CORP
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
Sub Contractors
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
MAREK HENRYK SCHECHINGER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
28 SEBASTIAN AVENUE ST. AUGUSTINE, FL 32084 |
CAC058520 (Exp: 08/31/2026) | (904)829-2345 | (904)810-4926 |
BANY RAFAEL MELENDEZ
| Status | Location Address | State License Number | Phone |
| INACTIVE |
2212 S CHICKASAW TRL #112 ORLANDO, FL 0 |
CCC1331793 (Exp: 08/31/2026) | 407-694-9836 |
SCOTT H STILLWELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4500 US 1 UNIT 206 BUNNELL, FL 32110 |
CAC1819433 (Exp: 08/31/2026) | 386-864-4404 |
MAREK DYBACKI
| Status | Location Address | State License Number | Phone |
| INACTIVE |
4702 PERCEPTION CIRCLE , 0 |
ER13016191 (Exp: 08/31/2024) | 413-695-4060 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 11/21/2023 | FINAL APPROVED | DHANEY |
| Note: 10/25/2023 - PREVIOUS INSPECTION NOTES 10/23/2023 - PREVIOUS INSPECTION NOTES Could not find sewer clean out in yard . Still do not see sewer clean out in yard . 10/25 . | |||
| BLD - BUILDING FINAL | 11/20/2023 | FINAL APPROVED | JSTEWART |
| Note: 10/26/2023 - PREVIOUS INSPECTION NOTES 10/26/23- Previous note # 5 not rectified.... Need to post Insulation cert..R303.1.1.2 INSTALLER SHALL SIGN DATE AND POST CERTIFICATE IN A CONSPICUOUS LOCATION Submitted energy calcs was Rejected by the building dept, please call the building dept to fix for aproval. 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23- 1. Please obtain a revision on energy calcs for equipment installed. 2. Please install landscaping (mulch bed) at ODU liquid lines and condensation drain. 3. Please install permanent Hose bibb anti siphon vaccum breakers....P2902.4 Protection of potable water outlets 4. install face plates on both attic Lights switches. 5. Need to post Insulation cert..R303.1.1.2 INSTALLER SHALL SIGN DATE AND POST CERTIFICATE IN A CONSPICUOUS LOCATION 5. Please install Laundry water supply box cover or seal perimeter. 6. Please seal all ceiling penetrations in garage x 2. | |||
| BLD - BUILDING FINAL | 10/26/2023 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 10/26/23- Previous note # 5 not rectified.... Need to post Insulation cert..R303.1.1.2 INSTALLER SHALL SIGN DATE AND POST CERTIFICATE IN A CONSPICUOUS LOCATION Submitted energy calcs was Rejected by the building dept, please call the building dept to fix for aproval. 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23- 1. Please obtain a revision on energy calcs for equipment installed. 2. Please install landscaping (mulch bed) at ODU liquid lines and condensation drain. 3. Please install permanent Hose bibb anti siphon vaccum breakers....P2902.4 Protection of potable water outlets 4. install face plates on both attic Lights switches. 5. Need to post Insulation cert..R303.1.1.2 INSTALLER SHALL SIGN DATE AND POST CERTIFICATE IN A CONSPICUOUS LOCATION 5. Please install Laundry water supply box cover or seal perimeter. 6. Please seal all ceiling penetrations in garage x 2. | |||
| U -UTILITY RESIDENTIAL FINAL | 10/25/2023 | Disapproved -FEE REQUIRED | DHANEY |
| Note: 10/23/2023 - PREVIOUS INSPECTION NOTES Could not find sewer clean out in yard . Still do not see sewer clean out in yard . 10/25 . | |||
| ROW - STORMWATER FINAL | 10/25/2023 | APPROVED | RGROSS |
| Note: 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23 SPOKE TO CM. STILL NEED TO CLEAN OUT CULVERT PIPE ENDS AND REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT LOT ON LEFT. _______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 ** 05/23/23 BUILDER NEEDS TO REPAIR RIGHT SIDE EDGE OF DRIVEWAY BROKEN CONCRETE ** CLEAN OUT CULVERT OF ALL SEDIMENT AND DEBRIS ** REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ON LEFT SIDE ** SOD SWALE ON LEFT SIDE WHERE PORTA-JOHN WAS AT PROPERTY LINE | |||
| U -UTILITY RESIDENTIAL FINAL | 10/23/2023 | Disapproved - NO FEE | DHANEY |
| Note: Could not find sewer clean out in yard . | |||
