I want to search for...
Permit #2021100937
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-00320-0070 |
| CONDITIONED SPACE: 1941 sqft |
| GARAGE: 831 sqft |
| OPENED PORCH (WITH ROOF) : 378 sqft |
| OPENED PORCH (WITH ROOF) : 80 sqft |
| Total Square Footage: 3230 sqft |
| Block: 00320 |
| Subdivision: 2176 - SECTION 37-LAKEVIEW |
| Job Phone: (386) 445-2222 |
| Location Address: 40 LAMONT LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/23/2021 |
| NOC: RECORDED |
| Applicant name: MICHAEL STEPHAN MULLEN |
| Owner: ASHLEY J REYNOLDS & KENDALL S NIEMINEN |
|
Address 64 BROCKTO LANE PALM COAST, FL 32137 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤220,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
TOWN & COUNTRY HOMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1 Enterprise Drive Bunnell, FL 32110 |
CGC049972 (Exp: 08/31/2026) | (386) 445-2222 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
DENNIS GENE GAINEY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P.O. BOX 1203 Bunnell, FL 32110 |
CFC046004 (Exp: 08/31/2026) | (386) 437-5637 | 386-437-3012 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - STORMWATER FINAL | 12/08/2022 | FINAL APPROVED | EMADISON |
| Note: ** 12/08/22 CORRECTIONS MADE EVERYTHING LOOKS GOOD AT THE TIME OF THIS INSPECTION 12/5/2022 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection ** 12/05/22 AFTER SPEAKING WITH THE HOMEOWNER I HAD INFORMED HER THAT THAT GUTTER DRAINS ALL NEEDED TO STOP AT THE TOP OF THE ROW ABOUT 1 FOOT REAR AND POP-UP DRAINS SHOULD BE AS THE DRAINS CAN NOT DIRECTLY DISCHARGE INTO THE SWALE . ** THE LFET SIDE A SHED IS TO BE DELIVERED / BARE AREA WILL HAVE MILLINGS PUT DOWN . ** ANY QUESTIONS CONTACT EDWARD MADISON INSPECTOR (386)-286-2019 12/1/2022 - PREVIOUS INSPECTION NOTES ** 11/30/22 CORRECTIONS NEEDED BEFORE FINAL ROW IS APPROVE ** RIGHT SIDE FRONT 8 INCH DRAIN NEEDS TO BE REMOVED FROM THE ROW RECOMMEND USING A POP-UP DRAIN AT THE TOP OF THE ROW TO PREVENT EROSION TO THE SWALE, RIGHT SIDE PROPERTY LINE IN FRONT NEEDS ALL BARE AREAS OF EARTH SODDED 4 INCH DRAIN IN SWALE RIGHT FRONT NEEDS TO BE REMOVED FROM SWALE. ** LEFT SIDE REAR CORNER BARE EARTH AT HOUSE AND SLAB NEEDS TO BE SODDED ** LEFT SIDE 3 GUTTER DRAINS NEED TO BE REMOVED FROM SWALE TO TO OF ROW RECOMMEND THE USE OF POP-UP DRAINS TO PREVENT EROSION OF SWALE. | |||
| ROW - STORMWATER FINAL | 12/05/2022 | Disapproved -FEE REQUIRED | EMADISON |
| Note: New inspection due to canceled inspection ** 12/05/22 AFTER SPEAKING WITH THE HOMEOWNER I HAD INFORMED HER THAT THAT GUTTER DRAINS ALL NEEDED TO STOP AT THE TOP OF THE ROW ABOUT 1 FOOT REAR AND POP-UP DRAINS SHOULD BE AS THE DRAINS CAN NOT DIRECTLY DISCHARGE INTO THE SWALE . ** THE LFET SIDE A SHED IS TO BE DELIVERED / BARE AREA WILL HAVE MILLINGS PUT DOWN . ** ANY QUESTIONS CONTACT EDWARD MADISON INSPECTOR (386)-286-2019 12/1/2022 - PREVIOUS INSPECTION NOTES ** 11/30/22 CORRECTIONS NEEDED BEFORE FINAL ROW IS APPROVE ** RIGHT SIDE FRONT 8 INCH DRAIN NEEDS TO BE REMOVED FROM THE ROW RECOMMEND USING A POP-UP DRAIN AT THE TOP OF THE ROW TO PREVENT EROSION TO THE SWALE, RIGHT SIDE PROPERTY LINE IN FRONT NEEDS ALL BARE AREAS OF EARTH SODDED 4 INCH DRAIN IN SWALE RIGHT FRONT NEEDS TO BE REMOVED FROM SWALE. ** LEFT SIDE REAR CORNER BARE EARTH AT HOUSE AND SLAB NEEDS TO BE SODDED ** LEFT SIDE 3 GUTTER DRAINS NEED TO BE REMOVED FROM SWALE TO TO OF ROW RECOMMEND THE USE OF POP-UP DRAINS TO PREVENT EROSION OF SWALE. | |||
