Permit #2021091192

Permit Details

Status: COED

Parcel Id: 08-12-31-5845-00000-0020
Total Square Footage: 55071 sqft
Block: 00000
Subdivision: -
Job Phone: 321-723-5661
Location Address: 5622 STATE HWY 100 E
Type: BC - BUILDING COMMERCIAL
Issue Date: 07/25/2022
NOC: RECORDED
Applicant name: GARY HOWELL II NEAL
Owner: SKUSA PALM COAST LLC

Address

C/O ANDOVER PROPERTIES LLC

NEW YORK, NY 10022

Address

32nd FLOOR

NEW YORK, NY 10022

Lot: 0020
Contracted Stated Job Value: ¤2,500,000.00
Job Description: BUILDING A - SELF STORAGE 49,515 SQ FT
Type: CN

Contractor

M E CONSTRUCTION INC
Status Location Address State License Number Phone
ACTIVE

445 PINEDA CT

MELBOURNE, FL 32940

CGC1525425 (Exp: 08/31/2026) 321-723-5661

Sub Contractors

FERNANDO DE ARMAS
Status Location Address State License Number Phone
INACTIVE

6163 47TH STREET E

, 0

CAC1817280 (Exp: 08/31/2024) 941-241-6689
MICHAEL KELLEY
Status Location Address State License Number Phone
ACTIVE

5037 CRILL AVE

PALATKA, FL 32177

EC13012806 (Exp: 08/31/2026) 904-808-3192
ORLANDO GONZALEZ
Status Location Address State License Number
INACTIVE

17501 NW 47TH CT

MIAMI GARDENS, FL 33055

CFC1432809 (Exp: 08/31/2026)

