Permit #2021120241
Permit Details
Status: COED
| Parcel Id: 35-11-31-4075-00000-1160 |
| COMMERCIAL SQUARE FOOTAGE: 2974 sqft |
| GARAGE: 670 sqft |
| OPENED PORCH (WITH ROOF) : 433 sqft |
| PATIO/DECK (NO ROOF) : 32 sqft |
| Total Square Footage: 4109 sqft |
| Block: 00000 |
| Subdivision: 2296 - MARINA DEL PALMA SUBDIVISION |
| Job Phone: 863-647-5815 |
| Location Address: 7 MENORCA WAY |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/10/2022 |
| NOC: RECORDED |
| Applicant name: MARK ALLAN HULBERT |
| Owner: MIGLIOZZI ANTHONY MATTHEW & JOAN ARLEEN H&W |
|
Address 12981 PAVILION COURT UNION, KY 41091 |
| Lot: 1160 |
| Contracted Stated Job Value: ¤480,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
HULBERT HOMES INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 6254 LAKELAND, FL 33813 |
CRC1331304 (Exp: 08/31/2026) | 863-647-5815 |
Sub Contractors
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
ANTONIO VINCENZO DAHM
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 RYBAR LANE PALM COAST, FL 32164 |
CFC1429951 (Exp: 08/31/2026) | 386-237-5692 |
MOISES MERINO DIAZ
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3104 ORANOLE ROAD ORLANDO, FL 32810 |
CAC1820980 (Exp: 08/31/2026) | 407-225-3149 |
Inspection History
| Type | Request Date | Result | Inspector |
| WINDOW NAILING | 02/17/2023 | FINAL APPROVED | TSTAUFFACHER |
| Note: 2/14/2023 - PREVIOUS INSPECTION NOTES Screws missing in header jamb on downstairs rear slider New inspection due to canceled inspection 11/3/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2490 10/17/2022 - PREVIOUS INSPECTION NOTES Need to call in window nailing (added) for missing slider doors prior to final 10-17-22 Not ready Still being insulated. 10.19.22 - several batts fell down from wind, ensure they are in place before drywalling 11-3-22 Missing Screws (check all) | |||
| BLD - BUILDING FINAL | 02/17/2023 | FINAL APPROVED | TSTAUFFACHER |
| Note: 2/14/2023 - PREVIOUS INSPECTION NOTES 02/14/2023- Multiple items incomplete or not installed house is not ready for final at this time. New inspection due to canceled inspection Need to call in window nailing (added) for missing slider doors Need revision on added electric by final | |||
| WINDOW NAILING | 02/14/2023 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Screws missing in header jamb on downstairs rear slider New inspection due to canceled inspection 11/3/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2490 10/17/2022 - PREVIOUS INSPECTION NOTES Need to call in window nailing (added) for missing slider doors prior to final 10-17-22 Not ready Still being insulated. 10.19.22 - several batts fell down from wind, ensure they are in place before drywalling 11-3-22 Missing Screws (check all) | |||
| BLD - BUILDING FINAL | 02/14/2023 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: 02/14/2023- Multiple items incomplete or not installed house is not ready for final at this time. New inspection due to canceled inspection Need to call in window nailing (added) for missing slider doors Need revision on added electric by final | |||
| WINDOW NAILING | 02/01/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 11/3/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2490 10/17/2022 - PREVIOUS INSPECTION NOTES Need to call in window nailing (added) for missing slider doors prior to final 10-17-22 Not ready Still being insulated. 10.19.22 - several batts fell down from wind, ensure they are in place before drywalling 11-3-22 Missing Screws (check all) | |||
| BLD - BUILDING FINAL | 02/01/2023 | CANCELLED BY APPLICANT | WEB |
| Note: Need to call in window nailing (added) for missing slider doors Need revision on added electric by final | |||
| U-CROSS CONNECTION | 01/26/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: please have Pressure breaker assembly equal or higher then hose bib/has potable irrigation with PVB installed-no cross connection | |||
