Permit #2021090412

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-01040-0130
CONDITIONED SPACE: 1215 sqft
CONDITIONED SPACE: 1215 sqft
GARAGE: 332 sqft
GARAGE: 315 sqft
OPENED PORCH (WITH ROOF) : 156 sqft
OPENED PORCH (WITH ROOF) : 156 sqft
OPENED PORCH (WITH ROOF) : 39 sqft
OPENED PORCH (WITH ROOF) : 39 sqft
Total Square Footage: 3467 sqft
Block: 01040
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: 386-237-1210
Location Address: 31 LOUISBURG LN
Type: DU - DUPLEX
Issue Date: 12/20/2021
NOC: RECORDED
Applicant name: ANDREW POPOV
Owner: CFHA INVESTMENTS LLC

Address

9738 US HIGHWAY 192

CLERMONT, FL 34714

Lot: 0130
Contracted Stated Job Value: ¤350,000.00
Job Description: DUPLEX
Type: CN

Contractor

SILVER BREEZE HOMES
Status Location Address State License Number Phone
ACTIVE

1 SEATHORN PATH UNIT A

PALM COAST, FL 32164

RR282812121 (Exp: 08/31/2027) 386-237-7700

Sub Contractors

MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/21/2023 FINAL APPROVED TSTAUFFACHER
U -UTILITY RESIDENTIAL FINAL 02/01/2023 FINAL APPROVED DHANEY
Note: 1/31/2023 - PREVIOUS INSPECTION NOTES No electric to front [closest to road] Pep tank .
U -UTILITY RESIDENTIAL FINAL 01/31/2023 Disapproved - NO FEE DHANEY
Note: No electric to front [closest to road] Pep tank .
ROW FIELD SURVEY /GRADING CERTIFICATION 01/27/2023 APPROVED RGROSS
Note: 1/12/2023 - PREVIOUS INSPECTION NOTES ** 01/12/23 SOD HAS NOT BEEN INSTALLED ON PROPERTY, SITE NNOT READY FOR FINAL SURVEY OR THE FIELD SURVEY. BUILDER NEEDS TO RESUBMIT A FINAL SURVEY AFTER SOD HAS BEEN INSTALLLED
ROW - FINAL INSPECTION 01/27/2023 APPROVED RGROSS
ROW - FINAL APRON (AFTER POUR) 01/27/2023 APPROVED RGROSS
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/27/2023 APPROVED RGROSS
Note: ** 01/12/23 CHANGED THE RESULTED FINAL SURVEY FROM APPROVED TO DISAPPROVED UPON MY ARRIVAL TO CONDUCT THE FIELD SURVEY THERE IS NO SOD ON SITE FINAL SURVEY NEEDS TO HAVE ELEVATIONS ONCE SOD HAS BEEN LAID. ** . BUILDER NEEDS TO RESUBMIT A FINAL SURVEY AFTER SOD HAS BEEN INSTALLLED ___________________________________________________________________________________________________________________________ 1/12/2023 10:17:42 AM- PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9270 12/06/22= CORRECTION WERE MADE. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ___________________________________________________________________________________________________________________________ 12/5/2022 - PREVIOUS INSPECTION NOTES ** 12/05/22 NEED CHIP AWAY THE OVER POUR IN FRONT OF GARAGE DOORS THERE NEEDS TO BE A MINIMUM OF 4 INCHES OF CONCRETE IN THE DRIVEWAY POUR AREA ABOVE THE ROW. ** NOTE TO INSPECTOR: **CULVERT ELEVATIONS WERE GOOD AT THE TIME OF THIS INSPECTION**
ROW FIELD SURVEY /GRADING CERTIFICATION 01/12/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 01/12/23 SOD HAS NOT BEEN INSTALLED ON PROPERTY, SITE NNOT READY FOR FINAL SURVEY OR THE FIELD SURVEY. BUILDER NEEDS TO RESUBMIT A FINAL SURVEY AFTER SOD HAS BEEN INSTALLLED
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/12/2023 Disapproved - NO FEE EMADISON
Note: ** 01/12/23 CHANGED THE RESULTED FINAL SURVEY FROM APPROVED TO DISAPPROVED UPON MY ARRIVAL TO CONDUCT THE FIELD SURVEY THERE IS NO SOD ON SITE FINAL SURVEY NEEDS TO HAVE ELEVATIONS ONCE SOD HAS BEEN LAID. ** . BUILDER NEEDS TO RESUBMIT A FINAL SURVEY AFTER SOD HAS BEEN INSTALLLED Inspector Notes from Inspection 9270 12/06/22= CORRECTION WERE MADE. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ___________________________________________________________________________________________________________________________ 12/5/2022 - PREVIOUS INSPECTION NOTES ** 12/05/22 NEED CHIP AWAY THE OVER POUR IN FRONT OF GARAGE DOORS THERE NEEDS TO BE A MINIMUM OF 4 INCHES OF CONCRETE IN THE DRIVEWAY POUR AREA ABOVE THE ROW. ** NOTE TO INSPECTOR: **CULVERT ELEVATIONS WERE GOOD AT THE TIME OF THIS INSPECTION**
ELECTRIC - EARLY POWER 12/20/2022 APPROVED - AS NOTED KSANDOE
Note: 12/20/22 Emailed FPL @ 0819. Release Power Inspector Notes from Inspection 2170 THIS IS A REINSPECTION NEED TO HAVE POLE GROUNDED PER NEC 250 ALSO NEED TO BRACE POLE SO WILL NOT FALL OVER 2/22/22 Emailed FPL at 10:37 am
ROW- PRE-APRON (PRE-POUR) 12/06/2022 APPROVED - AS NOTED GBERTOLA
Note: 12/06/22= CORRECTION WERE MADE. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ___________________________________________________________________________________________________________________________ 12/5/2022 - PREVIOUS INSPECTION NOTES ** 12/05/22 NEED CHIP AWAY THE OVER POUR IN FRONT OF GARAGE DOORS THERE NEEDS TO BE A MINIMUM OF 4 INCHES OF CONCRETE IN THE DRIVEWAY POUR AREA ABOVE THE ROW. ** NOTE TO INSPECTOR: **CULVERT ELEVATIONS WERE GOOD AT THE TIME OF THIS INSPECTION**
ROW- PRE-APRON (PRE-POUR) 12/05/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 12/05/22 NEED CHIP AWAY THE OVER POUR IN FRONT OF GARAGE DOORS THERE NEEDS TO BE A MINIMUM OF 4 INCHES OF CONCRETE IN THE DRIVEWAY POUR AREA ABOVE THE ROW. ** NOTE TO INSPECTOR: **CULVERT ELEVATIONS WERE GOOD AT THE TIME OF THIS INSPECTION**
U-CROSS CONNECTION 11/29/2022 APPROVED - AS NOTED DHANEY
Note: Yard not installed yet - no cross cn. .
U - SEWER TIE IN 11/29/2022 APPROVED MGIBSON
GRAVITY SEWER TEST 11/29/2022 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 PROVIDE PORTABLE RESTROOM BEFORE SLAB INSPECTION
INSULATION 11/01/2022 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 NEED TO CHECK EXHAUST FANS AT INSULATION FOR CORRECT ROMEX CONNECTORS, NON INSTALLED
PEP TANK INSTALLATION REQUEST 10/24/2022 APPROVED CSTONE
ALL ROUGH 10/18/2022 APPROVED - AS NOTED RMARTIN
