I want to search for...

Permit #2021080991

Permit Details

Status: COED

Parcel Id: 07-11-31-7007-00140-0310
CONDITIONED SPACE: 2699 sqft
GARAGE: 484 sqft
OPENED PORCH (WITH ROOF) : 227 sqft
OPENED PORCH (WITH ROOF) : 151 sqft
Total Square Footage: 3561 sqft
Block: 00140
Subdivision: 2185 - SECTION 7-FLORIDA PARK
Job Phone: 386-447-7007
Location Address: 29 FLEETWOOD DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/09/2021
NOC: RECORDED
Applicant name: MAXIM TARANNIK
Owner: KRASOVSKA, OLEKSANDR & NAUMENKO, PAVLO

Address

306 CHECK AVE

PARLIN, NJ 08859

Lot: 0310
Contracted Stated Job Value: ¤399,400.00
Job Description: single family residence
Type: CN

Contractor

GOLDEN MAGNOLIA, INC
Status Location Address State License Number Phone
INACTIVE

1 ROCKEFELLER DRIVE

PALM COAST, FL 32164

RR282811984 (Exp: 08/31/2025) 386-447-7007

Sub Contractors

GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/23/2023 FINAL APPROVED RMARTIN
Note: 3/22/2023 - PREVIOUS INSPECTION NOTES 3/22/23 NEED TO MOVE OUTLET FROM BEHIND COOKTOP NEC 210.52 3/21/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 3/20/2023 - PREVIOUS INSPECTION NOTES 3/17/2023 - PREVIOUS INSPECTION NOTES 3/16/2023 4:24:36 PM- PREVIOUS INSPECTION NOTES 3/16/2023 - PREVIOUS INSPECTION NOTES 3/10/2023 - PREVIOUS INSPECTION NOTES 3/9/2023 - PREVIOUS INSPECTION NOTES 03-09-2023 1. Energy calcs not on site. 2. D,W drain not tied to underside of sink. 3. Shower head not installed at guest bath. 4. Guest bath water not on. Inspection stopped. 03-10-2023 No inspection, doors locked, need access for inspection. FBC R110.1. Please provide manufacturer's specs for D.W. drain at final inspection. 03-16-2023 1. D,W drain not tied to underside of sink.P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in that position before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece 2. Guest bath water not on. 3. AHU duct not sealed to ceiling. HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5 4. Inspector needs access to attic for inspection. Inspection stopped. 03-17-2023 1. AHU not sealed at base of line set into return. 2. AHU not sealed at base. 3. Guest bath sink water not running. Inspection stopped. A complete inspection is required for next inspection. 03-20-2023 Above issue not addressed. AHU not sealed at base. 03-21-2023 Above issue has not been resolved. Back of AHU not sealed.
BLD - BUILDING FINAL 03/22/2023 Disapproved - NO FEE RMARTIN
Note: 3/22/23 NEED TO MOVE OUTLET FROM BEHIND COOKTOP NEC 210.52 3/21/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 3/20/2023 - PREVIOUS INSPECTION NOTES 3/17/2023 - PREVIOUS INSPECTION NOTES 3/16/2023 4:24:36 PM- PREVIOUS INSPECTION NOTES 3/16/2023 - PREVIOUS INSPECTION NOTES 3/10/2023 - PREVIOUS INSPECTION NOTES 3/9/2023 - PREVIOUS INSPECTION NOTES 03-09-2023 1. Energy calcs not on site. 2. D,W drain not tied to underside of sink. 3. Shower head not installed at guest bath. 4. Guest bath water not on. Inspection stopped. 03-10-2023 No inspection, doors locked, need access for inspection. FBC R110.1. Please provide manufacturer's specs for D.W. drain at final inspection. 03-16-2023 1. D,W drain not tied to underside of sink.P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in that position before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece 2. Guest bath water not on. 3. AHU duct not sealed to ceiling. HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5 4. Inspector needs access to attic for inspection. Inspection stopped. 03-17-2023 1. AHU not sealed at base of line set into return. 2. AHU not sealed at base. 3. Guest bath sink water not running. Inspection stopped. A complete inspection is required for next inspection. 03-20-2023 Above issue not addressed. AHU not sealed at base. 03-21-2023 Above issue has not been resolved. Back of AHU not sealed.
