I want to search for...
Permit #2021090960
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7030-00440-0060 |
| CONDITIONED SPACE: 2138 sqft |
| GARAGE: 743 sqft |
| OPENED PORCH (WITH ROOF) : 242 sqft |
| PATIO/DECK (NO ROOF) : 84 sqft |
| Total Square Footage: 3207 sqft |
| Block: 00440 |
| Subdivision: 2154 - SECTION 30-ROYAL PALMS |
| Job Phone: 386-263-8272 |
| Location Address: 2 RANGER PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/14/2021 |
| NOC: RECORDED |
| Applicant name: ROY CHARLES WALDHAUER |
| Owner: BARBOSA JOMALDO |
|
Address 34 RICHMOND DRIVE PALM COAST, FL 32164 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤292,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
BY THE SHORE INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1600 N STATE STREET # 102 , |
CRC1327300 (Exp: 08/31/2026) | 386-263-8272 | 386-263-8289 |
Sub Contractors
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
THOMAS A REGULA
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11320 PHILLIPS PKWY DRIVE E JACKSONVILLE, FL 32256 |
CMC1250075 (Exp: 08/31/2026) | 904-278-0339 | 904-278-0366 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
CHARLES K DAVIS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3000 E MOODY BLVD BLDG 2 BUNNELL , FL 32110 |
EC13004270 (Exp: 08/31/2026) | 386-931-6614 |
Inspection History
| Type | Request Date | Result | Inspector |
| U-CROSS CONNECTION | 09/20/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irrigatin-no cross connection | |||
| BLD - BUILDING FINAL | 04/10/2023 | FINAL APPROVED | KSANDOE |
| Note: 4/5/2023 - PREVIOUS INSPECTION NOTES 1. The spary form in the attic needs to have the thermal barrier properly installed. If using approved paint please leave the used paint can onsite for reinspection. 2. Arch fault circut breakers are to be installed at the electrical panel for Kitchen circuts. NEC 201.12 3. Rear porch light not working off the switch. 4. Master bedroom needs to have a light or a switched outlet. NEC 210.70 | |||
| BLD - BUILDING FINAL | 04/05/2023 | Disapproved - NO FEE | JWALKER |
| Note: 1. The spary form in the attic needs to have the thermal barrier properly installed. If using approved paint please leave the used paint can onsite for reinspection. 2. Arch fault circut breakers are to be installed at the electrical panel for Kitchen circuts. NEC 201.12 3. Rear porch light not working off the switch. 4. Master bedroom needs to have a light or a switched outlet. NEC 210.70 | |||
| U -UTILITY RESIDENTIAL FINAL | 03/31/2023 | FINAL APPROVED | LFITZGERALD |
| Note: 3/22/2023 - PREVIOUS INSPECTION NOTES still power not hooked up to pep panel 3/3/2023 - PREVIOUS INSPECTION NOTES no power to pep panel/circuit breaker in garage for pep tank not identified | |||
| U -UTILITY RESIDENTIAL FINAL | 03/22/2023 | Disapproved -FEE REQUIRED | LFITZGERALD |
| Note: still power not hooked up to pep panel 3/3/2023 - PREVIOUS INSPECTION NOTES no power to pep panel/circuit breaker in garage for pep tank not identified | |||
| ROW - STORMWATER FINAL | 03/09/2023 | FINAL APPROVED | EMADISON |
| Note: ** 03/29/23 CORRECTIONS MADE _________________________________________________________________________________________________________________________ New inspection due to canceled inspection NEED TO REMOVE THE POTTY FROM THE SWALE REPAIR THE SWALE WHERE THE POTTY WAS, WITH SOD | |||
| U -UTILITY RESIDENTIAL FINAL | 03/03/2023 | Disapproved -FEE REQUIRED | LFITZGERALD |
| Note: no power to pep panel/circuit breaker in garage for pep tank not identified | |||
| ROW - STORMWATER FINAL | 03/03/2023 | CANCELLED BY APPLICANT | WEB |
| Note: NEED TO REMOVE THE POTTY FROM THE SWALE REPAIR THE SWALE WHERE THE POTTY WAS, WITH SOD | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/02/2023 | APPROVED | GBERTOLA |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/02/2023 | APPROVED | GBERTOLA |
| ROW - FINAL APRON (AFTER POUR) | 03/02/2023 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD | |||
| ELECTRIC - EARLY POWER | 03/02/2023 | APPROVED | JWALKER |
| Note: 3/1/2023 - PREVIOUS INSPECTION NOTES 3/1/23 The outlet must be removed. It is not readily accessible in that location wether it will be used or not. 2/28/2023 - PREVIOUS INSPECTION NOTES 2/28/23 1. Item 2 listed below has not been corrected. A set of orange Allen keys were left on the meter can likely from the service wire change. I placed the allen keys on the kitchen sink. 2/27/2023 - PREVIOUS INSPECTION NOTES 1. The sevice wire at the weather head do not have SUNLIGHT RESISTANT MARKINGS. Please install approved conductors. 2. The outlet installed behind the dishwasher will need to be removed as it is not readily accessible. 3. The outlet under the kitchen sink is not safed off. | |||
