I want to search for...
Permit #2021111006
Permit Details
Status: COED
| Parcel Id: 07-11-31-7059-00620-0090 |
| CONDITIONED SPACE: 2216 sqft |
| GARAGE: 619 sqft |
| OPENED PORCH (WITH ROOF) : 140 sqft |
| OPENED PORCH (WITH ROOF) : 29 sqft |
| Total Square Footage: 3004 sqft |
| Block: 00620 |
| Subdivision: 2211 - SECTION 59-SEMINOLE PARK |
| Job Phone: 321-271-9033 |
| Location Address: 3 SLATOR CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/31/2022 |
| NOC: RECORDED |
| Applicant name: KEITH E TANNER |
| Owner: VINTAGE ESTATE HOMES, LLC |
|
Address 4885 N. WICKHAM RD MELBOURNE, FL 32940 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MERCEDES PREMIER HOMES, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
4885 N WICKHAM RD MELBOURNE, FL 32940 |
STE 101 MELBOURNE, FL 32940 |
CGC1516602 (Exp: 08/31/2024) | 321-610-3924 |
Sub Contractors
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
YOLANDA PIZARRO
| Status | Location Address | State License Number | Phone |
| INACTIVE |
5401 ENERGY AIR CT , 0 |
CAC1819724 (Exp: 08/31/2024) | 407-886-3729 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - STORMWATER FINAL | 12/14/2022 | APPROVED | GBERTOLA |
| Note: 12/14/22=AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD _______________________________________________________________________________________________________________________ 12/13/2022 - PREVIOUS INSPECTION NOTES AT THE TIME OF THIS INSPECTION NOTHING HAS BEEN FIXED 9:34AM IF YOU NEED A PM INSPECTION YOU NEED TO CALL US THE DAY OF THE INSPECTION TO SEE IF IT IS POSSIBLE WE DONT SEE THE NOTES IN THE APPLICANT NOTES INTILL THE TIME OF THE INSPECTION THANKS --------------------------------------------------------------------------------------- 12/12/2022 - PREVIOUS INSPECTION NOTES THINGS NEED TO BE DONE BEFORE PASSING 1) NEED TO BRING SWALE ON THE RIGHT SIDE OF DRIVEWAY UP TO MATCH THE GRADE TO THE LOT TO THE RIGHT OF YOUR OR TAKE THE HUMP OUT AT THE PROPERTY LINE. 2) NEED TO PICK UP ALL TRASH UP IN THE VACANT TO THE LEFT OF YOURS. 3) NEED TO HAVE SOD IN THE BACK WHERE ALL BARE AREAS ARE NO SEED AND STRAW DO TO THE STEP SLOP. 4) NEED TO HAVE SOD WHERE THE DUMPSTER AND PORTER JOHN WAS. 5) NEED TO ALL OVER POURED CONCRETE OUT OF CULVERT PIPE. -------------------------------------------------------------------------------------------------------------------- NEED TO BRING SWALE ON THE RIGHT SIDE OF DRIVEWAY SO YOU CAN MATCH THE SWALE GRADE TO THE LOT TO THE RIGHT OF YOURS | |||
| ROW - STORMWATER FINAL | 12/13/2022 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: AT THE TIME OF THIS INSPECTION NOTHING HAS BEEN FIXED 9:34AM IF YOU NEED A PM INSPECTION YOU NEED TO CALL US THE DAY OF THE INSPECTION TO SEE IF IT IS POSSIBLE WE DONT SEE THE NOTES IN THE APPLICANT NOTES INTILL THE TIME OF THE INSPECTION THANKS --------------------------------------------------------------------------------------- 12/12/2022 - PREVIOUS INSPECTION NOTES THINGS NEED TO BE DONE BEFORE PASSING 1) NEED TO BRING SWALE ON THE RIGHT SIDE OF DRIVEWAY UP TO MATCH THE GRADE TO THE LOT TO THE RIGHT OF YOUR OR TAKE THE HUMP OUT AT THE PROPERTY LINE. 2) NEED TO PICK UP ALL TRASH UP IN THE VACANT TO THE LEFT OF YOURS. 3) NEED TO HAVE SOD IN THE BACK WHERE ALL BARE AREAS ARE NO SEED AND STRAW DO TO THE STEP SLOP. 4) NEED TO HAVE SOD WHERE THE DUMPSTER AND PORTER JOHN WAS. 5) NEED TO ALL OVER POURED CONCRETE OUT OF CULVERT PIPE. -------------------------------------------------------------------------------------------------------------------- NEED TO BRING SWALE ON THE RIGHT SIDE OF DRIVEWAY SO YOU CAN MATCH THE SWALE GRADE TO THE LOT TO THE RIGHT OF YOURS | |||
