I want to search for...

Permit #2021110400

Permit Details

Status: EXPIRED

Parcel Id: 07-11-31-7002-00060-0130
Total Square Footage: 742 sqft
Block: 00060
Subdivision: 2218 - SECTION 2-FLORIDA PARK
Job Phone: 908-334-6117
Location Address: 16 FELICIA CT
Type: BA - BUILDING ADDITION
Issue Date: 01/26/2022
NOC: RECORDED
Applicant name: KIM EUGENE ADAMS
Owner: CASTELLO RONALD S & JOSEPHINE A SANCHEZ CASTELLO H

Address

16 FELICIA COURT

PALM COAST, FL 32137

Lot: 0130
Contracted Stated Job Value: ¤15,000.00
Job Description: Addition
Type: CN

Contractor

JMD QUALITY CONSTRUCTION, LLC
Status Location Address State License Number Phone
ACTIVE

300 CANOPY WALK LANE APT 342

ZEPHYRHILLS, FL 33542

CGC1526854 (Exp: 08/31/2026) 908-334-6117

Sub Contractors

MISHA ROMANOVSKIY
Status Location Address State License Number Phone Fax
INACTIVE

77 PEBBLE BEACH DRIVE

PALM COAST, FL 32164

ER13015548 (Exp: 08/31/2024) 386-793-5553 386-961-4388
DANIEL GOULDNER
Status Location Address State License Number
ACTIVE

400 OLD HAW CREEK RD

BUNNELL, FL 32110

CAC1818907 (Exp: 08/31/2026)
GIOVANNI DISARRO
Status Location Address State License Number
INACTIVE

107 BURROUGHS DRIVE

PALM COAST, FL 32137

CFC1430761 (Exp: 08/31/2026)

