I want to search for...
Permit #2021120009
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7004-00270-0020 |
| SCREEN PORCH (SOLID ROOF) : 480 sqft |
| PATIO/DECK (NO ROOF) : 360 sqft |
| Total Square Footage: 840 sqft |
| Block: 00270 |
| Subdivision: 2203 - SECTION 4-COUNTRY CLUB COVE |
| Job Phone: 386-338-1859 |
| Location Address: 5 CONWAY CT |
| Type: BA - BUILDING ADDITION |
| Issue Date: 01/28/2022 |
| NOC: RECORDED |
| Applicant name: SOPHAN KES |
| Owner: SPRINGMYER TROY R & KIMBERLEY A H&W |
|
Address 5 CONWAY COURT PALM COAST, FL 32137 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤60,000.00 |
| Job Description: Add covered porch and deck |
| Type: CN |
Contractor
KES CONSTRUCTION, INC
| Status | Location Address | State License Number |
| ACTIVE |
42 OAKLEAF WAY PALM COAST, FL 32137 |
CBC1264797 (Exp: 08/31/2026) |
Sub Contractors
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
60 COOPER LANE PALM COAST, FL 32137 |
EC13008029 (Exp: 08/31/2028) | 386-225-1937 |
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 02/16/2023 | FINAL APPROVED | TSTAUFFACHER |
| Note: 1/19/2023 - PREVIOUS INSPECTION NOTES 1/4/2023 - PREVIOUS INSPECTION NOTES 1/3/2023 - PREVIOUS INSPECTION NOTES 12/29/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2425 Rear french doors to new addition 12-29-2022 No inspection, doors locked, need access for inspection. FBC R110.1 01-03-2023 FALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGHWINDOW / DOORS, FBC R 609.3. Check all guards. 01-04-2023 ALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGHWINDOW / DOORS, FBC R 609.3. Check all guards. Homeowner was very rude and aggressive towards inspector. Building official spoke to homeowner. 01-19-2023 LL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGHWINDOW / DOORS, FBC R 609.3. Check all guards. Building official on site as well as superintendent. | |||
| BLD - BUILDING FINAL | 01/19/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 1/4/2023 - PREVIOUS INSPECTION NOTES 1/3/2023 - PREVIOUS INSPECTION NOTES 12/29/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2425 Rear french doors to new addition 12-29-2022 No inspection, doors locked, need access for inspection. FBC R110.1 01-03-2023 FALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGHWINDOW / DOORS, FBC R 609.3. Check all guards. 01-04-2023 ALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGHWINDOW / DOORS, FBC R 609.3. Check all guards. Homeowner was very rude and aggressive towards inspector. Building official spoke to homeowner. 01-19-2023 LL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGHWINDOW / DOORS, FBC R 609.3. Check all guards. Building official on site as well as superintendent. | |||
| BLD - BUILDING FINAL | 01/04/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 1/3/2023 - PREVIOUS INSPECTION NOTES 12/29/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2425 Rear french doors to new addition 12-29-2022 No inspection, doors locked, need access for inspection. FBC R110.1 01-03-2023 FALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGHWINDOW / DOORS, FBC R 609.3. Check all guards. 01-04-2023 ALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGHWINDOW / DOORS, FBC R 609.3. Check all guards. Homeowner was very rude and aggressive towards inspector. Building official spoke to homeowner. | |||
| BLD - BUILDING FINAL | 01/03/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 12/29/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2425 Rear french doors to new addition 12-29-2022 No inspection, doors locked, need access for inspection. FBC R110.1 01-03-2023 FALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGHWINDOW / DOORS, FBC R 609.3. Check all guards. | |||
| ROW - FINAL INSPECTION | 01/03/2023 | APPROVED | GBERTOLA |
| Note: 01/3/23=AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD __________________________________________________________________________________________________________________ 12/29/2022 - PREVIOUS INSPECTION NOTES 12/29/22= ON THE RIGHT SIDE * ALL THE Bare earth area along ON THE RIGHT SIDE NEED TO BE SODDED TO PREVENT WASHOUTS | |||
| U -UTILITY RESIDENTIAL FINAL | 12/29/2022 | FINAL APPROVED | DHANEY |
| ROW - FINAL INSPECTION | 12/29/2022 | Disapproved - NO FEE | GBERTOLA |
| Note: 12/29/22= ON THE RIGHT SIDE * ALL THE Bare earth area along ON THE RIGHT SIDE NEED TO BE SODDED TO PREVENT WASHOUTS | |||
| BLD - BUILDING FINAL | 12/29/2022 | Disapproved - NO FEE | AGAETANO |
| Note: Inspector Notes from Inspection 2425 Rear french doors to new addition 12-29-2022 No inspection, doors locked, need access for inspection. FBC R110.1 | |||
| WINDOW NAILING | 10/04/2022 | APPROVED - AS NOTED | DCUSHING |
| Note: Rear french doors to new addition | |||
| ALL ROUGH | 09/15/2022 | APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION 08-25-2022 1. Please provide a revision to the building department for the recess lights to be installed. 2. All grounds need to be connected – NEC 110.14A 3. NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1 | |||
| FRAMING | 09/15/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Contractor not complete with exterior steps and landing. 08-25-2022 1. Landing and steps are not complete. BC40 used not as imbedded 4 x 4 as noted on drawings. 2. NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Please provide a large readable drawing for inspection. 09-15-2022 - Trex decking and railing will be completed by final. | |||
| FRAMING | 08/25/2022 | Disapproved - NO FEE | AGAETANO |