| ROW - STORMWATER FINAL | 12/12/2022 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: THINGS NEED TO BE DONE BEFORE PASSING 1) NEED TO BRING SWALE ON THE RIGHT SIDE OF DRIVEWAY UP TO MATCH THE GRADE TO THE LOT TO THE RIGHT OF YOUR OR TAKE THE HUMP OUT AT THE PROPERTY LINE. 2) NEED TO PICK UP ALL TRASH UP IN THE VACANT TO THE LEFT OF YOURS. 3) NEED TO HAVE SOD IN THE BACK WHERE ALL BARE AREAS ARE NO SEED AND STRAW DO TO THE STEP SLOP. 4) NEED TO HAVE SOD WHERE THE DUMPSTER AND PORTER JOHN WAS. 5) NEED TO ALL OVER POURED CONCRETE OUT OF CULVERT PIPE. -------------------------------------------------------------------------------------------------------------------- NEED TO BRING SWALE ON THE RIGHT SIDE OF DRIVEWAY SO YOU CAN MATCH THE SWALE GRADE TO THE LOT TO THE RIGHT OF YOURS | |||
| U -UTILITY RESIDENTIAL FINAL | 12/12/2022 | FINAL APPROVED | JHARDING |
| BLD - BUILDING FINAL | 12/12/2022 | CANCELLED BY APPLICANT | WEB |
| BLD - BUILDING FINAL | 12/12/2022 | FINAL APPROVED | BTAYLOR |
| ROW - FINAL APRON (AFTER POUR) | 12/12/2022 | APPROVED | PFLANAGAN |
| Note: Inspector Notes from Inspection 9465 NEED TO BRING SWALE ON THE RIGHT SIDE OF DRIVEWAY SO YOU CAN MATCH THE SWALE GRADE TO THE LOT TO THE RIGHT OF YOURS | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/09/2022 | APPROVED | PFLANAGAN |
| Note: 12/6/2022 - PREVIOUS INSPECTION NOTES ALL SOD ELEVATIONS NEED TO BE A MINIMUM OF 4" BELOW THE FFE ON A CONCRETE BLOCK HOUSE AND 4" FOR WOOD FRAME HOUSE. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/09/2022 | APPROVED - AS NOTED | PFLANAGAN |
| Note: NEED TO BRING SWALE ON THE RIGHT SIDE OF DRIVEWAY SO YOU CAN MATCH THE SWALE GRADE TO THE LOT TO THE RIGHT OF YOURS | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/06/2022 | Disapproved - NO FEE | PFLANAGAN |
| Note: ALL SOD ELEVATIONS NEED TO BE A MINIMUM OF 4" BELOW THE FFE ON A CONCRETE BLOCK HOUSE AND 4" FOR WOOD FRAME HOUSE. | |||
| U-CROSS CONNECTION | 11/30/2022 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irrigation-no cross connection | |||
| ELECTRIC - EARLY POWER | 11/30/2022 | APPROVED | BTAYLOR |
| Note: 11/28/2022 - PREVIOUS INSPECTION NOTES 11/23/2022 - PREVIOUS INSPECTION NOTES 11-23-22 House locked. 11-28-22 1. Microwave not safed off. | |||
| ELECTRIC - EARLY POWER | 11/28/2022 | Disapproved - NO FEE | BTAYLOR |
| Note: 11/23/2022 - PREVIOUS INSPECTION NOTES 11-23-22 House locked. 11-28-22 1. Microwave not safed off. | |||
| ELECTRIC - EARLY POWER | 11/23/2022 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: 11-23-22 House locked. | |||
| ROW- PRE-APRON (PRE-POUR) | 11/17/2022 | APPROVED - AS NOTED | RGROSS |
| Note: Site meet with super to discuss good compaction when using larger rock under the pipe. 11/16/2022 - PREVIOUS INSPECTION NOTES AT THE TIME OF THIS INSPECTION THING NEED TO CORRECTED 1) THERE ARE AREAS IN POURING AREA THAT WON'T GIVE YOU THE MINIMUM AMOUNT OF CONCRETE THERE NEEDS TO BE 4" OF CONCRETE ABOVE THE RIGHT OF WAY AND 6" IN THE RIGHT OF WAY 2) NEED TO HAVE 95% COMPACTION IN THE ENTIRE POURING AREA --------------------------------------------------------------------------------------------- 11/15/2022 - PREVIOUS INSPECTION NOTES AT THE TIME OF THIS INSPECTION THE CULVERT IS GOOD THINGS THAT NEED CORRECTED BEFORE PASSING 1) THERE ARE AREAS IN POURING AREA THAT WON'T GIVE YOU THE MINIMUM AMOUNT OF CONCRETE THERE NEEDS TO BE 4" OF CONCRETE ABOVE THE RIGHT OF WAY AND 6" IN THE RIGHT OF WAY 2) NEED TO HAVE 95% COMPACTION IN THE ENTIRE POURING AREA | |||
