I want to search for...
Permit #2021091193
Permit Details
Status: COED
| Total Square Footage: 55071 sqft |
| Block: 00000 |
| Subdivision: - |
| Job Phone: 321-723-5661 |
| Location Address: 5622 STATE HWY 100 E |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 07/11/2022 |
| NOC: RECORDED |
| Applicant name: GARY HOWELL II NEAL |
| Owner: SKUSA PALM COAST LLC |
|
Address C/O ANDOVER PROPERTIES LLC NEW YORK, NY 10022 |
|
Address 32nd FLOOR NEW YORK, NY 10022 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤2,500,000.00 |
| Job Description: BUILDING B - SELF STORAGE 50,000 SQ FT. |
| Type: CN |
Contractor
M E CONSTRUCTION INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
445 PINEDA CT MELBOURNE, FL 32940 |
CGC1525425 (Exp: 08/31/2026) | 321-723-5661 |
Sub Contractors
FERNANDO DE ARMAS
| Status | Location Address | State License Number | Phone |
| INACTIVE |
6163 47TH STREET E , 0 |
CAC1817280 (Exp: 08/31/2024) | 941-241-6689 |
MICHAEL KELLEY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
5037 CRILL AVE PALATKA, FL 32177 |
EC13012806 (Exp: 08/31/2026) | 904-808-3192 |
ORLANDO GONZALEZ
| Status | Location Address | State License Number |
| INACTIVE |
17501 NW 47TH CT MIAMI GARDENS, FL 33055 |
CFC1432809 (Exp: 08/31/2026) |
Inspection History
| Type | Request Date | Result | Inspector |
| BUILDING FINAL | 06/20/2024 | FINAL APPROVED | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 6/20/2024 4:43:11 PM *** pending trade finals *** NOTES ADDED BY LMILLER 6/20/2024 4:42:54 PM *** prior notes were not resolved 6/18/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 6/18/2024 3:16:33 PM *** prior notes were not resolved 6/14/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 6/14/2024 2:57:02 PM *** ADDRESS IDENTIFICATION FFPC 8TH EDITION 10.12.1.5 MINUMUM 6inches IN HEIGHT (OTHER THAN RESIDENTIAL) egress door at back end of building needs to be operable (will not open for egress) | |||
| FIRE FINAL | 06/20/2024 | APPROVED | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 6/20/2024 4:42:37 PM *** prior notes were not resolved 6/18/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 6/18/2024 3:16:00 PM *** The letter from the alarm company must be uploaded and approved prior to re-calling the fire final *** NOTES ADDED BY LMILLER 6/18/2024 3:14:54 PM *** TRrhere was an agreement made between Fire Marshal Randy Holmes and the contractor that the entry gate will be locked in the up and open position until such time as the gate knox switch is operable and the Fire Marshal Randy Holmes has verfied the gate knoxswitch is working | |||
| FIRE FINAL | 06/18/2024 | Disapproved - NO FEE | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 6/18/2024 3:16:00 PM *** The letter from the alarm company must be uploaded and approved prior to re-calling the fire final *** NOTES ADDED BY LMILLER 6/18/2024 3:14:54 PM *** TRrhere was an agreement made between Fire Marshal Randy Holmes and the contractor that the entry gate will be locked in the up and open position until such time as the gate knox switch is operable and the Fire Marshal Randy Holmes has verfied the gate knoxswitch is working | |||
| BUILDING FINAL | 06/18/2024 | Disapproved -FEE REQUIRED | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 6/18/2024 3:16:33 PM *** prior notes were not resolved 6/14/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 6/14/2024 2:57:02 PM *** ADDRESS IDENTIFICATION FFPC 8TH EDITION 10.12.1.5 MINUMUM 6inches IN HEIGHT (OTHER THAN RESIDENTIAL) egress door at back end of building needs to be operable (will not open for egress) | |||
| PLUMBING FINAL | 06/18/2024 | CANCELLED BY APPLICANT | JWALKER |
| Note: Inspector Notes from Inspection 3080 3/7/2024 - PREVIOUS INSPECTION NOTES NEED TO SECURE WATER LINES OVER HEAD EVERY 3' ALSO NEED TO REPLACE PRESSURE TEE TO ''DWV'' TWIN ELL NEED TO SECURE WATER LINE RAN WITH CORRECT HOLD RIGHTS OR SECURE WITH ANOTHER METHOD | |||
