Permit #2021091192
Permit Details
Status: COED
| Parcel Id: 08-12-31-5845-00000-0020 |
| Total Square Footage: 55071 sqft |
| Block: 00000 |
| Subdivision: - |
| Job Phone: 321-723-5661 |
| Location Address: 5622 STATE HWY 100 E |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 07/25/2022 |
| NOC: RECORDED |
| Applicant name: GARY HOWELL II NEAL |
| Owner: SKUSA PALM COAST LLC |
|
Address C/O ANDOVER PROPERTIES LLC NEW YORK, NY 10022 |
|
Address 32nd FLOOR NEW YORK, NY 10022 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤2,500,000.00 |
| Job Description: BUILDING A - SELF STORAGE 49,515 SQ FT |
| Type: CN |
Contractor
M E CONSTRUCTION INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
445 PINEDA CT MELBOURNE, FL 32940 |
CGC1525425 (Exp: 08/31/2026) | 321-723-5661 |
Sub Contractors
FERNANDO DE ARMAS
| Status | Location Address | State License Number | Phone |
| INACTIVE |
6163 47TH STREET E , 0 |
CAC1817280 (Exp: 08/31/2024) | 941-241-6689 |
MICHAEL KELLEY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
5037 CRILL AVE PALATKA, FL 32177 |
EC13012806 (Exp: 08/31/2026) | 904-808-3192 |
ORLANDO GONZALEZ
| Status | Location Address | State License Number |
| INACTIVE |
17501 NW 47TH CT MIAMI GARDENS, FL 33055 |
CFC1432809 (Exp: 08/31/2026) |
Inspection History
| Type | Request Date | Result | Inspector |
| PLUMBING FINAL | 06/21/2024 | APPROVED | MGIBSON |
| Note: 6/20/2024 - PREVIOUS INSPECTION NOTES NEED VACUUME BREAKERS ON ALL HOSE BIBS, NEED ANTISYPHONE DEVICE AT BOTTOM FEED WATER HEATER, AND ESSCUSIONS ON ALL WALL AND CABINET PENITRATIONS, AND NEED TO HAVE C/O COVER IN PLACE WHERE ''ADA'' BATHROOM IS ON ''B'' UNIT AND WALL COVER PLATE INSTALLED | |||
| PLUMBING FINAL | 06/20/2024 | Disapproved - NO FEE | MGIBSON |
| Note: NEED VACUUME BREAKERS ON ALL HOSE BIBS, NEED ANTISYPHONE DEVICE AT BOTTOM FEED WATER HEATER, AND ESSCUSIONS ON ALL WALL AND CABINET PENITRATIONS, AND NEED TO HAVE C/O COVER IN PLACE WHERE ''ADA'' BATHROOM IS ON ''B'' UNIT AND WALL COVER PLATE INSTALLED | |||
| FIRE FINAL | 06/17/2024 | APPROVED | RMARTIN |
| U - UTILITY COMMERCIAL FINAL | 06/14/2024 | FINAL APPROVED | LFITZGERALD |
| BUILDING FINAL | 06/12/2024 | APPROVED - AS NOTED | FWILLIS |
| Note: PENDING PLUMBING AND FIRE FINAL. | |||
| EXTERIOR ARCHITECTURAL FEATURES | 06/12/2024 | APPROVED | RPICATAGI |
| ROOF SHEATHING / BRACE / TIE DOWN | 06/12/2024 | APPROVED | FWILLIS |
| Note: 11/21/2023 - PREVIOUS INSPECTION NOTES NEED TO DISCUSS WHAT NEEDS TO BE VIEWED AND WHAT HAS BEEN VIEWED. WILL GET WITH ROBERT. | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 06/12/2024 | FINAL APPROVED | FWILLIS |
| Note: 2/28/2023 - PREVIOUS INSPECTION NOTES wrong inspection tie beam needed, tie beam inspection added and resulted | |||
| ELECTRIC FINAL | 06/10/2024 | APPROVED | RMARTIN |
| Note: 6/6/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 6/6/2024 11:02:28 AM *** NEED TO LABEL AIR HANDLERS WITH CORRECT MOCP, NEED TO HAVE TAMPER PROOF OULETS IN LOBBY AREA, MAKE SURE PANEL SCHEDULE MATCHES APPROVED PLANS Inspector Notes from Inspection 3210 WILL NEED TO KEEP MAINS AND BREAKERS LOCKED OUT UNTIL CIRCUITS ARE READY TO BE ENERGIZED | |||
| FOOTER | 06/07/2024 | CANCELLED BY INSPECTOR | FWILLIS |
| HVAC FINAL | 06/07/2024 | FINAL APPROVED | CPISCITELLI |
| FRAMING | 06/07/2024 | CANCELLED BY INSPECTOR | FWILLIS |
| Note: 2/8/2024 - PREVIOUS INSPECTION NOTES | |||
| INSULATION | 06/07/2024 | CANCELLED BY INSPECTOR | FWILLIS |
| ELECTRIC FINAL | 06/06/2024 | Disapproved - NO FEE | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 6/6/2024 11:02:28 AM *** NEED TO LABEL AIR HANDLERS WITH CORRECT MOCP, NEED TO HAVE TAMPER PROOF OULETS IN LOBBY AREA, MAKE SURE PANEL SCHEDULE MATCHES APPROVED PLANS Inspector Notes from Inspection 3210 WILL NEED TO KEEP MAINS AND BREAKERS LOCKED OUT UNTIL CIRCUITS ARE READY TO BE ENERGIZED | |||