BLD - BUILDING FINAL 03/21/2023 CANCELLED BY APPLICANT WEB
Note: 3/20/2023 - PREVIOUS INSPECTION NOTES 3/17/2023 - PREVIOUS INSPECTION NOTES 3/16/2023 4:24:36 PM- PREVIOUS INSPECTION NOTES 3/16/2023 - PREVIOUS INSPECTION NOTES 3/10/2023 - PREVIOUS INSPECTION NOTES 3/9/2023 - PREVIOUS INSPECTION NOTES 03-09-2023 1. Energy calcs not on site. 2. D,W drain not tied to underside of sink. 3. Shower head not installed at guest bath. 4. Guest bath water not on. Inspection stopped. 03-10-2023 No inspection, doors locked, need access for inspection. FBC R110.1. Please provide manufacturer's specs for D.W. drain at final inspection. 03-16-2023 1. D,W drain not tied to underside of sink.P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in that position before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece 2. Guest bath water not on. 3. AHU duct not sealed to ceiling. HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5 4. Inspector needs access to attic for inspection. Inspection stopped. 03-17-2023 1. AHU not sealed at base of line set into return. 2. AHU not sealed at base. 3. Guest bath sink water not running. Inspection stopped. A complete inspection is required for next inspection. 03-20-2023 Above issue not addressed. AHU not sealed at base.
BLD - BUILDING FINAL 03/21/2023 Disapproved -FEE REQUIRED AGAETANO
Note: New inspection due to canceled inspection 3/20/2023 - PREVIOUS INSPECTION NOTES 3/17/2023 - PREVIOUS INSPECTION NOTES 3/16/2023 4:24:36 PM- PREVIOUS INSPECTION NOTES 3/16/2023 - PREVIOUS INSPECTION NOTES 3/10/2023 - PREVIOUS INSPECTION NOTES 3/9/2023 - PREVIOUS INSPECTION NOTES 03-09-2023 1. Energy calcs not on site. 2. D,W drain not tied to underside of sink. 3. Shower head not installed at guest bath. 4. Guest bath water not on. Inspection stopped. 03-10-2023 No inspection, doors locked, need access for inspection. FBC R110.1. Please provide manufacturer's specs for D.W. drain at final inspection. 03-16-2023 1. D,W drain not tied to underside of sink.P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in that position before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece 2. Guest bath water not on. 3. AHU duct not sealed to ceiling. HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5 4. Inspector needs access to attic for inspection. Inspection stopped. 03-17-2023 1. AHU not sealed at base of line set into return. 2. AHU not sealed at base. 3. Guest bath sink water not running. Inspection stopped. A complete inspection is required for next inspection. 03-20-2023 Above issue not addressed. AHU not sealed at base. 03-21-2023 Above issue has not been resolved. Back of AHU not sealed.
BLD - BUILDING FINAL 03/20/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 3/17/2023 - PREVIOUS INSPECTION NOTES 3/16/2023 4:24:36 PM- PREVIOUS INSPECTION NOTES 3/16/2023 - PREVIOUS INSPECTION NOTES 3/10/2023 - PREVIOUS INSPECTION NOTES 3/9/2023 - PREVIOUS INSPECTION NOTES 03-09-2023 1. Energy calcs not on site. 2. D,W drain not tied to underside of sink. 3. Shower head not installed at guest bath. 4. Guest bath water not on. Inspection stopped. 03-10-2023 No inspection, doors locked, need access for inspection. FBC R110.1. Please provide manufacturer's specs for D.W. drain at final inspection. 03-16-2023 1. D,W drain not tied to underside of sink.P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in that position before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece 2. Guest bath water not on. 3. AHU duct not sealed to ceiling. HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5 4. Inspector needs access to attic for inspection. Inspection stopped. 03-17-2023 1. AHU not sealed at base of line set into return. 2. AHU not sealed at base. 3. Guest bath sink water not running. Inspection stopped. A complete inspection is required for next inspection. 03-20-2023 Above issue not addressed. AHU not sealed at base.
