Permit #2021090125
Permit Details
Status: COED
| Parcel Id: 07-11-31-7009-00200-0370 |
| CONDITIONED SPACE: 1804 sqft |
| GARAGE: 491 sqft |
| OPENED PORCH (WITH ROOF) : 270 sqft |
| OPENED PORCH (WITH ROOF) : 28 sqft |
| Total Square Footage: 2593 sqft |
| Block: 00200 |
| Subdivision: 2208 - SECTION 9-FLORIDA PARK |
| Job Phone: 321-271-9033 |
| Location Address: 17 FAIRMONT LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/18/2021 |
| NOC: RECORDED |
| Applicant name: KEITH E TANNER |
| Owner: VINTAGE ESTATE HOMES LLC |
|
Address 4885 N WICKHAM ROAD MELBOURNE, FL 32940 |
| Lot: 0370 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MERCEDES PREMIER HOMES, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
4885 N WICKHAM RD MELBOURNE, FL 32940 |
STE 101 MELBOURNE, FL 32940 |
CGC1516602 (Exp: 08/31/2024) | 321-610-3924 |
Sub Contractors
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
ZACHARY PETER BOERA
| Status | Location Address | State License Number | Phone |
| CANCEL |
7225 SANDSCOVE COURT, SUITE 1 WINTER PARK, FL 32792 |
CAC1817652 (Exp: 08/31/2022) | 407-629-6920 |
Inspection History
| Type | Request Date | Result | Inspector |
| U-CROSS CONNECTION | 07/21/2022 | APPROVED | DHANEY |
| Note: Note; double check backflow has not been installed yet by utility dept. . | |||
| BLD - BUILDING FINAL | 07/20/2022 | FINAL APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION 1. Entry and lanai receptacles not working. 2. Kitchen sink does not have hot water. FIXTURE FITTING HOT WATER. P2722.2 3. Energy calcs not on site. 4. AHU - Refrigerant line, high voltage box, and low voltage wire must be sealed. HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5 07-14-2022 - Energy calcs do not match on the outdoor unit. AHU label not installed. 6030 submitted and 6036 07-18-2022 - 1. AHU label does not have model or serial numbers. They have been cut off. Manufacture's model and serial numbers label need to be placed on the AHU. Label that has been placed on the unit seems to have been removed from another unit and installed on this unit. 2. Garage switch not connected to box. Switch has power. 07-20-2022 - Final Approved as per Building Official. Energy calcs and AHU label will be on site within 30 days. | |||
| BLD - BUILDING FINAL | 07/18/2022 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1. Entry and lanai receptacles not working. 2. Kitchen sink does not have hot water. FIXTURE FITTING HOT WATER. P2722.2 3. Energy calcs not on site. 4. AHU - Refrigerant line, high voltage box, and low voltage wire must be sealed. HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5 07-14-2022 - Energy calcs do not match on the outdoor unit. AHU label not installed. 6030 submitted and 6036 07-18-2022 - 1. AHU label does not have model or serial numbers. They have been cut off. Manufacture's model and serial numbers label need to be placed on the AHU. Label that has been placed on the unit seems to have been removed from another unit and installed on this unit. 2. Garage switch not connected to box. Switch has power. | |||
| BLD - BUILDING FINAL | 07/14/2022 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: THIS IS A REINSPECTION 1. Entry and lanai receptacles not working. 2. Kitchen sink does not have hot water. FIXTURE FITTING HOT WATER. P2722.2 3. Energy calcs not on site. 4. AHU - Refrigerant line, high voltage box, and low voltage wire must be sealed. HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5 07-14-2022 - Energy calcs do not match on the outdoor unit. AHU label not installed. 6030 submitted and 6036 | |||
| BLD - BUILDING FINAL | 07/13/2022 | CANCELLED BY APPLICANT | WEB |
| BLD - BUILDING FINAL | 07/13/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 1. Entry and lanai receptacls not working. 2. Kitchen sink does not have hot water. FIXTURE FITTING HOT WATER. P2722.2 3. Energy calcs not on site. 4. AHU - Refrigerant line, high voltage box, and low voltage wire must be sealed. HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5 | |||
| ROW - STORMWATER FINAL | 07/12/2022 | APPROVED - AS NOTED | EMADISON |
| Note: THIS IS A REINSPECTION ** 07/12/22 CORRECTIONS HAVE BEEN MADE EVERYTHING LOOKS GOOD AT THE TIME OF THE INSPECTION ** BARE AREAS ACROSS BACK PROPERTY LINE NEED TO SEEDED AND STRAW PUT DOWN ** ALSO SOD NEEDS TO BE PUT ALONG LEFT REAR PROPTY LINE BARE SPOTS ** EDGE OF ROAD RIGHT SIDE OF DRIVEWAY NEEDS TO BE REPAIRED ** NOTE TO INSPECTOR SEE FIELD SURVEY NOTES | |||