| ROW- PRE-APRON (PRE-POUR) | 11/16/2022 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: AT THE TIME OF THIS INSPECTION THING NEED TO CORRECTED 1) THERE ARE AREAS IN POURING AREA THAT WON'T GIVE YOU THE MINIMUM AMOUNT OF CONCRETE THERE NEEDS TO BE 4" OF CONCRETE ABOVE THE RIGHT OF WAY AND 6" IN THE RIGHT OF WAY 2) NEED TO HAVE 95% COMPACTION IN THE ENTIRE POURING AREA --------------------------------------------------------------------------------------------- 11/15/2022 - PREVIOUS INSPECTION NOTES AT THE TIME OF THIS INSPECTION THE CULVERT IS GOOD THINGS THAT NEED CORRECTED BEFORE PASSING 1) THERE ARE AREAS IN POURING AREA THAT WON'T GIVE YOU THE MINIMUM AMOUNT OF CONCRETE THERE NEEDS TO BE 4" OF CONCRETE ABOVE THE RIGHT OF WAY AND 6" IN THE RIGHT OF WAY 2) NEED TO HAVE 95% COMPACTION IN THE ENTIRE POURING AREA | |||
| ROW- PRE-APRON (PRE-POUR) | 11/15/2022 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: AT THE TIME OF THIS INSPECTION THE CULVERT IS GOOD THINGS THAT NEED CORRECTED BEFORE PASSING 1) THERE ARE AREAS IN POURING AREA THAT WON'T GIVE YOU THE MINIMUM AMOUNT OF CONCRETE THERE NEEDS TO BE 4" OF CONCRETE ABOVE THE RIGHT OF WAY AND 6" IN THE RIGHT OF WAY 2) NEED TO HAVE 95% COMPACTION IN THE ENTIRE POURING AREA | |||
| ROW- PRE-APRON (PRE-POUR) | 11/09/2022 | CANCELLED BY APPLICANT | PFLANAGAN |
| U - SEWER TIE IN | 11/01/2022 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 10/11/2022 | APPROVED | CSTONE |
| INSULATION | 09/19/2022 | APPROVED | BTAYLOR |
| Note: 9/16/2022 - PREVIOUS INSPECTION NOTES 9/15/2022 - PREVIOUS INSPECTION NOTES 9/14/2022 - PREVIOUS INSPECTION NOTES THIS IS A REINSPECTION 9-14-22 1. Not ready. 2. Wires need fire foam. 9-15-22 1. Wires in house need fire foam. 2. Random holes in house need fire foam. Circled on electrical plan. 9-16-22 1. Wires in house need fire foam. CIRCLED ON ELECTRICAL PLAN!!!! | |||
| INSULATION | 09/16/2022 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: 9/15/2022 - PREVIOUS INSPECTION NOTES 9/14/2022 - PREVIOUS INSPECTION NOTES THIS IS A REINSPECTION 9-14-22 1. Not ready. 2. Wires need fire foam. 9-15-22 1. Wires in house need fire foam. 2. Random holes in house need fire foam. Circled on electrical plan. 9-16-22 1. Wires in house need fire foam. CIRCLED ON ELECTRICAL PLAN!!!! | |||
| INSULATION | 09/15/2022 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: 9/14/2022 - PREVIOUS INSPECTION NOTES THIS IS A REINSPECTION 9-14-22 1. Not ready. 2. Wires need fire foam. 9-15-22 1. Wires in house need fire foam. 2. Random holes in house need fire foam. Circled on electrical plan. | |||
| INSULATION | 09/14/2022 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: THIS IS A REINSPECTION 9-14-22 1. Not ready. 2. Wires need fire foam. | |||
| INSULATION | 09/09/2022 | CANCELLED BY APPLICANT | BTAYLOR |
| LATH/BRICK/ WATER BARRIER | 08/23/2022 | APPROVED | BTAYLOR |
| Note: Inspector Notes from Inspection 2420 8-18-22 1. Need nail plate in garage for piping. 2. Need to seal all seams on dryer duct. | |||
| ALL ROUGH | 08/18/2022 | APPROVED - AS NOTED | BTAYLOR |
| Note: 8-18-22 1. Need nail plate in garage for piping. 2. Need to seal all seams on dryer duct. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/21/2022 | APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Valley areas missing strapping and 2x4 valley run per plans on General notes page. Circled on plans | |||
| ROOF VALLEY & METAL | 06/09/2022 | APPROVED | TSTAUFFACHER |
| WALL SHEATHING | 06/09/2022 | APPROVED | TSTAUFFACHER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/09/2022 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Valley areas missing strapping and 2x4 valley run per plans on General notes page. Circled on plans | |||
| TIE BEAM / LINTEL | 05/05/2022 | APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Cancelled 05/03/2022 | |||
| FOUND SURVEY APPROVED (OFFICE) | 05/05/2022 | APPROVED | TDOAK |
