I want to search for...
Permit #2021120285
Permit Details
Status: COED
| Parcel Id: 07-11-31-7057-00360-0100 |
| CONDITIONED SPACE: 2536 sqft |
| GARAGE: 500 sqft |
| OPENED PORCH (WITH ROOF) : 191 sqft |
| OPENED PORCH (WITH ROOF) : 226 sqft |
| Total Square Footage: 3453 sqft |
| Block: 00360 |
| Subdivision: 2123 - SECTION 57-ULYSSES TREES |
| Job Phone: (386) 445-2222 |
| Location Address: 6 UPSHUR CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/20/2021 |
| NOC: RECORDED |
| Applicant name: MICHAEL STEPHAN MULLEN |
| Owner: KENNETH AND KRISTINA UDELL |
|
Address 6 UPSHUR CT PALM COAST, FL 32164 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
TOWN & COUNTRY HOMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1 Enterprise Drive Bunnell, FL 32110 |
CGC049972 (Exp: 08/31/2026) | (386) 445-2222 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
YORDANIS GONZALEZ
| Status | Location Address | State License Number | Phone |
| ACTIVE |
33 RICKENBACKER DRIVE PALM COAST, FL 32164 |
CCC1328730 (Exp: 08/31/2026) | 386-804-4109 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
Inspection History
| Type | Request Date | Result | Inspector |
| U-CROSS CONNECTION | 01/26/2023 | APPROVED - AS NOTED | JHARDING |
| Note: 1/24/2023 - PREVIOUS INSPECTION NOTES Not Ready 1/25/2023 No cross connections. | |||
| ROW - STORMWATER FINAL | 01/26/2023 | FINAL APPROVED | PFLANAGAN |
| Note: ALL CORRECTIONS MADE 1/23/2023 - PREVIOUS INSPECTION NOTES 1) NEED THE PORTER JOHN REMOVED AND HAVE SOD WHERE THE PORTER JOHN WAS SITTING 2) NEED TO HAVE SEED AND STRAW ON ALL BARE AREAS ON THE VACANT LOT TO THE RIGHT OF YOURS AND AND SLOPE GREATER 4:1 NEED TO HAVE SOD | |||
| U-CROSS CONNECTION | 01/25/2023 | CANCELLED BY APPLICANT | JHARDING |
| Note: Not Ready | |||
| BLD - BUILDING FINAL | 01/24/2023 | FINAL APPROVED | BTAYLOR |
| Note: 1/23/2023 - PREVIOUS INSPECTION NOTES 1-23-23 1. Wrong size breaker for air handler unit. | |||
| BLD - BUILDING FINAL | 01/23/2023 | Disapproved - NO FEE | BTAYLOR |
| Note: 1-23-23 1. Wrong size breaker for air handler unit. | |||
| ROW - STORMWATER FINAL | 01/23/2023 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) NEED THE PORTER JOHN REMOVED AND HAVE SOD WHERE THE PORTER JOHN WAS SITTING 2) NEED TO HAVE SEED AND STRAW ON ALL BARE AREAS ON THE VACANT LOT TO THE RIGHT OF YOURS AND AND SLOPE GREATER 4:1 NEED TO HAVE SOD | |||
| U -UTILITY RESIDENTIAL FINAL | 01/23/2023 | FINAL APPROVED | JHARDING |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/20/2023 | APPROVED | PFLANAGAN |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/20/2023 | APPROVED | PFLANAGAN |
| ROW - FINAL APRON (AFTER POUR) | 01/20/2023 | APPROVED | PFLANAGAN |
| ELECTRIC - EARLY POWER | 12/15/2022 | APPROVED | BTAYLOR |
| ROW- PRE-APRON (PRE-POUR) | 11/18/2022 | APPROVED | PFLANAGAN |
| Note: IT'S THE CONTRACTORS RESPONSIBILITY TO CHECK THE CULVERT PIPE ELEVATIONS BEFORE POURING CONCRETE FOR THE DRIVEWAY ------------------------------------------------------------------------------------------------ 11/15/2022 - PREVIOUS INSPECTION NOTES 1) SOIL AROUND CULVERT PIPE IS TO SOFT NEED TO HAVE 95% COMPACTION IN THE ENTIRE POURING AREA 2) THE LEFT END OF THE CULVERT IS NOT THE MINIMUM DISTANCE FROM EDGE OF PAVEMENT CULVERTS IN A CAL DE SAC NEED TO BE 5' FROM EDGE OF PAVEMENT | |||
| ROW- PRE-APRON (PRE-POUR) | 11/17/2022 | CANCELLED BY APPLICANT | PFLANAGAN |
| Note: 11/15/2022 - PREVIOUS INSPECTION NOTES 1) SOIL AROUND CULVERT PIPE IS TO SOFT NEED TO HAVE 95% COMPACTION IN THE ENTIRE POURING AREA 2) THE LEFT END OF THE CULVERT IS NOT THE MINIMUM DISTANCE FROM EDGE OF PAVEMENT CULVERTS IN A CAL DE SAC NEED TO BE 5' FROM EDGE OF PAVEMENT | |||