Inspection History

Type Request Date Result Inspector
PLUMBING FINAL 06/21/2024 APPROVED MGIBSON
Note: 6/20/2024 - PREVIOUS INSPECTION NOTES NEED VACUUME BREAKERS ON ALL HOSE BIBS, NEED ANTISYPHONE DEVICE AT BOTTOM FEED WATER HEATER, AND ESSCUSIONS ON ALL WALL AND CABINET PENITRATIONS, AND NEED TO HAVE C/O COVER IN PLACE WHERE ''ADA'' BATHROOM IS ON ''B'' UNIT AND WALL COVER PLATE INSTALLED
PLUMBING FINAL 06/20/2024 Disapproved - NO FEE MGIBSON
Note: NEED VACUUME BREAKERS ON ALL HOSE BIBS, NEED ANTISYPHONE DEVICE AT BOTTOM FEED WATER HEATER, AND ESSCUSIONS ON ALL WALL AND CABINET PENITRATIONS, AND NEED TO HAVE C/O COVER IN PLACE WHERE ''ADA'' BATHROOM IS ON ''B'' UNIT AND WALL COVER PLATE INSTALLED
FIRE FINAL 06/17/2024 APPROVED RMARTIN
U - UTILITY COMMERCIAL FINAL 06/14/2024 FINAL APPROVED LFITZGERALD
BUILDING FINAL 06/12/2024 APPROVED - AS NOTED FWILLIS
Note: PENDING PLUMBING AND FIRE FINAL.
EXTERIOR ARCHITECTURAL FEATURES 06/12/2024 APPROVED RPICATAGI
ROOF SHEATHING / BRACE / TIE DOWN 06/12/2024 APPROVED FWILLIS
Note: 11/21/2023 - PREVIOUS INSPECTION NOTES NEED TO DISCUSS WHAT NEEDS TO BE VIEWED AND WHAT HAS BEEN VIEWED. WILL GET WITH ROBERT.
BLD - SITE STRUCTURE - TRASH DUMPSTER 06/12/2024 FINAL APPROVED FWILLIS
Note: 2/28/2023 - PREVIOUS INSPECTION NOTES wrong inspection tie beam needed, tie beam inspection added and resulted
ELECTRIC FINAL 06/10/2024 APPROVED RMARTIN
Note: 6/6/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 6/6/2024 11:02:28 AM *** NEED TO LABEL AIR HANDLERS WITH CORRECT MOCP, NEED TO HAVE TAMPER PROOF OULETS IN LOBBY AREA, MAKE SURE PANEL SCHEDULE MATCHES APPROVED PLANS Inspector Notes from Inspection 3210 WILL NEED TO KEEP MAINS AND BREAKERS LOCKED OUT UNTIL CIRCUITS ARE READY TO BE ENERGIZED
FOOTER 06/07/2024 CANCELLED BY INSPECTOR FWILLIS
HVAC FINAL 06/07/2024 FINAL APPROVED CPISCITELLI
FRAMING 06/07/2024 CANCELLED BY INSPECTOR FWILLIS
Note: 2/8/2024 - PREVIOUS INSPECTION NOTES
INSULATION 06/07/2024 CANCELLED BY INSPECTOR FWILLIS
ELECTRIC FINAL 06/06/2024 Disapproved - NO FEE RMARTIN
Note: *** NOTES ADDED BY RMARTIN 6/6/2024 11:02:28 AM *** NEED TO LABEL AIR HANDLERS WITH CORRECT MOCP, NEED TO HAVE TAMPER PROOF OULETS IN LOBBY AREA, MAKE SURE PANEL SCHEDULE MATCHES APPROVED PLANS Inspector Notes from Inspection 3210 WILL NEED TO KEEP MAINS AND BREAKERS LOCKED OUT UNTIL CIRCUITS ARE READY TO BE ENERGIZED
HVAC FINAL 06/06/2024 Disapproved - NO FEE CPISCITELLI
Note: 1. Need to have heater stickers on AHUs. Could not verify breakers 2. Need tostrap exhaust duct in janitors closet. 3. Need to repair insulation of fresh air duct in two locations 4. Need to strap line set in back area AHU5. Repair missing straps on all drains and copper linesets
ABOVE CEILING 05/30/2024 APPROVED CPISCITELLI
Note: 5/23/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY CPISCITELLI 5/23/2024 3:36:58 PM *** 6. Missing balancing dampers *** NOTES ADDED BY CPISCITELLI 5/23/2024 3:36:07 PM *** 1. Need to put hose clamp on barb fitting for minisplit condensate 2. Need to support flex lines in several locations 3. Need to use proper straps for minisplit lineset 4. minisplit condensate needs to be trapped or check valve before pump 5. Need to support exhaust duct in bathrooms and fasten duct to fans with screws Mechanical notes from 4/18/24 1. Need to support fresh air boxes, remove tape and use proper material to seal annular space around boxes 2. Condensate line for minisplit not installed 3. Several supply plenums need to be cut back as to not touch the sprinkler pipes
