Permit #2021100375

Permit Details

Status: COED

Parcel Id: 07-11-31-7027-00090-0340
CONDITIONED SPACE: 2091 sqft
GARAGE: 770 sqft
OPENED PORCH (WITH ROOF) : 371 sqft
OPENED PORCH (WITH ROOF) : 72 sqft
Total Square Footage: 3304 sqft
Block: 00090
Subdivision: 2128 - SECTION 27-WYNNFIELD
Job Phone: (386) 445-2222
Location Address: 11 WOODSTONE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/01/2021
NOC: RECORDED
Applicant name: MICHAEL STEPHAN MULLEN
Owner: MULLEN CONSTRUCTION CO, INC DBA

Address

TOWN & COUNTRY HOMES

BUNNELL, FL 32110

Address

1 ENTERPRISE DR

BUNNELL, FL 32110

Lot: 0340
Contracted Stated Job Value: ¤190,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

TOWN & COUNTRY HOMES
Status Location Address State License Number Phone
ACTIVE

1 Enterprise Drive

Bunnell, FL 32110

CGC049972 (Exp: 08/31/2026) (386) 445-2222

Sub Contractors

DANIEL DAVID RUTKOWSKI III
Status Location Address State License Number Phone Fax
ACTIVE

1687 STATE AVENUE

HOLLY HILL, FL 32117

CCC1328639 (Exp: 08/31/2026) 386-290-7490 386-256-0001
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
DENNIS GENE GAINEY
Status Location Address State License Number Phone Fax
INACTIVE