BLD - BUILDING FINAL 03/17/2023 CANCELLED BY APPLICANT STHOMAS
Note: 3/16/2023 - PREVIOUS INSPECTION NOTES 3/10/2023 - PREVIOUS INSPECTION NOTES 3/9/2023 - PREVIOUS INSPECTION NOTES 03-09-2023 1. Energy calcs not on site. 2. D,W drain not tied to underside of sink. 3. Shower head not installed at guest bath. 4. Guest bath water not on. Inspection stopped. 03-10-2023 No inspection, doors locked, need access for inspection. FBC R110.1. Please provide manufacturer's specs for D.W. drain at final inspection. 03-16-2023 1. D,W drain not tied to underside of sink.P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in that position before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece 2. Guest bath water not on. 3. AHU duct not sealed to ceiling. HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5 4. Inspector needs access to attic for inspection. Inspection stopped.
BLD - BUILDING FINAL 03/17/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 3/16/2023 4:24:36 PM- PREVIOUS INSPECTION NOTES 3/16/2023 - PREVIOUS INSPECTION NOTES 3/10/2023 - PREVIOUS INSPECTION NOTES 3/9/2023 - PREVIOUS INSPECTION NOTES 03-09-2023 1. Energy calcs not on site. 2. D,W drain not tied to underside of sink. 3. Shower head not installed at guest bath. 4. Guest bath water not on. Inspection stopped. 03-10-2023 No inspection, doors locked, need access for inspection. FBC R110.1. Please provide manufacturer's specs for D.W. drain at final inspection. 03-16-2023 1. D,W drain not tied to underside of sink.P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in that position before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece 2. Guest bath water not on. 3. AHU duct not sealed to ceiling. HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5 4. Inspector needs access to attic for inspection. Inspection stopped. 03-17-2023 1. AHU not sealed at base of line set into return. 2. AHU not sealed at base. 3. Guest bath sink water not running. Inspection stopped. A complete inspection is required for next inspection.
BLD - BUILDING FINAL 03/16/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 3/10/2023 - PREVIOUS INSPECTION NOTES 3/9/2023 - PREVIOUS INSPECTION NOTES 03-09-2023 1. Energy calcs not on site. 2. D,W drain not tied to underside of sink. 3. Shower head not installed at guest bath. 4. Guest bath water not on. Inspection stopped. 03-10-2023 No inspection, doors locked, need access for inspection. FBC R110.1. Please provide manufacturer's specs for D.W. drain at final inspection. 03-16-2023 1. D,W drain not tied to underside of sink.P2717.2 Sink and dishwasher. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in that position before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece 2. Guest bath water not on. 3. AHU duct not sealed to ceiling. HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5 4. Inspector needs access to attic for inspection. Inspection stopped.