| PLUMBING FINAL | 06/18/2024 | FINAL APPROVED | JWALKER |
| Note: 6/18/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 3080 3/7/2024 - PREVIOUS INSPECTION NOTES NEED TO SECURE WATER LINES OVER HEAD EVERY 3' ALSO NEED TO REPLACE PRESSURE TEE TO ''DWV'' TWIN ELL NEED TO SECURE WATER LINE RAN WITH CORRECT HOLD RIGHTS OR SECURE WITH ANOTHER METHOD | |||
| BUILDING FINAL | 06/14/2024 | PARTIALLY APPROVED | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 6/14/2024 2:57:02 PM *** ADDRESS IDENTIFICATION FFPC 8TH EDITION 10.12.1.5 MINUMUM 6inches IN HEIGHT (OTHER THAN RESIDENTIAL) egress door at back end of building needs to be operable (will not open for egress) | |||
| U - UTILITY COMMERCIAL FINAL | 06/14/2024 | FINAL APPROVED | LFITZGERALD |
| EXTERIOR ARCHITECTURAL FEATURES | 06/12/2024 | APPROVED | RPICATAGI |
| ELECTRIC FINAL | 06/10/2024 | APPROVED | RMARTIN |
| Note: 6/6/2024 - PREVIOUS INSPECTION NOTES | |||
| FOOTER | 06/07/2024 | CANCELLED BY INSPECTOR | FWILLIS |
| INSULATION | 06/07/2024 | CANCELLED BY INSPECTOR | FWILLIS |
| STOREFRONT | 06/07/2024 | CANCELLED BY INSPECTOR | FWILLIS |
| ROOF SHEATHING / BRACE / TIE DOWN | 06/07/2024 | CANCELLED BY INSPECTOR | FWILLIS |
| ASPHALT STRIPING | 06/07/2024 | CANCELLED BY INSPECTOR | FWILLIS |
| HVAC FINAL | 06/07/2024 | FINAL APPROVED | CPISCITELLI |
| Note: | |||
| HVAC FINAL | 06/06/2024 | Disapproved - NO FEE | CPISCITELLI |
| Note: Need to have heater stickers on AHUs. Could not verify breakers | |||
| ELECTRIC FINAL | 06/06/2024 | CANCELLED BY APPLICANT | RMARTIN |
| ABOVE CEILING | 05/30/2024 | APPROVED | CPISCITELLI |
| Note: 5/23/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY CPISCITELLI 5/23/2024 3:40:38 PM *** 1. Need to put hose clamp on barb fitting for minisplit condensate 2. Minisplit condensate needs to be trapped or check valve before pump 3. Need to support exhaust duct in bathrooms and janitor closet and fasten duct to fans with screws 4. Missing balancing dampers | |||
| ABOVE CEILING | 05/23/2024 | Disapproved -FEE REQUIRED | CPISCITELLI |
| Note: *** NOTES ADDED BY CPISCITELLI 5/23/2024 3:40:38 PM *** 1. Need to put hose clamp on barb fitting for minisplit condensate 2. Minisplit condensate needs to be trapped or check valve before pump 3. Need to support exhaust duct in bathrooms and janitor closet and fasten duct to fans with screws 4. Missing balancing dampers | |||
| PLUMBING 2ND ROUGH | 03/11/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: 3/7/2024 - PREVIOUS INSPECTION NOTES NEED TO SECURE WATER LINES OVER HEAD EVERY 3' ALSO NEED TO REPLACE PRESSURE TEE TO ''DWV'' TWIN ELL NEED TO SECURE WATER LINE RAN WITH CORRECT HOLD RIGHTS OR SECURE WITH ANOTHER METHOD | |||
| HVAC ROUGH | 03/08/2024 | APPROVED - AS NOTED | CPISCITELLI |
| Note: 1. Need to support fresh air boxes, remove tape and use proper material to seal annular space around boxes 2. Metal strap hitting sprinkler pipe | |||
| ALL ROUGH | 03/08/2024 | CANCELLED BY INSPECTOR | RMARTIN |
| Note: NEED TO CALL IN YOUR M.E.P INSPECTIONS, WE DO NOT DO ALL ROUGH ON COMMERCIAL | |||
| PLUMBING 2ND ROUGH | 03/07/2024 | Disapproved - NO FEE | MGIBSON |
| Note: NEED TO SECURE WATER LINES OVER HEAD EVERY 3' ALSO NEED TO REPLACE PRESSURE TEE TO ''DWV'' TWIN ELL | |||
| FRAMING | 02/22/2024 | APPROVED | FWILLIS |
| ELECTRIC 2ND ROUGH | 11/22/2023 | APPROVED | RMARTIN |
| Note: Inspector Notes from Inspection 3180 2/14/23 this was approved on the electric underground 9/22/2022 - PREVIOUS INSPECTION NOTES ufer ground building b | |||
| FRAMING | 11/15/2023 | APPROVED | FWILLIS |
| Note: 11/15/23 - FRAMING APPROVED EXCEPT ELECTRICAL ROOM FIREWALLS. 6/21/2023 - PREVIOUS INSPECTION NOTES 4/20/2023 - PREVIOUS INSPECTION NOTES COURTESY INSPECTIONS. PROJECT SUPER: JIM GREENE 508-989-1465 6/21/23 - "B" BUILDING ONLY. BATHROOM PANELS AND DOORS WILL BE INSTALLED AT A LATER DATE | |||