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/04/2024 Disapproved - NO FEE HCAMACHO
Note: 1. Need to submitt Energy Calcs to City building department. 2. Facia covering is missing and coming apart in several areas. 3. outlet in kitchen is not GFCI Protected 4. Missing notice to onwer A/C in attic. 5. Missing termite sticker. 6. Revise plans to show new location of A/C, attic access, and new kitchen layout. 7. Spoke with contractor 8. Resident living in the addition. 5/10/2024 - PREVIOUS INSPECTION NOTES 5-10-24 energy calcs model numbers not matching (revision needed) FBC 107.3 need trim around attic access FBC. R807.1 6/21/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2490 THIS IS A REINSPECTION Inspector Notes from Inspection 2420 THIS IS A REINSPECTION 1. Windows and doors not installed. 2. AC/ AHU line not supported in attic. PIPING SUPPORT TABLE: G2424.1 (415) 3. AC/AHU drain line not supported or insulated. CONDENSATE LINES INSULATION REQUIRED M307.2.5 4. Dryer vent not sealed at roof deck. DUCT PROPERLY SEALED..FBCM.603.1 5. Attic access not framed. 6. Appliances in attics. M1305.1, M 1305.1.3, 1305.1.3.1. Receptacle and light needed. Appliance needs to be removed for future. 7. Line diagram for subpanel needed. Verification of wire size requested. 08-3-2022 - NEED TO VERIFY WIRE SIZE AND LINE DIAGRAM FOR SUB PANEL. Check at insuation. Attic access not framed. 08-31-2022 1. Need to verify wire size and line diagram for sub panel. See above notes. 2. Sub panel not noted on drawings. 3. Attic access not ionstalled. 4. Front entry door not installed. Electrical panel cover is on and covered with plastic. 09-09-2022 Attic access not installed. 06-21-2023 1. Please provide landing, deck, and railing details to the building department for review and have approved drawings on site for inspection. Landings. Landing not proper height and railing not installed properly. 2. Energy calculations not on site. 3. Product Approval for SGD and windows nor on site. 4. Only one kitchen circuit. 5. Window stickers not on site. Inspection stopped.
BLD - BUILDING FINAL 05/10/2024 Disapproved - NO FEE LMILLER
Note: 5-10-24 energy calcs model numbers not matching (revision needed) FBC 107.3 need trim around attic access FBC. R807.1 6/21/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2490 THIS IS A REINSPECTION Inspector Notes from Inspection 2420 THIS IS A REINSPECTION 1. Windows and doors not installed. 2. AC/ AHU line not supported in attic. PIPING SUPPORT TABLE: G2424.1 (415) 3. AC/AHU drain line not supported or insulated. CONDENSATE LINES INSULATION REQUIRED M307.2.5 4. Dryer vent not sealed at roof deck. DUCT PROPERLY SEALED..FBCM.603.1 5. Attic access not framed. 6. Appliances in attics. M1305.1, M 1305.1.3, 1305.1.3.1. Receptacle and light needed. Appliance needs to be removed for future. 7. Line diagram for subpanel needed. Verification of wire size requested. 08-3-2022 - NEED TO VERIFY WIRE SIZE AND LINE DIAGRAM FOR SUB PANEL. Check at insuation. Attic access not framed. 08-31-2022 1. Need to verify wire size and line diagram for sub panel. See above notes. 2. Sub panel not noted on drawings. 3. Attic access not ionstalled. 4. Front entry door not installed. Electrical panel cover is on and covered with plastic. 09-09-2022 Attic access not installed. 06-21-2023 1. Please provide landing, deck, and railing details to the building department for review and have approved drawings on site for inspection. Landings. Landing not proper height and railing not installed properly. 2. Energy calculations not on site. 3. Product Approval for SGD and windows nor on site. 4. Only one kitchen circuit. 5. Window stickers not on site. Inspection stopped.
WINDOW NAILING 05/10/2024 APPROVED LMILLER
Note: 5-10-24 Entry door installed ENTRY DOOR.
ROW - FINAL INSPECTION 12/05/2023 APPROVED EMADISON
Note:
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/05/2023 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 12/05/2023 APPROVED EMADISON
ROW - FINAL INSPECTION 06/21/2023 Disapproved - NO FEE EMADISON
Note: ** 06/21/23 BUILDER NEEDS TO PROVIDE A FINAL SURVEY FOR SITE AS IT IS OVER 300 SQ FT. BEFORE THE FINAL ROW CAN BE APPROVED
U -UTILITY RESIDENTIAL FINAL 06/21/2023 FINAL APPROVED JHARDING
