I want to search for...
Permit #2021120564
Permit Details
Status: COED
| Parcel Id: 07-11-31-7010-00010-0100 |
| CONDITIONED SPACE: 2196 sqft |
| GARAGE: 657 sqft |
| OPENED PORCH (WITH ROOF) : 48 sqft |
| OPENED PORCH (WITH ROOF) : 368 sqft |
| CONDITIONED SPACE: 39 sqft |
| Total Square Footage: 3308 sqft |
| Block: 00010 |
| Subdivision: 2137 - SECTION 10-FLORIDA PARK |
| Job Phone: 386-445-2012 |
| Location Address: 116 FERNDALE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/07/2022 |
| NOC: RECORDED |
| Applicant name: JOHN NICHOLAS CORDASCI |
| Owner: TEA VENG K & RIAN L CHANTHACHAEM H&W |
|
Address 16813 NE 35TH PLACE BELLEVUE, WA 98008 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤393,280.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SKYWAY BUILDERS INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 354786 PALM COAST, FL 32135 |
CBC1263769 (Exp: 08/31/2024) | 386-445-2012 |
Sub Contractors
MARK JOHN LUTCZA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
26 ROYAL LEAF LANE PALM COAST, FL 32164 |
EC13005145 (Exp: 08/31/2026) | 386-586-0770 |
RICHARD GARY WILSON JR
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
1504 OLD MOODY BLVD BUNNELL, FL 32110 |
UNIT 6 BUNNELL, FL 32110 |
CAC1817645 (Exp: 08/31/2026) | 386-586-6290 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/04/2023 | FINAL APPROVED | AGAETANO |
| ROW - FINAL APRON (AFTER POUR) | 04/03/2023 | FINAL APPROVED | EMADISON |
| ROW - STORMWATER FINAL | 04/03/2023 | FINAL APPROVED | EMADISON |
| U -UTILITY RESIDENTIAL FINAL | 03/22/2023 | FINAL APPROVED | DHANEY |
| U-CROSS CONNECTION | 03/22/2023 | APPROVED | DHANEY |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/16/2023 | APPROVED | PFLANAGAN |
| FINAL SURVEY (OFFICE USE ONLY) | 03/16/2023 | APPROVED | PFLANAGAN |
| ROW- PRE-APRON (PRE-POUR) | 11/30/2022 | APPROVED | EMADISON |
| Note: ** 11/30/22 MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** IN THE EVENT OF RAIN RE-CHECK CULVERT ELEVATION AND COMPACTION | |||
| U - SEWER TIE IN | 10/25/2022 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 10/25/2022 | APPROVED | MGIBSON |
| ELECTRIC - EARLY POWER | 10/19/2022 | APPROVED | RMARTIN |
| WINDOW NAILING | 09/06/2022 | APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2490 Inspector Notes from Inspection 2420 08-31-2022 - All grounds need to be connected – NEC 110.14A. Lanai receptacles grounds not connected. Check at next inspection. Add window/ door nailing for right side and front entry. | |||
| INSULATION | 08/31/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: Inspector Notes from Inspection 2420 08-31-2022 - All grounds need to be connected – NEC 110.14A. Lanai receptacles grounds not connected. Check at next inspection. Add window/ door nailing for right side and front entry. | |||
| ALL ROUGH | 08/25/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: All grounds need to be connected – NEC 110.14A. Lanai receptacles grounds not connected. Add window/ door nailing for right side and front entry. | |||
| LATH/BRICK/ WATER BARRIER | 08/25/2022 | APPROVED | AGAETANO |
| WALL SHEATHING | 06/17/2022 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/17/2022 | APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION SP4'S MISSING IN GARAGE AS PER PLAN, WOOD BEARING WALL, Pg. 6 KING STUD BUILT UP COLUMN (right side in garage) MISSING SP'S TOP & BOTTOM AS PER PLAN. SUBSTITUTE STRAPPING USED FOR INTERIOR BEARING WALL. NO NOTE APPROVING THIS ON APPROVED PLANS. INSPECTION STOPPED...... | |||
| ROOF VALLEY & METAL | 06/14/2022 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/14/2022 | Disapproved - NO FEE | FWILLIS |
| Note: SP4'S MISSING IN GARAGE AS PER PLAN, WOOD BEARING WALL, Pg. 6 KING STUD BUILT UP COLUMN (right side in garage) MISSING SP'S TOP & BOTTOM AS PER PLAN. SUBSTITUTE STRAPPING USED FOR INTERIOR BEARING WALL. NO NOTE APPROVING THIS ON APPROVED PLANS. INSPECTION STOPPED...... | |||
| TIE BEAM / LINTEL | 03/17/2022 | APPROVED | KSANDOE |