| FRAMING | 06/21/2023 | PARTIALLY APPROVED | FWILLIS |
| Note: 4/20/2023 - PREVIOUS INSPECTION NOTES COURTESY INSPECTIONS. PROJECT SUPER: JIM GREENE 508-989-1465 6/21/23 - "B" BUILDING ONLY. BATHROOM PANELS AND DOORS WILL BE INSTALLED AT A LATER DATE | |||
| HVAC ROUGH | 04/24/2023 | APPROVED | CPISCITELLI |
| Note: will look at wrap on final inspection Google duo with jim walker 4/20/2023 - PREVIOUS INSPECTION NOTES Inspected straight seams and fresh air. Need to check elbows, tees and connection to unit | |||
| HVAC ROUGH | 04/20/2023 | PARTIALLY APPROVED | CPISCITELLI |
| Note: Inspected straight seams and fresh air. Need to check elbows, tees and connection to unit | |||
| FRAMING | 04/20/2023 | CANCELLED BY APPLICANT | FWILLIS |
| Note: COURTESY INSPECTIONS. PROJECT SUPER: JIM GREENE 508-989-1465 | |||
| FOUNDATION SURVEY - OFFICE USE ONLY | 04/19/2023 | APPROVED | DLEAP |
| PLUMBING 1ST ROUGH | 02/15/2023 | APPROVED | MGIBSON |
| Note: 9/22/2022 - PREVIOUS INSPECTION NOTES THIS WAS THE FIRST PARTIAL INSPECTION | |||
| ASPHALT STRIPING | 02/14/2023 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC 1ST ROUGH | 02/14/2023 | APPROVED - AS NOTED | RMARTIN |
| Note: 2/14/23 this was approved on the electric underground 9/22/2022 - PREVIOUS INSPECTION NOTES ufer ground building b | |||
| ELECTRIC UNDERGROUND | 01/20/2023 | APPROVED | RMARTIN |
| MONOLITHIC SLAB | 11/08/2022 | APPROVED | DCUSHING |
| Note: 9/26/2022 - PREVIOUS INSPECTION NOTES 9/23/2022 - PREVIOUS INSPECTION NOTES 1st pour, marked on plans in trailer 9/26/22 - added section for first pour, marked on plans in trailer | |||
| MONOLITHIC SLAB | 09/26/2022 | PARTIALLY APPROVED | DCUSHING |
| Note: 9/23/2022 - PREVIOUS INSPECTION NOTES 1st pour, marked on plans in trailer 9/26/22 - added section for first pour, marked on plans in trailer | |||
| MONOLITHIC SLAB | 09/23/2022 | PARTIALLY APPROVED | DCUSHING |
| Note: 1st pour, marked on plans in trailer | |||
| ELECTRIC 1ST ROUGH | 09/22/2022 | PARTIALLY APPROVED | RMARTIN |
| Note: ufer ground building b | |||
| PLUMBING 1ST ROUGH | 09/22/2022 | PARTIALLY APPROVED | MGIBSON |
| Note: THIS WAS THE FIRST PARTIAL INSPECTION |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 06/20/2024 | 06/20/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/14/2024 | 06/17/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Documents not needed on this permit because they were uploaded to the BDA permit already and approved. | |||
| FI1 | COMPLETE | 06/14/2024 | 06/17/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Documents not needed on this permit because they were uploaded to the BDA permit already and approved. | |||
| DSD | COMPLETE | 06/12/2024 | 06/12/2024 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM | |||
| FI1 | COMPLETE | 05/13/2024 | 05/28/2024 |
| Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/09/2023 | 10/17/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/25/2023 | 06/08/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 05/17/2023 | 05/17/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Documents uploaded are to be uploaded as separate pages and the files named in accordance with the file naming convention located on the 'document submittal requirements' located on the permitting portal. The file names should be consistent with the original file names. | |||
| PLENG | COMPLETE | 04/19/2023 | 04/19/2023 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/18/2022 | 05/25/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| FI1 | COMPLETE | 05/18/2022 | 05/20/2022 |
| Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/06/2022 | 05/06/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| FI1 | HOLD | 05/06/2022 | 05/13/2022 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please show location of responses in a response letter and provide clouded response changes The following is still needed. (the areas accessed by the exterior only will need to have coverage met with extinguisher within site, extinguishers inside will not meet the requirement) 1. per NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. The maximum travel distance must be calculated per FFPC 1, chapter 6 tables 6.2.1.1 and 6.3.1.1 Please show the Extinguisher size used for calculating travel distance (provide sheet number) and show the calculations. (several areas of coverage are still needed) | |||
| BLD | HOLD | 05/06/2022 | 05/11/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Repeat comment item 4 from previous hold comments: 4. Various Product Approvals submitted are either outdated or incorrect. A revision to the Product Approvals is required. Per F.S. 471.025 and F.A.C. 61 G15-23.005. a. 20-1106.05 & 18-0123.13 both are expired. | |||
| BADMIN | INFORMATION | 05/06/2022 | 05/06/2022 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM For future submittals, files ulpoaded should follow the same requriements as the original uploads - naming convention and document type. Calculations should not be ulpoaded under 'plans'. Supporting documents should not be uploaded under 'plans'. plans sheets should be the sheet name - file names should always start with that. (or the description of the sheet) Updates were made to your submittals and can be viewed online. | |||
| BLD | HOLD | 03/29/2022 | 04/12/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Repeat comment item 4 from previous hold comments: 4. Various Product Approvals submitted are either outdated or incorrect. A revision to the Product Approvals is required. Per F.S. 471.025 and F.A.C. 61 G15-23.005. a. 15-0127.05 is outdated. b. Metal Wall Panels Product Approval does not match the Product Approval Sheet. c. Glass sliding doors Product Approval does not match the Product Approval Sheet. d. Egress doors Product Approval does not match the Product Approval Sheet. Note: Submitted correction for the above item still unclear. Some FL Numbers on Product Approval Specification Sheet does not match with those FL Numbers shown on Drawing Sheet T- 001.00. Please coordinate for clarity. Cut sheets are not a substitute to the product approval numbers. | |||
| FI1 | HOLD | 03/29/2022 | 04/11/2022 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please show location of responses in a response letter and provide clouded response changes The following is still needed.... 1. The following is still needed. per NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. The maximum travel distance must be calculated per FFPC 1, chapter 6 tables 6.2.1.1 and 6.3.1.1 Please show the Extinguisher size used for calculating travel distance (provide sheet number) and show the calculations. (several areas of coverage are still needed) | |||
| MECH | HOLD | 03/29/2022 | 03/30/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Revise equipment schedule to correspond with heatload calculation. Tonnages are not correlating. (Spoke to architect) | |||
| MECH | HOLD | 01/19/2022 | 01/20/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Revise equipment schedule to correspond with heatload calculation. Tonnages are not correlating. 2. Provide heatload on seperate letter or plans. Not on response letter. (Second Request) | |||
