I want to search for...

Permit #2021120505

Permit Details

Status: COED

Parcel Id: 07-11-31-7022-00110-0100
CONDITIONED SPACE: 2023 sqft
GARAGE: 724 sqft
OPENED PORCH (WITH ROOF) : 210 sqft
Total Square Footage: 2957 sqft
Block: 00110
Subdivision: 2217 - SECTION 22-WYNNFIELD
Job Phone: 386-445-3405
Location Address: 34 WESTBURY LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/22/2022
NOC: RECORDED
Applicant name: JAY DARREN CURBOW
Owner: BLUE WATER HOMES INC

Address

STE #1

PALM COAST, FL 32137

Address

4881 PALM COAST PKWY NW

PALM COAST, FL 32137

Lot: 0100
Contracted Stated Job Value: ¤239,135.00
Job Description: Single Family Residence
Type: CN

Contractor

BLUE WATER HOMES INC
Status Location Address State License Number Phone
ACTIVE

4881 PALM COAST PARKWAY NW UNIT 1

PALM COAST, FL 32137

CBC1258679 (Exp: 08/31/2026) 386-445-3405

Sub Contractors

JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/23/2023 FINAL APPROVED MKRASKI
BLD - BUILDING FINAL 02/22/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Outside hose bibs missing back flow preventers 2. Water supply shut off outside needs a hand hole for access 3. Ufer ground needs to be accessible 4. Extra construction materials need to be removed (doors) 5. No hot water in master bathroom 6. outlets not working in master bathroom Stopped inspection, not ready, stopped in master bedroom did not check kitchen, living or spare bedrooms.
BLD - BUILDING FINAL 02/16/2023 CANCELLED BY APPLICANT MKRASKI
ROW- PROJECT STATUS 02/08/2023 APPROVED GBERTOLA
Note: bUILDER ASK ME TO CHECK THE RIGHT SIDE SWALE
ROW - STORMWATER FINAL 02/08/2023 APPROVED GBERTOLA
Note: 2/8/23=CORRECTION WERE MADE 2/1/2023 - PREVIOUS INSPECTION NOTES 02/01/23=NEED TO BUILD UP THE RIGHT SIDE SWALE MATCH EXISTING GRADE AT EACH PROPERTY LINE. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1/31/2023 - PREVIOUS INSPECTION NOTES NEED TO PICK ALL TRASH AND CONSTRUCTION DEBRIS FROM LOT -------------------------------------------------------------------------- 1/11/2023 - PREVIOUS INSPECTION NOTES 01/11/23=need to MATCH EXISTING GRADE ON THE RIGHT SIDE. _______________________________________________________________________________________________________________________
ROW- PROJECT STATUS 02/03/2023 APPROVED GBERTOLA
Note: 02/3/23=builder ask me to stop by and LOOK THE REPAIR THEY NEED TO RISE THE SWALE
ROW - STORMWATER FINAL 02/01/2023 Disapproved -FEE REQUIRED GBERTOLA
Note: 02/01/23=NEED TO BUILD UP THE RIGHT SIDE SWALE MATCH EXISTING GRADE AT EACH PROPERTY LINE. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1/31/2023 - PREVIOUS INSPECTION NOTES NEED TO PICK ALL TRASH AND CONSTRUCTION DEBRIS FROM LOT -------------------------------------------------------------------------- 1/11/2023 - PREVIOUS INSPECTION NOTES 01/11/23=need to MATCH EXISTING GRADE ON THE RIGHT SIDE. _______________________________________________________________________________________________________________________
ROW - STORMWATER FINAL 01/31/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: NEED TO PICK ALL TRASH AND CONSTRUCTION DEBRIS FROM LOT -------------------------------------------------------------------------- 1/11/2023 - PREVIOUS INSPECTION NOTES 01/11/23=need to MATCH EXISTING GRADE ON THE RIGHT SIDE. ON THE BACK OF THE HOUSE RUN FLAT.Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) WATER NEED GO AWAY FROM THE HOUSE _______________________________________________________________________________________________________________________ at the END of the swale NEED TO CUT DOWM A HUMP BLOCKING THE FLOW OF THE WATER , WATER FLOW FROM THE LEFT TO RIGHT ACCORDING TO THE SWALE PLAN DETAIL