| ELECTRIC - EARLY POWER | 03/01/2023 | Disapproved - NO FEE | JWALKER |
| Note: 3/1/23 The outlet must be removed. It is not readily accessible in that location wether it will be used or not. 2/28/2023 - PREVIOUS INSPECTION NOTES 2/28/23 1. Item 2 listed below has not been corrected. A set of orange Allen keys were left on the meter can likely from the service wire change. I placed the allen keys on the kitchen sink. 2/27/2023 - PREVIOUS INSPECTION NOTES 1. The sevice wire at the weather head do not have SUNLIGHT RESISTANT MARKINGS. Please install approved conductors. 2. The outlet installed behind the dishwasher will need to be removed as it is not readily accessible. 3. The outlet under the kitchen sink is not safed off. | |||
| ELECTRIC - EARLY POWER | 02/28/2023 | Disapproved - NO FEE | JWALKER |
| Note: 2/28/23 1. Item 2 listed below has not been corrected. A set of orange Allen keys were left on the meter can likely from the service wire change. I placed the allen keys on the kitchen sink. 2/27/2023 - PREVIOUS INSPECTION NOTES 1. The sevice wire at the weather head do not have SUNLIGHT RESISTANT MARKINGS. Please install approved conductors. 2. The outlet installed behind the dishwasher will need to be removed as it is not readily accessible. 3. The outlet under the kitchen sink is not safed off. | |||
| ELECTRIC - EARLY POWER | 02/27/2023 | Disapproved - NO FEE | JWALKER |
| Note: 1. The sevice wire at the weather head do not have SUNLIGHT RESISTANT MARKINGS. Please install approved conductors. 2. The outlet installed behind the dishwasher will need to be removed as it is not readily accessible. 3. The outlet under the kitchen sink is not safed off. | |||
| ROW- PRE-APRON (PRE-POUR) | 01/18/2023 | APPROVED | GBERTOLA |
| Note: 118/23= CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL _____________________________________________________________________________________________________________________ 1/17/2023 - PREVIOUS INSPECTION NOTES WINGS ON THE APRON NEED TO BE 36 INCH THE WAY IS FORM IS WRONG. CULVERT PIPE IS GOOD. NEED TO REMOVE THE FORM BOARD DIVIDING THE 2 DRIVEWAYS | |||
| ROW- PRE-APRON (PRE-POUR) | 01/17/2023 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: WINGS ON THE APRON NEED TO BE 36 INCH THE WAY IS FORM IS WRONG. CULVERT PIPE IS GOOD. NEED TO REMOVE THE FORM BOARD DIVIDING THE 2 DRIVEWAYS | |||
| U - SEWER TIE IN | 12/08/2022 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 12/08/2022 | APPROVED | MGIBSON |
| PEP TANK INSTALLATION REQUEST | 11/15/2022 | APPROVED | CSTONE |
| Note: 10/20/2022 11:36:50 AM- PREVIOUS INSPECTION NOTES – Interior ( sheet rock must be hung or at least on site) & Exterior (stucco, stone, brick, or siding must be applied) | |||
| LATH/BRICK/ WATER BARRIER | 10/28/2022 | APPROVED - AS NOTED | JWALKER |
| Note: 10/27/22 The sevice wire at the weather head do not have SUNLIGHT RESISTANT MARKINGS. Please install approved conductors. Check at final inspection for wire change. | |||
| INSULATION | 10/25/2022 | APPROVED - AS NOTED | JWALKER |
| Note: Spray foam in garage attic will need to have a thremal barrier installed over it. Due to it being used for storage. R-316.5.3 HVAC line set at garage wall needs to be protected. Check items above at Final | |||
| PEP TANK INSTALLATION REQUEST | 10/20/2022 | Disapproved - NO FEE | CSTONE |
| Note: – Interior ( sheet rock must be hung or at least on site) & Exterior (stucco, stone, brick, or siding must be applied) | |||
| ALL ROUGH | 10/19/2022 | APPROVED - AS NOTED | JWALKER |
| Note: HVAC line set at garage wall needs to be protected. Dryer duct and kitchen exhaust duct. Seal the snap locks. Seal the concrete floor right side bath 2" PVC drain line | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/05/2022 | APPROVED | BTAYLOR |
| Note: THIS IS A REINSPECTION 1 The structure of the roof does not appear to be sound 2 Have engineer walk the job. 3 All ridge beams appear to need to have support. A contious load path. Two wall ends where 2x4s double were used to support the ridge ends are buckled and bowing. Have engineer supply a letter to the building department stating the roof is structually approved or provide a revison showing bearing supports and anchorage. 4 Have engineer provide a ceiling framing drawing showing size of materail to be used any beams to be installed. 5 5 Show all ceiling joist hangers as built. Several areas of the ceiling have been framed with 2x6 being spliced together. Have engineer letter showing the splice are acceptable and a detail showing how the splices are to be constructed. 2 x 12 rafters common and jack rafters have been spliced together. Have engineer povide a revised detail showing how these rafters are to be spliced togeth and constructed. Intall moisture barriers on all not P.T. lumber in contact with the cmu walls. where missing. Install missing anchors on hip rafter ends where missing. Circled areas on the print. Due to miters not being cut at jack to hip rafter please have engineer show anchors needed to secure the jack to the hip. A seprate rood sheating inspection has already been approved. Stopped inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/15/2022 | Disapproved - NO FEE | JWALKER |