| ROW - STORMWATER FINAL | 01/26/2023 | FINAL APPROVED | PFLANAGAN |
| U -UTILITY RESIDENTIAL FINAL | 01/26/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: use flush mount sewer clean out cap in future(not the current square nut type) | |||
| ROW - FINAL APRON (AFTER POUR) | 01/25/2023 | APPROVED | PFLANAGAN |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/25/2023 | APPROVED | PFLANAGAN |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/25/2023 | APPROVED | PFLANAGAN |
| Note: 1/17/2023 - PREVIOUS INSPECTION NOTES 01/17/23= YOU PROPOSE WAS WATER IS GOING FROM THE BACK TO THE FRONT, BUT IN YOU FINAL SURVEY YOU CHANGE THE FLOW OF THE WATER. NEED TO HAVE POSITE FALL IN EACH SIDE TO THE FRONT OF THE PROPERTY | |||
| FINAL SURVEY (OFFICE USE ONLY) | 01/17/2023 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 01/17/23= YOU PROPOSE WAS WATER IS GOING FROM THE BACK TO THE FRONT, BUT IN YOU FINAL SURVEY YOU CHANGE THE FLOW OF THE WATER. NEED TO HAVE POSITE FALL IN EACH SIDE TO THE FRONT OF THE PROPERTY | |||
| ELECTRIC - EARLY POWER | 01/17/2023 | APPROVED | LMILLER |
| Note: 1/13/2023 - PREVIOUS INSPECTION NOTES 1/10/2023 - PREVIOUS INSPECTION NOTES 1/5/2023 - PREVIOUS INSPECTION NOTES 1. Panel cover needs to be installed 2. Outlet upstairs needs to be safed off 1-10-23 Not ready. 1-13-23 Outlet in garage not safed off. 1-17-23 note above resolved | |||
| ELECTRIC - EARLY POWER | 01/13/2023 | Disapproved - NO FEE | BTAYLOR |
| Note: 1/10/2023 - PREVIOUS INSPECTION NOTES 1/5/2023 - PREVIOUS INSPECTION NOTES 1. Panel cover needs to be installed 2. Outlet upstairs needs to be safed off 1-10-23 Not ready. 1-13-23 Outlet in garage not safed off. | |||
| ELECTRIC - EARLY POWER | 01/10/2023 | Disapproved - NO FEE | BTAYLOR |
| Note: 1/5/2023 - PREVIOUS INSPECTION NOTES 1. Panel cover needs to be installed 2. Outlet upstairs needs to be safed off 1-10-23 Not ready. | |||
| ELECTRIC - EARLY POWER | 01/05/2023 | Disapproved - NO FEE | JMUNSON |
| Note: 1. Panel cover needs to be installed 2. Outlet upstairs needs to be safed off | |||
| GRAVITY SEWER TEST | 12/09/2022 | APPROVED | DCUSHING |
| U - SEWER TIE IN | 12/09/2022 | APPROVED | DCUSHING |
| ROW- PRE-APRON (PRE-POUR) | 12/07/2022 | APPROVED | PFLANAGAN |
| Note: READY FOR PAVERS ---------------------------------------------------- 12/6/2022 - PREVIOUS INSPECTION NOTES THIS IS NOT READY FOR THE SECOND INSPECTION THERE IS NO BASE SPREAD AND COMPACTED SEE PHOTOS OF THE RESULTS OF THE INSPECTION ---------------------------------------------------------------------------------------- 11/21/2022 - PREVIOUS INSPECTION NOTES READY TO POUR 1) APRON 2) SIDEWALK 3) PAVER RESTRAINTS ONLY BEFORE THE NEXT PRE POUR INSPECTION ALL PAVER BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS LAID | |||
| ROW- PRE-APRON (PRE-POUR) | 12/06/2022 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: THIS IS NOT READY FOR THE SECOND INSPECTION THERE IS NO BASE SPREAD AND COMPACTED SEE PHOTOS OF THE RESULTS OF THE INSPECTION ---------------------------------------------------------------------------------------- 11/21/2022 - PREVIOUS INSPECTION NOTES READY TO POUR 1) APRON 2) SIDEWALK 3) PAVER RESTRAINTS ONLY BEFORE THE NEXT PRE POUR INSPECTION ALL PAVER BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS LAID | |||
| ROW- PRE-APRON (PRE-POUR) | 11/21/2022 | PARTIALLY APPROVED | PFLANAGAN |
| Note: READY TO POUR 1) APRON 2) SIDEWALK 3) PAVER RESTRAINTS ONLY BEFORE THE NEXT PRE POUR INSPECTION ALL PAVER BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS LAID | |||
| LATH/BRICK/ WATER BARRIER | 11/15/2022 | APPROVED | DCUSHING |
| WINDOW NAILING | 11/03/2022 | Disapproved -FEE REQUIRED | LMILLER |
| Note: Inspector Notes from Inspection 2490 10/17/2022 - PREVIOUS INSPECTION NOTES Need to call in window nailing (added) for missing slider doors prior to final 10-17-22 Not ready Still being insulated. 10.19.22 - several batts fell down from wind, ensure they are in place before drywalling 11-3-22 Missing Screws (check all) | |||