U -UTILITY RESIDENTIAL FINAL 01/11/2023 APPROVED - AS NOTED LFITZGERALD
Note: clean out water meter pit of all soils-contact me 386-286-2041 for a post inspection
ROW - STORMWATER FINAL 01/11/2023 Disapproved -FEE REQUIRED GBERTOLA
Note: 01/11/23=need to MATCH EXISTING GRADE ON THE RIGHT SIDE. ON THE BACK OF THE HOUSE RUN FLAT.Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) WATER NEED GO AWAY FROM THE HOUSE _______________________________________________________________________________________________________________________ at the END of the swale NEED TO CUT DOWM A HUMP BLOCKING THE FLOW OF THE WATER , WATER FLOW FROM THE LEFT TO RIGHT ACCORDING TO THE SWALE PLAN DETAIL
U-CROSS CONNECTION 01/11/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ROW - FINAL APRON (AFTER POUR) 01/11/2023 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
U - SEWER TIE IN 01/09/2023 APPROVED - AS NOTED MGIBSON
Note: 9/26/2022 - PREVIOUS INSPECTION NOTES Tie in has been back filled THIS WS A VIRTUAL INSPECTION
TUB SET 01/06/2023 APPROVED MKRASKI
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/15/2022 APPROVED GBERTOLA
ROW FIELD SURVEY /GRADING CERTIFICATION 12/15/2022 APPROVED GBERTOLA
ROW- PRE-APRON (PRE-POUR) 11/07/2022 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ELECTRIC - EARLY POWER 10/27/2022 APPROVED JMUNSON
U - SEWER TIE IN 09/26/2022 Disapproved - NO FEE MKRASKI
Note: Tie in has been back filled
U - SEWER TIE IN 09/21/2022 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 09/09/2022 APPROVED MKRASKI
INSULATION 08/31/2022 APPROVED MKRASKI
ALL ROUGH 08/23/2022 APPROVED - AS NOTED MKRASKI
Note: Added tub set inspection, drain for tub will need to be sealed at tub set inspection
ROOF VALLEY & METAL 08/10/2022 APPROVED MKRASKI
ROOF VALLEY & METAL 08/03/2022 Disapproved - NO FEE MKRASKI
Note: Drip edge missing by front entry
WALL SHEATHING 08/02/2022 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/02/2022 APPROVED MKRASKI
TIE BEAM / LINTEL 07/08/2022 APPROVED FWILLIS
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1. GROUTED SOLID… REQUIREMENTS FOR GROUTED MASONRY… FBC, R606.3.5.2 FOREIGN MATER NEEDS TO BE REMOVED (front collumn and back right cornera) 2. CLEARANCE FROM EARTH AND WEATHER R606.13.5 REINFORCING BARS USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER, INCLUDUNG GROUT, OF NOT LESS THAN 2 inches FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER AND 1.5 inches NOT EXPOSED TO EARTH OR WEATHER (Front collumn) 3. Bed Joints at window sills are not within tollerance 606.3.1 (Max 1/2 inch) 7/6/22 No corrections have been made
TIE BEAM / LINTEL 07/06/2022 Disapproved -FEE REQUIRED MKRASKI
Note: THIS IS A REINSPECTION 1. GROUTED SOLID… REQUIREMENTS FOR GROUTED MASONRY… FBC, R606.3.5.2 FOREIGN MATER NEEDS TO BE REMOVED (front collumn and back right cornera) 2. CLEARANCE FROM EARTH AND WEATHER R606.13.5 REINFORCING BARS USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER, INCLUDUNG GROUT, OF NOT LESS THAN 2 inches FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER AND 1.5 inches NOT EXPOSED TO EARTH OR WEATHER (Front collumn) 3. Bed Joints at window sills are not within tollerance 606.3.1 (Max 1/2 inch) 7/6/22 No corrections have been made