| ROW - STORMWATER FINAL | 12/02/2022 | CANCELLED BY APPLICANT | WEB |
| Note: 12/1/2022 - PREVIOUS INSPECTION NOTES ** 11/30/22 CORRECTIONS NEEDED BEFORE FINAL ROW IS APPROVE ** RIGHT SIDE FRONT 8 INCH DRAIN NEEDS TO BE REMOVED FROM THE ROW RECOMMEND USING A POP-UP DRAIN AT THE TOP OF THE ROW TO PREVENT EROSION TO THE SWALE, RIGHT SIDE PROPERTY LINE IN FRONT NEEDS ALL BARE AREAS OF EARTH SODDED 4 INCH DRAIN IN SWALE RIGHT FRONT NEEDS TO BE REMOVED FROM SWALE. ** LEFT SIDE REAR CORNER BARE EARTH AT HOUSE AND SLAB NEEDS TO BE SODDED ** LEFT SIDE 3 GUTTER DRAINS NEED TO BE REMOVED FROM SWALE TO TO OF ROW RECOMMEND THE USE OF POP-UP DRAINS TO PREVENT EROSION OF SWALE. | |||
| TUB SET | 12/02/2022 | APPROVED | MGIBSON |
| BLD - BUILDING FINAL | 12/02/2022 | FINAL APPROVED | RMARTIN |
| Note: 12/1/2022 - PREVIOUS INSPECTION NOTES NO HOT WATER IN HOME | |||
| U-CROSS CONNECTION | 12/02/2022 | APPROVED | DHANEY |
| BLD - BUILDING FINAL | 12/01/2022 | Disapproved - NO FEE | RMARTIN |
| Note: NO HOT WATER IN HOME | |||
| U -UTILITY RESIDENTIAL FINAL | 12/01/2022 | FINAL APPROVED | DHANEY |
| ROW - STORMWATER FINAL | 12/01/2022 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 11/30/22 CORRECTIONS NEEDED BEFORE FINAL ROW IS APPROVE ** RIGHT SIDE FRONT 8 INCH DRAIN NEEDS TO BE REMOVED FROM THE ROW RECOMMEND USING A POP-UP DRAIN AT THE TOP OF THE ROW TO PREVENT EROSION TO THE SWALE, RIGHT SIDE PROPERTY LINE IN FRONT NEEDS ALL BARE AREAS OF EARTH SODDED 4 INCH DRAIN IN SWALE RIGHT FRONT NEEDS TO BE REMOVED FROM SWALE. ** LEFT SIDE REAR CORNER BARE EARTH AT HOUSE AND SLAB NEEDS TO BE SODDED ** LEFT SIDE 3 GUTTER DRAINS NEED TO BE REMOVED FROM SWALE TO TO OF ROW RECOMMEND THE USE OF POP-UP DRAINS TO PREVENT EROSION OF SWALE. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/30/2022 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/30/2022 | APPROVED | EMADISON |
| Note: ** 11/30/22 CORRECTIONBS NEEDED BEFORE FINAL ROW IS APPROVE ** RIGHT SIDE FRONT 8 INCH DRAIN NEEDS TO BE REMOVED FROM THE ROW RECOMMEND USING A POP-UP DRAIN AT THE TOP OF THE ROW TO PREVENT EROSION TO THE SWALE, RIGHT SIDE PROPERTY LINE IN FRONT NEEDS ALL BARE AREAS OF EARTH SODDED ** LEFT SIDE REAR CORNER BARE EARTH AT HOUSE AND SLAB NEEDS TO BE SODDED ** LEFT SIDE 3 GUTTER DRAINS NEED TO BE REMOVED FROM SWALE TO TO OF ROW RECOMMEND THE USE OF POP-UP DRAINS TO PREVENT EROSION OF SWALE. | |||
| ROW - FINAL APRON (AFTER POUR) | 11/30/2022 | FINAL APPROVED | EMADISON |
| ROW- PRE-APRON (PRE-POUR) | 10/11/2022 | APPROVED | EMADISON |