| BLD | HOLD | 01/19/2022 | 01/20/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Repeat comment item 4 from previous hold comments: 4. Various Product Approvals submitted are either outdated or incorrect. A revision to the Product Approvals is required. Per F.S. 471.025 and F.A.C. 61 G15-23.005. a. 15-0127.05 is outdated. b. Metal Wall Panels Product Approval does not match the Product Approval Sheet. c. Glass sliding doors Product Approval does not match the Product Approval Sheet. d. Egress doors Product Approval does not match the Product Approval Sheet. Note: Submitted correction for the above item still unclear. Some FL Numbers on Product Approval Specification Sheet does not match with those FL Numbers shown on Drawing Sheet T- 001.00. Please coordinate for clarity. Cut sheets are not a substitute to the product approval numbers. | |||
| PLUM | COMPLETE | 01/19/2022 | 01/20/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| FI1 | HOLD | 01/19/2022 | 01/25/2022 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please show location of responses in a response letter and provide clouded response changes The following is still needed.... 1. Digital seals need to be live on all documents 2. The following is still needed. per NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. The maximum travel distance must be calculated per FFPC 1, chapter 6 tables 6.2.1.1 and 6.3.1.1 Please show the Extinguisher size used for calculating travel distance (provide sheet number) and show the calculations. | |||
| MECH | HOLD | 12/10/2021 | 12/14/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Revise equipment schedule to correspond with heatload calculation. Tonnages are not correlating. 2. Provide heatload on seperate letter or plans. Not on response letter. | |||
| BLD | HOLD | 12/10/2021 | 12/20/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Various Product Approvals submitted are either outdated or incorrect. A revision to the Product Approvals is required. Per F.S. 471.025 and F.A.C. 61 G15-23.005. A reivison to the product approval sheet is required. | |||
| PLUM | HOLD | 12/10/2021 | 12/20/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Plumbing PLAN REVIEW COMMENTS: 1. OK 2. Keyed Notes on Sheet P-101.01, Enlarged Pressure Plan. One note is shown with an X. A revision to the Notes to provide what is called-out with the X. | |||
| FI1 | HOLD | 12/10/2021 | 12/27/2021 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM 1. Digital seals need to be live on all documents 2. The following is still needed. per NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. The maximum travel distance must be calculated per FFPC 1, chapter 6 tables 6.2.1.1 and 6.3.1.1 Please show the Extinguisher size used for calculating travel distance (provide sheet number) and show the calculations. | |||
| ARCHR | COMPLETE | 09/27/2021 | 10/08/2021 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/27/2021 | 10/06/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building PLAN REVIEW COMMENTS: 1. Provide complete copy of Geotechnical Investigation Report signed and sealed by a Florida licensed professional engineer. It appears a geotechnical investigation report was not included with the civil plans under the Commercial Site Development Permit. 2. Applicable Building Codes referenced on sheet T-001.00 are not the current Code referenced. As of January 1, 2021, Florida State adopted the 2020 Florida Building Code 7th Edition. 3. Following Comments are from sheet A-010.00; a) As mentioned above, the Code reference is incorrect. b) Florida State does not have State Supplement c) Interior Environment and Chapter 15 reference the 2014 FBC. d) The Florida Building Code and the NFPA Standard was used for the Code Analysis of the proposed building. Per Section 102.4, 2020 Florida Building Code. The most restrictive is to be used. The Building Code is more restrictive and shall be used for the Code Analysis. 4. Various Product Approvals submitted are either outdated or incorrect. A revision to the Product Approvals is required. Per F.S. 471.025 and F.A.C. 61 G15-23.005. | |||