| BLD - BUILDING FINAL | 10/23/2023 | Disapproved - NO FEE | JSTEWART |
| Note: 10/23/23- 1. Please obtain a revision on energy calcs for equipment installed. 2. Please install landscaping (mulch bed) at ODU liquid lines and condensation drain. 3. Please install permanent Hose bibb anti siphon vaccum breakers....P2902.4 Protection of potable water outlets 4. install face plates on both attic Lights switches. 5. Need to post Insulation cert..R303.1.1.2 INSTALLER SHALL SIGN DATE AND POST CERTIFICATE IN A CONSPICUOUS LOCATION 5. Please install Laundry water supply box cover or seal perimeter. 6. Please seal all ceiling penetrations in garage x 2. | |||
| ROW - FINAL APRON (AFTER POUR) | 10/23/2023 | APPROVED | FSLADISH |
| Note: PIPE IS GOOD. CUTS MADE. CULVERTS CLEAR OF WATER. HOT PATCH COMPLETED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 ** 05/23/23 BUILDER NEEDS TO REPAIR RIGHT SIDE EDGE OF DRIVEWAY BROKEN CONCRETE ** CLEAN OUT CULVERT OF ALL SEDIMENT AND DEBRIS ** REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ON LEFT SIDE ** SOD SWALE ON LEFT SIDE WHERE PORTA-JOHN WAS AT PROPERTY LINE | |||
| ROW - STORMWATER FINAL | 10/23/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 10/23/23 SPOKE TO CM. STILL NEED TO CLEAN OUT CULVERT PIPE ENDS AND REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT LOT ON LEFT. _______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 ** 05/23/23 BUILDER NEEDS TO REPAIR RIGHT SIDE EDGE OF DRIVEWAY BROKEN CONCRETE ** CLEAN OUT CULVERT OF ALL SEDIMENT AND DEBRIS ** REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ON LEFT SIDE ** SOD SWALE ON LEFT SIDE WHERE PORTA-JOHN WAS AT PROPERTY LINE | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/23/2023 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/23/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 05/23/23 BUILDER NEEDS TO REPAIR RIGHT SIDE EDGE OF DRIVEWAY BROKEN CONCRETE ** CLEAN OUT CULVERT OF ALL SEDIMENT AND DEBRIS ** REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ON LEFT SIDE ** SOD SWALE ON LEFT SIDE WHERE PORTA-JOHN WAS AT PROPERTY LINE | |||
| ELECTRIC - EARLY POWER | 01/13/2023 | APPROVED | JMUNSON |
| Note: 12/19/2022 - PREVIOUS INSPECTION NOTES Everything needs to be safed off in a box Panel cover must be on All outlet and switch plates must be installed | |||
| ROW- PRE-APRON (PRE-POUR) | 01/09/2023 | APPROVED | EMADISON |
| Note: ** 01/09/23 ALL CORRECTIONS HAVE BEEN MADE READY TO POUR ** MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** IN THE EVENT OF RAIN BUILDER NEEDS TO RECHECK CULVERT ELEVATION AND COMPACTION ___________________________________________________________________________________________________________________________ 1/5/2023 - PREVIOUS INSPECTION NOTES 01/5/23=The Culvert t is not 8 ft from the road edge. THE MITER END CENTER NEED TO BE A 8 FT FROM ROAD EDGE NEDD TO SECURE THE CULVERT PIPE 1/2 UP, IN THE ENTIRE AREA TO BE POURED. MATERIAL SHOULD BE COMPACTED AROUND PIPE ABOUT 1/2 WAY UP THE SIDE OF THE PIPE. NEED TO SHAVE THE DRIVEWAY NEED * 4” MINIMUM THICK CONCRETE REQUIRED ABOVE THE R.O.W. * 5" MINIMUM THICK CONCRETE REQUIRED IN THE APRON NEED AFORM BOARD BY THE EDGE OF THE ROAD | |||
| ROW- PRE-APRON (PRE-POUR) | 01/05/2023 | Disapproved - NO FEE | GBERTOLA |
| Note: 01/5/23=The Culvert t is not 8 ft from the road edge. THE MITER END CENTER NEED TO BE A 8 FT FROM ROAD EDGE NEDD TO SECURE THE CULVERT PIPE 1/2 UP, IN THE ENTIRE AREA TO BE POURED. MATERIAL SHOULD BE COMPACTED AROUND PIPE ABOUT 1/2 WAY UP THE SIDE OF THE PIPE. NEED TO SHAVE THE DRIVEWAY NEED * 4” MINIMUM THICK CONCRETE REQUIRED ABOVE THE R.O.W. * 5" MINIMUM THICK CONCRETE REQUIRED IN THE APRON NEED AFORM BOARD BY THE EDGE OF THE ROAD | |||
| U-CROSS CONNECTION | 12/19/2022 | APPROVED - AS NOTED | JHARDING |
| Note: No irrigation, no cross connections. | |||
| U - SEWER TIE IN | 12/19/2022 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS IS A REINSPECTION U-SEWER TIE IN TAP NOT MADE BOTH U-SEWER TIE IN AND GRAVITY SEWER APPROVED | |||