BLD - BUILDING FINAL 03/10/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 3/9/2023 - PREVIOUS INSPECTION NOTES 03-09-2023 1. Energy calcs not on site. 2. D,W drain not tied to underside of sink. 3. Shower head not installed at guest bath. 4. Guest bath water not on. Inspection stopped. 03-10-2023 No inspection, doors locked, need access for inspection. FBC R110.1. Please provide manufacturer's specs for D.W. drain at final inspection.
BLD - BUILDING FINAL 03/09/2023 CANCELLED BY APPLICANT WEB
BLD - BUILDING FINAL 03/09/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 03-09-2023 1. Energy calcs not on site. 2. D,W drain not tied to underside of sink. 3. Shower head not installed at guest bath. 4. Guest bath water not on. Inspection stopped.
WALL SHEATHING 02/08/2023 APPROVED TSTAUFFACHER
Note: 10/13/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2490 Inspector Notes from Inspection 2320 THIS IS A REINSPECTION Back right window not installed. Window nailing added. 08-24-2022 - Back right window stops not installed. Window glass broken. Check stops at next inspection. 08-29-2022 - Back right window stops not installed. Window glass broken. Check stops at next inspection. Cable wires at entry under trusses. 10-13-2022 Home has been completed with stucco. Please provide engineering to the building department for the wall sheathing installed at the entry.
ROW - FINAL APRON (AFTER POUR) 02/08/2023 APPROVED PFLANAGAN
ROW - STORMWATER FINAL 02/08/2023 FINAL APPROVED PFLANAGAN
U -UTILITY RESIDENTIAL FINAL 02/08/2023 FINAL APPROVED DHANEY
ROW FIELD SURVEY /GRADING CERTIFICATION 02/07/2023 APPROVED PFLANAGAN
ROW- PROJECT STATUS 02/07/2023 APPROVED GBERTOLA
Note: meeting with the builder
FINAL SURVEY (OFFICE USE ONLY) 02/07/2023 APPROVED PFLANAGAN
Note: 1/31/2023 - PREVIOUS INSPECTION NOTES ALL THE DRIANAGE NEEDS TO FLOW FROM BACK TO THE FRONT. NEED TO REGRADE BACK YARD SO ALL DRAINAGE FLOW TO THE FRONT OR IF THE WATER DOES FLOW TO THE FRONT YOU NEED TO GET YOUR SURVEYOR TO SHOW THAT IT DOES THIS IS UP TO YOU TO DETERMINE THE ROUTE YOU TAKE.
FINAL SURVEY (OFFICE USE ONLY) 01/31/2023 Disapproved - NO FEE PFLANAGAN
Note: ALL THE DRIANAGE NEEDS TO FLOW FROM BACK TO THE FRONT. NEED TO REGRADE BACK YARD SO ALL DRAINAGE FLOW TO THE FRONT OR IF THE WATER DOES FLOW TO THE FRONT YOU NEED TO GET YOUR SURVEYOR TO SHOW THAT IT DOES THIS IS UP TO YOU TO DETERMINE THE ROUTE YOU TAKE.
ROW- PRE-APRON (PRE-POUR) 11/22/2022 APPROVED EMADISON
Note: ** 11/22/22 MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** READY TO POUR RECHECK ELEVATIONS AND COMPACTION IN THE EVENT OF RAIN 11/15/2022 - PREVIOUS INSPECTION NOTES ** 11/15/22 MATERIAL AROUND CULVERT NEEDS TO BE COMPACTED 1/2 WAY UP PIPE THERE BUILDER NEEDS TO ALSO NEED TO RE-ESTABLISH FOOTERS ON BOTH ENDS OF CULVERT AND REBAR NEEDS TO BE ON SITE 11/4/2022 - PREVIOUS INSPECTION NOTES ** 11/04/22 INSPECTION CANCELLED BY APPLICANT **AT&T IS BLOCKING SITE DUG OUT A TRENCH IN THE APRON ALONG SIDE CULVERT PIPE IN THE APRON. 11/3/2022 - PREVIOUS INSPECTION NOTES ** 11/03/22 NEED TO CHIP AWAY OVER POUR IN FRONT OF GARAGE DOOR NEED A MINIMUM OF 4 INCHES OF CONCRETE ABOVE THE ROW. ** NEED TO TAKE HIGH SPOT DOWN MID WAY IN DRIVEWAY OUTLINED WITH RED PAINT. ** NEED MORE COMPACTION AROUND CULVERT PIPE NEEDS TO BE BURIED 1/2 WAY UP AND COMPACTED
ROW- PRE-APRON (PRE-POUR) 11/15/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 11/15/22 MATERIAL AROUND CULVERT NEEDS TO BE COMPACTED 1/2 WAY UP PIPE THERE BUILDER NEEDS TO ALSO NEED TO RE-ESTABLISH FOOTERS ON BOTH ENDS OF CULVERT AND REBAR NEEDS TO BE ON SITE 11/4/2022 - PREVIOUS INSPECTION NOTES ** 11/04/22 INSPECTION CANCELLED BY APPLICANT **AT&T IS BLOCKING SITE DUG OUT A TRENCH IN THE APRON ALONG SIDE CULVERT PIPE IN THE APRON. 11/3/2022 - PREVIOUS INSPECTION NOTES ** 11/03/22 NEED TO CHIP AWAY OVER POUR IN FRONT OF GARAGE DOOR NEED A MINIMUM OF 4 INCHES OF CONCRETE ABOVE THE ROW. ** NEED TO TAKE HIGH SPOT DOWN MID WAY IN DRIVEWAY OUTLINED WITH RED PAINT. ** NEED MORE COMPACTION AROUND CULVERT PIPE NEEDS TO BE BURIED 1/2 WAY UP AND COMPACTED
