I want to search for...

Permit #2021100800

Permit Details

Status: COED

Parcel Id: 29-10-31-5540-00000-1350
CONDITIONED SPACE: 2665 sqft
GARAGE: 893 sqft
OPENED PORCH (WITH ROOF) : 367 sqft
OPENED PORCH (WITH ROOF) : 138 sqft
Total Square Footage: 4063 sqft
Block: 00000
Subdivision: 1005 - SANCTUARY SUBDIVISION
Job Phone: 386-931-6577
Location Address: 71 OLD OAK DR S
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/13/2022
NOC: RECORDED
Applicant name: LUIS JORGE MEDEIROS
Owner: SIGALOV SERGEI & SALIMA ARSHINOVA H&W

Address

209 RIVERSHIRE LANE #301

LINCOLNSHIRE, IL 60069

Lot: 1350
Contracted Stated Job Value: ¤350,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

A PLUS HOME IMPROVEMENTS LLC
Status Location Address State License Number Phone
ACTIVE

306 S RAILROAD ST

BUNNELL, FL 32110

CRC1327024 (Exp: 08/31/2026) 386-263-2167

Sub Contractors

JOSE E ORTIZ JR
Status Location Address Mailing Address State License Number Phone
CANCEL

4601 E MOODY BLVD

BUNNELL, FL 32110

SUITE B7

BUNNELL, FL 32110

RC29027619 (Exp: 08/31/2023) 386-503-6922
MIGUEL ANGEL GALLARDO
Status Location Address State License Number Phone
INACTIVE