| Note: ** 10/11/22 AT THE TIME OF THE INSPECTION EVERYTHING LOOKS GOOD READY TO POUR 9/23/2022 - PREVIOUS INSPECTION NOTES 9/19/2022 - PREVIOUS INSPECTION NOTES ** 09/19/22 ENTIRE POUR AREA NOT READY FORM BOARDS NOT SET UP. ** TOO MUCH WATER IN APRON AREA PIPE FULL OF WATER/ APRON IS TOO SOFT FOOT SINKS 3-5 INCHES ** SEE ATTACHED PHOTOS 9/14/2022 - PREVIOUS INSPECTION NOTES ** 09/14/22 APRON AREA IS TO SOFT AND WET TO POUR FOOT SINKING 4-6 INCHES INTO MUD CULVERT HAS MATERIAL WASHED OUT AND IN SOME AREAS TOO MUCH MATERIAL NEEDS TO BE BURIED 1/2 WAY UP CULVERT WITH COMPACTION. | |||
| ELECTRIC - EARLY POWER | 09/26/2022 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 9:45 AM | |||
| ELECTRIC - EARLY POWER | 09/23/2022 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 9/21/2022 - PREVIOUS INSPECTION NOTES PEP TANK WIRE NEEDS TO BE SAFED OFF 9/23/22 Power not safed off | |||
| ROW- PRE-APRON (PRE-POUR) | 09/23/2022 | Disapproved -FEE REQUIRED | RGROSS |
| Note: 9/19/2022 - PREVIOUS INSPECTION NOTES ** 09/19/22 ENTIRE POUR AREA NOT READY FORM BOARDS NOT SET UP. ** TOO MUCH WATER IN APRON AREA PIPE FULL OF WATER/ APRON IS TOO SOFT FOOT SINKS 3-5 INCHES ** SEE ATTACHED PHOTOS 9/14/2022 - PREVIOUS INSPECTION NOTES ** 09/14/22 APRON AREA IS TO SOFT AND WET TO POUR FOOT SINKING 4-6 INCHES INTO MUD CULVERT HAS MATERIAL WASHED OUT AND IN SOME AREAS TOO MUCH MATERIAL NEEDS TO BE BURIED 1/2 WAY UP CULVERT WITH COMPACTION. | |||
| U - SEWER TIE IN | 09/21/2022 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 09/21/2022 | APPROVED | MGIBSON |
| ELECTRIC - EARLY POWER | 09/21/2022 | Disapproved - NO FEE | RMARTIN |
| Note: PEP TANK WIRE NEEDS TO BE SAFED OFF | |||
| ROW- PRE-APRON (PRE-POUR) | 09/19/2022 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 09/19/22 ENTIRE POUR AREA NOT READY FORM BOARDS NOT SET UP. ** TOO MUCH WATER IN APRON AREA PIPE FULL OF WATER/ APRON IS TOO SOFT FOOT SINKS 3-5 INCHES ** SEE ATTACHED PHOTOS 9/14/2022 - PREVIOUS INSPECTION NOTES ** 09/14/22 APRON AREA IS TO SOFT AND WET TO POUR FOOT SINKING 4-6 INCHES INTO MUD CULVERT HAS MATERIAL WASHED OUT AND IN SOME AREAS TOO MUCH MATERIAL NEEDS TO BE BURIED 1/2 WAY UP CULVERT WITH COMPACTION. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/14/2022 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 09/14/22 APRON AREA IS TO SOFT AND WET TO POUR FOOT SINKING 4-6 INCHES INTO MUD CULVERT HAS MATERIAL WASHED OUT AND IN SOME AREAS TOO MUCH MATERIAL NEEDS TO BE BURIED 1/2 WAY UP CULVERT WITH COMPACTION. | |||
| PEP TANK INSTALLATION REQUEST | 08/31/2022 | APPROVED | CSTONE |
| LATH/BRICK/ WATER BARRIER | 08/09/2022 | APPROVED | RMARTIN |
| INSULATION | 07/25/2022 | APPROVED | FWILLIS |
| ALL ROUGH | 07/08/2022 | APPROVED | DCUSHING |
| Note: THIS IS A REINSPECTION 1. Nail plate needed for Spare bathroom vanity sink FBC P2503.5.1 2. Master bath room needs nail plates on water line FBC P2503.5.1 3. Fail 5' head pressure 4. Dryer vent needss to be sealed at all seams 5. Dryer vent needs nail plates FBC M15502.5 6. Master bathroom toliet needs Nail plate FBC 2503.5.1 7. Master bathroom exhaust fans vents need to be seperated or show manufacturer specs that shows it is allowable 8. Need repair engineering for truss T-19 and T-13 on site ALL ITEMS ADDRESSED - ENGINEERING BEFORE INSULATION | |||
