Permit #2021120412
Permit Details
Status: CANCEL
| Parcel Id: 27-10-30-0000-01010-0011 |
| Block: 01010 |
| Subdivision: - |
| Job Phone: 386-446-6426 |
| Location Address: 800 MATANZAS WOODS PKWY |
| Type: FU - FIRE UNDERGROUND |
| NOC: NO DOCUMENTATION |
| Applicant name: SCOTT DALE SOWERS |
| Owner: FLAGLER HOSPITAL INC |
|
Address 400 HEALTH PARK BLVD ST AUGUSTINE, FL 32084 |
| Lot: 0011 |
| Contracted Stated Job Value: ¤32,280.00 |
| Job Description: Underground Fire Line |
| Type: CN |
Contractor
S E CLINE CONSTRUCTION INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 354425 PALM COAST, FL 32137 |
FPC12-000038 (Exp: 06/30/2026) | 386-446-6426 | 386-446-6481 |
Inspection History
| Type | Request Date | Result | Inspector |
| FIRE SYSTEM FLUSH | |||
| FIRE MAIN PLACEMENT /SIZE/THRUST /BLOCKING | |||
| FIRE MAIN HYDROSTATIC/BACKFLOW PREVENTOR | |||
| FIRE FINAL | |||
| ROW - FINAL INSPECTION |
Review History
| Department | Status | Date In | Date Out |
| FI1 | HOLD | 12/09/2021 | 12/14/2021 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM All comments below per the 2020 Florida Fire Prevention Code. 1. Please include code analysis using 2020 FFPC seventh edition and 2020 FBC seventh edition 2. Please provide a written response to each comment below and location in your response letter. 3. Please supply Material specs for all materials (need Material List for Riser, Hydrant, Pipe, Restraints, Tracer Wire, Fittings, Valves, Check Valves, FDC’s etc.) 4. Please supply Manufacturer Installation Instructions for all Material to be installed. 5. Please provide detail w-27 for dedicated fire flow assembly 6. Please provide FDC Detail 7. Please provide calculations for the fire flow and minimum Hydrants needed to achieve the minimum required fire flow as it relates to the 7th edition of FFPC 1, Chapter 18.4 and the correlated Hydrants. To further clarify: The fire flow and duration is calculated via the applicable codes in the 7th edition of FFPC 1, Chapter 18.4 and Table 18.4.5.2.1 and the hydrants required for the flow as indicated in the 7th edition of FFPC 1, Chapter 18.5, 18.5.3, 18.5.4, 18.5.4.1, 18.5.4.2, and Table 18.5.4.3 gives the maximum allowed GPM to be considered per Hydrant as it relates to the distance to the building measured in accordance with building type and the requirements of the FFPC 1, Chapter 18.2.3 along the Fire Department Access Road with a minimum 20 PSI Residual. | |||
| UD1 | CANCEL | 12/09/2021 | 12/09/2021 |
| FI1 | CANCEL |