ELECTRIC - EARLY POWER 11/09/2022 APPROVED - AS NOTED AGAETANO
Note: 11-09-2022 Front and back doors do not have glass installed. Please cover prior to Hurricane Nicole.
ROW- PRE-APRON (PRE-POUR) 11/04/2022 CANCELLED BY APPLICANT EMADISON
Note: ** 11/04/22 INSPECTION CANCELLED BY APPLICANT **AT&T IS BLOCKING SITE DUG OUT A TRENCH IN THE APRON ALONG SIDE CULVERT PIPE IN THE APRON. 11/3/2022 - PREVIOUS INSPECTION NOTES ** 11/03/22 NEED TO CHIP AWAY OVER POUR IN FRONT OF GARAGE DOOR NEED A MINIMUM OF 4 INCHES OF CONCRETE ABOVE THE ROW. ** NEED TO TAKE HIGH SPOT DOWN MID WAY IN DRIVEWAY OUTLINED WITH RED PAINT. ** NEED MORE COMPACTION AROUND CULVERT PIPE NEEDS TO BE BURIED 1/2 WAY UP AND COMPACTED
ROW- PRE-APRON (PRE-POUR) 11/03/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 11/03/22 NEED TO CHIP AWAY OVER POUR IN FRONT OF GARAGE DOOR NEED A MINIMUM OF 4 INCHES OF CONCRETE ABOVE THE ROW. ** NEED TO TAKE HIGH SPOT DOWN MID WAY IN DRIVEWAY OUTLINED WITH RED PAINT. ** NEED MORE COMPACTION AROUND CULVERT PIPE NEEDS TO BE BURIED 1/2 WAY UP AND COMPACTED
U-CROSS CONNECTION 10/13/2022 APPROVED - AS NOTED DHANEY
Note: Yard not installed yet - no cross CN. .
U - SEWER TIE IN 10/13/2022 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
GRAVITY SEWER TEST 10/13/2022 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
WALL SHEATHING 10/13/2022 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2490 Inspector Notes from Inspection 2320 THIS IS A REINSPECTION Back right window not installed. Window nailing added. 08-24-2022 - Back right window stops not installed. Window glass broken. Check stops at next inspection. 08-29-2022 - Back right window stops not installed. Window glass broken. Check stops at next inspection. Cable wires at entry under trusses. 10-13-2022 Home has been completed with stucco. Please provide engineering to the building department for the wall sheathing installed at the entry.
PEP TANK INSTALLATION REQUEST 10/12/2022 CANCELLED BY APPLICANT WEB
INSULATION 08/29/2022 APPROVED - AS NOTED AGAETANO
Note: Inspector Notes from Inspection 2320 THIS IS A REINSPECTION Back right window not installed. Window nailing added. 08-24-2022 - Back right window stops not installed. Window glass broken. Check stops at next inspection. 08-29-2022 - Back right window stops not installed. Window glass broken. Check stops at next inspection. Cable wires at entry under trusses.
LATH/BRICK/ WATER BARRIER 08/24/2022 APPROVED - AS NOTED AGAETANO
Note: THIS IS A REINSPECTION Back right window not installed. Window nailing added. 08-24-2022 - Back right window stops not installed. Window glass broken. Check stops at next inspection.
ALL ROUGH 08/19/2022 APPROVED AGAETANO
Note: THIS IS A REINSPECTION New inspection due to canceled inspection Inspector Notes from Inspection 2425 Nailing/attachment ok, have glass repaired replaced by final 08-17-2022 - 1. Wires not phased out in electrical panel. 2. Screws missing in window behind garage, check all. 3. Fans not wired.
ALL ROUGH 08/17/2022 Disapproved - NO FEE AGAETANO
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2425 Nailing/attachment ok, have glass repaired replaced by final\ 08-17-2022 - 1. Wires not phased out in electrical panel. 2. Screws missing in window behind garage, check all. 3. Fans not wired.
