I want to search for...

Permit #2021090962

Permit Details

Status: COED

Parcel Id: 07-11-31-7057-00290-0230
CONDITIONED SPACE: 2219 sqft
GARAGE: 699 sqft
OPENED PORCH (WITH ROOF) : 245 sqft
OPENED PORCH (WITH ROOF) : 67 sqft
Total Square Footage: 3230 sqft
Block: 00290
Subdivision: -
Job Phone: 386-263-8272
Location Address: 325 UNDERWOOD TR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/13/2021
NOC: RECORDED
Applicant name: ROY CHARLES WALDHAUER
Owner: ALISON DESIGN PROPERTIES LLC

Address

337 UNDERWOOD TRAIL

PALM COAST, FL 32164

Lot: 0230
Contracted Stated Job Value: ¤297,200.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

BY THE SHORE INC.
Status Location Address State License Number Phone Fax
ACTIVE

1600 N STATE STREET # 102

,

CRC1327300 (Exp: 08/31/2026) 386-263-8272 386-263-8289

Sub Contractors

DANIEL DAVID RUTKOWSKI III
Status Location Address State License Number Phone Fax
ACTIVE

1687 STATE AVENUE

HOLLY HILL, FL 32117

CCC1328639 (Exp: 08/31/2026) 386-290-7490 386-256-0001
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
CHARLES K DAVIS
Status Location Address State License Number Phone
ACTIVE