| Note: THIS IS A REINSPECTION Please have a full set of approved drawings on site for inspection. | |||
| TIE BEAM / LINTEL | 03/16/2022 | Disapproved - NO FEE | AGAETANO |
| Note: Please have a full set of approved drawings on site for inspection. | |||
| FOUND SURVEY APPROVED (OFFICE) | 03/07/2022 | APPROVED | AMOBLEY |
| MONOLITHIC SLAB | 02/16/2022 | APPROVED | LMILLER |
| MONOLITHIC SLAB | 02/14/2022 | CANCELLED BY APPLICANT | WEB |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/10/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 01/13/2022 | APPROVED | TCHURCHILL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/17/2023 | 03/23/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 11/14/2022 | 11/15/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/03/2022 | 11/03/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/03/2022 | 11/08/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/03/2022 | 11/03/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/07/2022 | 03/07/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/07/2022 | 03/07/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/28/2021 | 12/28/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 12/22/2021 | 02/09/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/22/2021 | 12/22/2021 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM please bring in originals to start the porcess. | |||
| BLD | COMPLETE | 12/22/2021 | 12/22/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/13/2021 | 12/16/2021 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building Residential REVIEW COMMENTS: 1. Roof Zone Nailing shown on sheet 6 does not meet the requirements of the current Code. See Figure R301.2(7) for the current Code requirements. 2. Provide roof ventilation calculations per R806 2020 7th Edition Florida Building Code Residential. | |||
| CUSVC | COMPLETE | 12/13/2021 | 12/16/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 12/13/2021 | 12/13/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/13/2021 | 12/13/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 12/13/2021 | 12/15/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/13/2021 | 12/14/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/13/2021 | 12/17/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/13/2021 | 12/13/2021 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Site Plan: walk way can not encroach in 5 ' easement. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 04/04/2023 |
| CONNECTION FEES | ¤1,077.88 | 01/07/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 01/07/2022 |
| IMPACT FEE FIRE | ¤388.65 | 01/07/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 01/07/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 01/07/2022 |
| RECORDING FEE REIMBURSE DOC | ¤35.50 | 01/07/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 01/07/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 01/07/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 01/07/2022 |
| SURCHARGE FS 533.721 | ¤14.87 | 01/07/2022 |
| SURCHARGE - FS 468.631 | ¤22.31 | 01/07/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 01/07/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 01/07/2022 |
| SW ENG PRE APRON | ¤30.00 | 01/07/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/07/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 01/07/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 01/07/2022 |
| SEWER CREDIT | (¤1,147.00) | 01/07/2022 |
| SEWER INSPECTION | ¤25.00 | 01/07/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 01/07/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 01/07/2022 |
| SITE PLAN 30 | ¤30.00 | 01/07/2022 |
| METER - DEPOSIT | ¤60.00 | 01/07/2022 |
| WATER- TURN ON | ¤25.00 | 01/07/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/07/2022 |
| INSPECTION - RESIDENTIAL | ¤1,083.50 | 01/07/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤306.77 | 01/07/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤17,592.52 |