FOUND SURVEY APPROVED (OFFICE) 06/29/2022 APPROVED TBAKER
TIE BEAM / LINTEL 06/27/2022 Disapproved -FEE REQUIRED LMILLER
Note: 1. GROUTED SOLID… REQUIREMENTS FOR GROUTED MASONRY… FBC, R606.3.5.2 FOREIGN MATER NEEDS TO BE REMOVED (front collumn and back right cornera) 2. CLEARANCE FROM EARTH AND WEATHER R606.13.5 REINFORCING BARS USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER, INCLUDUNG GROUT, OF NOT LESS THAN 2 inches FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER AND 1.5 inches NOT EXPOSED TO EARTH OR WEATHER (Front collumn) 3. Bed Joints at window sills are not within tollerance 606.3.1 (Max 1/2 inch)
MONOLITHIC SLAB 06/06/2022 APPROVED KSANDOE
GRAVITY SEWER TEST 05/31/2022 APPROVED MGIBSON
PLUMBING 1ST ROUGH UNDERGROUND 05/27/2022 APPROVED - AS NOTED MGIBSON
Note: GRAVITY SEWER NEEDS TO BE SCHEDULED FOR TUESDAY
WATER METER INSTALLATION REQUEST 05/04/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 06/29/2022 06/29/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/29/2022 06/29/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 12/10/2021 12/14/2021
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
CUSVC COMPLETE 12/10/2021 12/16/2021
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 12/10/2021 12/10/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/10/2021 12/10/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 12/10/2021 12/14/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 12/10/2021 12/13/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 12/10/2021 12/17/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM
ZON COMPLETE 12/10/2021 12/10/2021
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 12/10/2021 02/08/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/23/2023
REINSPECTION RESIDENTIAL ¤40.00 02/23/2023
REINSPECTION RESIDENTIAL ¤40.00 02/23/2023
CONTRACTOR CHANGE ¤40.00 02/23/2023
CONTRACTOR CHANGE ¤40.00 02/23/2023
CONTRACTOR CHANGE ¤20.00 02/23/2023
SW ENG REINSPECTION 20 ¤20.00 02/23/2023
SW ENG REINSPECTION 20 ¤20.00 02/23/2023
SW ENG REINSPECTION 20 ¤20.00 02/23/2023
SW ENG REINSPECTION 20 ¤20.00 02/23/2023
SW ENG REINSPECTION 20 ¤20.00 02/23/2023
SW ENG - REVIEW 20 ¤20.00 03/22/2022
SW ENG RES REVIEW 200 ¤200.00 03/22/2022
3% TRANS IMPACT FEE CREDIT (¤51.54) 03/22/2022
SEWER CREDIT (¤1,466.00) 03/22/2022
SEWER INSPECTION ¤25.00 03/22/2022
SEWER CAPITAL FACILITY ¤4,939.76 03/22/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 03/22/2022
SITE PLAN 30 ¤30.00 03/22/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 03/22/2022
IMPACT FEE FIRE ¤388.65 03/22/2022
IMPACT FEE PARKS ¤1,455.13 03/22/2022
IMPACT FEE SCHOOL ¤3,600.00 03/22/2022
IMPACT FEE TRANSPORTATION ¤1,718.00 03/22/2022
WATER -IRRIGATION INSPECTION ¤25.00 03/22/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 03/22/2022
SURCHARGE FS 533.721 ¤9.30 03/22/2022
SURCHARGE - FS 468.631 ¤13.95 03/22/2022
SW ENG - FOUNDATION SURVEY ¤20.00 03/22/2022
SW ENG INSPECTION 80 ¤80.00 03/22/2022
SW ENG PRE APRON ¤30.00 03/22/2022
CONNECTION FEES ¤1,077.88 03/22/2022
METER - DEPOSIT ¤60.00 03/22/2022
WATER- TURN ON ¤25.00 03/22/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/22/2022
INSPECTION - RESIDENTIAL ¤660.00 03/22/2022
PLAN REVIEW - RESIDENTIAL ¤186.58 03/22/2022
Fees Total Due: ¤0.00 Total Paid: ¤16,967.90