| HVAC FINAL | 06/06/2024 | Disapproved - NO FEE | CPISCITELLI |
| Note: 1. Need to have heater stickers on AHUs. Could not verify breakers 2. Need tostrap exhaust duct in janitors closet. 3. Need to repair insulation of fresh air duct in two locations 4. Need to strap line set in back area AHU5. Repair missing straps on all drains and copper linesets | |||
| ABOVE CEILING | 05/30/2024 | APPROVED | CPISCITELLI |
| Note: 5/23/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY CPISCITELLI 5/23/2024 3:36:58 PM *** 6. Missing balancing dampers *** NOTES ADDED BY CPISCITELLI 5/23/2024 3:36:07 PM *** 1. Need to put hose clamp on barb fitting for minisplit condensate 2. Need to support flex lines in several locations 3. Need to use proper straps for minisplit lineset 4. minisplit condensate needs to be trapped or check valve before pump 5. Need to support exhaust duct in bathrooms and fasten duct to fans with screws Mechanical notes from 4/18/24 1. Need to support fresh air boxes, remove tape and use proper material to seal annular space around boxes 2. Condensate line for minisplit not installed 3. Several supply plenums need to be cut back as to not touch the sprinkler pipes | |||
| ABOVE CEILING | 05/23/2024 | Disapproved - NO FEE | CPISCITELLI |
| Note: *** NOTES ADDED BY CPISCITELLI 5/23/2024 3:36:58 PM *** 6. Missing balancing dampers *** NOTES ADDED BY CPISCITELLI 5/23/2024 3:36:07 PM *** 1. Need to put hose clamp on barb fitting for minisplit condensate 2. Need to support flex lines in several locations 3. Need to use proper straps for minisplit lineset 4. minisplit condensate needs to be trapped or check valve before pump 5. Need to support exhaust duct in bathrooms and fasten duct to fans with screws Mechanical notes from 4/18/24 1. Need to support fresh air boxes, remove tape and use proper material to seal annular space around boxes 2. Condensate line for minisplit not installed 3. Several supply plenums need to be cut back as to not touch the sprinkler pipes | |||
| FIREWALL NAILING | 05/08/2024 | APPROVED | FWILLIS |
| Note: Firewall Inspection 3/15/2024 - PREVIOUS INSPECTION NOTES Sprinkler room walls are approved. Highlighted plans. Ceiling not yet framed. | |||
| HVAC ROUGH | 04/18/2024 | APPROVED | CPISCITELLI |
| Note: 3/8/2024 - PREVIOUS INSPECTION NOTES 1. Need to support fresh air boxes, remove tape and use proper material to seal annular space around boxes 2. Condensate line for minisplit not installed 3. AHU 9 not installed 4. Seams not inspected prior to wrap need to meet on site to remove wrap for seam inspection 5. One AHU too close to electrical juction box. Box not accessible 6. Several supply plenums need to be cut back as to not touch the sprinkler pipes | |||
| ELECTRIC - EARLY POWER | 04/18/2024 | APPROVED - AS NOTED | RMARTIN |
| Note: WILL NEED TO KEEP MAINS AND BREAKERS LOCKED OUT UNTIL CIRCUITS ARE READY TO BE ENERGIZED | |||
| FIREWALL NAILING | 03/15/2024 | PARTIALLY APPROVED | JWALKER |
| Note: Sprinkler room walls are approved. Highlighted plans. Ceiling not yet framed. | |||
| FIREWALL NAILING | 03/13/2024 | APPROVED | FWILLIS |
| FIREWALL NAILING | 03/12/2024 | APPROVED | FWILLIS |
| HVAC ROUGH | 03/08/2024 | Disapproved - NO FEE | CPISCITELLI |
| Note: 1. Need to support fresh air boxes, remove tape and use proper material to seal annular space around boxes 2. Condensate line for minisplit not installed 3. AHU 9 not installed 4. Seams not inspected prior to wrap need to meet on site to remove wrap for seam inspection 5. One AHU too close to electrical juction box. Box not accessible 6. Several supply plenums need to be cut back as to not touch the sprinkler pipes | |||