ALL ROUGH 08/16/2022 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2425 Nailing/attachment ok, have glass repaired replaced by final
WINDOW NAILING 08/11/2022 APPROVED - AS NOTED DCUSHING
Note: Nailing/attachment ok, have glass repaired replaced by final
LATH/BRICK/ WATER BARRIER 08/01/2022 PARTIALLY APPROVED AGAETANO
Note: Back right window not installed. Window nailing added.
ROOF VALLEY & METAL 05/02/2022 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/22/2022 APPROVED - AS NOTED RMARTIN
Note: TRUSS BUCKET G2 IN FRONT BED ROOM NEEDS MORE NAILES IN BUCKET, CHECK AT ALL ROUGH
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/18/2022 CANCELLED BY APPLICANT WEB
TIE BEAM / LINTEL 03/01/2022 APPROVED AGAETANO
FOUND SURVEY APPROVED (OFFICE) 12/28/2021 APPROVED TBAKER
MONOLITHIC SLAB 12/06/2021 APPROVED DCUSHING
PLUMBING 1ST ROUGH UNDERGROUND 11/24/2021 APPROVED DCUSHING
WATER METER INSTALLATION REQUEST 11/12/2021 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 03/14/2023 03/15/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 11/07/2022 11/07/2022
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The required file naming convention is to be followed for all documents uploaded. Please refer to website for the document submittal requirements (file naming).
ENGIN1 COMPLETE 12/28/2021 12/28/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/28/2021 12/28/2021
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM
ZON COMPLETE 10/01/2021 10/04/2021
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 10/01/2021 10/04/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/01/2021 10/04/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 10/01/2021 10/08/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
MECH COMPLETE 09/22/2021 09/22/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 09/22/2021 09/22/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 09/22/2021 09/22/2021
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS: Second Request Please provide an up to date City of Palm Coast Roofing Working Sheet
ZON HOLD 09/22/2021 09/22/2021
Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM 2 nd request: Site plan: is still missing the rear setback please provide
SW1 COMPLETE 09/22/2021 09/30/2021
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/22/2021 09/22/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 08/18/2021 08/19/2021
Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS: Please provide an up to date City of Palm Coast Roofing Working Sheet
CUSVC COMPLETE 08/18/2021 08/25/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 08/18/2021 08/19/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit riser diagram
ENGIN1 COMPLETE 08/18/2021 08/18/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 08/18/2021 08/19/2021
Note: Released By: TONI CHURCHILL - -
MECH HOLD 08/18/2021 08/19/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder
SW1 HOLD 08/18/2021 08/25/2021
Note: Held By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM See uploaded Stormwater checklist in attachments for correction. Make corrections on all unchecked items.
ZON HOLD 08/18/2021 08/20/2021
Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Landscape plan is missing the legend Site plan is missing the rear setback please provide
SWALE COMPLETE 08/18/2021 11/10/2021
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 03/23/2023
REINSPECTION RESIDENTIAL ¤40.00 03/23/2023
REINSPECTION RESIDENTIAL ¤40.00 03/23/2023
REINSPECTION RESIDENTIAL ¤40.00 03/23/2023
REINSPECTION RESIDENTIAL ¤40.00 03/23/2023
REINSPECTION RESIDENTIAL ¤40.00 03/23/2023
