I want to search for...
Permit #2021120397
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7032-00470-0090 |
| Block: 00470 |
| Subdivision: 2155 - SECTION 32-ROYAL PALMS |
| Job Phone: 386-423-0656 |
| Location Address: 92 ROXBORO DR |
| Type: RF - REROOF |
| Issue Date: 12/08/2021 |
| NOC: RECORDED |
| Applicant name: MICHELE TAUSCHER |
| Owner: VAN DEWERKER GERALD & MONICA H&W |
|
Address 92 ROXBORO DRIVE PALM COAST, FL 32164 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤17,000.00 |
| Job Description: Remove and replace shingle roof system Fl#10124.1-R31, FL#10626.1-R22 |
| Type: CN |
Contractor
SUN COAST ROOFING SERVICES INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
843 NORTH DIXIE FREEWAY NEW SMYRNA, FL 32168 |
CCC1329155 (Exp: 08/31/2026) | 386-423-0656 | 386-423-0676 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROOF FINAL | 03/02/2022 | FINAL APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION The roof is not complete. Workers still installing shingles. 1/31/22 The ventilation of the roof does not appear to be sufficent for the size of the roof. R806.2 Minimum vent area. The minimum net free ventilating area shall be 1/150 of the area of the vented space. Add necessary ventilation or submitt worksheet to the building department for system used. Materials have and trash have been left of site. 13 bundles of shingles and 2 sheets of plywood. Next to driveway and trash on the left side of the home. 2/1/22 The ventilation of the roof has not been addressed. No new vents have been installed There is still roofing debri on the left side of the home. | |||
| ROOF FINAL | 02/01/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION The roof is not complete. Workers still installing shingles. 1/31/22 The ventilation of the roof does not appear to be sufficent for the size of the roof. R806.2 Minimum vent area. The minimum net free ventilating area shall be 1/150 of the area of the vented space. Add necessary ventilation or submitt worksheet to the building department for system used. Materials have and trash have been left of site. 13 bundles of shingles and 2 sheets of plywood. Next to driveway and trash on the left side of the home. 2/1/22 The ventilation of the roof has not been addressed. No new vents have been installed There is still roofing debri on the left side of the home. | |||
| ROOF FINAL | 01/31/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: THIS IS A REINSPECTION The roof is not complete. Workers still installing shingles. 1/31/22 The ventilation of the roof does not appear to be sufficent for the size of the roof. R806.2 Minimum vent area. The minimum net free ventilating area shall be 1/150 of the area of the vented space. Add necessary ventilation or submitt worksheet to the building department for system used. Materials have and trash have been left of site. 13 bundles of shingles and 2 sheets of plywood. Next to driveway and trash on the left side of the home. | |||
| ROOF FINAL | 01/28/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: The roof is not complete. Workers still installing shingles. | |||
| ROOF AFFIDAVIT | 01/27/2022 | APPROVED | LMUSGROVE |
| ROOF IN PROGRESS- MIDROOF | 01/27/2022 | APPROVED | JWALKER |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | COMPLETE | 01/27/2022 | 01/27/2022 |
| Note: Released By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 01/26/2022 | 01/26/2022 |
| Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM LICENSE INACTIVE. CAN NOT APPROVE INSPECTION FOR ROOFING AFFIDAVIT. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/31/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/28/2022 |
| SURCHARGE FS 533.721 | ¤2.00 | 12/08/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 12/08/2021 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/08/2021 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 12/08/2021 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤174.00 |