| DSD | COMPLETE | 09/27/2021 | 10/08/2021 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 09/27/2021 | 10/04/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| FI1 | HOLD | 09/27/2021 | 10/11/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Please show location of responses in a response letter and provide clouded response changes Need separate permits for Fire Underground per FFPC, NFPA 1, Fire Code section 1.12.8 Need separate permits for Fire alarms and detection systems and related equipment per FFPC, NFPA 1, Fire Code section 1.12.8 1. Please place the following notes on the Title Page T-001.00 2. Need separate permits for Automatic fire sprinkler systems per FFPC, NFPA 1, Fire Code section 1.12.8 3. Applicable Fire Codes referenced on sheet T-001.00 and A-010.00 are not the current Code referenced. Please list FFPC 2020 7th Edition for review. 4. FP-100.00 is listed on the Title page as the Fire protection site plan and is not provided. 5. Please rername Egress plan to Life safety Plan and show on cover sheet. 6. Please provide information on the knox box for rapid entry access of fire department per NFPA 1, 18.2.2.2, FFPC 1 - 18.2.3.4.1.2 and AHJ. And place the following on the cover sheet: Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes 7. Please note, storz/locking caps (not allowed per ahj). Please provide notes for standard fire department threads on fdc per ahj 8. Please revise FDC detail to reflect the changes on sheet FP-201.00 9. Please identify Class of Hazard per FBC 2020 7th edition Chapter 9, 906.3, 906.3.1, 906.3.2, 906,3.3, 906.3.4 10. Please see NFPA 10 (2018) Chapter 5 Section 5.4 Chapter 6 Sections 6.1, 6.2, and 6.3 and make the appropriate change to the number of and maximum travel distance for Fire extinguishers based on a classification of Ordinary (Moderate) Hazard Occupancy. 11. Please show location of required extinguishers on Life Safety Plan and place per FBC 2020 7th edition chapter 9, 906.5 and 906.6 including areas accessed only from the exterior. | |||
| MECH | HOLD | 09/27/2021 | 10/04/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Need to reference 7Th edition for all Building codes 2. Provide heatload calculation per FBC Energy Conservation 2020 7Th edition | |||
| PLUM | HOLD | 09/27/2021 | 10/06/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Plumbing PLAN REVIEW COMMENTS: 1. Provide complete copy of Geotechnical Investigation Report signed and sealed by a Florida licensed professional engineer. It appears a geotechnical investigation report was not included with the civil plans under the Commercial Site Development Permit. 2. Keyed Notes on Sheet P-101.01, Enlarged Pressure Plan. One note is shown with an X. A revision to the Notes to provide what is called-out with the X. | |||
| UD1 | COMPLETE | 09/27/2021 | 09/28/2021 |
| Note: Released By: CHRIS JOHNSON - - CJOHNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION - COMMERCIAL | ¤60.00 | 06/18/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 06/17/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 06/17/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 06/17/2024 |
| REINSPECTION - COMMERCIAL | ¤60.00 | 06/17/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 06/17/2024 |
| 3% FIRE IMPACT FEE CREDIT | (¤892.35) | 07/11/2022 |
| IMPACT FEE FIRE | ¤29,744.85 | 07/11/2022 |
| IMPACT FEE TRANSPORTATION | ¤22,737.17 | 07/11/2022 |
| SURCHARGE FS 533.721 | ¤204.80 | 07/11/2022 |
| SURCHARGE - FS 468.631 | ¤310.27 | 07/11/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤682.12) | 07/11/2022 |
| SITE PLAN 30 | ¤30.00 | 07/11/2022 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 07/11/2022 |
| INSPECTION COMMERCIAL | ¤17,500.00 | 07/11/2022 |
| PLAN REVIEW - COMMERCIAL | ¤2,875.00 | 07/11/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 07/11/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 07/11/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤72,195.12 |