P.O. BOX 1203

Bunnell, FL 32110

CFC046004 (Exp: 08/31/2026) (386) 437-5637 386-437-3012
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 12/19/2022 APPROVED - AS NOTED LFITZGERALD
Note: has potable irrigation with PVB installed-no cross connection
ROW - STORMWATER FINAL 12/19/2022 CANCELLED BY APPLICANT WEB
Note: 10/28/2022 - PREVIOUS INSPECTION NOTES ** 10/28/22 RIGHT SIDE ALONG FENCE HOLDING WATER BACK RIGHT CORNER OF HOUSE BETWEEN HOUSE AND FENCE GROUND IS NOT SODDED HOLDING WATERLARGE TARP ON GROUND. ** LEFT REAR CORNER GROUND TORE UP FRONT LEFTT RUTS FROM MACHINE NEED TO BE REPAIRED ** CUT GRASS TO SEE THE CONTOURS OF LAND. 9/15/2022 - PREVIOUS INSPECTION NOTES ** 09/15/22 RIGHT REAR CORNER BETWEEN HOUSE AND FENCE LINE IS A LOW SPOT HAVING A PONDING OF WATER NEED TO RAISE WITH A POSITIVE FLOW TO THE FRONT TO DRAIN STORMWATER ** LEFT SIDE ALONG PROPERTY LINE OF CITY EASEMENT, NEEDS TO BE SODDED FOR EROSION CONTROL OF ALL BARE AREAS OF EARTH. ** LEFT SIDE BUILDER NEEDS TO REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM EASEMENT
ROW - STORMWATER FINAL 12/19/2022 APPROVED GBERTOLA
Note: 12/19/22=AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD 10/28/2022 - PREVIOUS INSPECTION NOTES ** 10/28/22 RIGHT SIDE ALONG FENCE HOLDING WATER BACK RIGHT CORNER OF HOUSE BETWEEN HOUSE AND FENCE GROUND IS NOT SODDED HOLDING WATERLARGE TARP ON GROUND. ** LEFT REAR CORNER GROUND TORE UP FRONT LEFTT RUTS FROM MACHINE NEED TO BE REPAIRED ** CUT GRASS TO SEE THE CONTOURS OF LAND. 9/15/2022 - PREVIOUS INSPECTION NOTES ** 09/15/22 RIGHT REAR CORNER BETWEEN HOUSE AND FENCE LINE IS A LOW SPOT HAVING A PONDING OF WATER NEED TO RAISE WITH A POSITIVE FLOW TO THE FRONT TO DRAIN STORMWATER ** LEFT SIDE ALONG PROPERTY LINE OF CITY EASEMENT, NEEDS TO BE SODDED FOR EROSION CONTROL OF ALL BARE AREAS OF EARTH. ** LEFT SIDE BUILDER NEEDS TO REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM EASEMENT
ROW - STORMWATER FINAL 10/28/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 10/28/22 RIGHT SIDE ALONG FENCE HOLDING WATER BACK RIGHT CORNER OF HOUSE BETWEEN HOUSE AND FENCE GROUND IS NOT SODDED HOLDING WATERLARGE TARP ON GROUND. ** LEFT REAR CORNER GROUND TORE UP FRONT LEFTT RUTS FROM MACHINE NEED TO BE REPAIRED ** CUT GRASS TO SEE THE CONTOURS OF LAND. 9/15/2022 - PREVIOUS INSPECTION NOTES ** 09/15/22 RIGHT REAR CORNER BETWEEN HOUSE AND FENCE LINE IS A LOW SPOT HAVING A PONDING OF WATER NEED TO RAISE WITH A POSITIVE FLOW TO THE FRONT TO DRAIN STORMWATER ** LEFT SIDE ALONG PROPERTY LINE OF CITY EASEMENT, NEEDS TO BE SODDED FOR EROSION CONTROL OF ALL BARE AREAS OF EARTH. ** LEFT SIDE BUILDER NEEDS TO REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM EASEMENT
BLD - BUILDING FINAL 10/13/2022 FINAL APPROVED MKRASKI
BLD - BUILDING FINAL 10/12/2022 CANCELLED BY APPLICANT MKRASKI
Note: New inspection due to canceled inspection 10/7/2022 - PREVIOUS INSPECTION NOTES Address number must be on home before final inspection
BLD - BUILDING FINAL 10/10/2022 CANCELLED BY APPLICANT WEB
Note: 10/7/2022 - PREVIOUS INSPECTION NOTES Address number must be on home before final inspection
BLD - BUILDING FINAL 10/07/2022 Disapproved - NO FEE MKRASKI
Note: Address number must be on home before final inspection
U -UTILITY RESIDENTIAL FINAL 09/20/2022 FINAL APPROVED LFITZGERALD
Note: 9/15/2022 - PREVIOUS INSPECTION NOTES sewer riser pipe for the clean out cap is cut at a 45 degree angle and cap was loose fitting upon inspection. It is uncertain if cap assembly is full fitting and there is a possibility that soils can/will flow into the sewer line where the gap is from the pipe being cut on this angle. I called both phone numbers on the permit hoping to receive a response but presenly no reply so we could maybe meet in the field and evaluate this issue. The best /proper solution is to cut pipe flush and see if cap is not to low once fitted. If too low then add a piece of pipe and make flush with grades.
BLD - BUILDING FINAL 09/16/2022 CANCELLED BY APPLICANT KSANDOE
ROW - STORMWATER FINAL 09/15/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 09/15/22 RIGHT REAR CORNER BETWEEN HOUSE AND FENCE LINE IS A LOW SPOT HAVING A PONDING OF WATER NEED TO RAISE WITH A POSITIVE FLOW TO THE FRONT TO DRAIN STORMWATER ** LEFT SIDE ALONG PROPERTY LINE OF CITY EASEMENT, NEEDS TO BE SODDED FOR EROSION CONTROL OF ALL BARE AREAS OF EARTH. ** LEFT SIDE BUILDER NEEDS TO REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM EASEMENT
ROW - FINAL APRON (AFTER POUR) 09/15/2022 APPROVED EMADISON
U -UTILITY RESIDENTIAL FINAL 09/15/2022 Disapproved - NO FEE LFITZGERALD