| PLUMBING 2ND ROUGH | 03/08/2024 | APPROVED | MGIBSON |
| Note: 3/7/2024 - PREVIOUS INSPECTION NOTES 2/23/2024 - PREVIOUS INSPECTION NOTES NEED TO INSTALL 2 ICEMACKER BOXES WITH SHOCK ARRESSTORS AT BOTH FRIDGE AREAS AND MID STORY STRAPS AT 3'' AND 2'' VENTS IN BATHROOM STILL NO NAIL PLATES, AND WRONG ICE-MAKER BOXES PLUMBERS HAVE A FIX FOR ICEMAKER BOXES AND NAIL PLATES ARE IN PLACE | |||
| BLD - SEWER TIE IN | 03/08/2024 | CANCELLED BY APPLICANT | MRAMOS |
| PLUMBING 2ND ROUGH | 03/07/2024 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: 2/23/2024 - PREVIOUS INSPECTION NOTES NEED TO INSTALL 2 ICEMACKER BOXES WITH SHOCK ARRESSTORS AT BOTH FRIDGE AREAS AND MID STORY STRAPS AT 3'' AND 2'' VENTS IN BATHROOM STILL NO NAIL PLATES, AND WRONG ICE-MAKER BOXES | |||
| FIREWALL NAILING | 02/28/2024 | APPROVED | FWILLIS |
| Note: 2/5/2024 - PREVIOUS INSPECTION NOTES 2/5/24 Please have the approved plans onsite for all inspections. | |||
| PLUMBING 2ND ROUGH | 02/23/2024 | PARTIALLY APPROVED | MGIBSON |
| Note: NEED TO INSTALL 2 ICEMACKER BOXES WITH SHOCK ARRESSTORS AT BOTH FRIDGE AREAS AND MID STORY STRAPS AT 3'' AND 2'' VENTS IN BATHROOM | |||
| FRAMING | 02/22/2024 | APPROVED | FWILLIS |
| Note: 2/5/2024 - PREVIOUS INSPECTION NOTES 2/5/24 Please have the approved set of plans onsite for all inspections. 11/15/2023 - PREVIOUS INSPECTION NOTES 11/15/23 - PARTIAL. NOT THE OFFICE. 6/14/2023 - PREVIOUS INSPECTION NOTES BUILDING "A" NOT INCLUDING THE OFFICE. ALSO DOORS ON UNITS WILL BE INSTALLED AT A FUTURE DATE. APPROVED PLANS PAGES S200 AND S201. | |||
| FRAMING | 02/08/2024 | CANCELLED BY APPLICANT | FWILLIS |
| STOREFRONT | 02/08/2024 | APPROVED | FWILLIS |
| FIREWALL NAILING | 02/05/2024 | Disapproved - NO FEE | JWALKER |
| Note: 2/5/24 Please have the approved plans onsite for all inspections. | |||
| FRAMING | 02/05/2024 | Disapproved - NO FEE | JWALKER |
| Note: 2/5/24 Please have the approved set of plans onsite for all inspections. 11/15/2023 - PREVIOUS INSPECTION NOTES 11/15/23 - PARTIAL. NOT THE OFFICE. 6/14/2023 - PREVIOUS INSPECTION NOTES BUILDING "A" NOT INCLUDING THE OFFICE. ALSO DOORS ON UNITS WILL BE INSTALLED AT A FUTURE DATE. APPROVED PLANS PAGES S200 AND S201. | |||
| ELECTRIC 2ND ROUGH | 11/22/2023 | APPROVED | RMARTIN |
| ROOF SHEATHING / BRACE / TIE DOWN | 11/21/2023 | CANCELLED BY APPLICANT | FWILLIS |
| Note: NEED TO DISCUSS WHAT NEEDS TO BE VIEWED AND WHAT HAS BEEN VIEWED. WILL GET WITH ROBERT. | |||
| FRAMING | 11/15/2023 | PARTIALLY APPROVED | FWILLIS |
| Note: 11/15/23 - PARTIAL. NOT THE OFFICE. 6/14/2023 - PREVIOUS INSPECTION NOTES BUILDING "A" NOT INCLUDING THE OFFICE. ALSO DOORS ON UNITS WILL BE INSTALLED AT A FUTURE DATE. APPROVED PLANS PAGES S200 AND S201. | |||
| STOREFRONT | 11/03/2023 | APPROVED | FWILLIS |
| Note: 11/3/23 - UPPER FLOOR 11/2/2023 - PREVIOUS INSPECTION NOTES 11/2/23 Lower store front only. 10/27/2023 - PREVIOUS INSPECTION NOTES STOREFRONT SILL ONLY | |||
| STOREFRONT | 11/02/2023 | PARTIALLY APPROVED | JWALKER |
| Note: 11/2/23 Lower store front only. 10/27/2023 - PREVIOUS INSPECTION NOTES STOREFRONT SILL ONLY | |||
| STOREFRONT | 10/27/2023 | PARTIALLY APPROVED | FWILLIS |
| Note: STOREFRONT SILL ONLY | |||
| FRAMING | 06/14/2023 | PARTIALLY APPROVED | FWILLIS |
| Note: BUILDING "A" NOT INCLUDING THE OFFICE. ALSO DOORS ON UNITS WILL BE INSTALLED AT A FUTURE DATE. APPROVED PLANS PAGES S200 AND S201. | |||
| FOUNDATION SURVEY - OFFICE USE ONLY | 04/19/2023 | APPROVED | DLEAP |
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 02/28/2023 | CANCELLED BY APPLICANT | LMILLER |
| Note: wrong inspection tie beam needed, tie beam inspection added and resulted | |||