315 PACER CT

SANFORD, FL 32773

CAC1813826 (Exp: 08/31/2026) 407-202-0953
JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/16/2024 FINAL APPROVED JWALKER
Note: New inspection due to canceled inspection 5/10/2024 - PREVIOUS INSPECTION NOTES 5/10/24: 1). Missing Locking port caps at ODU. (M1411.8) 2). Exterior Lineset sleeve needs to be sealed at the bottom. M1203.2.1 3). Exterior wall at low voltage lines needs to be sealed. 4). All holes in garage ceiling and walls need to be sealed. FBC R302.6 (Including holes for lineset above AHU). 5). MC cable for AHU is missing a cover & the approved fitting at the top. NEC 330.40 6). Breaker for Disconnect at AC (ODU) is not identified properly & the two breakers in the disconnect box need to be labeled as required. NEC 408.4 (A) 7). Range & dishwasher were not installed so the could not be checked. Also, there was no cooking appliance supplied. Inspector Notes from Inspection 2250 02-15-2024 Please have approved drawings on site for all inspections.
BLD - BUILDING FINAL 05/15/2024 CANCELLED BY APPLICANT WEB
Note: 5/10/2024 - PREVIOUS INSPECTION NOTES 5/10/24: 1). Missing Locking port caps at ODU. (M1411.8) 2). Exterior Lineset sleeve needs to be sealed at the bottom. M1203.2.1 3). Exterior wall at low voltage lines needs to be sealed. 4). All holes in garage ceiling and walls need to be sealed. FBC R302.6 (Including holes for lineset above AHU). 5). MC cable for AHU is missing a cover & the approved fitting at the top. NEC 330.40 6). Breaker for Disconnect at AC (ODU) is not identified properly & the two breakers in the disconnect box need to be labeled as required. NEC 408.4 (A) 7). Range & dishwasher were not installed so the could not be checked. Also, there was no cooking appliance supplied. Inspector Notes from Inspection 2250 02-15-2024 Please have approved drawings on site for all inspections.
BLD - BUILDING FINAL 05/10/2024 Disapproved -FEE REQUIRED RSIMS
Note: 5/10/24: 1). Missing Locking port caps at ODU. (M1411.8) 2). Exterior Lineset sleeve needs to be sealed at the bottom. M1203.2.1 3). Exterior wall at low voltage lines needs to be sealed. 4). All holes in garage ceiling and walls need to be sealed. FBC R302.6 (Including holes for lineset above AHU). 5). MC cable for AHU is missing a cover & the approved fitting at the top. NEC 330.40 6). Breaker for Disconnect at AC (ODU) is not identified properly & the two breakers in the disconnect box need to be labeled as required. NEC 408.4 (A) 7). Range & dishwasher were not installed so the could not be checked. Also, there was no cooking appliance supplied. Inspector Notes from Inspection 2250 02-15-2024 Please have approved drawings on site for all inspections.
ROW - STORMWATER FINAL 05/10/2024 APPROVED GBERTOLA
Note: 5/10/24= AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/3/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY EMADISON 5/3/2024 10:29:41 AM *** ** 05/03/24 BUILDER NEEDS TO FINISH LANDSCAPING AND COVER ALL BARE AREAS OF EARTH TO ASSIST IN PREVENTING ANY EROSION OF MATERIAL
U -UTILITY RESIDENTIAL FINAL 05/03/2024 FINAL APPROVED DHANEY
ROW - STORMWATER FINAL 05/03/2024 Disapproved - NO FEE EMADISON
Note: *** NOTES ADDED BY EMADISON 5/3/2024 10:29:41 AM *** ** 05/03/24 BUILDER NEEDS TO FINISH LANDSCAPING AND COVER ALL BARE AREAS OF EARTH TO ASSIST IN PREVENTING ANY EROSION OF MATERIAL
ROW - FINAL APRON (AFTER POUR) 05/03/2024 APPROVED EMADISON
Note: *** NOTES ADDED BY EMADISON 5/3/2024 10:23:17 AM *** ** 05/03/24 ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved.
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/02/2024 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 05/02/2024 APPROVED EMADISON