| TIE BEAM / LINTEL | 05/03/2022 | CANCELLED BY APPLICANT | TSTAUFFACHER |
| Note: Cancelled 05/03/2022 | |||
| MONOLITHIC SLAB | 04/20/2022 | APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB | 04/19/2022 | CANCELLED BY APPLICANT | TSTAUFFACHER |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/11/2022 | APPROVED | TSTAUFFACHER |
| GRAVITY SEWER TEST | 04/11/2022 | APPROVED | TSTAUFFACHER |
| WATER METER INSTALLATION REQUEST | 03/17/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 07/14/2022 | 07/15/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/05/2022 | 05/05/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/05/2022 | 05/05/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/06/2022 | 01/06/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/06/2022 | 01/10/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/22/2021 | 11/22/2021 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 11/22/2021 | 11/29/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 11/22/2021 | 11/22/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/22/2021 | 11/22/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 11/22/2021 | 11/29/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 11/22/2021 | 11/23/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Indoor design temp on heatload must be a minimum of 75 degrees per R302.1 FBC Energy Conservation 2020 7Th edition | |||
| SW1 | COMPLETE | 11/22/2021 | 11/30/2021 |
| Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/22/2021 | 11/22/2021 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Horizontal banding must wrap corners at least two feet | |||
| SWALE | COMPLETE | 11/22/2021 | 01/25/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 12/14/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/14/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/14/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/14/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/14/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 12/14/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 12/14/2022 |
| SW ENG REINSPECTION 20 | ¤20.00 | 12/14/2022 |
| SW ENG REINSPECTION 20 | ¤20.00 | 12/14/2022 |
| SW ENG REINSPECTION 30 | ¤30.00 | 12/14/2022 |
| SW ENG REINSPECTION 30 | ¤30.00 | 12/14/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/31/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 01/31/2022 |
| TRANSPORTATION IMPACT FEE | ¤1,718.00 | 01/31/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 01/31/2022 |
| SEWER INSPECTION | ¤25.00 | 01/31/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 01/31/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 01/31/2022 |
| SITE PLAN 30 | ¤30.00 | 01/31/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 01/31/2022 |
| IMPACT FEE FIRE | ¤388.65 | 01/31/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 01/31/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 01/31/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 01/31/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 01/31/2022 |
| SURCHARGE FS 533.721 | ¤10.68 | 01/31/2022 |
| SURCHARGE - FS 468.631 | ¤16.02 | 01/31/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 01/31/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 01/31/2022 |
| SW ENG PRE APRON | ¤30.00 | 01/31/2022 |
| CONNECTION FEES | ¤1,077.88 | 01/31/2022 |
| METER - DEPOSIT | ¤60.00 | 01/31/2022 |
| WATER- TURN ON | ¤25.00 | 01/31/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/31/2022 |
| INSPECTION - RESIDENTIAL | ¤764.50 | 01/31/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤216.84 | 01/31/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤18,624.61 |