Note: NEED TO CHECK EXHAUST FANS AT INSULATION FOR CORRECT ROMEX CONNECTORS, NON INSTALLED
ROOF VALLEY & METAL 10/17/2022 APPROVED FWILLIS
FIREWALL FINAL 10/06/2022 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/06/2022 APPROVED FWILLIS
Note: 10/5/2022 - PREVIOUS INSPECTION NOTES 10/4/2022 - PREVIOUS INSPECTION NOTES PLANS ARE INCOMPLE PAGES MISSING. A5, A6.... DETAIL SHEET 10/5/22 - ELECTRICIANS RUNNING WIRES BOTH UNITS, MULTIPLE TRIP HAZARDS ON THE FLOOR. CANNOT PERFORM INSPECTION SAFELY AND THORUGHLY WITH WIRES, BOXES AND TOOLS ON FLOOR THROUGHOUT.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/05/2022 Disapproved - NO FEE FWILLIS
Note: 10/4/2022 - PREVIOUS INSPECTION NOTES PLANS ARE INCOMPLE PAGES MISSING. A5, A6.... DETAIL SHEET 10/5/22 - ELECTRICIANS RUNNING WIRES BOTH UNITS, MULTIPLE TRIP HAZARDS ON THE FLOOR. CANNOT PERFORM INSPECTION SAFELY AND THORUGHLY WITH WIRES, BOXES AND TOOLS ON FLOOR THROUGHOUT.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/04/2022 Disapproved -FEE REQUIRED FWILLIS
Note: PLANS ARE INCOMPLE PAGES MISSING. A5, A6.... DETAIL SHEET
FIREWALL DRYWALL NAILING 10/04/2022 APPROVED FWILLIS
LATH/BRICK/ WATER BARRIER 07/12/2022 APPROVED RMARTIN
Note: THIS IS A REINSPECTION APPROVED DRAWINGS IN CONSTRUCTION BOX MISSING PAGES.
LATH/BRICK/ WATER BARRIER 07/11/2022 Disapproved - NO FEE FWILLIS
Note: APPROVED DRAWINGS IN CONSTRUCTION BOX MISSING PAGES.
TIE BEAM / LINTEL 06/10/2022 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 03/16/2022 APPROVED TBAKER
MONOLITHIC SLAB 03/04/2022 APPROVED FWILLIS
ELECTRIC TEMP POLE 02/22/2022 APPROVED - AS NOTED JMUNSON
Note: THIS IS A REINSPECTION NEED TO HAVE POLE GROUNDED PER NEC 250 ALSO NEED TO BRACE POLE SO WILL NOT FALL OVER 2/22/22 Emailed FPL at 10:37 am
ELECTRIC TEMP POLE 02/14/2022 Disapproved - NO FEE RMARTIN
Note: NEED TO HAVE POLE GROUNDED PER NEC 250 ALSO NEED TO BRACE POLE SO WILL NOT FALL OVER
PLUMBING 1ST ROUGH UNDERGROUND 02/07/2022 APPROVED - AS NOTED MGIBSON
Note: PROVIDE PORTABLE RESTROOM BEFORE SLAB INSPECTION
WATER METER INSTALLATION REQUEST 01/04/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
BADMIN INFORMATION 01/30/2023 01/30/2023
Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM Termite has wrong address.
BLD COMPLETE 04/20/2022 04/20/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ELEC COMPLETE 04/20/2022 04/20/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/15/2022 03/16/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/15/2022 03/15/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 09/28/2021 09/29/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 09/28/2021 09/29/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BADMIN COMPLETE 09/27/2021 09/28/2021
Note: Released By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM
ELEC COMPLETE 09/27/2021 09/27/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 09/27/2021 09/28/2021
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS: 1. OK 2. OK 3. OK 4. OK 5. OK a. Properly identify Florida Product Approval Number for the Garage (i.e. 15012.#); there are various types of approvals. b. OK
MECH HOLD 09/27/2021 09/27/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder, below the preparer
SWALE COMPLETE 09/10/2021 11/18/2021
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
BLD HOLD 09/09/2021 09/10/2021
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building Residential REVIEW COMMENTS: 1. Submitted plans reference the 2017 Florida Building 6th Edition. As of January 1, 2021, Florida State adopted the 2020 Florida State Building Code 7th Edition. Code and Code References need to be revised to reference the current Code. 2. Door from Garage into the Living Space is required to be 20 minute fire rated per R302.5. 3. Detail 4 – 1 Hour Wall Section appears to be incomplete. Revise the Detail to show the proposed Fire Wall continue to the Roof. Provide were the wall ends. If the wall ends at the underside of the underside of the roof, fire rated plywood, 4 foot in both directions is required. 4. Sheet A6 appears have to missing UL Details. Provide Details noted on proposed sheet. 5. Product Approval on Roofing Worksheet is different than submitted on the Product Approval Sheet. A revision is required to reflect the correct Product Approval. a. Product Approval for Garage Door is not correct. A revision is required for the correct product Approval is required. b. Product Approval for proposed Soffit materials is not correct. A revision is required for the correct product Approval is required.
CUSVC COMPLETE 09/09/2021 09/16/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 09/09/2021 09/10/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Update all code years on cover page. 2. Need GFCI outlets next to all bathroom sinks. NEC 2017 210.52 (D)
ENGIN1 COMPLETE 09/09/2021 09/10/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 09/09/2021 09/10/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 09/09/2021 09/13/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs say R38 insulation in attic. Plans show R30. Revise to match 2. Energy Calcs and EPL card need to be signed by the builder
SW1 COMPLETE 09/09/2021 09/16/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
ZON COMPLETE 09/09/2021 09/10/2021
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM
BADMIN HOLD 09/09/2021 09/09/2021
Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM the lien law affidavit was not rejected on the first submittal due to the lack of notarization. This will need to be submitted prior to issuance (cannot be submitted during an open review cycle)

