I want to search for...
Permit #2021081493
Permit Details
Status: FINAL
| Parcel Id: 03-12-31-0000-01010-0120 |
| Total Square Footage: 34300 sqft |
| Block: 01010 |
| Subdivision: - |
| Job Phone: 407-448-9300 |
| Location Address: 6372 STATE HWY 100 E |
| Type: CFND - COMMERCIAL FOUNDATION |
| Issue Date: 09/01/2021 |
| NOC: RECORDED |
| Applicant name: GARY WAYNE BRIDGES |
| Owner: BELLA CITA STORAGE LLC |
|
Address 880 BAY ROAD MOUNT DORA, FL 32757 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤0.00 |
| Job Description: BUILDING I - "FOUNDATION ONLY" SELF STORAGE FACILITY |
| Type: CN |
Contractor
G&M CONSTRUCTION SERVICES, INC.
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 2316 ORLANDO, FL 32804 |
CGC062542 (Exp: 08/31/2022) | 407-448-9300 |
Sub Contractors
MATTHEW JAMES BLANCHARD
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 932 MT. DORA, FL 32757 |
EC13009373 (Exp: 08/31/2022) | 352-383-4868 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC UNDERGROUND | 11/02/2021 | APPROVED - AS NOTED | RMARTIN |
| Note: BUILDING E UNDERGROUND | |||
| FOOTER | 10/26/2021 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Need approved details on site for inspection 10-21-21... typical footing detail CF-2 calls for two layers of steel each way, footing ntes call fot one layer, Engineer was consulted and it was confirmed that he wants two layers. (only one layer each way was installed. Please install second layer at location indicated for top layer. | |||
| FOOTER | 10/22/2021 | Disapproved -FEE REQUIRED | LMILLER |
| Note: THIS IS A REINSPECTION Need approved details on site for inspection 10-21-21... typical footing detail CF-2 calls for two layers of steel each way, footing ntes call fot one layer, Engineer was consulted and it was confirmed that he wants two layers. (only one layer each way was installed. Please install second layer at location indicated for top layer. | |||
| FOOTER | 10/20/2021 | Disapproved -FEE REQUIRED | LMILLER |
| Note: Need approved details on site for inspection |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 08/30/2021 | 08/30/2021 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 09/01/2021 |
| INSPECTION COMMERCIAL | ¤60.00 | 09/01/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 09/01/2021 |
| SURCHARGE - FS 468.631 | ¤2.09 | 09/01/2021 |
| REINSPECTION - COMMERCIAL | ¤60.00 | |
| REINSPECTION - COMMERCIAL | ¤60.00 | |
| Fees | Total Due: ¤120.00 | Total Paid: ¤139.09 |