| ROW- PRE-APRON (PRE-POUR) | 11/15/2022 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) SOIL AROUND CULVERT PIPE IS TO SOFT NEED TO HAVE 95% COMPACTION IN THE ENTIRE POURING AREA 2) THE LEFT END OF THE CULVERT IS NOT THE MINIMUM DISTANCE FROM EDGE OF PAVEMENT CULVERTS IN A CAL DE SAC NEED TO BE 5' FROM EDGE OF PAVEMENT | |||
| LATH/BRICK/ WATER BARRIER | 09/26/2022 | Disapproved - NO FEE | BTAYLOR |
| Note: 9-26-22 1. No wire lath on gable. | |||
| LATH/BRICK/ WATER BARRIER | 09/26/2022 | APPROVED | BTAYLOR |
| Note: 9/26/2022 - PREVIOUS INSPECTION NOTES | |||
| GRAVITY SEWER TEST | 09/23/2022 | APPROVED | MGIBSON |
| U - SEWER TIE IN | 09/23/2022 | APPROVED | MGIBSON |
| INSULATION | 09/19/2022 | APPROVED | BTAYLOR |
| Note: 9/15/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 8-30-22 1. A/C duct ripped in left rear room. 9-15-22 1. Holes in top plates need fire foam. 2. Need proof that foam installed has ignition barrier intergrated in it due to storage space in garage. FBC R316. | |||
| INSULATION | 09/15/2022 | Disapproved - NO FEE | BTAYLOR |
| Note: Inspector Notes from Inspection 2420 8-30-22 1. A/C duct ripped in left rear room. 9-15-22 1. Holes in top plates need fire foam. 2. Need proof that foam installed has ignition barrier intergrated in it due to storage space in garage. FBC R316. | |||
| ALL ROUGH | 08/30/2022 | APPROVED - AS NOTED | BTAYLOR |
| Note: 8-30-22 1. A/C duct ripped in left rear room. | |||
| ELECTRIC-TUG | 08/23/2022 | APPROVED | BTAYLOR |
| Note: THIS IS A REINSPECTION ADDED ON 8/19/2022 3:51:05 PM | |||
| ELECTRIC-TUG | 08/22/2022 | CANCELLED BY APPLICANT | MRAMOS |
| WALL SHEATHING | 06/02/2022 | APPROVED | RMARTIN |
| ROOF VALLEY & METAL | 06/02/2022 | APPROVED | RMARTIN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/26/2022 | APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Gable rafter tie downs not fastened to trusses below Roof sheathing has large gaps, H Clips not engaged in several areas | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/24/2022 | Disapproved - NO FEE | DCUSHING |
| Note: Gable rafter tie downs not fastened to trusses below Roof sheathing has large gaps, H Clips not engaged in several areas | |||
| DOWN CELL | 05/24/2022 | APPROVED | DCUSHING |
| Note: THIS IS A REINSPECTION Multiple bar do not meet 3/4 clearance Bar on right side near rear of home needs to be drilled and epoxied//loose and outside footing Was re-checked w/ concrete sub on site | |||
| FOUND SURVEY APPROVED (OFFICE) | 05/23/2022 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 04/26/2022 | APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Multiple bar do not meet 3/4" clearance guidelines Bar on right side near rear ouside footing and loose--drill and epoxy | |||
| DOWN CELL | 04/25/2022 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Multiple bar do not meet 3/4 clearance Bar on right side near rear of home needs to be drilled and epoxied//loose and outside footing | |||
| TIE BEAM / LINTEL | 04/25/2022 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Multiple bar do not meet 3/4" clearance guidelines Bar on right side near rear ouside footing and loose--drill and epoxy | |||
| MONOLITHIC SLAB | 03/07/2022 | APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Pipes passing through footings must have either a sleeve or bridge. Dont forget your electric chase at island | |||