Note: ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved.
U-CROSS CONNECTION 05/02/2024 FINAL APPROVED LFITZGERALD
ELECTRIC - EARLY POWER 03/19/2024 APPROVED RMARTIN
ROW- PRE-APRON (PRE-POUR) 03/14/2024 APPROVED - AS NOTED FSLADISH
Note: 3/14/24 YOU ARE APPROVED TO LAY PAVERS AT THIS TIME. PER MY DISCUSSION WITH AMADEU IN THE FUTURE DO NOT DO ANY WORK WITHOUT THE INSPECTION APPROVED OR YOU WILL BE REQUIRED TO PULL THE PAVERS. PASSING AS NOTED DUE TO THE FACT I INSPECTED IT YESTERDAY AND EXCEPT FOR THE REAR FOOTER EVERYTHING WAS COMPLETED AND SPREAD AND COMPACTION WAS TO COPC STANDARDS. 3/13/2024 - PREVIOUS INSPECTION NOTES 1/11/2024 - PREVIOUS INSPECTION NOTES Approved for the Apron and Paver restraints only. Second pre pour will be needed after the base is down and compacted but BEFORE the pavers are placed. 1/10/2024 - PREVIOUS INSPECTION NOTES PAVER RESTRAINTS NEED TO BE A MINIMUM OF 4" WIDE AND 8" DEEP. NEED TO DIG OUT SO IT MEETS CITY'S STANDARDS --------------------------------------------------------------------------------------- 1/9/2024 - PREVIOUS INSPECTION NOTES COULD NOT DO INSPECTION THERE IS NO ADDRESS FOR THIS HOUSE DISPLAYED OR THE PERMIT BOX DOESN'T HAVE ANY PAPER WORK TO VERIFY IF THIS WAS THE RIGHT HOUSE ADDRESS MUST BE VISIBLE AT ALL TIMES OF THE CONSTRUCTION AND PERMIT BOX MUST HAVE ALL PAPER WORK IN THE PERMIT BOX AT ALL TIMES ------------------------------------------------------------------------------------ 1/5/2024 - PREVIOUS INSPECTION NOTES
ROW- PRE-APRON (PRE-POUR) 03/13/2024 CANCELLED BY APPLICANT FSLADISH
Note: 1/11/2024 - PREVIOUS INSPECTION NOTES Approved for the Apron and Paver restraints only. Second pre pour will be needed after the base is down and compacted but BEFORE the pavers are placed. 1/10/2024 - PREVIOUS INSPECTION NOTES PAVER RESTRAINTS NEED TO BE A MINIMUM OF 4" WIDE AND 8" DEEP. NEED TO DIG OUT SO IT MEETS CITY'S STANDARDS --------------------------------------------------------------------------------------- 1/9/2024 - PREVIOUS INSPECTION NOTES COULD NOT DO INSPECTION THERE IS NO ADDRESS FOR THIS HOUSE DISPLAYED OR THE PERMIT BOX DOESN'T HAVE ANY PAPER WORK TO VERIFY IF THIS WAS THE RIGHT HOUSE ADDRESS MUST BE VISIBLE AT ALL TIMES OF THE CONSTRUCTION AND PERMIT BOX MUST HAVE ALL PAPER WORK IN THE PERMIT BOX AT ALL TIMES ------------------------------------------------------------------------------------ 1/5/2024 - PREVIOUS INSPECTION NOTES
MONOLITHIC SLAB 02/15/2024 APPROVED - AS NOTED AGAETANO
Note: 02-15-2024 Please have approved drawings on site for all inspections.
GRAVITY SEWER TEST 01/26/2024 APPROVED AGAETANO
U - SEWER TIE IN 01/26/2024 APPROVED AGAETANO
ROW- PRE-APRON (PRE-POUR) 01/11/2024 PARTIALLY APPROVED RGROSS
Note: Approved for the Apron and Paver restraints only. Second pre pour will be needed after the base is down and compacted but BEFORE the pavers are placed. 1/10/2024 - PREVIOUS INSPECTION NOTES PAVER RESTRAINTS NEED TO BE A MINIMUM OF 4" WIDE AND 8" DEEP. NEED TO DIG OUT SO IT MEETS CITY'S STANDARDS --------------------------------------------------------------------------------------- 1/9/2024 - PREVIOUS INSPECTION NOTES COULD NOT DO INSPECTION THERE IS NO ADDRESS FOR THIS HOUSE DISPLAYED OR THE PERMIT BOX DOESN'T HAVE ANY PAPER WORK TO VERIFY IF THIS WAS THE RIGHT HOUSE ADDRESS MUST BE VISIBLE AT ALL TIMES OF THE CONSTRUCTION AND PERMIT BOX MUST HAVE ALL PAPER WORK IN THE PERMIT BOX AT ALL TIMES ------------------------------------------------------------------------------------ 1/5/2024 - PREVIOUS INSPECTION NOTES