| ALL ROUGH | 07/06/2022 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Nail plate needed for Spare bathroom vanity sink FBC P2503.5.1 2. Master bath room needs nail plates on water line FBC P2503.5.1 3. Fail 5' head pressure 4. Dryer vent needss to be sealed at all seams 5. Dryer vent needs nail plates FBC M15502.5 6. Master bathroom toliet needs Nail plate FBC 2503.5.1 7. Master bathroom exhaust fans vents need to be seperated or show manufacturer specs that shows it is allowable 8. Need repair engineering for truss T-19 and T-13 on site | |||
| WALL SHEATHING | 07/05/2022 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/30/2022 | APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION ROOF SHEATHING ONLY. STILL NEEDS BRACES, TIES AND DOWNCELL INSPECTION 5/9/22 - NEED ENGINEER LETTER FOR WOODEN BOXBEAM ON TOP OF BLOCK WORK IN GARAGE. INCLUDES ALL STRAPPING TO TRUSSES AND BLOCK. *NEED TO SEE DETAILS FOR BEARING WALLS, DOOR OPENINGS, HEADER, IN GARAGE. *TRUSS LAYOUT MISSING FROM ENGINEERING AND APPROVED PLANS. 6/16/22 - PAGES 5/6 AND 6/6 ON APPROVED PLANS SHOW SP'S TOP AND BOTTOM ON LOAD BEARING WALLS. ALSO SHOWS WALLS UNDER 8' HAVE 2 JACKS AND ON PAGE 5/6 WALLS UNDER 9' HAVING 2 STUDS. STRAPPING FOR BOX BEAM I COULD NOT FIND. BOX BEAM IS CLOSED, COULD NOT SEE CONNECTIONS, TOP PLATE OR ANCHOR BOLTS IF REQUIRED. INSPECTION NOT COMPLETE. 6/24/22 - DETAIL FOR BOX BEAM APPROVED AND NOTED. NEED BOX BEAM OPEN ON LEFT SIDE OF GARAGE WALL TO VIEW FOR APPROVED DETAILS. 06-27-2022 1. Truss plan not on site. 2. Back 8 x 8 O.H. door revised detail shows straps to CMU. No straps installed. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/27/2022 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION ROOF SHEATHING ONLY. STILL NEEDS BRACES, TIES AND DOWNCELL INSPECTION 5/9/22 - NEED ENGINEER LETTER FOR WOODEN BOXBEAM ON TOP OF BLOCK WORK IN GARAGE. INCLUDES ALL STRAPPING TO TRUSSES AND BLOCK. *NEED TO SEE DETAILS FOR BEARING WALLS, DOOR OPENINGS, HEADER, IN GARAGE. *TRUSS LAYOUT MISSING FROM ENGINEERING AND APPROVED PLANS. 6/16/22 - PAGES 5/6 AND 6/6 ON APPROVED PLANS SHOW SP'S TOP AND BOTTOM ON LOAD BEARING WALLS. ALSO SHOWS WALLS UNDER 8' HAVE 2 JACKS AND ON PAGE 5/6 WALLS UNDER 9' HAVING 2 STUDS. STRAPPING FOR BOX BEAM I COULD NOT FIND. BOX BEAM IS CLOSED, COULD NOT SEE CONNECTIONS, TOP PLATE OR ANCHOR BOLTS IF REQUIRED. INSPECTION NOT COMPLETE. 6/24/22 - DETAIL FOR BOX BEAM APPROVED AND NOTED. NEED BOX BEAM OPEN ON LEFT SIDE OF GARAGE WALL TO VIEW FOR APPROVED DETAILS. 06-27-2022 1. Truss plan not on site. 2. Back 8 x 8 O.H. door revised detail shows straps to CMU. No straps installed. Please provide details for O.H. door at gable truss strapping. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/24/2022 | Disapproved - NO FEE | FWILLIS |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION ROOF SHEATHING ONLY. STILL NEEDS BRACES, TIES AND DOWNCELL INSPECTION 5/9/22 - NEED ENGINEER LETTER FOR WOODEN BOXBEAM ON TOP OF BLOCK WORK IN GARAGE. INCLUDES ALL STRAPPING TO TRUSSES AND BLOCK. *NEED TO SEE DETAILS FOR BEARING WALLS, DOOR OPENINGS, HEADER, IN GARAGE. *TRUSS LAYOUT MISSING FROM ENGINEERING AND APPROVED PLANS. 6/16/22 - PAGES 5/6 AND 6/6 ON APPROVED PLANS SHOW SP'S TOP AND BOTTOM ON LOAD BEARING WALLS. ALSO SHOWS WALLS UNDER 8' HAVE 2 JACKS AND ON PAGE 5/6 WALLS UNDER 9' HAVING 2 STUDS. STRAPPING FOR BOX BEAM I COULD NOT FIND. BOX BEAM IS CLOSED, COULD NOT SEE CONNECTIONS, TOP PLATE OR ANCHOR BOLTS IF REQUIRED. INSPECTION NOT COMPLETE. 6/24/22 - DETAIL FOR BOX BEAM APPROVED AND NOTED. NEED BOX BEAM OPEN ON LEFT SIDE OF GARAGE WALL TO VIEW FOR APPROVED DETAILS. | |||
| ELECTRIC-TUG | 06/17/2022 | APPROVED - AS NOTED | JMUNSON |
| Note: Emailed FPL at 8:53 am | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/16/2022 | Disapproved - NO FEE | FWILLIS |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION ROOF SHEATHING ONLY. STILL NEEDS BRACES, TIES AND DOWNCELL INSPECTION 5/9/22 - NEED ENGINEER LETTER FOR WOODEN BOXBEAM ON TOP OF BLOCK WORK IN GARAGE. INCLUDES ALL STRAPPING TO TRUSSES AND BLOCK. *NEED TO SEE DETAILS FOR BEARING WALLS, DOOR OPENINGS, HEADER, IN GARAGE. *TRUSS LAYOUT MISSING FROM ENGINEERING AND APPROVED PLANS. 6/16/22 - PAGES 5/6 AND 6/6 ON APPROVED PLANS SHOW SP'S TOP AND BOTTOM ON LOAD BEARING WALLS. ALSO SHOWS WALLS UNDER 8' HAVE 2 JACKS AND ON PAGE 5/6 WALLS UNDER 9' HAVING 2 STUDS. STRAPPING FOR BOX BEAM I COULD NOT FIND. BOX BEAM IS CLOSED, COULD NOT SEE CONNECTIONS, TOP PLATE OR ANCHOR BOLTS IF REQUIRED. INSPECTION NOT COMPLETE. | |||
| ROOF VALLEY & METAL | 06/10/2022 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/09/2022 | Disapproved - NO FEE | FWILLIS |
| Note: THIS IS A REINSPECTION ROOF SHEATHING ONLY. STILL NEEDS BRACES, TIES AND DOWNCELL INSPECTION 5/9/22 - NEED ENGINEER LETTER FOR WOODEN BOXBEAM ON TOP OF BLOCK WORK IN GARAGE. INCLUDES ALL STRAPPING TO TRUSSES AND BLOCK. *NEED TO SEE DETAILS FOR BEARING WALLS, DOOR OPENINGS, HEADER, IN GARAGE. *TRUSS LAYOUT MISSING FROM ENGINEERING AND APPROVED PLANS. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/03/2022 | PARTIALLY APPROVED | FWILLIS |
| Note: ROOF SHEATHING ONLY. STILL NEEDS BRACES, TIES AND DOWNCELL INSPECTION | |||
| TIE BEAM / LINTEL | 04/06/2022 | APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION REBAR MISSING WHERE MARKED ON THE WALL. D&R DRILL AND EPOXY 4/6/22 - ITEMS CORRECTED | |||
| TIE BEAM / LINTEL | 04/05/2022 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: REBAR MISSING WHERE MARKED ON THE WALL. D&R DRILL AND EPOXY | |||
| FOUND SURVEY APPROVED (OFFICE) | 03/14/2022 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 02/22/2022 | APPROVED - AS NOTED | RMARTIN |
| Note: builder sent in proof of compaction | |||
| MONOLITHIC SLAB | 02/16/2022 | Disapproved - NO FEE | FWILLIS |
