I want to search for...
Permit #2021100365
Permit Details
Status: COED
| Parcel Id: 42-10-30-3210-00000-0120 |
| CONDITIONED SPACE: 2901 sqft |
| GARAGE: 599 sqft |
| OPENED PORCH (WITH ROOF) : 749 sqft |
| OPENED PORCH (WITH ROOF) : 62 sqft |
| Total Square Footage: 4311 sqft |
| Block: 00000 |
| Subdivision: 2094 - CONSERVATORY AT HAMMOCK BEACH |
| Job Phone: 386-447-4400 |
| Location Address: 809 LOBLOLLY CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/08/2021 |
| NOC: RECORDED |
| Applicant name: DAVID PAUL CROCKETT |
| Owner: BLAKE JOHN F & JANET M LUISI |
|
Address 130 SUNSET HARBOR WAY, A-202 ST AUGUSTINE, FL 32080 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤543,500.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SALTWATER HOMES INC
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| DECEASED |
138 PALM COAST PARKWAY PALM COAST, FL 32137 |
SUITE 328 PALM COAST, FL 32137 |
RG0041345 (Exp: 08/31/2025) | 386-447-4400 | 866-244-9639 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
THOMAS A REGULA
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11320 PHILLIPS PKWY DRIVE E JACKSONVILLE, FL 32256 |
CMC1250075 (Exp: 08/31/2026) | 904-278-0339 | 904-278-0366 |
DENNIS GENE GAINEY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P.O. BOX 1203 Bunnell, FL 32110 |
CFC046004 (Exp: 08/31/2026) | (386) 437-5637 | 386-437-3012 |
ERIC FRANCO
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
840 DELTONA BLVD DELTONA, FL 32725 |
STE F2 DELTONA, FL 32725 |
CCC1327280 (Exp: 08/31/2026) | 386-575-4007 |
KEN DEPRINZIO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
325 WALKER STREET HOLLY HILL, FL 32117 |
11351 (Exp: 08/31/2026) | 386-672-8494 | 386-673-7856 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/28/2023 | FINAL APPROVED | AGAETANO |
| U-CROSS CONNECTION | 07/21/2023 | APPROVED - AS NOTED | JHARDING |
| Note: No cross connections. | |||
| U -UTILITY RESIDENTIAL FINAL | 07/21/2023 | FINAL APPROVED | JHARDING |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/20/2023 | APPROVED | EMADISON |
| Note: * 7/19/2023 - PREVIOUS INSPECTION NOTES ** 07/19/23 NEED TO SUBMIT A NEW FINAL SURVEY ONE THAT IS NOT BLURRY AND OBSCURED NEED TO BE CLEAR | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/20/2023 | APPROVED | EMADISON |
| ROW - STORMWATER FINAL | 07/20/2023 | FINAL APPROVED | EMADISON |
| ROW - FINAL APRON (AFTER POUR) | 07/20/2023 | FINAL APPROVED | EMADISON |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/19/2023 | Disapproved - NO FEE | EMADISON |
| Note: ** 07/19/23 NEED TO SUBMIT A NEW FINAL SURVEY ONE THAT IS NOT BLURRY AND OBSCURED NEED TO BE CLEAR | |||
| ROW- PRE-APRON (PRE-POUR) | 06/16/2023 | APPROVED | EMADISON |
| Note: ** 06/16/23 READY TO SET PAVERS __________________________________________________________________________________________________________________________ 4/11/2023 - PREVIOUS INSPECTION NOTES ** 04/11/23 READY TO POUR APRON AND PAVER RESTRAINTS ** MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL __________________________________________________________________________________________________________________________ 4/10/2023 - PREVIOUS INSPECTION NOTES | |||
| TIE BEAM / LINTEL | 04/21/2023 | APPROVED | AGAETANO |
| Note: 04-21-2023 Garage opening raised from 7' to 8'. | |||
| ROW- PAVER RESTRAINTS | 04/11/2023 | APPROVED | EMADISON |
| Note: ** 04/11/23 READY TO POUR APRON AND PAVER RESTRAINTS ** MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| ROW- PRE-APRON (PRE-POUR) | 04/11/2023 | PARTIALLY APPROVED | EMADISON |
| Note: ** 04/11/23 READY TO POUR APRON AND PAVER RESTRAINTS ** MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL __________________________________________________________________________________________________________________________ 4/10/2023 - PREVIOUS INSPECTION NOTES | |||
| ROW- PRE-APRON (PRE-POUR) | 04/10/2023 | CANCELLED BY APPLICANT | EMADISON |
| ELECTRIC - EARLY POWER | 02/22/2023 | APPROVED | AGAETANO |
| GRAVITY SEWER TEST | 02/08/2023 | APPROVED | MGIBSON |
| U - SEWER TIE IN | 02/08/2023 | APPROVED | MGIBSON |
| LATH/BRICK/ WATER BARRIER | 12/15/2022 | APPROVED | AGAETANO |
| INSULATION | 10/19/2022 | APPROVED | AGAETANO |
| ELECTRIC-TUG | 10/14/2022 | APPROVED | AGAETANO |
| ALL ROUGH | 10/12/2022 | APPROVED | AGAETANO |
| ROOF VALLEY & METAL | 08/16/2022 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/12/2022 | APPROVED | LMILLER |
| TIE BEAM / LINTEL | 05/27/2022 | APPROVED | AGAETANO |
