I want to search for...
Permit #2021101027
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7003-00060-0130 |
| Block: 00060 |
| Subdivision: 2190 - SECTION 3-COUNTRY CLUB COVE |
| Job Phone: 386-327-6937 |
| Location Address: 26 CLEARVIEW CT S |
| Type: SLRE - SOLAR ELECTRIC - PHOTOVOLTAIC |
| Issue Date: 11/13/2021 |
| NOC: RECORDED |
| Applicant name: ROBERT JAMES RIHERD |
| Owner: HEARNE ROBERT P & CAROL L HEARNE H&W |
|
Address 26 CLEARVIEW CT PALM COAST, FL 32137 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤16,100.00 |
| Job Description: ROOFTOP SOLAR SYSTEM |
| Type: CN |
Contractor
EMPOWER SOLAR SOLUTIONS
| Status | Location Address | State License Number | Phone |
| INACTIVE |
100 E GRANADA BLVD ORMOND BEACH, FL 32176 |
CVC57067 (Exp: 08/31/2024) | 386-327-6937 |
Inspection History
| Type | Request Date | Result | Inspector |
| SOLAR ELECTRIC FINAL | 12/17/2021 | FINAL APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1. Plans call for a 40 amp breaker in panel There is no breaker in panel. 2. Warning label needs to be put on disconnect by meter according to plans. 3. Solar panal location and number does not match plans. 12/13/21 Rang door bell twice no answer need to verify breaker in panel | |||
| SOLAR ELECTRIC FINAL | 12/13/2021 | Disapproved - NO FEE | JMUNSON |
| Note: THIS IS A REINSPECTION 1. Plans call for a 40 amp breaker in panel There is no breaker in panel. 2. Warning label needs to be put on disconnect by meter according to plans. 3. Solar panal location and number does not match plans. 12/13/21 Rang door bell twice no answer need to verify breaker in panel | |||
| SOLAR ELECTRIC FINAL | 12/07/2021 | Disapproved -FEE REQUIRED | JMUNSON |
| Note: 1. Plans call for a 40 amp breaker in panel There is no breaker in panel. 2. Warning label needs to be put on disconnect by meter according to plans. 3. Solar panal location and number does not match plans. | |||
| SOLAR ELECTRIC FINAL | 12/06/2021 | CANCELLED BY APPLICANT | RMARTIN |
Review History
| Department | Status | Date In | Date Out |
| BLD | HOLD | 11/12/2021 | 11/12/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/12/2021 | 11/12/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/25/2021 | 10/25/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS 1. Provide an Engineers Letter certifying the Existing Structure can support the proposed loads from the proposed Photovoltaic System. Engineer stated Section 1607 of the Florida Building Code. Please see Section R324.4.4 Structural Requirements, 2020 Florida Building Code Residential, 7th Edition | |||
| ELEC | COMPLETE | 10/25/2021 | 10/25/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/09/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 11/13/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 11/13/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/13/2021 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 11/13/2021 |
| SOLAR PLAN REVIEW | ¤65.00 | 11/13/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤199.00 |