| TIE BEAM | 02/28/2023 | APPROVED | LMILLER |
| Note: inspection for Dumpster coral only | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 01/25/2023 | APPROVED | LMILLER |
| Note: 1/17/2023 - PREVIOUS INSPECTION NOTES Clearance on reinforcing bars per TABLE 1808.8.2 MINIMUM CONCRETE COVER not met 1-25-23 notes above resolved | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 01/17/2023 | Disapproved -FEE REQUIRED | LMILLER |
| Note: Clearance on reinforcing bars per TABLE 1808.8.2 MINIMUM CONCRETE COVER not met | |||
| MONOLITHIC SLAB | 11/08/2022 | APPROVED | DCUSHING |
| Note: 10/24/2022 - PREVIOUS INSPECTION NOTES Main section of Bldg A | |||
| ASPHALT STRIPING | 11/07/2022 | CANCELLED BY APPLICANT | WEB |
| MONOLITHIC SLAB | 10/24/2022 | PARTIALLY APPROVED | DCUSHING |
| Note: Main section of Bldg A | |||
| PLUMBING 1ST ROUGH | 10/19/2022 | APPROVED | MGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 06/20/2024 | 06/20/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/14/2024 | 06/18/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Documents rejected. Already uploaded to BDA permit and approved | |||
| FI1 | COMPLETE | 06/14/2024 | 06/18/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Documents rejected. Already uploaded to BDA permit and approved | |||
| FI1 | COMPLETE | 05/13/2024 | 05/28/2024 |
| Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/11/2024 | 04/19/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/01/2024 | 04/02/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/19/2024 | 04/01/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/19/2024 | 03/25/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide hanging detail for AHU new location | |||
| BADMIN | INFORMATION | 03/13/2024 | 03/13/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Documents/Files named incorrectly o Please rename your files in accordance with the naming convention outlined in our ‘document requirements’ located on the permit portal page http://docs.palmcoastgov.com/departments/building/online/document-requirements.pdf o It is important that all submittals follow the guidelines for efficient plan review and record retention accuracy. o You may add to your file name AFTER the above naming convention has been met. Examples Document type: Plans File name : Given sheet name A.1 / Plans Document type: Foundation Survey File name: Foundation Survey Document type: Manufactures Specifications File Name: Pool Alarm Document type: Manufactures Specifications File Name: Generator Revisions and corrections should follow the same criteria and should use the same name as the original originally identified. (no – new, revised, second submittal, updated) | |||
| ELEC | COMPLETE | 01/12/2024 | 01/19/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/25/2023 | 06/08/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 05/24/2023 | 05/24/2023 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM Plans missing digital signature. | |||
| BLD | HOLD | 05/24/2023 | 05/24/2023 |
| Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM SIGNATURE NOT VERIFIED | |||
| BADMIN | INFORMATION | 05/17/2023 | 05/17/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Documents uploaded are to be uploaded as separate pages and the files named in accordance with the file naming convention located on the 'document submittal requirements' located on the permitting portal. The file names should be consistent with the original file names. | |||
| PLENG | COMPLETE | 04/18/2023 | 04/18/2023 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 03/31/2023 | 03/31/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM You uploaded under elevation certificate a document named foundation survey. Those are two different review departments. Please correct/clarify the correct submittal. (change file name or change document type) | |||