ROW- PRE-APRON (PRE-POUR) 01/10/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: PAVER RESTRAINTS NEED TO BE A MINIMUM OF 4" WIDE AND 8" DEEP. NEED TO DIG OUT SO IT MEETS CITY'S STANDARDS --------------------------------------------------------------------------------------- 1/9/2024 - PREVIOUS INSPECTION NOTES COULD NOT DO INSPECTION THERE IS NO ADDRESS FOR THIS HOUSE DISPLAYED OR THE PERMIT BOX DOESN'T HAVE ANY PAPER WORK TO VERIFY IF THIS WAS THE RIGHT HOUSE ADDRESS MUST BE VISIBLE AT ALL TIMES OF THE CONSTRUCTION AND PERMIT BOX MUST HAVE ALL PAPER WORK IN THE PERMIT BOX AT ALL TIMES ------------------------------------------------------------------------------------ 1/5/2024 - PREVIOUS INSPECTION NOTES
ROW- PRE-APRON (PRE-POUR) 01/09/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: COULD NOT DO INSPECTION THERE IS NO ADDRESS FOR THIS HOUSE DISPLAYED OR THE PERMIT BOX DOESN'T HAVE ANY PAPER WORK TO VERIFY IF THIS WAS THE RIGHT HOUSE ADDRESS MUST BE VISIBLE AT ALL TIMES OF THE CONSTRUCTION AND PERMIT BOX MUST HAVE ALL PAPER WORK IN THE PERMIT BOX AT ALL TIMES ------------------------------------------------------------------------------------ 1/5/2024 - PREVIOUS INSPECTION NOTES
ROW- PRE-APRON (PRE-POUR) 01/05/2024 CANCELLED BY APPLICANT GBERTOLA
INSULATION 11/30/2023 APPROVED AGAETANO
LATH/BRICK/ WATER BARRIER 11/16/2023 APPROVED AGAETANO
Note: Inspector Notes from Inspection 2420 10/27/2023 8:05:11 AM- PREVIOUS INSPECTION NOTES 10/13/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 7/12/2023 - PREVIOUS INSPECTION NOTES 6/20/2023 - PREVIOUS INSPECTION NOTES 06/20/2023 1. Missing strapping in back area valley feaming 2. Sheathing blocking view of straps in entry way 3. Unable to read valley frame detail on plans PLEASE CALL FOR A SITE VISIT 386-986-7930-thomas 6/1/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES 05-17-2023 1. Drawings are faded, ripped, and unable to read on certain sheets. 2. Truss layout not on site. 3. Connector schedule not on site. Inspection stopped. 07-12-2023 1. Truss layout too small to read. 2. Drawings are blurry and cannot read details and print. 3. SD2 - Typical frame to Block Wall not installed as per plans. 4. B03 only one strap installed. 5. A20 only one strap installed. Inspection stopped. 10-11-2023 1. A01 girder not nailed per specs. 2. A03 only one strap. 3. Truss EJ7 #6 no strap. 4. Safe room, walk in closet, door 114. Please provide engineering for concrete ceiling. 5. G02 trusses at entry needs bucket connectors. 6. G03 at entry needs bucket connectors. 7. EJ5A at entry needs bucket connector. Check at all rough. 1. Approved electrical and mechanical plans not on site. 2. Dryer vent needs shield plate at top plate both sides. 3. Safe room, walk in closet, door 114. Please provide engineering for concrete ceiling by insulation. 4. Dryer vent not per code. M1502.4 Dryer exhaust ducts. Dryer exhaust ducts shall conform to the requirements of Sections M1502.4.1 through M1502.4.7. Cannot slope downwards. Inspection stopped. 11-9-2023 1. Dryer vent needs shield plates at top plate, both sides. 2. Please have approved, readable electrical plans on site for inspections. Check at next inspection.
ALL ROUGH 11/09/2023 APPROVED - AS NOTED AGAETANO