BLD - BUILDING FINAL 06/21/2023 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2490 THIS IS A REINSPECTION Inspector Notes from Inspection 2420 THIS IS A REINSPECTION 1. Windows and doors not installed. 2. AC/ AHU line not supported in attic. PIPING SUPPORT TABLE: G2424.1 (415) 3. AC/AHU drain line not supported or insulated. CONDENSATE LINES INSULATION REQUIRED M307.2.5 4. Dryer vent not sealed at roof deck. DUCT PROPERLY SEALED..FBCM.603.1 5. Attic access not framed. 6. Appliances in attics. M1305.1, M 1305.1.3, 1305.1.3.1. Receptacle and light needed. Appliance needs to be removed for future. 7. Line diagram for subpanel needed. Verification of wire size requested. 08-3-2022 - NEED TO VERIFY WIRE SIZE AND LINE DIAGRAM FOR SUB PANEL. Check at insuation. Attic access not framed. 08-31-2022 1. Need to verify wire size and line diagram for sub panel. See above notes. 2. Sub panel not noted on drawings. 3. Attic access not ionstalled. 4. Front entry door not installed. Electrical panel cover is on and covered with plastic. 09-09-2022 Attic access not installed. 06-21-2023 1. Please provide landing, deck, and railing details to the building department for review and have approved drawings on site for inspection. Landings. Landing not proper height and railing not installed properly. 2. Energy calculations not on site. Please have a clean set of approved drawings on site for inspection. 3. Product Approval for SGD and windows nor on site. 4. Only one kitchen circuit. NEC 210.52(B): Receptacle Outlets served 5. Window stickers not on site. 6. Attic light not working. M1305.1.3 1. M1305.1.3 Appliances in attics 7. AHU not accessible. No walkway for access to AHU. M1305.1.3 1. M1305.1.3 Appliances in attics Inspection stopped.
GRAVITY SEWER TEST 04/06/2023 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 PAN DRAIN LINE NEEDS TO BE 'CPVC' NOT PVC ALSO IT HAS TO BE SLEEVED 2''2X DIAMETER LARGER THAN PIPE PASSING THROUGH FOOTER, CONTRACTOR INFORMED ME THAT IT WAS CHANGING TO TANKLESS TYPE NEED REVISION TO SHOW AND LOAD CALCULAATION CHANGE BRASS C/O NEEDED IN DRIVEWAY
INSULATION 09/09/2022 APPROVED - AS NOTED AGAETANO
Note: THIS IS A REINSPECTION Inspector Notes from Inspection 2420 THIS IS A REINSPECTION 1. Windows and doors not installed. 2. AC/ AHU line not supported in attic. PIPING SUPPORT TABLE: G2424.1 (415) 3. AC/AHU drain line not supported or insulated. CONDENSATE LINES INSULATION REQUIRED M307.2.5 4. Dryer vent not sealed at roof deck. DUCT PROPERLY SEALED..FBCM.603.1 5. Attic access not framed. 6. Appliances in attics. M1305.1, M 1305.1.3, 1305.1.3.1. Receptacle and light needed. Appliance needs to be removed for future. 7. Line diagram for subpanel needed. Verification of wire size requested. 08-3-2022 - NEED TO VERIFY WIRE SIZE AND LINE DIAGRAM FOR SUB PANEL. Check at insuation. Attic access not framed. 08-31-2022 1. Need to verify wire size and line diagram for sub panel. See above notes. 2. Sub panel not noted on drawings. 3. Attic access not ionstalled. 4. Front entry door not installed. Electrical panel cover is on and covered with plastic. 09-09-2022 Attic access not installed.
INSULATION 08/31/2022 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2420 THIS IS A REINSPECTION 1. Windows and doors not installed. 2. AC/ AHU line not supported in attic. PIPING SUPPORT TABLE: G2424.1 (415) 3. AC/AHU drain line not supported or insulated. CONDENSATE LINES INSULATION REQUIRED M307.2.5 4. Dryer vent not sealed at roof deck. DUCT PROPERLY SEALED..FBCM.603.1 5. Attic access not framed. 6. Appliances in attics. M1305.1, M 1305.1.3, 1305.1.3.1. Receptacle and light needed. Appliance needs to be removed for future. 7. Line diagram for subpanel needed. Verification of wire size requested. 08-3-2022 - NEED TO VERIFY WIRE SIZE AND LINE DIAGRAM FOR SUB PANEL. Check at insuation. Attic access not framed. 08-31-2022 1. Need to verify wire size and line diagram for sub panel. See above notes. 2. Sub panel not noted on drawings. 3. Attic access not ionstalled. 4. Front entry door not installed. Electrical panel cover is on and covered with plastic.
ROOF VALLEY & METAL 08/03/2022 APPROVED AGAETANO
ALL ROUGH 08/03/2022 APPROVED - AS NOTED AGAETANO
Note: THIS IS A REINSPECTION 1. Windows and doors not installed. 2. AC/ AHU line not supported in attic. PIPING SUPPORT TABLE: G2424.1 (415) 3. AC/AHU drain line not supported or insulated. CONDENSATE LINES INSULATION REQUIRED M307.2.5 4. Dryer vent not sealed at roof deck. DUCT PROPERLY SEALED..FBCM.603.1 5. Attic access not framed. 6. Appliances in attics. M1305.1, M 1305.1.3, 1305.1.3.1. Receptacle and light needed. Appliance needs to be removed for future. 7. Line diagram for subpanel needed. Verification of wire size requested. 08-3-2022 - NEED TO VERIFY WIRE SIZE AND LINE DIAGRAM FOR SUB PANEL. Check at insuation. Attic access not framed.
ALL ROUGH 07/12/2022 Disapproved - NO FEE AGAETANO
