I want to search for...
Permit #2021090942
Permit Details
Status: COED
| Parcel Id: 33-11-31-3061-00090-0040 |
| CONDITIONED SPACE: 2443 sqft |
| CONDITIONED SPACE: 269 sqft |
| GARAGE: 764 sqft |
| OPENED PORCH (WITH ROOF) : 442 sqft |
| OPENED PORCH (WITH ROOF) : 91 sqft |
| Total Square Footage: 4009 sqft |
| Block: 00090 |
| Subdivision: 2108 - HIDDEN LAKES PHASE II - TOSCANA |
| Job Phone: 863-420-2100 |
| Location Address: 78 NEW LEATHERWOOD DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/19/2021 |
| NOC: RECORDED |
| Applicant name: YUVAL BOTANSKY |
| Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC |
|
Address 131 CHADWICK DRIVE DAVENPORT, FL 33837 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: single family residence |
| Type: CN |
Contractor
APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 CHADWICK DRIVE DAVENPORT, FL 33837 |
CRC1330762 (Exp: 08/31/2026) | 863-420-2100 | 386-517-6865 |
Sub Contractors
TERRY HILE BURD
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO Box 180308 CASSELBERRY, FL 32707 |
CAC1814423 (Exp: 08/31/2024) | (407) 831-3600 | (407)831-2893 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2022) | 877-906-1113 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
DAVID MILLER
| Status | Location Address | State License Number | Phone |
| CANCEL |
2659 MERCY DRIVE ORLANDO, FL 32808 |
06157 (Exp: 08/31/2024) | 407-466-6514 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
NICHOLAS KEITH REX
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1408 HAMLIN UNIT B SAINT CLOUD, FL 34771 |
EC13006779 (Exp: 08/31/2026) | 407-873-2231 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/23/2023 | FINAL APPROVED | TSTAUFFACHER |
| Note: | |||
| U-CROSS CONNECTION | 01/18/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: has reclaim irrigation- no cross connection | |||
| U -UTILITY RESIDENTIAL FINAL | 01/18/2023 | FINAL APPROVED | LFITZGERALD |
| ROW - FINAL APRON (AFTER POUR) | 01/17/2023 | APPROVED | GBERTOLA |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/17/2023 | APPROVED | GBERTOLA |
| ROW - STORMWATER FINAL | 01/17/2023 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD | |||
| FINAL SURVEY (OFFICE USE ONLY) | 01/17/2023 | APPROVED | GBERTOLA |
| ELECTRIC - EARLY POWER | 01/10/2023 | APPROVED | JMUNSON |
| ROW- PRE-APRON (PRE-POUR) | 01/05/2023 | APPROVED | PFLANAGAN |
| Note: READY FOR PAVERS ---------------------------------------------------------------- READY TO POUR CONCRETE FOR 1. SIDEWALK 2. APRON 3. PAVER RESTRAINTS BEFORE THE NEXT PRE POUR INSPECTION ALL PAVER BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS AT THE TIME OF THE INSPECTIION. ALSO NEED TO FIXS THE CHIPS IN THE CURB | |||
| ROW- PRE-APRON (PRE-POUR) | 12/28/2022 | APPROVED - AS NOTED | PFLANAGAN |
| Note: READY TO POUR CONCRETE FOR 1. SIDEWALK 2. APRON 3. PAVER RESTRAINTS BEFORE THE NEXT PRE POUR INSPECTION ALL PAVER BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS AT THE TIME OF THE INSPECTIION. ALSO NEED TO FIXS THE CHIPS IN THE CURB | |||
| U - SEWER TIE IN | 12/02/2022 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 12/02/2022 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 10/12/2022 | APPROVED | DCUSHING |
| Note: Inspector Notes from Inspection 2490 9/20/2022 - PREVIOUS INSPECTION NOTES Foam used as fireblocking in annular holes appears to be standard gap foam. Remove and replace with a firestop rated system as listed below R302.4.1.2 Penetration firestop system. Penetrations shall be protected by an approved penetration firestop system installed as tested in accordance with ASTM E814 or UL 1479, with a positive pressure differential of not less than 0.01 inch of water (3 Pa) and shall have an F rating of not less than the required fire-resistance rating of the wall or floor-ceiling assembly penetrated. R302.4.1 Through penetrations. The material used to fill the annular space shall prevent the passage of flame and hot gases sufficient to ignite cotton waste where subjected to ASTM E119 or UL 263 time temperature fire conditions under a positive pressure differential of not less than 0.01 inch of water (3 Pa) at the location of the penetration for the time period equivalent to the fire-resistance rating of the construction penetrated. 9/22/22 contractor had letter from insulation company, material is approved | |||