| Note: THIS IS A REINSPECTION Contractor not complete with exterior steps and landing. 08-25-2022 1. Landing and steps are not complete. BC40 used not as imbedded 4 x 4 as noted on drawings. 2. NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Please provide a large readable drawing for inspection. | |||
| ALL ROUGH | 08/25/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 08-25-2022 1. Please provide a revision to the building department for the recess lights to be installed. 2. All grounds need to be connected – NEC 110.14A 3. NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1 | |||
| FRAMING | 08/24/2022 | Disapproved - NO FEE | AGAETANO |
| Note: Contractor not complete with exterior steps and landing. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/24/2022 | APPROVED | AGAETANO |
| Note: New inspection due to canceled inspection THIS IS A REINSPECTION THIS IS A REINSPECTION 4/6/22 Stair way has not been constructed. The 36" high gaurdrails have not been contructed. 2/f Details. The hanger installed where the 2 x 12 beams meet the existing building are HUC410s not 412 as detailed. Several 2x6 rafters have been scabbed together and are not full lenght Install full lenght or submitt engineer worksheet detailing the as built. The hips have been scabbed spliced together. Povide details. The ceiling faming beams and connectors used need to be detailed. The (2) 2x12 ceiling beams that land above the rear slider not detailed. A detail showing the beams at this location and connectors needs to be detailed. LLSJ26 hangers are detailed to be used rafters to Hip beam. H 2.5 have been installed have submitt engineer detial or install correct hanges. Please have engineer submitt a revision to the building depart for the as built construction. Show any and all changes in connectors and constuction. Have approved revised drawings on site for reinspection. | |||
| ROOF VALLEY & METAL | 04/25/2022 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/08/2022 | CANCELLED BY APPLICANT | WEB |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 4/6/22 Stair way has not been constructed. The 36" high gaurdrails have not been contructed. 2/f Details. The hanger installed where the 2 x 12 beams meet the existing building are HUC410s not 412 as detailed. Several 2x6 rafters have been scabbed together and are not full lenght Install full lenght or submitt engineer worksheet detailing the as built. The hips have been scabbed spliced together. Povide details. The ceiling faming beams and connectors used need to be detailed. The (2) 2x12 ceiling beams that land above the rear slider not detailed. A detail showing the beams at this location and connectors needs to be detailed. LLSJ26 hangers are detailed to be used rafters to Hip beam. H 2.5 have been installed have submitt engineer detial or install correct hanges. Please have engineer submitt a revision to the building depart for the as built construction. Show any and all changes in connectors and constuction. Have approved revised drawings on site for reinspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/06/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: THIS IS A REINSPECTION 4/6/22 Stair way has not been constructed. The 36" high gaurdrails have not been contructed. 2/f Details. The hanger installed where the 2 x 12 beams meet the existing building are HUC410s not 412 as detailed. Several 2x6 rafters have been scabbed together and are not full lenght Install full lenght or submitt engineer worksheet detailing the as built. The hips have been scabbed spliced together. Povide details. The ceiling faming beams and connectors used need to be detailed. The (2) 2x12 ceiling beams that land above the rear slider not detailed. A detail showing the beams at this location and connectors needs to be detailed. LLSJ26 hangers are detailed to be used rafters to Hip beam. H 2.5 have been installed have submitt engineer detial or install correct hanges. Please have engineer submitt a revision to the building depart for the as built construction. Show any and all changes in connectors and constuction. Have approved revised drawings on site for reinspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/21/2022 | CANCELLED BY APPLICANT | AGAETANO |
| TIE BEAM / LINTEL | 03/21/2022 | APPROVED | AGAETANO |
| MONOLITHIC SLAB | 03/03/2022 | APPROVED | AGAETANO |
| STEM WALL FOUNDATION | 02/18/2022 | APPROVED | AGAETANO |
| FOOTER | 02/11/2022 | APPROVED | AGAETANO |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 09/14/2022 | 09/14/2022 |
| Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM LICENSE SUBMITTED EXPIRED FOR CBC, NOT CRC | |||
| BADMIN | INFORMATION | 09/14/2022 | 09/14/2022 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM That license is updated, however it is not the license this permit was issued to. | |||
| BLD | COMPLETE | 09/07/2022 | 09/09/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/18/2022 | 07/19/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 07/18/2022 | 07/18/2022 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM for future submittals, please name your files (plans) according to their given page name. If the design professional does not use industry standards, then you will need to enter the description of the plan page as the file name for quick identification. PLANS does not identify the type (structural, architectural, mechanical, electrical). | |||
