I want to search for...

Permit #2021090138

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00490-0120
CONDITIONED SPACE: 2551 sqft
GARAGE: 428 sqft
OPENED PORCH (WITH ROOF) : 160 sqft
OPENED PORCH (WITH ROOF) : 33 sqft
Total Square Footage: 3172 sqft
Block: 00490
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 321-271-9033
Location Address: 32 ESSEX LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/04/2021
NOC: RECORDED
Applicant name: KEITH E TANNER
Owner: LS- VEH LLC

Address

4885 N WICKHAM RD

MELBOURNE, FL 32940

Lot: 0120
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MERCEDES PREMIER HOMES, LLC
Status Location Address Mailing Address State License Number Phone
INACTIVE

4885 N WICKHAM RD

MELBOURNE, FL 32940

STE 101

MELBOURNE, FL 32940

CGC1516602 (Exp: 08/31/2024) 321-610-3924

Sub Contractors

SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000

Inspection History

Type Request Date Result Inspector
ROW - STORMWATER FINAL 09/27/2022 FINAL APPROVED PFLANAGAN
BLD - BUILDING FINAL 09/26/2022 FINAL APPROVED KSANDOE
Note: 9/23/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2425 Rear bedroom left side of building. left side of window jamb missing fasteners. Check at final 9-23-22 1. Ground wire needs protectionNEC 250.62 2. Energy cals don't match. 3. Master bath sink leaking. 4. Master bath toilet light not working. 5. Garbage disposal tripping breaker. 6. Smoke alarms not working.
BLD - BUILDING FINAL 09/23/2022 Disapproved - NO FEE BTAYLOR
Note: Inspector Notes from Inspection 2425 Rear bedroom left side of building. left side of window jamb missing fasteners. Check at final 9-23-22 1. Ground wire needs protectionNEC 250.62 2. Energy cals don't match. 3. Master bath sink leaking. 4. Master bath toilet light not working. 5. Garbage disposal tripping breaker. 6. Smoke alarms not working.
U -UTILITY RESIDENTIAL FINAL 09/21/2022 APPROVED - AS NOTED LFITZGERALD
Note: please lower sewer clean out to be flush with grades-call inspector to verify-Larry at 386-214-3376
U-CROSS CONNECTION 09/21/2022 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ELECTRIC - EARLY POWER 08/31/2022 APPROVED - AS NOTED JMUNSON
Note: Ground wire emerging from grade needs to be protected by final. NEC 2017 250.64
WINDOW NAILING 08/22/2022 APPROVED - AS NOTED JWALKER
Note: Rear bedroom left side of building. left side of window jamb missing fasteners. Check at final
TUB SET 08/15/2022 APPROVED MGIBSON
FINAL SURVEY (OFFICE USE ONLY) 08/12/2022 APPROVED PFLANAGAN
ROW - FINAL APRON (AFTER POUR) 08/12/2022 APPROVED PFLANAGAN
ROW FIELD SURVEY /GRADING CERTIFICATION 08/12/2022 APPROVED PFLANAGAN
ROW- PRE-APRON (PRE-POUR) 07/05/2022 APPROVED - AS NOTED GBERTOLA
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING.
U - SEWER TIE IN 06/22/2022 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 06/09/2022 APPROVED CSTONE
Note: THIS IS A REINSPECTION ADDED ON 5/25/2022 8:17:45 AM Exterior (stucco and or siding not applied EMAIL RHAND@PALMCOASTGOV.COM with questions
PEP TANK INSTALLATION REQUEST 05/24/2022 Disapproved - NO FEE CSTONE
Note: Exterior (stucco and or siding not applied EMAIL RHAND@PALMCOASTGOV.COM with questions
LATH/BRICK/ WATER BARRIER 05/24/2022 APPROVED MKRASKI
Note: THIS IS A REINSPECTION The furring strips around the windows used to seal off opening needs to be removed.
INSULATION 05/18/2022 APPROVED JWALKER
LATH/BRICK/ WATER BARRIER 05/12/2022 Disapproved - NO FEE JWALKER
Note: The furring strips around the windows used to seal off opening needs to be removed.
ALL ROUGH 04/20/2022 APPROVED KSANDOE
Note: THIS IS A REINSPECTION Window and door openings not secure Trades approved/ do not insulate Shingles not installed. Check at insulation
ALL ROUGH 04/19/2022 Disapproved - NO FEE TSTAUFFACHER
Note: Window and door openings not secure Trades approved/ do not insulate
WALL SHEATHING 03/03/2022 APPROVED JWALKER
Note: THIS IS A REINSPECTION
ROOF VALLEY & METAL 03/03/2022 APPROVED JWALKER