| INSULATION | 10/19/2022 | APPROVED - AS NOTED | DCUSHING |
| Note: 10/17/2022 - PREVIOUS INSPECTION NOTES Need to call in window nailing (added) for missing slider doors prior to final 10-17-22 Not ready Still being insulated. 10.19.22 - several batts fell down from wind, ensure they are in place before drywalling | |||
| INSULATION | 10/17/2022 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: Need to call in window nailing (added) for missing slider doors prior to final 10-17-22 Not ready Still being insulated. | |||
| ALL ROUGH | 10/05/2022 | APPROVED | RMARTIN |
| Note: 9/20/2022 - PREVIOUS INSPECTION NOTES 9/19/2022 - PREVIOUS INSPECTION NOTES 09-19-2022 1. UFER ground not protected. UFER needs to be protected NEC 250.64. 2. Wires not phased out in electrical panel. 3. Drain pipe in garage needs plate at slab. NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE 4. Grounds not connected on second floor hallway. All grounds need to be connected – NEC 110.14A. Check all. 5. Outlet hanging in second floor master bath at pocket door, 6. Wire not connected at same area but different box. 7. Box loose and wires not fastened at second floor left of patio door. 9-20-22 1. 5ft head test 2. nail plates on electric 3. low voltage 1 1/4 from edge 4. fireblocking 5. fireblocking materials 6. nail plates on mechanical (liquid lines top plat (wrong nail plarte used) 7. plumbing is out of wall (down stairs) 8. A/C register is not mounted in bath down stairs 9. missing shower pans (and need to have test on pan/liner when installed) 10. Missing test on tub Need to call in window nailing (added) for missing slider doors prior to final Need revision on added electric by final | |||
| ALL ROUGH | 09/20/2022 | Disapproved -FEE REQUIRED | LMILLER |
| Note: 9/19/2022 - PREVIOUS INSPECTION NOTES 09-19-2022 1. UFER ground not protected. UFER needs to be protected NEC 250.64. 2. Wires not phased out in electrical panel. 3. Drain pipe in garage needs plate at slab. NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE 4. Grounds not connected on second floor hallway. All grounds need to be connected – NEC 110.14A. Check all. 5. Outlet hanging in second floor master bath at pocket door, 6. Wire not connected at same area but different box. 7. Box loose and wires not fastened at second floor left of patio door. 9-20-22 1. 5ft head test 2. nail plates on electric 3. low voltage 1 1/4 from edge 4. fireblocking 5. fireblocking materials 6. nail plates on mechanical (liquid lines top plat (wrong nail plarte used) 7. plumbing is out of wall (down stairs) 8. A/C register is not mounted in bath down stairs 9. missing shower pans (and need to have test on pan/liner when installed) 10. Missing test on tub Need to call in window nailing (added) for missing slider doors Need revision on added electric by final | |||
| ALL ROUGH | 09/19/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 09-19-2022 1. UFER ground not protected. UFER needs to be protected NEC 250.64. 2. Wires not phased out in electrical panel. 3. Drain pipe in garage needs plate at slab. NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE 4. Grounds not connected on second floor hallway. All grounds need to be connected – NEC 110.14A. Check all. 5. Outlet hanging in second floor master bath at pocket door, 6. Wire not connected at same area but different box. 7. Box loose and wires not fastened at second floor left of patio door. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/16/2022 | APPROVED | DCUSHING |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 7-19-22 1. missing nails at truss plates (highlighted on plans) 2. see symbol for Simpsonmissing HTT4 or double straps on second floor plan (highlighted) 7/22/22 The Htt4 nor the (2) LSTA18 tie downs have been installed the contrator installed H2.5 anchors. These are not sufficent for the required Uplift. The Htt4 or the LSTA's will need to be anchored to the CMU walls below. 