ABOVE CEILING 05/23/2024 Disapproved - NO FEE CPISCITELLI
Note: *** NOTES ADDED BY CPISCITELLI 5/23/2024 3:36:58 PM *** 6. Missing balancing dampers *** NOTES ADDED BY CPISCITELLI 5/23/2024 3:36:07 PM *** 1. Need to put hose clamp on barb fitting for minisplit condensate 2. Need to support flex lines in several locations 3. Need to use proper straps for minisplit lineset 4. minisplit condensate needs to be trapped or check valve before pump 5. Need to support exhaust duct in bathrooms and fasten duct to fans with screws Mechanical notes from 4/18/24 1. Need to support fresh air boxes, remove tape and use proper material to seal annular space around boxes 2. Condensate line for minisplit not installed 3. Several supply plenums need to be cut back as to not touch the sprinkler pipes
FIREWALL NAILING 05/08/2024 APPROVED FWILLIS
Note: Firewall Inspection 3/15/2024 - PREVIOUS INSPECTION NOTES Sprinkler room walls are approved. Highlighted plans. Ceiling not yet framed.
HVAC ROUGH 04/18/2024 APPROVED CPISCITELLI
Note: 3/8/2024 - PREVIOUS INSPECTION NOTES 1. Need to support fresh air boxes, remove tape and use proper material to seal annular space around boxes 2. Condensate line for minisplit not installed 3. AHU 9 not installed 4. Seams not inspected prior to wrap need to meet on site to remove wrap for seam inspection 5. One AHU too close to electrical juction box. Box not accessible 6. Several supply plenums need to be cut back as to not touch the sprinkler pipes
ELECTRIC - EARLY POWER 04/18/2024 APPROVED - AS NOTED RMARTIN
Note: WILL NEED TO KEEP MAINS AND BREAKERS LOCKED OUT UNTIL CIRCUITS ARE READY TO BE ENERGIZED
FIREWALL NAILING 03/15/2024 PARTIALLY APPROVED JWALKER
Note: Sprinkler room walls are approved. Highlighted plans. Ceiling not yet framed.
FIREWALL NAILING 03/13/2024 APPROVED FWILLIS
FIREWALL NAILING 03/12/2024 APPROVED FWILLIS
HVAC ROUGH 03/08/2024 Disapproved - NO FEE CPISCITELLI
Note: 1. Need to support fresh air boxes, remove tape and use proper material to seal annular space around boxes 2. Condensate line for minisplit not installed 3. AHU 9 not installed 4. Seams not inspected prior to wrap need to meet on site to remove wrap for seam inspection 5. One AHU too close to electrical juction box. Box not accessible 6. Several supply plenums need to be cut back as to not touch the sprinkler pipes
PLUMBING 2ND ROUGH 03/08/2024 APPROVED MGIBSON
Note: 3/7/2024 - PREVIOUS INSPECTION NOTES 2/23/2024 - PREVIOUS INSPECTION NOTES NEED TO INSTALL 2 ICEMACKER BOXES WITH SHOCK ARRESSTORS AT BOTH FRIDGE AREAS AND MID STORY STRAPS AT 3'' AND 2'' VENTS IN BATHROOM STILL NO NAIL PLATES, AND WRONG ICE-MAKER BOXES PLUMBERS HAVE A FIX FOR ICEMAKER BOXES AND NAIL PLATES ARE IN PLACE
BLD - SEWER TIE IN 03/08/2024 CANCELLED BY APPLICANT MRAMOS
PLUMBING 2ND ROUGH 03/07/2024 Disapproved -FEE REQUIRED MGIBSON
Note: 2/23/2024 - PREVIOUS INSPECTION NOTES NEED TO INSTALL 2 ICEMACKER BOXES WITH SHOCK ARRESSTORS AT BOTH FRIDGE AREAS AND MID STORY STRAPS AT 3'' AND 2'' VENTS IN BATHROOM STILL NO NAIL PLATES, AND WRONG ICE-MAKER BOXES
FIREWALL NAILING 02/28/2024 APPROVED FWILLIS