Note: 10/27/2023 8:05:11 AM- PREVIOUS INSPECTION NOTES 10/13/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 7/12/2023 - PREVIOUS INSPECTION NOTES 6/20/2023 - PREVIOUS INSPECTION NOTES 06/20/2023 1. Missing strapping in back area valley feaming 2. Sheathing blocking view of straps in entry way 3. Unable to read valley frame detail on plans PLEASE CALL FOR A SITE VISIT 386-986-7930-thomas 6/1/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES 05-17-2023 1. Drawings are faded, ripped, and unable to read on certain sheets. 2. Truss layout not on site. 3. Connector schedule not on site. Inspection stopped. 07-12-2023 1. Truss layout too small to read. 2. Drawings are blurry and cannot read details and print. 3. SD2 - Typical frame to Block Wall not installed as per plans. 4. B03 only one strap installed. 5. A20 only one strap installed. Inspection stopped. 10-11-2023 1. A01 girder not nailed per specs. 2. A03 only one strap. 3. Truss EJ7 #6 no strap. 4. Safe room, walk in closet, door 114. Please provide engineering for concrete ceiling. 5. G02 trusses at entry needs bucket connectors. 6. G03 at entry needs bucket connectors. 7. EJ5A at entry needs bucket connector. Check at all rough. 1. Approved electrical and mechanical plans not on site. 2. Dryer vent needs shield plate at top plate both sides. 3. Safe room, walk in closet, door 114. Please provide engineering for concrete ceiling by insulation. 4. Dryer vent not per code. M1502.4 Dryer exhaust ducts. Dryer exhaust ducts shall conform to the requirements of Sections M1502.4.1 through M1502.4.7. Cannot slope downwards. Inspection stopped. 11-9-2023 1. Dryer vent needs shield plates at top plate, both sides. 2. Please have approved, readable electrical plans on site for inspections. Check at next inspection.
ALL ROUGH 10/27/2023 CANCELLED BY APPLICANT MRAMOS
Note: 10/13/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 7/12/2023 - PREVIOUS INSPECTION NOTES 6/20/2023 - PREVIOUS INSPECTION NOTES 06/20/2023 1. Missing strapping in back area valley feaming 2. Sheathing blocking view of straps in entry way 3. Unable to read valley frame detail on plans PLEASE CALL FOR A SITE VISIT 386-986-7930-thomas 6/1/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES 05-17-2023 1. Drawings are faded, ripped, and unable to read on certain sheets. 2. Truss layout not on site. 3. Connector schedule not on site. Inspection stopped. 07-12-2023 1. Truss layout too small to read. 2. Drawings are blurry and cannot read details and print. 3. SD2 - Typical frame to Block Wall not installed as per plans. 4. B03 only one strap installed. 5. A20 only one strap installed. Inspection stopped. 10-11-2023 1. A01 girder not nailed per specs. 2. A03 only one strap. 3. Truss EJ7 #6 no strap. 4. Safe room, walk in closet, door 114. Please provide engineering for concrete ceiling. 5. G02 trusses at entry needs bucket connectors. 6. G03 at entry needs bucket connectors. 7. EJ5A at entry needs bucket connector. Check at all rough. 1. Approved electrical and mechanical plans not on site. 2. Dryer vent needs shield plate at top plate both sides. 3. Safe room, walk in closet, door 114. Please provide engineering for concrete ceiling by insulation. 4. Dryer vent not per code. M1502.4 Dryer exhaust ducts. Dryer exhaust ducts shall conform to the requirements of Sections M1502.4.1 through M1502.4.7. Cannot slope downwards. Inspection stopped.
ALL ROUGH 10/13/2023 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2460 7/12/2023 - PREVIOUS INSPECTION NOTES 6/20/2023 - PREVIOUS INSPECTION NOTES 06/20/2023 1. Missing strapping in back area valley feaming 2. Sheathing blocking view of straps in entry way 3. Unable to read valley frame detail on plans PLEASE CALL FOR A SITE VISIT 386-986-7930-thomas 6/1/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES 05-17-2023 1. Drawings are faded, ripped, and unable to read on certain sheets. 2. Truss layout not on site. 3. Connector schedule not on site. Inspection stopped. 07-12-2023 1. Truss layout too small to read. 2. Drawings are blurry and cannot read details and print. 3. SD2 - Typical frame to Block Wall not installed as per plans. 4. B03 only one strap installed. 