Note: sewer riser pipe for the clean out cap is cut at a 45 degree angle and cap was loose fitting upon inspection. It is uncertain if cap assembly is full fitting and there is a possibility that soils can/will flow into the sewer line where the gap is from the pipe being cut on this angle. I called both phone numbers on the permit hoping to receive a response but presenly no reply so we could maybe meet in the field and evaluate this issue. The best /proper solution is to cut pipe flush and see if cap is not to low once fitted. If too low then add a piece of pipe and make flush with grades.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/14/2022 APPROVED RGROSS
Note: Inspector Notes from Inspection 9270 **08/08/22= AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''' ** 08/05/22 FORM BOARDS ARE NOT IN PLACE AT THE TIME OF INSPECTION ** BAND NEEDS TO BE TURNED SO BOLTS ARE DOWN ALONG THE SIDE NOT ON TOP OF PIPE ** PHOTOS ATTACHED THIS IS A REINSPECTION ** 08/04/22 CULVERT PIPE IS OUT OF TOLERANCE 2.5 TENTHS HIGH ON LEFT SIDE ** MATERIAL AROUND PIPE IS TOO AND WET TO POUR NO COMPACTION Culvert too low in the center where the band is. 3 tenths lower than the culvert end on one side and 2 tenths lower than the culvert end on the other side.
ROW FIELD SURVEY /GRADING CERTIFICATION 09/14/2022 APPROVED RGROSS
Note: Inspector Notes from Inspection 9270 **08/08/22= AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''' ** 08/05/22 FORM BOARDS ARE NOT IN PLACE AT THE TIME OF INSPECTION ** BAND NEEDS TO BE TURNED SO BOLTS ARE DOWN ALONG THE SIDE NOT ON TOP OF PIPE ** PHOTOS ATTACHED THIS IS A REINSPECTION ** 08/04/22 CULVERT PIPE IS OUT OF TOLERANCE 2.5 TENTHS HIGH ON LEFT SIDE ** MATERIAL AROUND PIPE IS TOO AND WET TO POUR NO COMPACTION Culvert too low in the center where the band is. 3 tenths lower than the culvert end on one side and 2 tenths lower than the culvert end on the other side.
ROW- PRE-APRON (PRE-POUR) 08/08/2022 APPROVED - AS NOTED GBERTOLA
Note: **08/08/22= AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''' ** 08/05/22 FORM BOARDS ARE NOT IN PLACE AT THE TIME OF INSPECTION ** BAND NEEDS TO BE TURNED SO BOLTS ARE DOWN ALONG THE SIDE NOT ON TOP OF PIPE ** PHOTOS ATTACHED THIS IS A REINSPECTION ** 08/04/22 CULVERT PIPE IS OUT OF TOLERANCE 2.5 TENTHS HIGH ON LEFT SIDE ** MATERIAL AROUND PIPE IS TOO AND WET TO POUR NO COMPACTION Culvert too low in the center where the band is. 3 tenths lower than the culvert end on one side and 2 tenths lower than the culvert end on the other side.
ROW- PRE-APRON (PRE-POUR) 08/05/2022 Disapproved -FEE REQUIRED EMADISON
Note: THIS IS A REINSPECTION ** 08/05/22 FORM BOARDS ARE NOT IN PLACE AT THE TIME OF INSPECTION ** BAND NEEDS TO BE TURNED SO BOLTS ARE DOWN ALONG THE SIDE NOT ON TOP OF PIPE ** PHOTOS ATTACHED THIS IS A REINSPECTION ** 08/04/22 CULVERT PIPE IS OUT OF TOLERANCE 2.5 TENTHS HIGH ON LEFT SIDE ** MATERIAL AROUND PIPE IS TOO AND WET TO POUR NO COMPACTION Culvert too low in the center where the band is. 3 tenths lower than the culvert end on one side and 2 tenths lower than the culvert end on the other side.
ROW- PRE-APRON (PRE-POUR) 08/04/2022 Disapproved -FEE REQUIRED EMADISON
Note: THIS IS A REINSPECTION ** 08/04/22 CULVERT PIPE IS OUT OF TOLERANCE 2.5 TENTHS HIGH ON LEFT SIDE ** MATERIAL AROUND PIPE IS TOO AND WET TO POUR NO COMPACTION Culvert too low in the center where the band is. 3 tenths lower than the culvert end on one side and 2 tenths lower than the culvert end on the other side.
ELECTRIC - EARLY POWER 07/29/2022 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @0757. Release Power
ROW- PRE-APRON (PRE-POUR) 07/25/2022 Disapproved -FEE REQUIRED RGROSS
Note: Culvert too low in the center where the band is. 3 tenths lower than the culvert end on one side and 2 tenths lower than the culvert end on the other side.
LATH/BRICK/ WATER BARRIER 07/13/2022 APPROVED MKRASKI
INSULATION 06/23/2022 APPROVED MKRASKI
Note:
INSULATION 06/22/2022 Disapproved - NO FEE MKRASKI
Note: 6/22 1. Failed 5' head pressure test FBC P2503.5.1 2. Base plate on wood frame garage wall needs to be sealed
INSULATION 06/21/2022 Disapproved -FEE REQUIRED LMILLER
Note: still need the following from all-rough 1. Nail plate missing and romex not secure in strap on left wall of front entry marked with orange pain on stud (From all-rough) 2. No 5' head pressure present (from all-rough) 3. No exterior doors installed (from allrough)... these were installed but the slider track closest to the kitchen is missing screws
ALL ROUGH 06/03/2022 APPROVED - AS NOTED MKRASKI