Note: 2/5/2024 - PREVIOUS INSPECTION NOTES 2/5/24 Please have the approved plans onsite for all inspections.
PLUMBING 2ND ROUGH 02/23/2024 PARTIALLY APPROVED MGIBSON
Note: NEED TO INSTALL 2 ICEMACKER BOXES WITH SHOCK ARRESSTORS AT BOTH FRIDGE AREAS AND MID STORY STRAPS AT 3'' AND 2'' VENTS IN BATHROOM
FRAMING 02/22/2024 APPROVED FWILLIS
Note: 2/5/2024 - PREVIOUS INSPECTION NOTES 2/5/24 Please have the approved set of plans onsite for all inspections. 11/15/2023 - PREVIOUS INSPECTION NOTES 11/15/23 - PARTIAL. NOT THE OFFICE. 6/14/2023 - PREVIOUS INSPECTION NOTES BUILDING "A" NOT INCLUDING THE OFFICE. ALSO DOORS ON UNITS WILL BE INSTALLED AT A FUTURE DATE. APPROVED PLANS PAGES S200 AND S201.
FRAMING 02/08/2024 CANCELLED BY APPLICANT FWILLIS
STOREFRONT 02/08/2024 APPROVED FWILLIS
FIREWALL NAILING 02/05/2024 Disapproved - NO FEE JWALKER
Note: 2/5/24 Please have the approved plans onsite for all inspections.
FRAMING 02/05/2024 Disapproved - NO FEE JWALKER
Note: 2/5/24 Please have the approved set of plans onsite for all inspections. 11/15/2023 - PREVIOUS INSPECTION NOTES 11/15/23 - PARTIAL. NOT THE OFFICE. 6/14/2023 - PREVIOUS INSPECTION NOTES BUILDING "A" NOT INCLUDING THE OFFICE. ALSO DOORS ON UNITS WILL BE INSTALLED AT A FUTURE DATE. APPROVED PLANS PAGES S200 AND S201.
ELECTRIC 2ND ROUGH 11/22/2023 APPROVED RMARTIN
ROOF SHEATHING / BRACE / TIE DOWN 11/21/2023 CANCELLED BY APPLICANT FWILLIS
Note: NEED TO DISCUSS WHAT NEEDS TO BE VIEWED AND WHAT HAS BEEN VIEWED. WILL GET WITH ROBERT.
FRAMING 11/15/2023 PARTIALLY APPROVED FWILLIS
Note: 11/15/23 - PARTIAL. NOT THE OFFICE. 6/14/2023 - PREVIOUS INSPECTION NOTES BUILDING "A" NOT INCLUDING THE OFFICE. ALSO DOORS ON UNITS WILL BE INSTALLED AT A FUTURE DATE. APPROVED PLANS PAGES S200 AND S201.
STOREFRONT 11/03/2023 APPROVED FWILLIS
Note: 11/3/23 - UPPER FLOOR 11/2/2023 - PREVIOUS INSPECTION NOTES 11/2/23 Lower store front only. 10/27/2023 - PREVIOUS INSPECTION NOTES STOREFRONT SILL ONLY
STOREFRONT 11/02/2023 PARTIALLY APPROVED JWALKER
Note: 11/2/23 Lower store front only. 10/27/2023 - PREVIOUS INSPECTION NOTES STOREFRONT SILL ONLY
STOREFRONT 10/27/2023 PARTIALLY APPROVED FWILLIS
Note: STOREFRONT SILL ONLY
FRAMING 06/14/2023 PARTIALLY APPROVED FWILLIS
Note: BUILDING "A" NOT INCLUDING THE OFFICE. ALSO DOORS ON UNITS WILL BE INSTALLED AT A FUTURE DATE. APPROVED PLANS PAGES S200 AND S201.
FOUNDATION SURVEY - OFFICE USE ONLY 04/19/2023 APPROVED DLEAP
BLD - SITE STRUCTURE - TRASH DUMPSTER 02/28/2023 CANCELLED BY APPLICANT LMILLER
Note: wrong inspection tie beam needed, tie beam inspection added and resulted
TIE BEAM 02/28/2023 APPROVED LMILLER
Note: inspection for Dumpster coral only
BLD - SITE STRUCTURE - TRASH DUMPSTER 01/25/2023 APPROVED LMILLER
Note: 1/17/2023 - PREVIOUS INSPECTION NOTES Clearance on reinforcing bars per TABLE 1808.8.2 MINIMUM CONCRETE COVER not met 1-25-23 notes above resolved
BLD - SITE STRUCTURE - TRASH DUMPSTER 01/17/2023 Disapproved -FEE REQUIRED LMILLER
Note: Clearance on reinforcing bars per TABLE 1808.8.2 MINIMUM CONCRETE COVER not met
MONOLITHIC SLAB 11/08/2022 APPROVED DCUSHING
Note: 10/24/2022 - PREVIOUS INSPECTION NOTES Main section of Bldg A
ASPHALT STRIPING 11/07/2022 CANCELLED BY APPLICANT WEB
MONOLITHIC SLAB 10/24/2022 PARTIALLY APPROVED DCUSHING
Note: Main section of Bldg A
PLUMBING 1ST ROUGH 10/19/2022 APPROVED MGIBSON