08/10/2022-Prior inspector notes have not been completed. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/10/2022 | Disapproved -FEE REQUIRED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION 7-19-22 1. missing nails at truss plates (highlighted on plans) 2. see symbol for Simpsonmissing HTT4 or double straps on second floor plan (highlighted) 7/22/22 The Htt4 nor the (2) LSTA18 tie downs have been installed the contrator installed H2.5 anchors. These are not sufficent for the required Uplift. The Htt4 or the LSTA's will need to be anchored to the CMU walls below. 08/10/2022-Prior inspector notes have not been completed. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/22/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 7-19-22 1. missing nails at truss plates (highlighted on plans) 2. see symbol for Simpsonmissing HTT4 or double straps on second floor plan (highlighted) 7/22/22 The Htt4 nor the (2) LSTA18 tie downs have been installed the contrator installed H2.5 anchors. These are not sufficent for the required Uplift. The Htt4 or the LSTA's will need to be anchored to the CMU walls below. | |||
| ROOF VALLEY & METAL | 07/21/2022 | APPROVED | DCUSHING |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/19/2022 | Disapproved - NO FEE | LMILLER |
| Note: THIS IS A REINSPECTION need to organize paperwork, Please provide a set of plans and documents for inspectors to use at time of inspections that are organized, complete, and otherwise not crumpled and missing pages. it is apparent that the 4x4 posts are missing connection for Continuous load path… R301,2.1 (no connections on several areas) SP2 connectors have been deformed and used incorrectly (need a complete set of usable plans and documents for further inspection) Inspection Stopped. 7-19-22 1. missing nails at truss plates (highlighted on plans) 2. see symbol for Simpsonmissing HTT4 or double straps on second floor plan (highlighted) | |||
| WALL SHEATHING | 07/19/2022 | APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION need to organize paperwork, Please provide a set of plans and documents for inspectors to use at time of inspections that are organized, complete, and otherwise not crumpled and missing pages 7-19-22 notes above resolved | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/13/2022 | Disapproved -FEE REQUIRED | LMILLER |
| Note: need to organize paperwork, Please provide a set of plans and documents for inspectors to use at time of inspections that are organized, complete, and otherwise not crumpled and missing pages. it is apparent that the 4x4 posts are missing connection for Continuous load path… R301,2.1 (no connections on several areas) SP2 connectors have been deformed and used incorrectly (need a complete set of usable plans and documents for further inspection) Inspection Stopped. | |||
| WALL SHEATHING | 07/13/2022 | Disapproved - NO FEE | LMILLER |
| Note: need to organize paperwork, Please provide a set of plans and documents for inspectors to use at time of inspections that are organized, complete, and otherwise not crumpled and missing pages | |||
| ELECTRIC-TUG | 06/10/2022 | APPROVED - AS NOTED | RMARTIN |
| FOUND SURVEY APPROVED (OFFICE) | 05/16/2022 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 05/09/2022 | APPROVED | KSANDOE |
| WATER METER INSTALLATION REQUEST | 03/29/2022 | APPROVED | CSTONE |
| MONOLITHIC SLAB | 03/22/2022 | APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION need compaction report on site 3-22-22 notes above resolved | |||
| MONOLITHIC SLAB | 03/18/2022 | Disapproved - NO FEE | LMILLER |
| Note: need compaction report on site | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/07/2022 | APPROVED | MGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 09/20/2022 | 09/20/2022 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Rename your file to the plan sheet name | |||