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG REINSPECTION 20 ¤20.00 01/29/2023
SW ENG REINSPECTION 30 ¤30.00 01/29/2023
REINSPECTION RESIDENTIAL ¤40.00 10/04/2022
PLAN REVIEW - REVISION ¤32.50 07/14/2022
WATER -IRRIGATION INSPECTION ¤50.00 12/20/2021
SURCHARGE FS 533.721 ¤13.29 12/20/2021
SURCHARGE - FS 468.631 ¤19.93 12/20/2021
SW ENG - FOUNDATION SURVEY ¤20.00 12/20/2021
SW ENG INSPECTION 60 ¤60.00 12/20/2021
SW ENG PRE APRON ¤30.00 12/20/2021
SW ENG - REVIEW 20 ¤20.00 12/20/2021
SW ENG RES REVIEW 200 ¤200.00 12/20/2021
SEWER CREDIT (¤1,700.00) 12/20/2021
SEWER INSPECTION ¤25.00 12/20/2021
SEWER CAPITAL FACILITY ¤9,329.10 12/20/2021
WATER CAPITAL FACILITY FEE ¤6,848.90 12/20/2021
SITE PLAN 30 ¤30.00 12/20/2021
METER - DEPOSIT ¤120.00 12/20/2021
WATER- TURN ON ¤50.00 12/20/2021
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/20/2021
INSPECTION - RESIDENTIAL ¤962.50 12/20/2021
PLAN REVIEW - RESIDENTIAL ¤273.00 12/20/2021
IMPACT FEE FIRE ¤734.00 12/20/2021
IMPACT FEE PARKS ¤2,398.24 10/24/2021
IMPACT FEE SCHOOL ¤7,200.00 10/24/2021
IMPACT FEE TRANSPORTATION ¤2,666.00 10/24/2021
CONNECTION FEES ¤2,035.66 10/24/2021
Fees Total Due: ¤0.00 Total Paid: ¤31,538.12