| FOUND SURVEY APPROVED (OFFICE) | 04/08/2022 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 03/03/2022 | APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION New inspection due to canceled inspection THIS IS A REINSPECTION Termite bond and compaction test not posted. 03-01-2022 - Drawings state 4" slab. Pulled test line and recorded 2 1/2". Dig slab out and tap to maintain 4". Superintendent on site for test line inspection. | |||
| MONOLITHIC SLAB | 03/01/2022 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: New inspection due to canceled inspection THIS IS A REINSPECTION Termite bond and compaction test not posted. 03-01-2022 - Drawings state 4" slab. Pulled test line and recorded 2 1/2". Dig slab out and tap to maintain 4". Superintendent on site for test line inspection. | |||
| MONOLITHIC SLAB | 02/24/2022 | CANCELLED BY APPLICANT | WEB |
| Note: THIS IS A REINSPECTION Termite bond and compaction test not posted. | |||
| MONOLITHIC SLAB | 02/22/2022 | Disapproved - NO FEE | AGAETANO |
| Note: Termite bond and compaction test not posted. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/16/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 01/13/2022 | APPROVED | TCHURCHILL |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 07/26/2023 | 07/27/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/19/2023 | 07/20/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/14/2023 | 03/16/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/07/2022 | 04/08/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/07/2022 | 04/07/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/15/2021 | 11/18/2021 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/15/2021 | 11/16/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/15/2021 | 11/17/2021 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/20/2021 | 10/20/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 10/20/2021 | 10/26/2021 |
| Note: Held By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM read the notes from the previous failed site plan | |||
| ENGIN1 | COMPLETE | 10/20/2021 | 10/20/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/20/2021 | 10/20/2021 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 10/11/2021 | 10/13/2021 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - | |||
| BLD | COMPLETE | 10/08/2021 | 10/11/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 10/08/2021 | 10/12/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 10/08/2021 | 10/11/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/08/2021 | 10/08/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 10/08/2021 | 10/11/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/08/2021 | 10/11/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder | |||
| SW1 | HOLD | 10/08/2021 | 10/13/2021 |
| Note: Held By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM See SW1 Checklist highlighted sentence in attachments dated 10/13/21. There is not enough slope/ fall away from the house along the left side property line. Right front corner is higher at the property line i.e. Compare 25.10 at property line to 25.00 outside building foundation sod grade. Also drainage should run down the property line when next to a vacant, not inside the property line. | |||
| ZON | COMPLETE | 10/08/2021 | 10/11/2021 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 07/31/2023 |
| CONTRACTOR CHANGE | ¤40.00 | 07/31/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 07/31/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 07/31/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/31/2023 |
| CONNECTION FEES | ¤25.00 | 12/08/2021 |
| METER - DEPOSIT | ¤60.00 | 12/08/2021 |
| WATER-METER | ¤441.07 | 12/08/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/08/2021 |
| INSPECTION - RESIDENTIAL | ¤1,496.00 | 12/08/2021 |
| PLAN REVIEW - RESIDENTIAL | ¤424.32 | 12/08/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 12/08/2021 |
| IMPACT FEE FIRE | ¤367.00 | 12/08/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 12/08/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 12/08/2021 |
| IMPACT FEE TRANSPORTATION | ¤3,139.00 | 12/08/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 12/08/2021 |
| SURCHARGE FS 533.721 | ¤20.31 | 12/08/2021 |
| SURCHARGE - FS 468.631 | ¤30.47 | 12/08/2021 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 12/08/2021 |
| SW ENG INSPECTION 80 | ¤80.00 | 12/08/2021 |
| SW ENG PRE APRON | ¤30.00 | 12/08/2021 |
| SW ENG - REVIEW 20 | ¤20.00 | 12/08/2021 |
| SW ENG RES REVIEW 200 | ¤200.00 | 12/08/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤94.17) | 12/08/2021 |
| SEWER INSPECTION | ¤25.00 | 12/08/2021 |
| SITE PLAN 30 | ¤30.00 | 12/08/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,281.14 |