3000 E MOODY BLVD BLDG 2

BUNNELL , FL 32110

EC13004270 (Exp: 08/31/2026) 386-931-6614

Inspection History

Type Request Date Result Inspector
WALL SHEATHING 10/05/2023 APPROVED BTAYLOR
BLD - BUILDING FINAL 10/05/2023 FINAL APPROVED BTAYLOR
U-CROSS CONNECTION 10/05/2023 APPROVED - AS NOTED JHARDING
Note: No irrigation, no cross connections.
ROW - FINAL APRON (AFTER POUR) 10/05/2023 APPROVED - AS NOTED FSLADISH
Note: 10/005/23 PIPES ARE GOOD, CUTS MADE. CULVERT CLEAR. HOT PATCH AND ROAD REPAIR COMPLETED. SPOKE WITH THE CM ONSITE AT THE TIME OF THIS INSPECTION, LET HIM KNOW THAT THERE IS A LITTLE OVERPOUR ON THE CULVERT ENDS THAT WILL NEED TO BE TAKEN CARE OF. HE IS STARTING TO MAKE CORRECTION AS I WRITE THIS INSPECTION REPORT. I AM PASSING THIS INSPECTION AS NOTED THAT THIS CORRECTION WILL BE MADE IMMEDIATELY.. Inspector Notes from Inspection 9465 10/03/23 UPON WALKING PROPERTY DRAINAGE APPEARS TO WORK AS INDICATED. FRONT SWALE STILL HOLDING WATER, BUT IT IS BEING HELD UP DOWNSTREAM WHERE IT IS HOLDING WATER AT THE ADJOINING PROPERTY CULVERT PIPE. APPROVING AS NOTED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 10/03/23 ELEVATION CORRECTIONS MADE ON SURVEY. WILL SEE IF IT WORKS IN THE FIELD. PASSING AS NOTED. ________________________________________________________________________________________________________________________ 8/24/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01c3 The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) Swale Plan #1 The finished swale elevation is with sod in place. THE ROAD SIDE SWALE IS HOLDING WATER FROM FLOWING. NEED TO GRADE ROAD SIDE SWALE SO IT MATCHES SWALE PLAN DETAIL. 3) Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation.
ROW - STORMWATER FINAL 10/05/2023 APPROVED - AS NOTED FSLADISH
Note: 10/05/23 AT THE TIME OF THIS INSPECTION EVERTHING MEETS COPC INPECTION MINIMUM REQUIREMENTS. BUILDER IS RESPONSIBLE FOR ANY CHANGES THAT MAY OCCUR AFTER THIS INSPECTION. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 10/03/23 UPON WALKING PROPERTY DRAINAGE APPEARS TO WORK AS INDICATED. FRONT SWALE STILL HOLDING WATER, BUT IT IS BEING HELD UP DOWNSTREAM WHERE IT IS HOLDING WATER AT THE ADJOINING PROPERTY CULVERT PIPE. APPROVING AS NOTED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 10/03/23 ELEVATION CORRECTIONS MADE ON SURVEY. WILL SEE IF IT WORKS IN THE FIELD. PASSING AS NOTED. ________________________________________________________________________________________________________________________ 8/24/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01c3 The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) Swale Plan #1 The finished swale elevation is with sod in place. THE ROAD SIDE SWALE IS HOLDING WATER FROM FLOWING. NEED TO GRADE ROAD SIDE SWALE SO IT MATCHES SWALE PLAN DETAIL. 3) Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation.
U -UTILITY RESIDENTIAL FINAL 10/05/2023 FINAL APPROVED JHARDING
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/03/2023 APPROVED - AS NOTED FSLADISH
Note: 10/03/23 ELEVATION CORRECTIONS MADE ON SURVEY. WILL SEE IF IT WORKS IN THE FIELD. PASSING AS NOTED. ________________________________________________________________________________________________________________________ 8/24/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01c3 The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) Swale Plan #1 The finished swale elevation is with sod in place. THE ROAD SIDE SWALE IS HOLDING WATER FROM FLOWING. NEED TO GRADE ROAD SIDE SWALE SO IT MATCHES SWALE PLAN DETAIL. 3) Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation.
ROW FIELD SURVEY /GRADING CERTIFICATION 10/03/2023 APPROVED - AS NOTED FSLADISH
Note: 10/03/23 UPON WALKING PROPERTY DRAINAGE APPEARS TO WORK AS INDICATED. FRONT SWALE STILL HOLDING WATER, BUT IT IS BEING HELD UP DOWNSTREAM WHERE IT IS HOLDING WATER AT THE ADJOINING PROPERTY CULVERT PIPE. APPROVING AS NOTED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 10/03/23 ELEVATION CORRECTIONS MADE ON SURVEY. WILL SEE IF IT WORKS IN THE FIELD. PASSING AS NOTED. ________________________________________________________________________________________________________________________ 8/24/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01c3 The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) Swale Plan #1 The finished swale elevation is with sod in place. THE ROAD SIDE SWALE IS HOLDING WATER FROM FLOWING. NEED TO GRADE ROAD SIDE SWALE SO IT MATCHES SWALE PLAN DETAIL. 3) Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation.
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/24/2023 Disapproved - NO FEE PFLANAGAN
Note: 1) Sec 300.01c3 The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) Swale Plan #1 The finished swale elevation is with sod in place. THE ROAD SIDE SWALE IS HOLDING WATER FROM FLOWING. NEED TO GRADE ROAD SIDE SWALE SO IT MATCHES SWALE PLAN DETAIL. 3) Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation.
ELECTRIC - EARLY POWER 02/07/2023 APPROVED JSTEWART
ROW- PRE-APRON (PRE-POUR) 01/04/2023 APPROVED PFLANAGAN
Note: IT'S THE CONTRACTORS RESPONSIBILITY TO CHECK THE CULVERT PIPE ELEVATIONS BEFORE POURING CONCRETE FOR THE DRIVEWAY.
U - SEWER TIE IN 12/15/2022 APPROVED - AS NOTED MGIBSON
Note: CONTACTED IVAN FROM UTILITIES DUE TO TAP BEING ROOT BOUND
GRAVITY SEWER TEST 12/15/2022 APPROVED MGIBSON
LATH/BRICK/ WATER BARRIER 10/05/2022 APPROVED BTAYLOR
INSULATION 09/26/2022 APPROVED BTAYLOR
ALL ROUGH 09/16/2022 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/10/2022 APPROVED BTAYLOR
ROOF VALLEY & METAL 06/03/2022 APPROVED TSTAUFFACHER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/13/2022 APPROVED DCUSHING
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/06/2022 CANCELLED BY APPLICANT WEB
TIE BEAM / LINTEL 04/07/2022 APPROVED TSTAUFFACHER
FOUND SURVEY APPROVED (OFFICE) 02/14/2022 APPROVED TDOAK
MONOLITHIC SLAB 01/24/2022 APPROVED TSTAUFFACHER
Note: THIS IS A REINSPECTION No compaction test posted Stopped at 8.18 AM and again at 11.30 AM
MONOLITHIC SLAB 01/19/2022 Disapproved - NO FEE TSTAUFFACHER
Note: No compaction test posted Stopped at 8.18 AM and again at 11.30 AM
PLUMBING 1ST ROUGH UNDERGROUND 01/11/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 12/28/2021 APPROVED CSTONE