Review History

Department Status Date In Date Out
BLD COMPLETE 06/20/2024 06/20/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 06/14/2024 06/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Documents rejected. Already uploaded to BDA permit and approved
FI1 COMPLETE 06/14/2024 06/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Documents rejected. Already uploaded to BDA permit and approved
FI1 COMPLETE 05/13/2024 05/28/2024
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
MECH COMPLETE 04/11/2024 04/19/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/01/2024 04/02/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 03/19/2024 04/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 03/19/2024 03/25/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide hanging detail for AHU new location
BADMIN INFORMATION 03/13/2024 03/13/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Documents/Files named incorrectly o Please rename your files in accordance with the naming convention outlined in our ‘document requirements’ located on the permit portal page http://docs.palmcoastgov.com/departments/building/online/document-requirements.pdf o It is important that all submittals follow the guidelines for efficient plan review and record retention accuracy. o You may add to your file name AFTER the above naming convention has been met. Examples Document type: Plans File name : Given sheet name A.1 / Plans Document type: Foundation Survey File name: Foundation Survey Document type: Manufactures Specifications File Name: Pool Alarm Document type: Manufactures Specifications File Name: Generator Revisions and corrections should follow the same criteria and should use the same name as the original originally identified. (no – new, revised, second submittal, updated)
ELEC COMPLETE 01/12/2024 01/19/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 05/25/2023 06/08/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 05/24/2023 05/24/2023
Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM Plans missing digital signature.
BLD HOLD 05/24/2023 05/24/2023
Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM SIGNATURE NOT VERIFIED
BADMIN INFORMATION 05/17/2023 05/17/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Documents uploaded are to be uploaded as separate pages and the files named in accordance with the file naming convention located on the 'document submittal requirements' located on the permitting portal. The file names should be consistent with the original file names.
PLENG COMPLETE 04/18/2023 04/18/2023
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
BADMIN INFORMATION 03/31/2023 03/31/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM You uploaded under elevation certificate a document named foundation survey. Those are two different review departments. Please correct/clarify the correct submittal. (change file name or change document type)
PLENG HOLD 03/31/2023 04/03/2023
Note: Held By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM Label plan as "Foundation Survey". The plan is currently labelled as a Topographic Survey.
DSD COMPLETE 03/31/2023 03/31/2023
Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM
BADMIN INFORMATION 07/11/2022 07/11/2022
Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM We received check 001023 in the amount $188.269.15. However the amount due $188.269.16. We are unable to process this payment.
FI1 COMPLETE 05/18/2022 05/20/2022
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
BLD COMPLETE 05/18/2022 05/25/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
MECH COMPLETE 05/06/2022 05/06/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
FI1 HOLD 05/06/2022 05/13/2022
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please show location of responses in a response letter and provide clouded response changes The following is still needed. (the areas accessed by the exterior only will need to have coverage met with extinguisher within site, extinguishers inside will not meet the requirement) 1. per NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. The maximum travel distance must be calculated per FFPC 1, chapter 6 tables 6.2.1.1 and 6.3.1.1 Please show the Extinguisher size used for calculating travel distance (provide sheet number) and show the calculations. (several areas of coverage are still needed)
BLD COMPLETE 03/29/2022 04/05/2022
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
FI1 HOLD 03/29/2022 04/11/2022
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please show location of responses in a response letter and provide clouded response changes The following is still needed.... 1. The following is still needed. per NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. The maximum travel distance must be calculated per FFPC 1, chapter 6 tables 6.2.1.1 and 6.3.1.1 Please show the Extinguisher size used for calculating travel distance (provide sheet number) and show the calculations. (several areas of coverage are still needed)
MECH HOLD 03/29/2022 03/30/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Revise equipment schedule to correspond with heatload calculation. Tonnages are not correlating. (Spoke to architect)
MECH HOLD 01/19/2022 01/20/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Revise equipment schedule to correspond with heatload calculation. Tonnages are not correlating. 2. Provide heatload on seperate letter or plans. Not on response letter. (Second Request)
PLUM COMPLETE 01/19/2022 01/20/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD HOLD 01/19/2022 01/20/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Repeat comment item 4 from previous hold comments: 4. Various Product Approvals submitted are either outdated or incorrect. A revision to the Product Approvals is required. Per F.S. 471.025 and F.A.C. 61 G15-23.005. a. 15-0127.05 is outdated. b. Metal Wall Panels Product Approval does not match the Product Approval Sheet. c. Glass sliding doors Product Approval does not match the Product Approval Sheet. d. Egress doors Product Approval does not match the Product Approval Sheet. Note: Submitted correction for the above item still unclear. Some FL Numbers on Product Approval Specification Sheet does not match with those FL Numbers shown on Drawing Sheet T- 001.00. Please coordinate for clarity. Cut sheets are not a substitute to the product approval numbers.