| U -UTILITY RESIDENTIAL FINAL | 06/27/2022 | APPROVED - AS NOTED | JHARDING |
| Note: No irrigation, no cross connections. | |||
| ROW - STORMWATER FINAL | 06/27/2022 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** BARE AREAS ACROSS BACK PROPERTY LINE NEED TO SEEDED AND STRAW PUT DOWN ** ALSO SOD NEEDS TO BE PUT ALONG LEFT REAR PROPTY LINE BARE SPOTS ** EDGE OF ROAD RIGHT SIDE OF DRIVEWAY NEEDS TO BE REPAIRED ** NOTE TO INSPECTOR SEE FIELD SURVEY NOTES | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/17/2022 | APPROVED - AS NOTED | EMADISON |
| Note: ** ENSURE THAT BARE AREAS ACROSS REAR PROPERTY LINE ARE SEEDED AND STRAW COVERING, ARE DOWN ** DUMPSTER AND PORTA JOHN REMOVED FROM SWALE ACROSS STREET PRIOR TO ROW FINAL | |||
| ROW - FINAL APRON (AFTER POUR) | 06/17/2022 | APPROVED | EMADISON |
| Note: Inspector Notes from Inspection 9465 ** ENSURE THAT BARE AREAS ACROSS REAR PROPERTY LINE ARE SEEDED AND STRAW COVERING, ARE DOWN ** DUMPSTER AND PORTA JOHN REMOVED FROM SWALE ACROSS STREET PRIOR TO ROW FINAL | |||
| FINAL SURVEY (OFFICE USE ONLY) | 06/17/2022 | APPROVED | EMADISON |
| ELECTRIC - EARLY POWER | 06/09/2022 | APPROVED - AS NOTED | JMUNSON |
| Note: Emailed FPL at 9:46 am | |||
| U - SEWER TIE IN | 06/01/2022 | APPROVED | MGIBSON |
| ROW- PRE-APRON (PRE-POUR) | 05/06/2022 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION Culvert is tilted in the wrong direction. Refer to Swale plan directional arrows. 5/6/22 - READY TO POUR | |||
| ROW- PRE-APRON (PRE-POUR) | 05/05/2022 | Disapproved - NO FEE | RGROSS |
| Note: Culvert is tilted in the wrong direction. Refer to Swale plan directional arrows. | |||
| INSULATION | 03/22/2022 | APPROVED | DCUSHING |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION Laundry room next to hallway wall and front room right closet holes needs to be fire blocked. 03-16-2022 - Front room right closet holes not fire blocked. 03-18-2022 - Front room right closet holes at top of wall has not been fire caulked. | |||
| LATH/BRICK/ WATER BARRIER | 03/22/2022 | APPROVED | DCUSHING |
| INSULATION | 03/18/2022 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Laundry room next to hallway wall and front room right closet holes needs to be fire blocked. 03-16-2022 - Front room right closet holes not fire blocked. 03-18-2022 - Front room right closet holes at top of wall has not been fire caulked. | |||
| INSULATION | 03/16/2022 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: THIS IS A REINSPECTION Laundry room next to hallway wall and front room right closet holes needs to be fire blocked. 03-16-2022 - Front room right closet holes not fire blocked. | |||
| INSULATION | 03/15/2022 | Disapproved - NO FEE | AGAETANO |
| Note: Laundry room next to hallway wall and front right right closet holes needs to be fire blocked. | |||
| ALL ROUGH | 03/09/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: 1. Broken window in front right room. 2. Remove foil tape at exhaust fan penetration and apply mastic. 3. Head test not holding water. 4. Sleeve water heater wire. CHECK AT NEXT INSPECTION. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 03/09/2022 | APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION NOT HOLDING HEAD TEST | |||
| ROOF VALLEY & METAL | 02/08/2022 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/07/2022 | APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION 1.Please have approved drawings on site for inspection. 2. Drawings call for 2 straps at B4 Truss. | |||
| WALL SHEATHING | 02/04/2022 | APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION Wall sheathing not nailed in multiple areas. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/04/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 1.Please have approved drawings on site for inspection. 2. Drawings call for 2 straps at B2 Truss. | |||
| FOUND SURVEY APPROVED (OFFICE) | 02/03/2022 | APPROVED | TBAKER |
| WALL SHEATHING | 02/02/2022 | Disapproved - NO FEE | AGAETANO |
| Note: Wall sheathing not nailed in multiple areas. | |||
| TIE BEAM / LINTEL | 12/29/2021 | APPROVED | AGAETANO |
| Note: | |||
| MONOLITHIC SLAB | 12/13/2021 | APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION Plumbing not sleeved nor relief arc installed. No UFER ground. | |||
| MONOLITHIC SLAB | 12/10/2021 | Disapproved - NO FEE | AGAETANO |
| Note: Plumbing not sleeved nor relief arc installed. No UFER ground. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 12/06/2021 | APPROVED | MGIBSON |