| Note: 1 The structure of the roof does not appear to be sound 2 Have engineer walk the job. 3 All ridge beams appear to need to have support. A contious load path. Two wall ends where 2x4s double were used to support the ridge ends are buckled and bowing. Have engineer supply a letter to the building department stating the roof is structually approved or provide a revison showing bearing supports and anchorage. 4 Have engineer provide a ceiling framing drawing showing size of materail to be used any beams to be installed. 5 5 Show all ceiling joist hangers as built. Several areas of the ceiling have been framed with 2x6 being spliced together. Have engineer letter showing the splice are acceptable and a detail showing how the splices are to be constructed. 2 x 12 rafters common and jack rafters have been spliced together. Have engineer povide a revised detail showing how these rafters are to be spliced togeth and constructed. Intall moisture barriers on all not P.T. lumber in contact with the cmu walls. where missing. Install missing anchors on hip rafter ends where missing. Circled areas on the print. Due to miters not being cut at jack to hip rafter please have engineer show anchors needed to secure the jack to the hip. A seprate rood sheating inspection has already been approved. Stopped inspection. | |||
| ROOF VALLEY & METAL | 08/02/2022 | APPROVED | JWALKER |
| ROOF SHEATHING | 07/14/2022 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION ADDED ON 6/14/2022 8:04:55 AM | |||
| WALL SHEATHING | 07/14/2022 | APPROVED | JWALKER |
| ROOF SHEATHING | 06/14/2022 | CANCELLED BY APPLICANT | MRAMOS |
| TIE BEAM / LINTEL | 05/02/2022 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION The precast lintel above the 2 car opening calls for 2 # 5 rebar in the lintel. Detail on page 5 of 6 of the prints. Please install second bar. | |||
| TIE BEAM / LINTEL | 04/27/2022 | Disapproved - NO FEE | JWALKER |
| Note: The precast lintel above the 2 car opening calls for 2 # 5 rebar in the lintel. Detail on page 5 of 6 of the prints. Please install second bar. | |||
| FOUND SURVEY APPROVED (OFFICE) | 03/14/2022 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 02/24/2022 | APPROVED | JWALKER |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/04/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 12/28/2021 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/03/2022 | 10/03/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/07/2022 | 09/08/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: Repeat Comments All comments are from the Building Inspectors inspection on 8/15/2022 1. All ridge beams appear to need to have support. A continues load path. Two wall ends where 2x4s double were used to support the ridge ends are buckled and bowing. Have engineer supply a letter to the building department stating the roof is structurally approved or provide a revision showing bearing supports and anchorage. 2. Have engineer provide a ceiling framing drawing showing size of material to be used any beams to be installed. 5 5 Show all ceiling joist hangers as built. Several areas of the ceiling have been framed with 2x6 being spliced together. Have engineer revise plans to show the splices are acceptable and a detail showing how the splices are to be constructed. 3. 2 x 12 rafters common and jack rafters have been spliced together. Have engineer provide a revised detail showing how these rafters are to be spliced together and constructed. Submitted plan corrected several issues but, the ones mentioned above were not corrected | |||
| BLD | COMPLETE | 05/09/2022 | 05/09/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/25/2022 | 04/26/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Residential REVIEW COMMENTS: 1. Multiple Span tales and methods have been submitted. Provide if the Engineered or Prescriptive Method is to be used. FBC [A]107. 2. Option #2, 2x4 SP, Total Span of 2x6 is noted for 2x4 span. Revise to reflect the correct span. FBC [A]107. | |||
| BLD | HOLD | 03/30/2022 | 03/31/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: Repeat Comment 1. Proposed 2 x 10 rafters appear over spanned per the 2018 Wood Frame Construction Manual. A revision is required. FC 107 | |||