| PLENG | HOLD | 03/31/2023 | 04/03/2023 |
| Note: Held By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM Label plan as "Foundation Survey". The plan is currently labelled as a Topographic Survey. | |||
| DSD | COMPLETE | 03/31/2023 | 03/31/2023 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 07/11/2022 | 07/11/2022 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM We received check 001023 in the amount $188.269.15. However the amount due $188.269.16. We are unable to process this payment. | |||
| FI1 | COMPLETE | 05/18/2022 | 05/20/2022 |
| Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/18/2022 | 05/25/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/06/2022 | 05/06/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| FI1 | HOLD | 05/06/2022 | 05/13/2022 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please show location of responses in a response letter and provide clouded response changes The following is still needed. (the areas accessed by the exterior only will need to have coverage met with extinguisher within site, extinguishers inside will not meet the requirement) 1. per NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. The maximum travel distance must be calculated per FFPC 1, chapter 6 tables 6.2.1.1 and 6.3.1.1 Please show the Extinguisher size used for calculating travel distance (provide sheet number) and show the calculations. (several areas of coverage are still needed) | |||
| BLD | COMPLETE | 03/29/2022 | 04/05/2022 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| FI1 | HOLD | 03/29/2022 | 04/11/2022 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please show location of responses in a response letter and provide clouded response changes The following is still needed.... 1. The following is still needed. per NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. The maximum travel distance must be calculated per FFPC 1, chapter 6 tables 6.2.1.1 and 6.3.1.1 Please show the Extinguisher size used for calculating travel distance (provide sheet number) and show the calculations. (several areas of coverage are still needed) | |||
| MECH | HOLD | 03/29/2022 | 03/30/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Revise equipment schedule to correspond with heatload calculation. Tonnages are not correlating. (Spoke to architect) | |||
| MECH | HOLD | 01/19/2022 | 01/20/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Revise equipment schedule to correspond with heatload calculation. Tonnages are not correlating. 2. Provide heatload on seperate letter or plans. Not on response letter. (Second Request) | |||
| PLUM | COMPLETE | 01/19/2022 | 01/20/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/19/2022 | 01/20/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Repeat comment item 4 from previous hold comments: 4. Various Product Approvals submitted are either outdated or incorrect. A revision to the Product Approvals is required. Per F.S. 471.025 and F.A.C. 61 G15-23.005. a. 15-0127.05 is outdated. b. Metal Wall Panels Product Approval does not match the Product Approval Sheet. c. Glass sliding doors Product Approval does not match the Product Approval Sheet. d. Egress doors Product Approval does not match the Product Approval Sheet. Note: Submitted correction for the above item still unclear. Some FL Numbers on Product Approval Specification Sheet does not match with those FL Numbers shown on Drawing Sheet T- 001.00. Please coordinate for clarity. Cut sheets are not a substitute to the product approval numbers. | |||