| Note: NEED PROOF OF COMPACTION TEST ON SITE. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/11/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 01/31/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/11/2022 | 07/11/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/10/2022 | 06/10/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/11/2022 | 03/14/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/11/2022 | 03/11/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/18/2021 | 11/19/2021 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/18/2021 | 11/19/2021 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/12/2021 | 11/12/2021 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please indicate the type of oak trees being planted to assure you have at least one shade tree. A scrub oak would be considered an understory tree. | |||
| BLD | HOLD | 11/12/2021 | 11/12/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Correction: Submited FL 1644-R4 and FL1392 - R4 (Mitek) for Wood Anchors on Structural Components are still incorrect. They are engineered wood/lumber not metal connectors. Please refer to previous note. You can use only one (1) FL No. for each type. | |||
| CUSVC | COMPLETE | 11/04/2021 | 11/05/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| MECH | COMPLETE | 11/04/2021 | 11/05/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 11/04/2021 | 11/10/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comments: 1. Okay. 2. Structural component for wood connectors, wood anchors and truss plates are missing on approval listing. Note: New comment - 11-10-21- The FL numbers submited for item 2 above appears to be a lumber or wood. The wood connectors/anchors refer to the metal connectors supporting the wood/lumber normally a Simpson Strong - Tie (manufacturer). | |||
| ZON | HOLD | 11/04/2021 | 11/05/2021 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Plantings and shrubbery Residential homes shall provide a foundation plantings consisting of 16 shrubs on interior lots. Eight shrubs shall be planted in front of home and four shrubs planted on each side of the home. The corners of the home shall be wrapped with shrubbery or have an understory tree planted there. Corner lots On corner lots (six) shrubs shall be planted on side of home facing a street 8 along the front and on the street side there must be 6 shrubs but that does not include the shrubs covering the mechanical equiptment please add two more shrubs on the street side maybe toward the other end. | |||
| SWALE | COMPLETE | 10/22/2021 | 12/28/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/21/2021 | 10/22/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM 1. Sheet 5 of 6: a. Typical Block Wall Section shows tile roof, unvented soffit and foam insulation incorrecly located. Coordinate with Roofing Worksheet. 2. Structural component for wood connectors, wood anchors and truss plates are missing on approval listing. | |||
| CUSVC | HOLD | 10/21/2021 | 10/22/2021 |
| Note: Held By: HALEIGH HAND - - Please correct the utility application to reflect the parcel number and property address of the new build. | |||