| BLD | COMPLETE | 08/11/2022 | 08/15/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 07/26/2022 | 07/27/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: Repeat Comments 1. Provide product approval for the proposed FramFAST fasteners. 2. Simpson HTT4 had an uplift design of 3105 and LSTA18 designed of 1235. Provide the uplift of the proposed fastener can meet the required up lift. | |||
| ENGIN1 | COMPLETE | 05/16/2022 | 05/16/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/16/2022 | 05/16/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/05/2022 | 01/06/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/30/2021 | 01/03/2022 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Product approval for wood anchors is still missing. Provide only one(1) FL Number. | |||
| MECH | COMPLETE | 12/16/2021 | 12/17/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/16/2021 | 12/17/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/16/2021 | 12/16/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Repeat Comment 1. Provide components and cladding pressure zones per FBCR 7th Edition, Figure R301.2(7). 2. OK | |||
| ENGIN1 | COMPLETE | 12/16/2021 | 12/17/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/16/2021 | 12/28/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 12/07/2021 | 12/08/2021 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - | |||
| BLD | HOLD | 12/06/2021 | 12/10/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM 1. Provide components and cladding pressure zones per FBCR 7th Edition, Figure R301.2(7). 2. Provide product approval of garage door, wood anchors and truss plates per F.S. 553.842. | |||
| CUSVC | COMPLETE | 12/06/2021 | 12/10/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 12/06/2021 | 12/06/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/06/2021 | 12/06/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 12/06/2021 | 12/08/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 12/06/2021 | 12/07/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder | |||
| SW1 | COMPLETE | 12/06/2021 | 12/14/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/06/2021 | 12/07/2021 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Survey/ Site plan : state 1 story plpans show two story home, please correct |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 02/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/17/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 02/17/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 02/17/2023 |
| REINSPECTION FEE | ¤40.00 | 02/17/2023 |
| SURCHARGE FS 533.721 | ¤17.99 | 01/10/2022 |
| SURCHARGE - FS 468.631 | ¤26.99 | 01/10/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 01/10/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 01/10/2022 |
| SW ENG PRE APRON | ¤30.00 | 01/10/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/10/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 01/10/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤94.17) | 01/10/2022 |
| SEWER INSPECTION | ¤25.00 | 01/10/2022 |
| SEWER CAPITAL FACILITY | ¤2,607.06 | 01/10/2022 |
| WATER CAPITAL FACILITY FEE | ¤2,436.75 | 01/10/2022 |
| SITE PLAN 30 | ¤30.00 | 01/10/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 01/10/2022 |
| IMPACT FEE FIRE | ¤388.65 | 01/10/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 01/10/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 01/10/2022 |
| IMPACT FEE TRANSPORTATION | ¤3,139.00 | 01/10/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 01/10/2022 |
| METER - DEPOSIT | ¤60.00 | 01/10/2022 |
| WATER-METER | ¤467.09 | 01/10/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/10/2022 |
| INSPECTION - RESIDENTIAL | ¤1,320.00 | 01/10/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤374.40 | 01/10/2022 |
| CONNECTION FEES | ¤25.00 | 01/10/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤16,566.08 |