Note: 1. Nail plate missing and romex not secure in strap on left wall of front entry marked with orange pain on stud 2. No 5' head pressure present 3. No exterior doors installed Check on insulation
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/02/2022 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/18/2022 Disapproved - NO FEE MKRASKI
Note: 1. load bearing wall achors not tighened down 2. several truss straps not attached around house
ROOF VALLEY & METAL 04/18/2022 APPROVED MKRASKI
ROOF SHEATHING 04/01/2022 APPROVED MKRASKI
WALL SHEATHING 03/31/2022 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/30/2022 Disapproved -FEE REQUIRED FWILLIS
Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL NO APPROVED PLANS ON SITE.
FOUND SURVEY APPROVED (OFFICE) 03/29/2022 APPROVED TBAKER
TIE BEAM / LINTEL 03/11/2022 APPROVED MKRASKI
MONOLITHIC SLAB 02/14/2022 APPROVED MKRASKI
PLUMBING 1ST ROUGH UNDERGROUND 02/03/2022 APPROVED MGIBSON
GRAVITY SEWER TEST 02/03/2022 APPROVED MGIBSON
U - SEWER TIE IN 02/03/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 01/28/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
BLD CANCEL 03/28/2022 03/29/2022
ENGIN1 COMPLETE 03/28/2022 03/29/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/28/2022 03/28/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC COMPLETE 11/04/2021 11/08/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC HOLD 11/01/2021 11/02/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need smoke alarm in master bedroom and outside of it. FRC 2020 314.3 2nd REQUEST
MECH COMPLETE 11/01/2021 11/02/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 11/01/2021 11/02/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD HOLD 10/11/2021 10/12/2021
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building REVIEW COMMENTS: 1. SP4 is called-out for bottom plate to stud connector in detail 2/F. Per Simpson, SP4 is to be used for a top plate application. A revision is required to provide a connector for the proposed use. 2. Typical Block Wall Section calls-out tile roofing. Product approval and roofing worksheet show asphalt shingles. Provide which is correct and revise to reflect the correct roofing materials to be used. 3. Provide Product Approval number for the proposed to be installed. Product installation instruction was submitted, with no approval number. a. Properly identify Florida Product Approval Number (i.e. 15332.#, 18644.#.); there are various types of approvals.
CUSVC COMPLETE 10/11/2021 10/14/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 10/11/2021 10/11/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need smoke alarm in master bedroom and outside of it. FRC 2020 314.3
ENGIN1 COMPLETE 10/11/2021 10/11/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 10/11/2021 10/12/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 10/11/2021 10/12/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide Energy Calcs from 2020 7Th edition code cycle
SW1 COMPLETE 10/11/2021 10/14/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
ZON COMPLETE 10/11/2021 10/12/2021
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 10/11/2021 12/13/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/20/2022
REINSPECTION RESIDENTIAL ¤40.00 12/20/2022
SW ENG REINSPECTION 20 ¤20.00 12/20/2022
SW ENG REINSPECTION 20 ¤20.00 12/20/2022
SW ENG REINSPECTION 30 ¤30.00 12/20/2022
SW ENG REINSPECTION 30 ¤30.00 12/20/2022
SW ENG REINSPECTION 30 ¤30.00 12/20/2022
SW ENG - REVIEW 20 ¤20.00 12/01/2021
SW ENG RES REVIEW 200 ¤200.00 12/01/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 12/01/2021
SEWER CREDIT (¤1,147.00) 12/01/2021
SEWER INSPECTION ¤25.00 12/01/2021
SEWER CAPITAL FACILITY ¤4,664.55 12/01/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 12/01/2021
SITE PLAN 30 ¤30.00 12/01/2021
CONNECTION FEES ¤1,017.83 12/01/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 12/01/2021
IMPACT FEE FIRE ¤367.00 12/01/2021
IMPACT FEE PARKS ¤1,199.12 12/01/2021
IMPACT FEE SCHOOL ¤3,600.00 12/01/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 12/01/2021
WATER -IRRIGATION INSPECTION ¤25.00 12/01/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 12/01/2021
SURCHARGE FS 533.721 ¤10.83 12/01/2021
SURCHARGE - FS 468.631 ¤16.24 12/01/2021
SW ENG - FOUNDATION SURVEY ¤20.00 12/01/2021
SW ENG INSPECTION 80 ¤80.00 12/01/2021
SW ENG PRE APRON ¤30.00 12/01/2021
METER - DEPOSIT ¤60.00 12/01/2021
WATER- TURN ON ¤25.00 12/01/2021
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/01/2021
INSPECTION - RESIDENTIAL ¤775.50 12/01/2021
PLAN REVIEW - RESIDENTIAL ¤219.96 12/01/2021
Fees Total Due: ¤0.00 Total Paid: ¤16,522.96