5. A20 only one strap installed. Inspection stopped. 10-11-2023 1. A01 girder not nailed per specs. 2. A03 only one strap. 3. Truss EJ7 #6 no strap. 4. Safe room, walk in closet, door 114. Please provide engineering for concrete ceiling. 5. G02 trusses at entry needs bucket connectors. 6. G03 at entry needs bucket connectors. 7. EJ5A at entry needs bucket connector. Check at all rough. 1. Approved electrical and mechanical plans not on site. 2. Dryer vent needs shield plate at top plate both sides. 3. Safe room, walk in closet, door 114. Please provide engineering for concrete ceiling by insulation. 4. Dryer vent not per code. M1502.4 Dryer exhaust ducts. Dryer exhaust ducts shall conform to the requirements of Sections M1502.4.1 through M1502.4.7. Exceeds length. Cannot slope downwards. Please have a large, approved, readable, set of drawings on site for all inspections. Inspection stopped.
ELECTRIC-TUG 10/12/2023 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/11/2023 APPROVED - AS NOTED AGAETANO
Note: 7/12/2023 - PREVIOUS INSPECTION NOTES 6/20/2023 - PREVIOUS INSPECTION NOTES 06/20/2023 1. Missing strapping in back area valley feaming 2. Sheathing blocking view of straps in entry way 3. Unable to read valley frame detail on plans PLEASE CALL FOR A SITE VISIT 386-986-7930-thomas 6/1/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES 05-17-2023 1. Drawings are faded, ripped, and unable to read on certain sheets. 2. Truss layout not on site. 3. Connector schedule not on site. Inspection stopped. 07-12-2023 1. Truss layout too small to read. 2. Drawings are blurry and cannot read details and print. 3. SD2 - Typical frame to Block Wall not installed as per plans. 4. B03 only one strap installed. 5. A20 only one strap installed. Inspection stopped. 10-11-2023 1. A01 girder not nailed per specs. 2. A03 only one strap. 3. Truss EJ7 #6 no strap. 4. Safe room, walk in closet, door 114. Please provide engineering for concrete ceiling. 5. G02 trusses at entry needs bucket connectors. 6. G03 at entry needs bucket connectors. 7. EJ5A at entry needs bucket connector. Check at all rough.
ROOF VALLEY & METAL 09/27/2023 APPROVED AGAETANO
Note: 9/14/2023 - PREVIOUS INSPECTION NOTES 09-14-2023 1. Approximately half of roof is complete (tiles installed). 2. Areas of roof that does not have tiles installed is correct, provided the underlayment installed matches Roofing Worksheet. 3. Unable to identify underlayment installed. Please provide documentation that underlayment is installed as per roofing worksheet. 4. Roofing manufacturers specs not on site. Please have roofing manufacturer's specs on site. 5. Please provide engineering that batons are or are not needed.
ROOF VALLEY & METAL 09/14/2023 Disapproved - NO FEE AGAETANO
Note: 09-14-2023 1. Approximately half of roof is complete (tiles installed). 2. Areas of roof that does not have tiles installed is correct, provided the underlayment installed matches Roofing Worksheet. 3. Unable to identify underlayment installed. Please provide documentation that underlayment is installed as per roofing worksheet. 4. Roofing manufacturers specs not on site. Please have roofing manufacturer's specs on site. 5. Please provide engineering that batons are or are not needed.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/12/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 6/20/2023 - PREVIOUS INSPECTION NOTES 06/20/2023 1. Missing strapping in back area valley feaming 2. Sheathing blocking view of straps in entry way 3. Unable to read valley frame detail on plans PLEASE CALL FOR A SITE VISIT 386-986-7930-thomas 6/1/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES 05-17-2023 1. Drawings are faded, ripped, and unable to read on certain sheets. 2. Truss layout not on site. 3. Connector schedule not on site. Inspection stopped. 07-12-2023 1. Truss layout too small to read. 2. Drawings are blurry and cannot read details and print. 3. SD2 - Typical frame to Block Wall not installed as per plans. 4. B03 only one strap installd. 5. A20 only one strap installed. Inspection stopped.