| FI1 | HOLD | 01/19/2022 | 01/25/2022 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please show location of responses in a response letter and provide clouded response changes The following is still needed... 1. Digital seals need to be live on all documents 2. The following is still needed. per NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. The maximum travel distance must be calculated per FFPC 1, chapter 6 tables 6.2.1.1 and 6.3.1.1 Please show the Extinguisher size used for calculating travel distance (provide sheet number) and show the calculations. | |||
| MECH | HOLD | 12/10/2021 | 12/14/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Revise equipment schedule to correspond with heatload calculation. Tonnages are not correlating. 2. Provide heatload on seperate letter or plans. Not on response letter. | |||
| PLUM | HOLD | 12/10/2021 | 12/17/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Comments from previous hold: 1. OK.. 2. Keyed Notes on Sheet P-101.01, Enlarged Pressure Plan. One note is shown with an X. A revision to the Notes to provide what is called-out with the X. | |||
| BLD | HOLD | 12/10/2021 | 12/17/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comment item 4 from previous hold comments: . 4. Various Product Approvals submitted are either outdated or incorrect. A revision to the Product Approvals is required. Per F.S. 471.025 and F.A.C. 61 G15-23.005. Note : Submitted correction for the above item still unclear. Some FL Numbers on Product Approval Specification Sheet does not match with those FL Numbers shown on Drawing Sheet T- 001.00. Please coordinate for clarity. | |||
| FI1 | HOLD | 12/10/2021 | 12/27/2021 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM 1. Digital seals need to be live on all documents 2. The following is still needed. per NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. The maximum travel distance must be calculated per FFPC 1, chapter 6 tables 6.2.1.1 and 6.3.1.1 Please show the Extinguisher size used for calculating travel distance (provide sheet number) and show the calculations. | |||
| ARCHR | COMPLETE | 09/27/2021 | 10/08/2021 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/27/2021 | 10/06/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building PLAN REVIEW COMMENTS: 1. Provide complete copy of Geotechnical Investigation Report signed and sealed by a Florida licensed professional engineer. It appears a geotechnical investigation report was not included with the civil plans under the Commercial Site Development Permit. 2. Applicable Building Codes referenced on sheet T-001.00 are not the current Code referenced. As of January 1, 2021, Florida State adopted the 2020 Florida Building Code 7th Edition. 3. Following Comments are from sheet A-010.00; a) As mentioned above, the Code reference is incorrect. b) Florida State does not have State Supplement c) Interior Environment and Chapter 15 reference the 2014 FBC. d) The Florida Building Code and the NFPA Standard was used for the Code Analysis of the proposed building. Per Section 102.4, 2020 Florida Building Code. The most restrictive is to be used. The Building Code is more restrictive and shall be used for the Code Analysis. 4. Various Product Approvals submitted are either outdated or incorrect. A revision to the Product Approvals is required. Per F.S. 471.025 and F.A.C. 61 G15-23.005. | |||