Note: 1. Windows and doors not installed. 2. AC/ AHU line not supported in attic. PIPING SUPPORT TABLE: G2424.1 (415) 3. AC/AHU drain line not supported or insulated. CONDENSATE LINES INSULATION REQUIRED M307.2.5 4. Dryer vent not sealed at roof deck. DUCT PROPERLY SEALED..FBCM.603.1 5. Attic access not framed. 6. Appliances in attics. M1305.1, M 1305.1.3, 1305.1.3.1. Receptacle and light needed. Appliance needs to be removed for future. 7. Line diagram for subpanel needed. Verification of wire size requested.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/06/2022 APPROVED AGAETANO
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Please submit a full set of approved drawings including roof framing, tie downs, and braces. 6-8-22 plans per notes above were not on site. Need approved revision on site for inspection.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/08/2022 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION Please submit a full set of approved drawings including roof framing, tie downs, and braces. 6-8-22 plans per notes above were not on site. Need approved revision on site for inspection.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/23/2022 Disapproved - NO FEE AGAETANO
Note: Please submit a full set of approved drawings including roof framing, tie downs, and braces.
TIE BEAM / LINTEL 04/28/2022 APPROVED AGAETANO
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Please have approved drawings on site for inspection. Lintel schedule details missing. 04-19-2022 1. Back left SGD is missing down cell. Noted on drawings. 2. Back left SGD opening is 6' and 5' opening submitted on drawings. Please submit a revision to the building department for 6' opening. Energy calculations will also need to be adjusted if 6' opening is installed.
TIE BEAM / LINTEL 04/19/2022 Disapproved -FEE REQUIRED AGAETANO
Note: THIS IS A REINSPECTION Please have approved drawings on site for inspection. Lintel schedule details missing. 04-19-2022 1. Back left SGD is missing down cell. Noted on drawings. 2. Back left SGD opening is 6' and 5' opening submitted on drawings. Please submit a revision to the building department for 6' opening. Energy calculations will also need to be adjusted if 6' opening is installed. Inspection stopped.
TIE BEAM / LINTEL 03/29/2022 Disapproved - NO FEE AGAETANO
Note: Please have approved drawings on site for inspection. Lintel schedule details missing.
MONOLITHIC SLAB 02/15/2022 APPROVED AGAETANO
PLUMBING 1ST ROUGH UNDERGROUND 02/08/2022 APPROVED - AS NOTED MGIBSON
Note: PAN DRAIN LINE NEEDS TO BE 'CPVC' NOT PVC ALSO IT HAS TO BE SLEEVED 2''2X DIAMETER LARGER THAN PIPE PASSING THROUGH FOOTER, CONTRACTOR INFORMED ME THAT IT WAS CHANGING TO TANKLESS TYPE NEED REVISION TO SHOW AND LOAD CALCULAATION CHANGE
BLD - BUILDING FINAL
Note: 10/4/2024 - PREVIOUS INSPECTION NOTES 1. Need to submitt Energy Calcs to City building department. 2. Facia covering is missing and coming apart in several areas. 3. outlet in kitchen is not GFCI Protected 4. Missing notice to onwer A/C in attic. 5. Missing termite sticker. 6. Revise plans to show new location of A/C, attic access, and new kitchen layout. 7. Spoke with contractor 8. Resident living in the addition. 5/10/2024 - PREVIOUS INSPECTION NOTES 5-10-24 energy calcs model numbers not matching (revision needed) FBC 107.3 need trim around attic access FBC. R807.1 6/21/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2490 THIS IS A REINSPECTION Inspector Notes from Inspection 2420 THIS IS A REINSPECTION 1. Windows and doors not installed. 2. AC/ AHU line not supported in attic. PIPING SUPPORT TABLE: G2424.1 (415) 3. AC/AHU drain line not supported or insulated. CONDENSATE LINES INSULATION REQUIRED M307.2.5 4. Dryer vent not sealed at roof deck. DUCT PROPERLY SEALED..FBCM.603.1 5. Attic access not framed. 6. Appliances in attics. M1305.1, M 1305.1.3, 1305.1.3.1. Receptacle and light needed. Appliance needs to be removed for future. 7. Line diagram for subpanel needed. Verification of wire size requested. 08-3-2022 - NEED TO VERIFY WIRE SIZE AND LINE DIAGRAM FOR SUB PANEL. Check at insuation. Attic access not framed. 08-31-2022 1. Need to verify wire size and line diagram for sub panel. See above notes. 2. Sub panel not noted on drawings. 3. Attic access not ionstalled. 4. Front entry door not installed. Electrical panel cover is on and covered with plastic. 09-09-2022 Attic access not installed. 06-21-2023 1. Please provide landing, deck, and railing details to the building department for review and have approved drawings on site for inspection. Landings. Landing not proper height and railing not installed properly. 2. Energy calculations not on site. 3. Product Approval for SGD and windows nor on site. 4. Only one kitchen circuit. 5. Window stickers not on site. Inspection stopped.