| ELECTRIC - EARLY POWER | 12/19/2022 | Disapproved -FEE REQUIRED | JMUNSON |
| Note: Everything needs to be safed off in a box Panel cover must be on All outlet and switch plates must be installed | |||
| ROW - DRAINAGE | 09/08/2022 | APPROVED | EMADISON |
| Note: THIS IS A REINSPECTION ** 09/08/22 CORRECTIONS MADE THIS IS A REINSPECTION ** SWALE APPEARS TO BE OPENED NEED TO REMOVE PORTA JOHN FROM SWALE AREA AND PUT ONTO JOB SITE. ** FOLLOW UP INSPECTION ON 09/08/22 BUILDER NEEDS TO OPEN DRIANAGE ACROSS THE FRONT SWALE ROW NEED A PIPE ON THE GROUND MINIMUN 12 INCH, SWALE NEED TO BE OPENED, MAINTAINED AT THE END OF EVERY DAY. INSPECTOR BE BACK 9/6/22 | |||
| ROW - DRAINAGE | 09/06/2022 | PARTIALLY APPROVED | EMADISON |
| Note: THIS IS A REINSPECTION ** SWALE APPEARS TO BE OPENED NEED TO REMOVE PORTA JOHN FROM SWALE AREA AND PUT ONTO JOB SITE. ** FOLLOW UP INSPECTION ON 09/08/22 BUILDER NEEDS TO OPEN DRIANAGE ACROSS THE FRONT SWALE ROW NEED A PIPE ON THE GROUND MINIMUN 12 INCH, SWALE NEED TO BE OPENED, MAINTAINED AT THE END OF EVERY DAY. INSPECTOR BE BACK 9/6/22 | |||
| ROW - DRAINAGE | 08/29/2022 | Disapproved - NO FEE | GBERTOLA |
| Note: BUILDER NEEDS TO OPEN DRIANAGE ACROSS THE FRONT SWALE ROW NEED A PIPE ON THE GROUND MINIMUN 12 INCH, SWALE NEED TO BE OPENED, MAINTAINED AT THE END OF EVERY DAY. INSPECTOR BE BACK 9/6/22 | |||
| U - SEWER TIE IN | 07/21/2022 | Disapproved - NO FEE | MGIBSON |
| Note: U-SEWER TIE IN TAP NOT MADE | |||
| GRAVITY SEWER TEST | 07/21/2022 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: GRAVITY SEWER NOT RAN YET, ALSO NOT INSPECTORS RESPONSIBILTY TO SCHEDUAL INSPECTIONS,BOTH GRAVITY SEWER AND USEWER TIE IN TO BE SCHEDULED AT SAME TIME | |||
| LATH/BRICK/ WATER BARRIER | 05/20/2022 | APPROVED | FWILLIS |
| WALL SHEATHING | 05/09/2022 | APPROVED | FWILLIS |
| WINDOW NAILING | 04/29/2022 | APPROVED | FWILLIS |
| INSULATION | 04/08/2022 | APPROVED | FWILLIS |
| ALL ROUGH | 04/05/2022 | APPROVED - AS NOTED | KSANDOE |
| Note: THIS IS A REINSPECTION Window nailing inspection added. 5ft head test failed | |||
| ALL ROUGH | 04/04/2022 | CANCELLED BY APPLICANT | MKRASKI |
| ROOF VALLEY & METAL | 03/07/2022 | APPROVED | KSANDOE |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/22/2022 | APPROVED - AS NOTED | FWILLIS |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION COULD NOT FIND THE DETAILS FOR BUILT UP COLUMN, ANY FASTENERS, NAILING PATTERN AND RODS AT TRUSS T1, MASTERBEDROOM AREA. 2/9/22 - STILL NEED TO SEE THE DETAIL FOR THE WALL SEPARATING THE CRAFT ROOM AND LAUNDRY ROOM. CONNECTORS AND GO BOLTS BEING USED, IS THERE A DETAIL FOR THIS. 2/22/22 - PROVIDE STAMPED COPY OF APPROVED DRAWINGS AT NEXT INSPECTION. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/09/2022 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: THIS IS A REINSPECTION COULD NOT FIND THE DETAILS FOR BUILT UP COLUMN, ANY FASTENERS, NAILING PATTERN AND RODS AT TRUSS T1, MASTERBEDROOM AREA. 2/9/22 - STILL NEED TO SEE THE DETAIL FOR THE WALL SEPARATING THE CRAFT ROOM AND LAUNDRY ROOM. CONNECTORS AND GO BOLTS BEING USED, IS THERE A DETAIL FOR THIS. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/08/2022 | Disapproved - NO FEE | FWILLIS |
| Note: COULD NOT FIND THE DETAILS FOR BUILT UP COLUMN, ANY FASTENERS, NAILING PATTERN AND RODS AT TRUSS T1, MASTERBEDROOM AREA. | |||
| FOUND SURVEY APPROVED (OFFICE) | 02/07/2022 | APPROVED | TDOAK |
| TIE BEAM / LINTEL | 01/06/2022 | APPROVED | FWILLIS |
| MONOLITHIC SLAB | 11/19/2021 | APPROVED | FWILLIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/10/2021 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 11/04/2021 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 11/13/2023 | 11/13/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/25/2023 | 10/25/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition | |||