| ELEC | COMPLETE | 10/21/2021 | 10/22/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/21/2021 | 10/22/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 10/21/2021 | 10/25/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/21/2021 | 10/22/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show R5 on block walls. Energy Calcs say R9. Revise to match. 2. Square footage on heatload does not match the house plans. | |||
| SW1 | COMPLETE | 10/21/2021 | 10/26/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/21/2021 | 10/22/2021 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Plantings and shrubbery Residential homes shall provide a foundation plantings consisting of 16 shrubs on interior lots. Eight shrubs shall be planted in front of home and four shrubs planted on each side of the home. The corners of the home shall be wrapped with shrubbery or have an understory tree planted there. Corner lots On corner lots (six) shrubs shall be planted on side of home facing a street Trees One tree for every 2500 square ft. All calculations are rounded to the nearest whole number. This property requires 5. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 12/08/2022 |
| PLAN REVIEW - REVISION | ¤32.50 | 12/08/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/08/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/08/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/08/2022 |
| SW ENG REINSPECTION 20 | ¤20.00 | 12/08/2022 |
| SW ENG REINSPECTION 20 | ¤20.00 | 12/08/2022 |
| SW ENG REINSPECTION 30 | ¤30.00 | 12/08/2022 |
| SW ENG REINSPECTION 30 | ¤30.00 | 12/08/2022 |
| SW ENG REINSPECTION 30 | ¤30.00 | 12/08/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 11/23/2021 |
| SW ENG RES REVIEW 200 | ¤200.00 | 11/23/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 11/23/2021 |
| SEWER CREDIT | (¤2,326.05) | 11/23/2021 |
| SEWER INSPECTION | ¤25.00 | 11/23/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 11/23/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 11/23/2021 |
| SITE PLAN 30 | ¤30.00 | 11/23/2021 |
| METER - DEPOSIT | ¤60.00 | 11/23/2021 |
| WATER- TURN ON | ¤25.00 | 11/23/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/23/2021 |
| INSPECTION - RESIDENTIAL | ¤739.75 | 11/23/2021 |
| PLAN REVIEW - RESIDENTIAL | ¤209.82 | 11/23/2021 |
| CONNECTION FEES | ¤1,017.83 | 11/23/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 11/23/2021 |
| IMPACT FEE FIRE | ¤388.65 | 11/23/2021 |
| IMPACT FEE PARKS | ¤1,455.13 | 11/23/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 11/23/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 11/23/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 11/23/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 11/23/2021 |
| SURCHARGE FS 533.721 | ¤10.35 | 11/23/2021 |
| SURCHARGE - FS 468.631 | ¤15.53 | 11/23/2021 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 11/23/2021 |
| SW ENG INSPECTION 80 | ¤80.00 | 11/23/2021 |
| SW ENG PRE APRON | ¤30.00 | 11/23/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,671.16 |