| DSD | COMPLETE | 09/27/2021 | 10/08/2021 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 09/27/2021 | 10/04/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| FI1 | HOLD | 09/27/2021 | 10/11/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Please show location of responses in a response letter and provide clouded response changes Need separate permits for Fire Underground per FFPC, NFPA 1, Fire Code section 1.12.8 Need separate permits for Fire alarms and detection systems and related equipment per FFPC, NFPA 1, Fire Code section 1.12.8 1. Please place the following notes on the Title Page T-001.00 2. Need separate permits for Automatic fire sprinkler systems per FFPC, NFPA 1, Fire Code section 1.12.8 3. Applicable Fire Codes referenced on sheet T-001.00 and A-010.00 are not the current Code referenced. Please list FFPC 2020 7th Edition for review. 4. FP-100.00 is listed on the Title page as the Fire protection site plan and is not provided. 5. Please rename Egress plan to Life safety Plan and show on cover sheet. 6. Please provide information on the knox box for rapid entry access of fire department per NFPA 1, 18.2.2.2, FFPC 1 - 18.2.3.4.1.2 and AHJ. And place the following on the cover sheet: Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes 7. Please note, storz/locking caps (not allowed per ahj). Please provide notes for standard fire department threads on fdc per ahj 8. Please revise FDC detail to reflect the changes on sheet FP-201.00 9. Please identify Class of Hazard per FBC 2020 7th edition Chapter 9, 906.3, 906.3.1, 906.3.2, 906,3.3, 906.3.4 10. Please see NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the number of and maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. 11. Please show location of required extinguishers on Life Safety Plan and place per FBC 2020 7th edition chapter 9, 906.5 and 906.6 including areas accessed only from the exterior. 12. Need to know the height of the covered loading area (define minimum clearance height) | |||
| PLUM | HOLD | 09/27/2021 | 10/06/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Plumbing PLAN REVIEW COMMENTS: 1. Provide complete copy of Geotechnical Investigation Report signed and sealed by a Florida licensed professional engineer. It appears a geotechnical investigation report was not included with the civil plans under the Commercial Site Development Permit. 2. Keyed Notes on Sheet P-101.01, Enlarged Pressure Plan. One note is shown with an X. A revision to the Notes to provide what is called-out with the X. | |||
| UD1 | COMPLETE | 09/27/2021 | 09/28/2021 |
| Note: Released By: CHRIS JOHNSON - - CJOHNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 09/27/2021 | 10/04/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM This is correct review. It was completed by mistake. 1. Need to reference 7Th edition for all Building codes 2. Provide heatload calculation per C403.2.1 FBC Energy Conservation 2020 7Th edition |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 06/17/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 06/17/2024 |
| REINSPECTION - COMMERCIAL | ¤60.00 | 06/17/2024 |
| REINSPECTION - COMMERCIAL | ¤60.00 | 06/17/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 06/17/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 06/17/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 06/17/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 06/17/2024 |
| 3% FIRE IMPACT FEE CREDIT | (¤2,931.40) | 07/25/2022 |
| IMPACT FEE FIRE | ¤97,713.44 | 07/25/2022 |
| IMPACT FEE TRANSPORTATION | ¤74,692.82 | 07/25/2022 |
| SURCHARGE FS 533.721 | ¤204.80 | 07/25/2022 |
| SURCHARGE - FS 468.631 | ¤310.27 | 07/25/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤2,240.78) | 07/25/2022 |
| SITE PLAN 30 | ¤30.00 | 07/25/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 07/25/2022 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 07/25/2022 |
| INSPECTION COMMERCIAL | ¤17,500.00 | 07/25/2022 |
| PLAN REVIEW - COMMERCIAL | ¤2,875.00 | 07/25/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤188,534.15 |