ROOF SHEATHING 06/21/2023 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/20/2023 Disapproved - NO FEE TSTAUFFACHER
Note: 06/20/2023 1. Missing strapping in back area valley feaming 2. Sheathing blocking view of straps in entry way 3. Unable to read valley frame detail on plans PLEASE CALL FOR A SITE VISIT 386-986-7930-thomas 6/1/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES 05-17-2023 1. Drawings are faded, ripped, and unable to read on certain sheets. 2. Truss layout not on site. 3. Connector schedule not on site. Inspection stopped.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/01/2023 CANCELLED BY APPLICANT AGAETANO
Note: 5/17/2023 - PREVIOUS INSPECTION NOTES 05-17-2023 1. Drawings are faded, ripped, and unable to read on certain sheets. 2. Truss layout not on site. 3. Connector schedule not on site. Inspection stopped.
WALL SHEATHING 05/17/2023 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/17/2023 Disapproved - NO FEE AGAETANO
Note: 05-17-2023 1. Drawings are faded, ripped, and unable to read on certain sheets. Please provide a set of approved readble drawings for inspections. 2. Truss layout not on site. 3. Connector schedule not on site. Inspection stopped.
FOUND SURVEY APPROVED (OFFICE) 12/06/2022 APPROVED TBAKER
TIE BEAM / LINTEL 11/23/2022 APPROVED AGAETANO
Note: 11-23-2022 Plans are wet, dirty, moldy, and disorganized. Please provide a new clean set of approved drawings for inspections.
MONOLITHIC SLAB 09/26/2022 APPROVED FWILLIS
Note: THIS IS A REINSPECTION 09-07-2022 Contractor not ready.
PLUMBING 1ST ROUGH UNDERGROUND 09/13/2022 APPROVED MGIBSON
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION SPOKE WITH CONTRACTOR AND WAS TOLD HE DID NOT SCHEDULE THIS INSPECTION, WAS DONE VIA WEB. MASTER BATHROOM HAS NO VENT BETWEEN W/C AND BIDET AND FREE STANDING TUB. MAKE NECESSARY CORRECTIONS AND RESCHEDULE
PLUMBING 1ST ROUGH UNDERGROUND 09/08/2022 Disapproved -FEE REQUIRED MGIBSON
Note: THIS IS A REINSPECTION SPOKE WITH CONTRACTOR AND WAS TOLD HE DID NOT SCHEDULE THIS INSPECTION, WAS DONE VIA WEB. MASTER BATHROOM HAS NO VENT BETWEEN W/C AND BIDET AND FREE STANDING TUB. MAKE NECESSARY CORRECTIONS AND RESCHEDULE
MONOLITHIC SLAB 09/07/2022 Disapproved - NO FEE AGAETANO
Note: 09-07-2022 Contractor not ready.
STEM WALL FOUNDATION 07/19/2022 APPROVED DCUSHING
Note: THIS IS A REINSPECTION 1. Drawings are a matted mess and not readable. FP-1 foundation details are blurry and not readable. Please provide an approved set of readable drawings for inspection. 2. FP-1 foundation plan at F1 is not built as per plan. Noted on the right side of drawings.
STEM WALL FOUNDATION 07/15/2022 Disapproved - NO FEE AGAETANO
Note: 1. Drawings are a matted mess and not readable. FP-1 foundation details are blurry and not readable. Please provide an approved set of readable drawings for inspection. 2. FP-1 foundation plan at F1 is not built as per plan. Noted on the right side of drawings.
PLUMBING 1ST ROUGH UNDERGROUND 07/06/2022 CANCELLED BY APPLICANT MGIBSON
Note: SPOKE WITH CONTRACTOR AND WAS TOLD HE DID NOT SCHEDULE THIS INSPECTION, WAS DONE VIA WEB
FOOTER 04/28/2022 APPROVED AGAETANO
WATER METER INSTALLATION REQUEST 04/18/2022 APPROVED CSTONE
WILDLIFE CHECK - ENVIRONMENTAL 03/17/2022 APPROVED JMYERS