| MONOLITHIC SLAB | 02/28/2022 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Pipes passing through footings must have either a sleeve or bridge. Dont forget your electric chase at island | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/22/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 01/28/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 09/13/2022 | 09/13/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 08/12/2022 | 08/12/2022 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Rename your file to gas riser diagram. | |||
| ENGIN1 | COMPLETE | 05/19/2022 | 05/23/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/19/2022 | 05/19/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM no zoning changes | |||
| MECH | COMPLETE | 12/17/2021 | 12/17/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/14/2021 | 12/14/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 12/14/2021 | 12/14/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Orientation of Energy calcs does not match the site plan. Revise to match. (Second Request) | |||
| ZON | COMPLETE | 12/14/2021 | 12/14/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 12/07/2021 | 02/02/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/06/2021 | 12/10/2021 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 12/06/2021 | 12/10/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | HOLD | 12/06/2021 | 12/07/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to have correct outlet spacing in nook area. NEC 2017 210.52 2. Need to add outlet in garage. NEC 210.52 (G) (1) | |||
| ENGIN1 | COMPLETE | 12/06/2021 | 12/07/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 12/06/2021 | 12/08/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 12/06/2021 | 12/07/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Orientation of Energy calcs does not match the site plan. Revise to match 2. Energy Calcs need to be signed by the builder | |||
| SW1 | COMPLETE | 12/06/2021 | 12/14/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/06/2021 | 12/08/2021 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM landscape plan: Grass being placed and if it will need an irrigation system. mechanical equiptment must be screened it by seven gallon shrubs please correct. site plan mising right rear set set back. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG REINSPECTION 20 | ¤20.00 | 01/26/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 01/19/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 01/19/2023 |
| CONTRACTOR CHANGE | ¤40.00 | 01/27/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 12/20/2021 |
| IMPACT FEE FIRE | ¤388.65 | 12/20/2021 |
| IMPACT FEE PARKS | ¤1,455.13 | 12/20/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 12/20/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 12/20/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 12/20/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 12/20/2021 |
| SURCHARGE FS 533.721 | ¤12.16 | 12/20/2021 |
| SURCHARGE - FS 468.631 | ¤18.25 | 12/20/2021 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 12/20/2021 |
| SW ENG INSPECTION 80 | ¤80.00 | 12/20/2021 |
| SW ENG PRE APRON | ¤30.00 | 12/20/2021 |
| SW ENG - REVIEW 20 | ¤20.00 | 12/20/2021 |
| SW ENG RES REVIEW 200 | ¤200.00 | 12/20/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 12/20/2021 |
| SEWER INSPECTION | ¤25.00 | 12/20/2021 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 12/20/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 12/20/2021 |
| SITE PLAN 30 | ¤30.00 | 12/20/2021 |
| CONNECTION FEES | ¤1,077.88 | 12/20/2021 |
| METER - DEPOSIT | ¤60.00 | 12/20/2021 |
| WATER- TURN ON | ¤25.00 | 12/20/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/20/2021 |
| INSPECTION - RESIDENTIAL | ¤877.25 | 12/20/2021 |
| PLAN REVIEW - RESIDENTIAL | ¤248.82 | 12/20/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤18,523.05 |