FI1 HOLD 01/19/2022 01/25/2022
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please show location of responses in a response letter and provide clouded response changes The following is still needed... 1. Digital seals need to be live on all documents 2. The following is still needed. per NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. The maximum travel distance must be calculated per FFPC 1, chapter 6 tables 6.2.1.1 and 6.3.1.1 Please show the Extinguisher size used for calculating travel distance (provide sheet number) and show the calculations.
MECH HOLD 12/10/2021 12/14/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Revise equipment schedule to correspond with heatload calculation. Tonnages are not correlating. 2. Provide heatload on seperate letter or plans. Not on response letter.
PLUM HOLD 12/10/2021 12/17/2021
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Comments from previous hold: 1. OK.. 2. Keyed Notes on Sheet P-101.01, Enlarged Pressure Plan. One note is shown with an X. A revision to the Notes to provide what is called-out with the X.
BLD HOLD 12/10/2021 12/17/2021
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comment item 4 from previous hold comments: . 4. Various Product Approvals submitted are either outdated or incorrect. A revision to the Product Approvals is required. Per F.S. 471.025 and F.A.C. 61 G15-23.005. Note : Submitted correction for the above item still unclear. Some FL Numbers on Product Approval Specification Sheet does not match with those FL Numbers shown on Drawing Sheet T- 001.00. Please coordinate for clarity.
FI1 HOLD 12/10/2021 12/27/2021
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM 1. Digital seals need to be live on all documents 2. The following is still needed. per NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. The maximum travel distance must be calculated per FFPC 1, chapter 6 tables 6.2.1.1 and 6.3.1.1 Please show the Extinguisher size used for calculating travel distance (provide sheet number) and show the calculations.
ARCHR COMPLETE 09/27/2021 10/08/2021
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
BLD HOLD 09/27/2021 10/06/2021
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building PLAN REVIEW COMMENTS: 1. Provide complete copy of Geotechnical Investigation Report signed and sealed by a Florida licensed professional engineer. It appears a geotechnical investigation report was not included with the civil plans under the Commercial Site Development Permit. 2. Applicable Building Codes referenced on sheet T-001.00 are not the current Code referenced. As of January 1, 2021, Florida State adopted the 2020 Florida Building Code 7th Edition. 3. Following Comments are from sheet A-010.00; a) As mentioned above, the Code reference is incorrect. b) Florida State does not have State Supplement c) Interior Environment and Chapter 15 reference the 2014 FBC. d) The Florida Building Code and the NFPA Standard was used for the Code Analysis of the proposed building. Per Section 102.4, 2020 Florida Building Code. The most restrictive is to be used. The Building Code is more restrictive and shall be used for the Code Analysis. 4. Various Product Approvals submitted are either outdated or incorrect. A revision to the Product Approvals is required. Per F.S. 471.025 and F.A.C. 61 G15-23.005.
DSD COMPLETE 09/27/2021 10/08/2021
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
ELEC COMPLETE 09/27/2021 10/04/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
FI1 HOLD 09/27/2021 10/11/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Please show location of responses in a response letter and provide clouded response changes Need separate permits for Fire Underground per FFPC, NFPA 1, Fire Code section 1.12.8 Need separate permits for Fire alarms and detection systems and related equipment per FFPC, NFPA 1, Fire Code section 1.12.8 1. Please place the following notes on the Title Page T-001.00 2. Need separate permits for Automatic fire sprinkler systems per FFPC, NFPA 1, Fire Code section 1.12.8 3. Applicable Fire Codes referenced on sheet T-001.00 and A-010.00 are not the current Code referenced. Please list FFPC 2020 7th Edition for review. 4. FP-100.00 is listed on the Title page as the Fire protection site plan and is not provided. 5. Please rename Egress plan to Life safety Plan and show on cover sheet. 6. Please provide information on the knox box for rapid entry access of fire department per NFPA 1, 18.2.2.2, FFPC 1 - 18.2.3.4.1.2 and AHJ. And place the following on the cover sheet: Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes 7. Please note, storz/locking caps (not allowed per ahj). Please provide notes for standard fire department threads on fdc per ahj 8. Please revise FDC detail to reflect the changes on sheet FP-201.00 9. Please identify Class of Hazard per FBC 2020 7th edition Chapter 9, 906.3, 906.3.1, 906.3.2, 906,3.3, 906.3.4 10. Please see NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the number of and maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. 11. Please show location of required extinguishers on Life Safety Plan and place per FBC 2020 7th edition chapter 9, 906.5 and 906.6 including areas accessed only from the exterior. 12. Need to know the height of the covered loading area (define minimum clearance height)
PLUM HOLD 09/27/2021 10/06/2021
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Plumbing PLAN REVIEW COMMENTS: 1. Provide complete copy of Geotechnical Investigation Report signed and sealed by a Florida licensed professional engineer. It appears a geotechnical investigation report was not included with the civil plans under the Commercial Site Development Permit. 2. Keyed Notes on Sheet P-101.01, Enlarged Pressure Plan. One note is shown with an X. A revision to the Notes to provide what is called-out with the X.
UD1 COMPLETE 09/27/2021 09/28/2021
Note: Released By: CHRIS JOHNSON - - CJOHNSON@PALMCOASTGOV.COM
MECH HOLD 09/27/2021 10/04/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM This is correct review. It was completed by mistake. 1. Need to reference 7Th edition for all Building codes 2. Provide heatload calculation per C403.2.1 FBC Energy Conservation 2020 7Th edition