| INSULATION | 09/22/2022 | APPROVED - AS NOTED | RMARTIN |
| Note: 9/20/2022 - PREVIOUS INSPECTION NOTES Foam used as fireblocking in annular holes appears to be standard gap foam. Remove and replace with a firestop rated system as listed below R302.4.1.2 Penetration firestop system. Penetrations shall be protected by an approved penetration firestop system installed as tested in accordance with ASTM E814 or UL 1479, with a positive pressure differential of not less than 0.01 inch of water (3 Pa) and shall have an F rating of not less than the required fire-resistance rating of the wall or floor-ceiling assembly penetrated. R302.4.1 Through penetrations. The material used to fill the annular space shall prevent the passage of flame and hot gases sufficient to ignite cotton waste where subjected to ASTM E119 or UL 263 time temperature fire conditions under a positive pressure differential of not less than 0.01 inch of water (3 Pa) at the location of the penetration for the time period equivalent to the fire-resistance rating of the construction penetrated. 9/22/22 contractor had letter from insulation company, material is approved | |||
| INSULATION | 09/20/2022 | Disapproved - NO FEE | KSANDOE |
| Note: Foam used as fireblocking in annular holes appears to be standard gap foam. Remove and replace with a firestop rated system as listed below R302.4.1.2 Penetration firestop system. Penetrations shall be protected by an approved penetration firestop system installed as tested in accordance with ASTM E814 or UL 1479, with a positive pressure differential of not less than 0.01 inch of water (3 Pa) and shall have an F rating of not less than the required fire-resistance rating of the wall or floor-ceiling assembly penetrated. R302.4.1 Through penetrations. The material used to fill the annular space shall prevent the passage of flame and hot gases sufficient to ignite cotton waste where subjected to ASTM E119 or UL 263 time temperature fire conditions under a positive pressure differential of not less than 0.01 inch of water (3 Pa) at the location of the penetration for the time period equivalent to the fire-resistance rating of the construction penetrated. | |||
| ALL ROUGH | 09/16/2022 | APPROVED | LMILLER |
| Note: 9/15/2022 - PREVIOUS INSPECTION NOTES 9/14/2022 - PREVIOUS INSPECTION NOTES not ready, plumbers still working, Inpesction Stopped 9/15/22 Need to phase out electric in panel box. Fire blocking throughout fire blocking integrity must be maintained (broken in half at romex) Nail plates for plumbing supply lines at top plates throughout. 9-16-22 notes above resolved | |||
| ALL ROUGH | 09/15/2022 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 9/14/2022 - PREVIOUS INSPECTION NOTES not ready, plumbers still working, Inpesction Stopped 9/15/22 Need to phase out electric in panel box. Fire blocking throughout fire blocking integrity must be maintained (broken in half at romex) Nail plates for plumbing supply lines at top plates throughout. | |||
| ALL ROUGH | 09/14/2022 | Disapproved - NO FEE | LMILLER |
| Note: not ready, plumbers still working, Inpesction Stopped | |||
| ROOF VALLEY & METAL | 06/28/2022 | APPROVED | LMILLER |
| WALL SHEATHING | 06/23/2022 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/22/2022 | APPROVED | MKRASKI |
| Note: | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/28/2022 | PARTIALLY APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION this is for entryway beams only per notes... conditions at site do not match plans, make the project match the plans or obtain an approved revision 01/28/2022: Please get approved letter from engineer that describes and states that exactly what is built is acceptable. UNderstanding it is a non-load bearing wall, the as built does not meet what is on plans. Have letter be specific to include any tie downs, framing members,etc. Continue to proceed with home, entry will be re-checked at next inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/18/2022 | Disapproved - NO FEE | LMILLER |