Review History

Department Status Date In Date Out
BLD COMPLETE 11/05/2024 11/12/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 10/15/2024 10/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 05/08/2024 05/08/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The NOC submitted is expired (3/31/24)
BADMIN INFORMATION 12/04/2023 12/04/2023
Note: Marked INFORMATION By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM Doc name and file name must match - ex - site plan =site plan
ELEC COMPLETE 09/01/2022 09/02/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 05/31/2022 06/01/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 04/22/2022 04/25/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 04/12/2022 04/13/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/11/2022 03/11/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/11/2022 03/11/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/27/2022 01/27/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 01/27/2022 02/02/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 01/27/2022 01/27/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 01/06/2022 01/06/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON HOLD 01/05/2022 01/05/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM AC pad that is shown on plans are not shown on site plan. Please show ac location on site plan. It must meet a 5ft setback so it does not encroach in the 5ft utility easement. Please show the width of breezeway on site plan for review
ZON HOLD 01/05/2022 01/05/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Ac pad location on plan doesn't match new site plan submitted Plans show that breezway width is 5ft. Site plan doesn't match. Both must match
MECH COMPLETE 12/30/2021 12/30/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ELEC COMPLETE 12/30/2021 12/30/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 12/30/2021 12/30/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON HOLD 12/30/2021 12/30/2021
Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Provide roof slope of breezeway
MECH HOLD 12/03/2021 12/03/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Provide Duct layout signed by the AC contractor
ELEC HOLD 12/03/2021 12/06/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Outlets in bar area, bathroom, and outside need to be GFCI protected. NEC 2017 210.8 2nd REQUEST
BLD HOLD 12/03/2021 12/06/2021
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comment item1: 1. Provide an updated City of Palm Coast Roofing Worksheet. Note: Roofing Worksheet is the same as previously submitted. Please use Asphalt Shingles Roof Covering Type.
ZON HOLD 12/03/2021 12/07/2021
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide new elevation plans showing the breezway that was added. Please make note that all roof and exterior will match existing house.
BLD HOLD 11/08/2021 11/12/2021
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential PLAN REVIEW COMMENTS: 1. Provide an updated City of Palm Coast Roofing Worksheet. 2. Note on drawings call-out Grade #2 species. Provide species of lumber to be used.
ELEC HOLD 11/08/2021 11/08/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Outlets in bar area, bathroom, and outside need to be GFCI protected. NEC 2017 210.8
MECH HOLD 11/08/2021 11/08/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy calculations
PLUM COMPLETE 11/08/2021 11/12/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
SW1 COMPLETE 11/08/2021 11/15/2021
Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM
ZON HOLD 11/08/2021 11/12/2021
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Accessory structures other than fences, walls, arbors, trellises, pergolas, and detached garages shall be located behind the front and side street building facades of the principal structure. This would not be an addition if it is not attached to the primary structure. Site plan must show all setbacks from structure to property lines. Accessory building exterior must match the house.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EXTENSION ¤40.00 02/10/2025
PLAN REVIEW - REVISION ¤32.50 10/21/2024
PLAN REVIEW - REVISION ¤32.50 04/24/2024
PLAN REVIEW - REVISION ¤32.50 04/24/2024
PLAN REVIEW - REVISION ¤32.50 04/24/2024
REINSPECTION RESIDENTIAL ¤40.00 04/24/2024
REINSPECTION RESIDENTIAL ¤40.00 04/24/2024
EXTENSION ¤40.00 04/24/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/26/2022
INSPECTION - RESIDENTIAL ¤60.00 01/26/2022
PLAN REVIEW - RESIDENTIAL ¤65.00 01/26/2022
SURCHARGE FS 533.721 ¤2.00 01/26/2022
SURCHARGE - FS 468.631 ¤2.85 01/26/2022
SW ENG - INSPECTION 20 ¤20.00 01/26/2022
SW ENG - REVIEW 20 ¤20.00 01/26/2022
SITE PLAN 30 ¤30.00 01/26/2022
Fees Total Due: ¤0.00 Total Paid: ¤519.85