REINSPECTION RESIDENTIAL ¤40.00 03/23/2023
CONTRACTOR CHANGE ¤20.00 03/23/2023
CONTRACTOR CHANGE ¤40.00 03/23/2023
CONTRACTOR CHANGE ¤40.00 03/23/2023
SW ENG REINSPECTION 20 ¤20.00 03/23/2023
SW ENG REINSPECTION 30 ¤30.00 03/23/2023
SW ENG REINSPECTION 30 ¤30.00 03/23/2023
SW ENG INSPECTION 60 ¤60.00 11/09/2021
SURCHARGE - FS 468.631 ¤22.65 11/09/2021
SURCHARGE FS 533.721 ¤15.10 11/09/2021
SW ENG - FOUNDATION SURVEY ¤20.00 11/09/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 11/09/2021
IMPACT FEE PARKS ¤1,199.12 11/09/2021
IMPACT FEE SCHOOL ¤3,600.00 11/09/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 11/09/2021
INSUFFICIENT FUNDS ¤20.00 11/09/2021
WATER -IRRIGATION INSPECTION ¤25.00 11/09/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 11/09/2021
IMPACT FEE FIRE ¤367.00 11/09/2021
INSPECTION - RESIDENTIAL ¤1,100.00 11/09/2021
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/09/2021
CONNECTION FEES ¤1,017.83 11/09/2021
METER - DEPOSIT ¤60.00 11/09/2021
WATER- TURN ON ¤25.00 11/09/2021
SW ENG - REVIEW 20 ¤20.00 11/09/2021
PLAN REVIEW - RESIDENTIAL ¤312.00 11/09/2021
SW ENG PRE APRON ¤30.00 11/09/2021
SW ENG RES REVIEW 200 ¤200.00 11/09/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 11/09/2021
SEWER INSPECTION ¤25.00 11/09/2021
SEWER CAPITAL FACILITY ¤4,664.55 11/09/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 11/09/2021
SITE PLAN 30 ¤30.00 11/09/2021
SITE PLAN 30 ¤30.00 11/01/2021
SITE PLAN 30 (¤30.00) 11/01/2021
SEWER CAPITAL FACILITY ¤4,664.55 11/01/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 11/01/2021
WATER CAPITAL FACILITY FEE (¤3,424.45) 11/01/2021
SEWER INSPECTION ¤25.00 11/01/2021
SEWER CAPITAL FACILITY (¤4,664.55) 11/01/2021
SEWER INSPECTION (¤25.00) 11/01/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 11/01/2021
3% TRANS IMPACT FEE CREDIT ¤51.54 11/01/2021
SW ENG - REVIEW 20 ¤20.00 11/01/2021
SW ENG RES REVIEW 200 ¤200.00 11/01/2021
SW ENG RES REVIEW 200 (¤200.00) 11/01/2021
WATER- TURN ON ¤25.00 11/01/2021
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/01/2021
ADMINISTRATIVE RESIDENTIAL (¤30.00) 11/01/2021
WATER- TURN ON (¤25.00) 11/01/2021
METER - DEPOSIT ¤60.00 11/01/2021
METER - DEPOSIT (¤60.00) 11/01/2021
CONNECTION FEES (¤1,017.83) 11/01/2021
CONNECTION FEES ¤1,017.83 11/01/2021
INSPECTION - RESIDENTIAL (¤1,100.00) 11/01/2021
INSPECTION - RESIDENTIAL ¤1,100.00 11/01/2021
PLAN REVIEW - RESIDENTIAL ¤312.00 11/01/2021
PLAN REVIEW - RESIDENTIAL (¤312.00) 11/01/2021
IMPACT FEE FIRE ¤367.00 11/01/2021
IMPACT FEE PARKS ¤1,199.12 11/01/2021
IMPACT FEE PARKS (¤1,199.12) 11/01/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 11/01/2021
3% FIRE IMPACT FEE CREDIT ¤11.01 11/01/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 11/01/2021
SURCHARGE FS 533.721 ¤15.10 11/01/2021
SURCHARGE FS 533.721 (¤15.10) 11/01/2021
WATER -IRRIGATION INSPECTION ¤25.00 11/01/2021
3% PARKS IMPACT FEE CREDIT ¤35.97 11/01/2021
WATER -IRRIGATION INSPECTION (¤25.00) 11/01/2021
IMPACT FEE SCHOOL ¤3,600.00 11/01/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 11/01/2021
IMPACT FEE TRANSPORTATION (¤1,718.00) 11/01/2021
IMPACT FEE SCHOOL (¤3,600.00) 11/01/2021
IMPACT FEE FIRE (¤367.00) 11/01/2021
SW ENG INSPECTION 60 (¤60.00) 11/01/2021
SURCHARGE - FS 468.631 (¤22.65) 11/01/2021
SURCHARGE - FS 468.631 ¤22.65 11/01/2021
SW ENG - FOUNDATION SURVEY ¤20.00 11/01/2021
SW ENG - FOUNDATION SURVEY (¤20.00) 11/01/2021
SW ENG INSPECTION 60 ¤60.00 11/01/2021
SW ENG PRE APRON ¤30.00 11/01/2021
SW ENG PRE APRON (¤30.00) 11/01/2021
SW ENG - REVIEW 20 (¤20.00) 11/01/2021
Fees Total Due: ¤0.00 Total Paid: ¤18,339.68