| BLD | COMPLETE | 02/18/2022 | 02/22/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/07/2022 | 02/07/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/07/2022 | 02/07/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/31/2021 | 09/01/2021 |
| Note: Released By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/31/2021 | 09/01/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/31/2021 | 09/10/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/31/2021 | 09/01/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/31/2021 | 09/01/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 08/17/2021 | 11/10/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/17/2021 | 08/17/2021 |
| Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS: Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 13/8 inches (35 mm) in thickness, solid or honeycombcore steel doors not less than 13/8 inches (35 mm) thick, or 20-minute fire-rated doors. | |||
| CUSVC | COMPLETE | 08/17/2021 | 08/20/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 08/17/2021 | 08/17/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/17/2021 | 08/17/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 08/17/2021 | 08/19/2021 |
| Note: Released By: TONI CHURCHILL - - | |||
| MECH | HOLD | 08/17/2021 | 08/17/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Plans show R30 insulation with attic. Energy calcs say R20 with unvented attic. Revise to match | |||
| SW1 | HOLD | 08/17/2021 | 08/24/2021 |
| Note: Held By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM 12 ft Driveway needs to be eliminated from the plan. Edge of Driveway must be a minimum of 75 ft from the center of the nearest intersection. Sec 300.01C1 | |||
| ZON | COMPLETE | 08/17/2021 | 08/18/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/15/2023 |
| REINSPECTION FEE | ¤40.00 | 11/15/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 11/15/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/20/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 10/20/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/20/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/20/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 10/20/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 10/20/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 10/20/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 10/20/2023 |
| CONTRACTOR CHANGE | ¤40.00 | 10/20/2023 |
| CONTRACTOR CHANGE | ¤40.00 | 10/20/2023 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 09/12/2021 |
| IMPACT FEE FIRE | ¤367.00 | 09/12/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 09/12/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 09/12/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 09/12/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/12/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/12/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 09/12/2021 |
| METER - DEPOSIT | ¤60.00 | 09/12/2021 |
| METER - DEPOSIT | ¤60.00 | 09/12/2021 |
| WATER-METER | ¤441.07 | 09/12/2021 |
| WATER- TURN ON | ¤25.00 | 09/12/2021 |
| WATER- TURN ON | ¤25.00 | 09/12/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/12/2021 |
| INSPECTION - RESIDENTIAL | ¤811.25 | 09/12/2021 |
| PLAN REVIEW - RESIDENTIAL | ¤230.10 | 09/12/2021 |
| SW ENG INSPECTION 60 | ¤60.00 | 09/12/2021 |
| SW ENG PRE APRON | ¤30.00 | 09/12/2021 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/12/2021 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/12/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 09/12/2021 |
| SEWER CREDIT | (¤2,465.75) | 09/12/2021 |
| SEWER INSPECTION | ¤25.00 | 09/12/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 09/12/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 09/12/2021 |
| SITE PLAN 30 | ¤30.00 | 09/12/2021 |
| CONNECTION FEES | ¤1,017.83 | 09/12/2021 |
| SURCHARGE FS 533.721 | ¤11.30 | 09/12/2021 |
| SURCHARGE - FS 468.631 | ¤16.94 | 09/12/2021 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/12/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,997.34 |