| BLD | HOLD | 03/15/2022 | 03/16/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Proposed 2 x 10 rafters appear over spanned per the 2018 Wood Frame Construction Manual. A revision is required. FC 107 | |||
| ENGIN1 | COMPLETE | 03/14/2022 | 03/14/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/14/2022 | 03/14/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM no zoning changes | |||
| BLD | COMPLETE | 11/09/2021 | 11/10/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/09/2021 | 11/09/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 11/09/2021 | 11/16/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/09/2021 | 11/17/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 11/09/2021 | 11/09/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 11/09/2021 | 11/10/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 10/27/2021 | 12/01/2021 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/26/2021 | 10/27/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/26/2021 | 10/27/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/26/2021 | 10/26/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/26/2021 | 10/27/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Provide species of lumber to be used.Repeat Comment | |||
| ELEC | COMPLETE | 10/26/2021 | 10/26/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/26/2021 | 11/01/2021 |
| Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/21/2021 | 09/22/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building Residential REVIEW COMMENTS: 1. Provide a completed and up to date City of Palm Coast Roofing Worksheet. 2. Provide species of lumber to be used. 3. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 13/8 inches (35 mm) in thickness, solid or honeycombcore steel doors not less than 13/8 inches (35 mm) thick, or 20-minute fire-rated doors. | |||
| CUSVC | COMPLETE | 09/21/2021 | 09/24/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | HOLD | 09/21/2021 | 09/22/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit floor plan Submit electric load calcs | |||
| ENGIN1 | HOLD | 09/21/2021 | 09/22/2021 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM No survey in submittal package. | |||
| LOCATE | COMPLETE | 09/21/2021 | 09/27/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 09/21/2021 | 09/22/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide Floor Plan 2. Plans show R30 insulation in attic with vented soffit. Energy calcs show R20 on roof deck with non vented soffit. Revise to match | |||
| SW1 | HOLD | 09/21/2021 | 09/28/2021 |
| Note: Held By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM look at the sample site plan in the stormwater informational packet there are no elevations or drainage features please look at the sample and the checklist and revise your site plan | |||
| ZON | HOLD | 09/21/2021 | 09/22/2021 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Please provide a floor plan with square footage of home. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 04/04/2023 |
| REINSPECTION FEE | ¤40.00 | 04/04/2023 |
| REINSPECTION FEE | ¤40.00 | 04/04/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 04/04/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 04/04/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 04/04/2023 |
| CONNECTION FEES | ¤1,017.83 | 12/14/2021 |
| SW ENG - REVIEW 20 | ¤20.00 | 12/14/2021 |
| SW ENG RES REVIEW 200 | ¤200.00 | 12/14/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 12/14/2021 |
| SEWER CREDIT | (¤1,342.00) | 12/14/2021 |
| SEWER INSPECTION | ¤25.00 | 12/14/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 12/14/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 12/14/2021 |
| SITE PLAN 30 | ¤30.00 | 12/14/2021 |
| SURCHARGE FS 533.721 | ¤11.19 | 12/14/2021 |
| SURCHARGE - FS 468.631 | ¤16.78 | 12/14/2021 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 12/14/2021 |
| SW ENG INSPECTION 60 | ¤60.00 | 12/14/2021 |
| SW ENG PRE APRON | ¤30.00 | 12/14/2021 |
| METER - DEPOSIT | ¤60.00 | 12/14/2021 |
| WATER- TURN ON | ¤25.00 | 12/14/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/14/2021 |
| INSPECTION - RESIDENTIAL | ¤803.00 | 12/14/2021 |
| PLAN REVIEW - RESIDENTIAL | ¤227.76 | 12/14/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 12/14/2021 |
| IMPACT FEE FIRE | ¤367.00 | 12/14/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 12/14/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 12/14/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 12/14/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 12/14/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 12/14/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤16,329.16 |