| Note: this is for entryway beams only per notes... conditions at site do not match plans, make the project match the plans or obtain an approved revision | |||
| FOUND SURVEY APPROVED (OFFICE) | 01/05/2022 | APPROVED | TBAKER |
| ELECTRIC-TUG | 01/03/2022 | APPROVED - AS NOTED | JMUNSON |
| Note: Emailed FPL at 9:10 am | |||
| TIE BEAM / LINTEL | 12/17/2021 | APPROVED | LMILLER |
| MONOLITHIC SLAB | 12/06/2021 | APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION Not ready, dowels not set n12-06-21... otes above resolved | |||
| MONOLITHIC SLAB | 12/03/2021 | Disapproved -FEE REQUIRED | TSTAUFFACHER |
| Note: Not ready, dowels not set | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/29/2021 | APPROVED | MGIBSON |
| FOOTER | 11/01/2021 | APPROVED | TSTAUFFACHER |
| WATER METER INSTALLATION REQUEST | 10/25/2021 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 08/25/2022 | 08/25/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/05/2022 | 07/05/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/08/2022 | 02/09/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/01/2022 | 02/02/2022 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Revision: Provide revised plan sheet A-3 and identify the changes made with a "clouded" symbol based on the latest revision dated 1-25-22 for clarity per FBC 7th Ed. Sec. 107.3. | |||
| BLD | COMPLETE | 01/25/2022 | 01/25/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/05/2022 | 01/05/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/05/2022 | 01/05/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/04/2021 | 10/04/2021 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/04/2021 | 10/05/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/04/2021 | 10/11/2021 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/21/2021 | 09/22/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 09/21/2021 | 09/24/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 09/21/2021 | 09/22/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/21/2021 | 09/21/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 09/21/2021 | 09/28/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 09/21/2021 | 09/22/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/21/2021 | 09/29/2021 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 09/21/2021 | 09/21/2021 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Windows facing right of way must be wrapped with banding | |||
| URB | COMPLETE | 09/21/2021 | 09/23/2021 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/13/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 09/14/2022 |
| PLAN REVIEW - REVISION | ¤32.50 | 09/14/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/14/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 09/14/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 09/14/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 10/19/2021 |
| IMPACT FEE FIRE | ¤367.00 | 10/19/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 10/19/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 10/19/2021 |
| IMPACT FEE TRANSPORTATION | ¤3,139.00 | 10/19/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 10/19/2021 |
| SURCHARGE FS 533.721 | ¤13.43 | 10/19/2021 |
| SURCHARGE - FS 468.631 | ¤20.15 | 10/19/2021 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 10/19/2021 |
| SW ENG INSPECTION 60 | ¤60.00 | 10/19/2021 |
| SW ENG PRE APRON | ¤30.00 | 10/19/2021 |
| SW ENG - REVIEW 20 | ¤20.00 | 10/19/2021 |
| SW ENG RES REVIEW 200 | ¤200.00 | 10/19/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤94.17) | 10/19/2021 |
| SEWER INSPECTION | ¤25.00 | 10/19/2021 |
| SITE PLAN 30 | ¤30.00 | 10/19/2021 |
| CONNECTION FEES | ¤25.00 | 10/19/2021 |
| METER - DEPOSIT | ¤60.00 | 10/19/2021 |
| WATER-METER | ¤441.07 | 10/19/2021 |
| WATER-METER | ¤366.42 | 10/19/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/19/2021 |
| INSPECTION - RESIDENTIAL | ¤973.50 | 10/19/2021 |
| PLAN REVIEW - RESIDENTIAL | ¤276.12 | 10/19/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,979.66 |