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/03/2022 APPROVED - AS NOTED JWALKER
Note: 3/3/22 Valley over framing hold downs not nailed rear slider area. Install L brace at front gable and 2x4 flat block 48" o.c. detail 1201 The piggy back trusses are missing 1 of 4 optional hold down methods. IN ADDITION to the 2x4 at 2' o.c. The details can be found on engineering packet DRWG PB16010118. I left the drawing in the job box zip lock bag
ROOF VALLEY & METAL 03/01/2022 CANCELLED BY APPLICANT RMARTIN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/01/2022 CANCELLED BY APPLICANT RMARTIN
WALL SHEATHING 03/01/2022 CANCELLED BY APPLICANT RMARTIN
FOUND SURVEY APPROVED (OFFICE) 02/18/2022 APPROVED TBAKER
TIE BEAM / LINTEL 02/01/2022 APPROVED JWALKER
MONOLITHIC SLAB 01/11/2022 APPROVED JWALKER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 01/10/2022: Dowel rod missing in back left footing pad Pipes passing through interior load bearing footing footing not sleeved or have re-bar bridge Plans in box are not approved set
MONOLITHIC SLAB 01/10/2022 Disapproved - NO FEE TSTAUFFACHER
Note: THIS IS A REINSPECTION 01/10/2022: Dowel rod missing in back left footing pad Pipes passing through interior load bearing footing footing not sleeved or have re-bar bridge Plans in box are not approved set
MONOLITHIC SLAB 01/06/2022 CANCELLED BY APPLICANT JWALKER
PLUMBING 1ST ROUGH UNDERGROUND 12/28/2021 APPROVED MGIBSON
GRAVITY SEWER TEST 12/28/2021 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 11/24/2021 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 09/23/2022 09/23/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 08/16/2022 08/17/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 07/21/2022 07/22/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Design location on heatload needs to match the Energy calc. (St. Augustine)
ENGIN1 COMPLETE 02/17/2022 02/18/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/17/2022 02/17/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 09/03/2021 09/03/2021
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
CUSVC COMPLETE 09/03/2021 09/08/2021
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 09/03/2021 09/03/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/03/2021 09/03/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 09/03/2021 09/07/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 09/03/2021 09/03/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 09/03/2021 09/14/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
ZON COMPLETE 09/03/2021 09/07/2021
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 09/03/2021 11/16/2021
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 09/27/2022
CONTRACTOR CHANGE ¤40.00 09/27/2022
PLAN REVIEW - REVISION ¤32.50 09/27/2022
PLAN REVIEW - REVISION ¤32.50 09/27/2022
CONNECTION FEES ¤1,017.83 11/04/2021
METER - DEPOSIT ¤60.00 11/04/2021
WATER- TURN ON ¤25.00 11/04/2021
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/04/2021
INSPECTION - RESIDENTIAL ¤847.00 11/04/2021
PLAN REVIEW - RESIDENTIAL ¤240.24 11/04/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 11/04/2021
IMPACT FEE FIRE ¤367.00 11/04/2021
IMPACT FEE PARKS ¤1,199.12 11/04/2021
IMPACT FEE SCHOOL ¤3,600.00 11/04/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 11/04/2021
WATER -IRRIGATION INSPECTION ¤25.00 11/04/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 11/04/2021
SURCHARGE FS 533.721 ¤11.77 11/04/2021
SURCHARGE - FS 468.631 ¤17.65 11/04/2021
SW ENG - FOUNDATION SURVEY ¤20.00 11/04/2021
SW ENG INSPECTION 60 ¤60.00 11/04/2021
SW ENG PRE APRON ¤30.00 11/04/2021
SW ENG - REVIEW 20 ¤20.00 11/04/2021
SW ENG RES REVIEW 200 ¤200.00 11/04/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 11/04/2021
SEWER CREDIT (¤850.00) 11/04/2021
SEWER INSPECTION ¤25.00 11/04/2021
SEWER CAPITAL FACILITY ¤4,664.55 11/04/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 11/04/2021
SITE PLAN 30 ¤30.00 11/04/2021
Fees Total Due: ¤0.00 Total Paid: ¤16,829.09