Review History

Department Status Date In Date Out
BLD COMPLETE 05/10/2022 05/11/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM 5/11/2022 –Changed roof framing from truss to conventional framing: HA
BLD HOLD 03/30/2022 03/31/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Note on the drawing references Table R802.5.1 for Rafter Spans. The 2020 Florida Building Code Residential, the referenced Tables were removed. Revise to reference the current Tables. 2. Proposed 2 x 10 rafters appear over spanned per the 2018 Wood Frame Construction Manual. A revision is required. FC 107
BLD HOLD 03/15/2022 03/16/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Proposed 2 x 10 rafters appear over spanned per the 2018 Wood Frame Construction Manual. A revision is required. FC 107
ENGIN1 COMPLETE 02/14/2022 02/14/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/14/2022 02/14/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON COMPLETE 11/29/2021 11/30/2021
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON HOLD 11/23/2021 11/23/2021
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM I emailed the termination of easement agreement to you. Please have the owner sign and get notarized. Please turn the original in to us for recording and we can release the permit.
BLD COMPLETE 11/23/2021 11/24/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/23/2021 11/23/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 11/23/2021 11/30/2021
Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM
MECH COMPLETE 11/09/2021 11/09/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 11/09/2021 11/10/2021
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building Residential REVIEW COMMENTS: 1. OK 2. Roof sheathing is Grade #2 on sheets 3 and 5. Provide species of lumber to be used. 3. OK
ELEC COMPLETE 11/09/2021 11/09/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON HOLD 11/09/2021 11/09/2021
Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Walk way : where walk way meets circular driveway, it can not excced 6 ft. please modify Recieved paperwork for termination of easement once agreement is completed We will email for owners to sign and notarize. Once completed please return all origninals.
ENGIN1 COMPLETE 11/09/2021 11/09/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 11/09/2021 11/17/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM
LOCATE COMPLETE 11/09/2021 11/16/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
SWALE COMPLETE 09/23/2021 11/30/2021
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/23/2021 09/23/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 09/21/2021 09/22/2021
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building Residential REVIEW COMMENTS: 1. Provide a completed City of palm Coast Roofing Worksheet. 2. Provide species of lumber to be used. 3. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 13/8 inches (35 mm) in thickness, solid or honeycombcore steel doors not less than 13/8 inches (35 mm) thick, or 20-minute fire-rated doors.
CUSVC COMPLETE 09/21/2021 09/24/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 09/21/2021 09/22/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit electric load calcs
ENGIN1 HOLD 09/21/2021 09/22/2021
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM No survey in submittal package
LOCATE COMPLETE 09/21/2021 09/28/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 09/21/2021 09/22/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Plans show R38 insulation in attic with vented soffit. Energy calcs say R20 on roof deck with non vented soffit. Revise to match
SW1 COMPLETE 09/21/2021 09/29/2021
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON HOLD 09/21/2021 09/23/2021
Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Site Plan: please provide the width of of the entry walk way. Please know that the walkway may not exceed 6 ft. Landscape plan: is missing please provide. Termination of easement missing: Please provide a Termination of Easement application and provide the letters from utility company releasing easment and a survey of the property with easement on survey. After recieving that we will create an agreement for all owners of property to sign and notarize and start the process.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 10/04/2023
EXTENSION ¤40.00 10/04/2023
PLAN REVIEW - REVISION ¤32.50 10/04/2023
CONNECTION FEES ¤1,017.83 12/13/2021
INSPECTION - RESIDENTIAL ¤819.50 12/13/2021
PLAN REVIEW - RESIDENTIAL ¤232.44 12/13/2021
METER - DEPOSIT ¤60.00 12/13/2021
WATER- TURN ON ¤25.00 12/13/2021
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/13/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 12/13/2021
IMPACT FEE FIRE ¤367.00 12/13/2021
IMPACT FEE PARKS ¤1,199.12 12/13/2021
IMPACT FEE SCHOOL ¤3,600.00 12/13/2021
RECORDING FEE REIMBURSE DOC ¤35.50 12/13/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 12/13/2021
WATER -IRRIGATION INSPECTION ¤25.00 12/13/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 12/13/2021
SURCHARGE FS 533.721 ¤11.40 12/13/2021
SURCHARGE - FS 468.631 ¤17.11 12/13/2021
SW ENG - FOUNDATION SURVEY ¤20.00 12/13/2021
SW ENG INSPECTION 60 ¤60.00 12/13/2021
SW ENG PRE APRON ¤30.00 12/13/2021
SW ENG - REVIEW 20 ¤20.00 12/13/2021
SW ENG RES REVIEW 200 ¤200.00 12/13/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 12/13/2021
SEWER CREDIT (¤1,342.00) 12/13/2021
SEWER INSPECTION ¤25.00 12/13/2021
SEWER CAPITAL FACILITY ¤4,664.55 12/13/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 12/13/2021
SITE PLAN 30 ¤30.00 12/13/2021
Fees Total Due: ¤0.00 Total Paid: ¤16,283.88