| BLD | HOLD | 07/06/2022 | 07/07/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Residential REVIEW COMMENTS: 1. Revision notes FBC 61G15-18.011 & 61G-29.001. These are not Florida building Code references. The references are Florida State Statues. 2. Building Inspectors notes HUC410 was installed, not HUC412 as per the drawing. Per Simpson Strong Tie, HUC410 is to be installed on a 2 x 10. 3. Several 2x6 rafters have been scabbed together and are not full length Install full length or submit engineer worksheet detailing the as built. 4. Hips have been scabbed spliced together. Provide details. 5. The (2) 2x12 ceiling beams that land above the rear slider not detailed. A detail showing the beams at this location and connectors needs to be detailed. 6. LLSJ26 hangers are detailed to be used rafters to Hip beam. H 2.5 have been installed have submit engineer detail or install correct hangers. 7. Provide detail for knee wall and connection of knee wall and beam. Note: Various comments above are from the Boiling Inspectors report. | |||
| BLD | HOLD | 06/24/2022 | 06/24/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Revise Plans to show changes made. Plans submitted are lastly dated June 15, 2022. | |||
| BLD | HOLD | 06/16/2022 | 06/16/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. 2 x 6 proposed rafters are over spanned. FBC [A]107. Changing the revision date does not change the previous comments. 2. Engineer added a not concluding his opinion the structure meets the requirements of the Florida Building Code. If he engineer is certifying the construction, then the engineer is to certify the construction method per FAC 6915-G-18.011 and 69G15-29.001. | |||
| BLD | HOLD | 06/16/2022 | 06/16/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. 2 x 6 proposed rafters are over spanned. FBC [A]107. Changing the revision date does not change the previous comments. 2. Engineer added a not concluding his opinion the structure meets the requirements of the Florida Building Code. If he engineer is certifying the construction, then the engineer is to certify the construction method per FAC 6915-G-18.011 and 69G15-29.001. | |||
| BLD | HOLD | 06/09/2022 | 06/10/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Residential REVIEW COMMENTS: 1. Submit plans showing changes. The plans submitted are from a previous submission dated 4-7-22. | |||
| BADMIN | INFORMATION | 06/07/2022 | 06/07/2022 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM Please rename your file according to the document submittal process. example site plan = site plan no names or numbers | |||
| BLD | HOLD | 04/21/2022 | 04/22/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. 2 x 6 proposed rafters are over spanned. FBC [A]107 | |||
| ZON | HOLD | 12/28/2021 | 12/28/2021 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please submit original 2' Easement Encroachment Agreement. | |||
| ZON | COMPLETE | 12/28/2021 | 12/28/2021 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/21/2021 | 12/21/2021 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please submit completed 2' Easement Encroachment License Agreement for Mechanical Equipment/Walkways as the door pad on left (also the existing walkway on the left) is encroaching in the easement. This agreement must be signed by all persons on deed, and must be notarized. Please provide this fully executed Agreement via online submittal for staff review before submitting original document. | |||
| ZON | HOLD | 12/15/2021 | 12/15/2021 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT Door pad is encroaching in the 5ft utility easement on the left side. It must meet a 5ft setback. Please specify that the patio walls will match existing structure material and color | |||
| ELEC | COMPLETE | 12/15/2021 | 12/15/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/15/2021 | 12/15/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/01/2021 | 12/02/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Provide Roofing Worksheet available at City's website. | |||
| ELEC | HOLD | 12/01/2021 | 12/01/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM List electrical sub contractor | |||
| MECH | CANCEL | 12/01/2021 | 12/01/2021 |
| Note: not needed | |||
| PLUM | CANCEL | 12/01/2021 | 12/02/2021 |
| SW1 | COMPLETE | 12/01/2021 | 12/02/2021 |
| Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/01/2021 | 12/01/2021 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Door pad is encroaching in the 5ft utility easement on the left side. It must meet a 5ft setback. Please specify that the patio walls will match existing structure material and color | |||
| PLFM | COMPLETE | 12/01/2021 | 12/01/2021 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM No comments as this addition is not part of the livable structure. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/15/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/17/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 12/28/2022 |
| PLAN REVIEW - REVISION | ¤32.50 | 12/28/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/28/2022 |
| RECORDING FEE REIMBURSE DOC | ¤35.50 | 01/28/2022 |
| SURCHARGE FS 533.721 | ¤2.97 | 01/28/2022 |
| SURCHARGE - FS 468.631 | ¤4.46 | 01/28/2022 |
| SW ENG - INSPECTION 20 | ¤20.00 | 01/28/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/28/2022 |
| SITE PLAN 30 | ¤30.00 | 01/28/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/28/2022 |
| INSPECTION - RESIDENTIAL | ¤165.00 | 01/28/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 01/28/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤557.93 |