Review History

Department Status Date In Date Out
MECH COMPLETE 05/09/2024 05/14/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 01/24/2024 01/24/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Change of subcontractors are to be managed through the online portal. See page 56 of the 'how to' guide to change subcontractors and make inactive those that are no longer performing work on your project.
MECH COMPLETE 11/21/2023 11/27/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 11/08/2023 11/08/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 11/07/2023 11/07/2023
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME TO ENERGY CALCS.PDF
MECH HOLD 11/07/2023 11/07/2023
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
MECH COMPLETE 11/06/2023 11/06/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on Heatload needs to be Daytona Beach ( Third Request)
ELEC COMPLETE 11/06/2023 11/06/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 10/31/2023 10/31/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on Heatload needs to be Daytona Beach 2. Provide Duct layout signed by AC contractor 3. Update mechanical subcontractor 4. Revise Plan sheet 4. It shows Honest heating and air on duct layout.
BLD COMPLETE 10/23/2023 10/26/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 10/18/2023 10/23/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 10/18/2023 10/19/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on heatload needs to be Daytona Beach 2. Duct layout needs to be signed by the AC contractor. 3. Update mechanical subcontractor (Second Request)
MECH HOLD 06/12/2023 06/13/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on heatload needs to be Daytona Beach 2. Duct layout needs to be signed by the AC contractor. 3. Update mechanical subcontractor
ENGIN1 COMPLETE 12/05/2022 12/06/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/05/2022 12/05/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
PLENV COMPLETE 03/16/2022 03/17/2022
Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The Approved After Action Report has been accepted.
PLENV HOLD 02/16/2022 02/16/2022
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Staff conducted a site visit on 2/16/22 and found multiple Gopher Tortoise on the property. Please provide Approved After Action Report after relocation activities have been completed.
ZON COMPLETE 11/12/2021 11/12/2021
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 11/09/2021 11/10/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON HOLD 11/09/2021 11/12/2021
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Site plan and survey must show the walkway widths. If that is planters in front please show a setback from them to the front property line Please have notary write the owners names in the blank of the signatures that she is notarizing on right of way agreement
ELEC COMPLETE 10/29/2021 11/01/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON HOLD 10/29/2021 11/01/2021
Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Repeat comment: Roof: please provide a clear measurement of the roof pitch. Measurement on plans not readable
BLD HOLD 10/29/2021 11/01/2021
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Provide a completed City of Palm Coast Roofing Worksheet 2. Roofing wind zones on sheet GN are from a previous Code. A revision is required to reflect the current Code requirements. See Figure R301.2(7) 2020 Florida Building Code Residential 7th Edition.
ENGIN1 COMPLETE 10/29/2021 11/01/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 10/29/2021 11/08/2021
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON HOLD 10/21/2021 10/21/2021
Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Site plan and survey: Please provide walk way widths. also provide the total sq of lot. Does drive way with the pavers go all the way to apron. If so please provide a provide a Right of way utilization agreement for the paved drive way. The agreement must be signed by all owners on property deed, and notarized. landscaping plans: all required shrubs shall be planted 2.5 feet and 8 feet of the homes foundation please provide the distance. please make notes on the landscape plan St. Augustine grass requires irrigation. Roof: please provide a clead measurement of the roof pitch.
BLD HOLD 10/20/2021 10/22/2021
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Provide a completed City of Palm Coast Roofing Worksheet 2. Roofing wind zones on sheet GN are from a previous Code. A revision is required to reflect the current Code requirements. See Figure R301.2(7) 2020 Florida Building Code Residential 7th Edition.
CUSVC COMPLETE 10/20/2021 10/21/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 10/20/2021 10/21/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Electric load calcs do match the square footage of the house
ENGIN1 COMPLETE 10/20/2021 10/20/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 10/20/2021 10/22/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 10/20/2021 10/21/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 10/20/2021 10/26/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 05/21/2024
PLAN REVIEW - REVISION ¤32.50 05/21/2024
PLAN REVIEW - REVISION ¤32.50 05/21/2024
REINSPECTION RESIDENTIAL ¤40.00 05/21/2024
REINSPECTION RESIDENTIAL ¤40.00 05/21/2024
REINSPECTION RESIDENTIAL ¤40.00 05/21/2024
CONTRACTOR CHANGE ¤40.00 05/21/2024
CONTRACTOR CHANGE ¤20.00 05/21/2024
CONTRACTOR CHANGE ¤20.00 05/21/2024
IMPACT FEE FIRE ¤367.00 05/21/2024
IMPACT FEE PARKS ¤1,199.12 05/21/2024
IMPACT FEE TRANSPORTATION ¤3,139.00 05/21/2024
SW ENG REINSPECTION 30 ¤30.00 05/21/2024
SW ENG REINSPECTION 30 ¤30.00 05/21/2024
SW ENG - REVIEW 20 ¤20.00 01/13/2022
SW ENG RES REVIEW 200 ¤200.00 01/13/2022
SEWER INSPECTION ¤25.00 01/13/2022
SEWER CAPITAL FACILITY ¤4,939.76 01/13/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 01/13/2022
SITE PLAN 30 ¤30.00 01/13/2022
SURCHARGE FS 533.721 ¤13.29 01/13/2022
SURCHARGE - FS 468.631 ¤19.93 01/13/2022
SW ENG - FOUNDATION SURVEY ¤20.00 01/13/2022
SW ENG INSPECTION 80 ¤80.00 01/13/2022
SW ENG PRE APRON ¤30.00 01/13/2022
IMPACT FEE SCHOOL ¤3,600.00 01/13/2022
CONNECTION FEES ¤25.00 01/13/2022
METER - DEPOSIT ¤60.00 01/13/2022
WATER-METER ¤467.09 01/13/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/13/2022
INSPECTION - RESIDENTIAL ¤962.50 01/13/2022
PLAN REVIEW - RESIDENTIAL ¤273.00 01/13/2022
Fees Total Due: ¤0.00 Total Paid: ¤19,484.69