| Note: THIS IS A REINSPECTION | |||
| GRAVITY SEWER TEST | 12/06/2021 | APPROVED | MGIBSON |
| Note: THIS IS A REINSPECTION SEE FIRST ROUGH NOTE | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 12/03/2021 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: NOT HOLDING HEAD TEST | |||
| GRAVITY SEWER TEST | 12/03/2021 | Disapproved - NO FEE | MGIBSON |
| Note: SEE FIRST ROUGH NOTE | |||
| WATER METER INSTALLATION REQUEST | 11/02/2021 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 07/15/2022 | 07/18/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/04/2022 | 03/07/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/02/2022 | 02/03/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/02/2022 | 02/02/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/22/2021 | 09/22/2021 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/17/2021 | 09/20/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building PLAN REVIEW COMMENTS: Repeat comments: 1. Provide an updated City of Palm Coast Roofing Worksheet. 2. Properly identify ALL Florida Product Approval Number (i.e. 14170.#); there are various types of approvals. | |||
| PLENV | COMPLETE | 09/17/2021 | 09/17/2021 |
| Note: Released By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM The letter from Tri-County Bobcat Services has been accepted. | |||
| SWALE | COMPLETE | 09/03/2021 | 11/17/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/02/2021 | 09/07/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building PLAN REVIEW COMMENTS: 1. Provide an updated City of Palm Coast Roofing Worksheet. 2. Properly identify ALL Florida Product Approval Number (i.e. 14170.#); there are various types of approvals. | |||
| CUSVC | COMPLETE | 09/02/2021 | 09/08/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 09/02/2021 | 09/03/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/02/2021 | 09/03/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 09/02/2021 | 09/03/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 09/02/2021 | 09/03/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/02/2021 | 09/13/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/02/2021 | 09/07/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| PLENV | HOLD | 09/02/2021 | 09/08/2021 |
| Note: Held By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM Staff conducted a site visit on 9/8/21 and found multiple Potentially Occupied Gopher Tortoise burrows. Please either provide a site plan showing no construction within 25ft of the burrows or an Approved After Action Report from FWC. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 07/20/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/20/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/20/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/20/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/20/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/20/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/20/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 07/20/2022 |
| SW ENG REINSPECTION 20 | ¤20.00 | 07/20/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 10/18/2021 |
| SW ENG RES REVIEW 200 | ¤200.00 | 10/18/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 10/18/2021 |
| SEWER INSPECTION | ¤25.00 | 10/18/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 10/18/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 10/18/2021 |
| SITE PLAN 30 | ¤30.00 | 10/18/2021 |
| METER - DEPOSIT | ¤60.00 | 10/18/2021 |
| WATER- TURN ON | ¤25.00 | 10/18/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/18/2021 |
| INSPECTION - RESIDENTIAL | ¤687.50 | 10/18/2021 |
| PLAN REVIEW - RESIDENTIAL | ¤195.00 | 10/18/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 10/18/2021 |
| IMPACT FEE FIRE | ¤367.00 | 10/18/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 10/18/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 10/18/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 10/18/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 10/18/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 10/18/2021 |
| SURCHARGE FS 533.721 | ¤9.67 | 10/18/2021 |
| SURCHARGE - FS 468.631 | ¤14.50 | 10/18/2021 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 10/18/2021 |
| SW ENG INSPECTION 60 | ¤60.00 | 10/18/2021 |
| SW ENG PRE APRON | ¤30.00 | 10/18/2021 |
| CONNECTION FEES | ¤1,017.83 | 10/18/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤17,656.60 |