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 06/17/2024
PLAN REVIEW - REVISION ¤32.50 06/17/2024
REINSPECTION - COMMERCIAL ¤60.00 06/17/2024
REINSPECTION - COMMERCIAL ¤60.00 06/17/2024
CONTRACTOR CHANGE ¤20.00 06/17/2024
CONTRACTOR CHANGE ¤20.00 06/17/2024
CONTRACTOR CHANGE ¤20.00 06/17/2024
CONTRACTOR CHANGE ¤20.00 06/17/2024
3% FIRE IMPACT FEE CREDIT (¤2,931.40) 07/25/2022
IMPACT FEE FIRE ¤97,713.44 07/25/2022
IMPACT FEE TRANSPORTATION ¤74,692.82 07/25/2022
SURCHARGE FS 533.721 ¤204.80 07/25/2022
SURCHARGE - FS 468.631 ¤310.27 07/25/2022
3% TRANS IMPACT FEE CREDIT (¤2,240.78) 07/25/2022
SITE PLAN 30 ¤30.00 07/25/2022
CONTRACTOR CHANGE ¤40.00 07/25/2022
ADMINISTRATIVE - COMMERCIAL ¤75.00 07/25/2022
INSPECTION COMMERCIAL ¤17,500.00 07/25/2022
PLAN REVIEW - COMMERCIAL ¤2,875.00 07/25/2022
Fees Total Due: ¤0.00 Total Paid: ¤188,534.15