Permit #2022010470

Permit Details

Status: COED

Parcel Id: 35-11-31-4075-00000-0480
CONDITIONED SPACE: 2567 sqft
GARAGE: 703 sqft
OPENED PORCH (WITH ROOF) : 123 sqft
OPENED PORCH (WITH ROOF) : 349 sqft
Total Square Footage: 3742 sqft
Block: 00000
Subdivision: 2296 - MARINA DEL PALMA SUBDIVISION
Job Phone: 863-647-5815
Location Address: 96 DEL PALMA DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/25/2022
NOC: RECORDED
Applicant name: MARK ALLAN HULBERT
Owner: WHILLANS DONALD A & KARIS M H&W

Address

3445 E ROAD

LOXAHATCHEE, FL 33470

Lot: 0480
Contracted Stated Job Value: ¤44,000.00
Job Description: Single Family Residence
Type: CN

Contractor

HULBERT HOMES INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 6254

LAKELAND, FL 33813

CRC1331304 (Exp: 08/31/2026) 863-647-5815

Sub Contractors

ANTONIO VINCENZO DAHM
Status Location Address State License Number Phone
ACTIVE

10 RYBAR LANE

PALM COAST, FL 32164

CFC1429951 (Exp: 08/31/2026) 386-237-5692
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614
DANIEL FONZI
Status Location Address State License Number Phone
INACTIVE

8500 PARKLINE BLVD SUITE 100

ORLANDO, FL 32809

CCC1331559 (Exp: 08/31/2024) 510-518-5891
JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/07/2022 FINAL APPROVED LMILLER
Note: 12/6/2022 - PREVIOUS INSPECTION NOTES 12-6-22 1. No energy cals on site. 2. Sink in masted bath does not work. 3. Fan in bed room on right side of house does not work. 4. Generator plug not on plan. 12-7-22 notes above resolved
ROW - STORMWATER FINAL 12/07/2022 FINAL APPROVED PFLANAGAN
Note: PASSING AS NOTED THAT THE DUMPSTER IS STILL IN THE VACANT BUT CM HAS NOTES IN THE SYSTEM THAT THEY CALL WASTE PRO TO HAVE IT REMOVED NEED TO HAVE IT REMOVED ASAP ------------------------------------------------------------------------------ 12/6/2022 - PREVIOUS INSPECTION NOTES THINGS THAT NEED TO BE ADDRESSED BEFORE PASSING 1) NEED TO PICK UP ALL TRASH OUT OF THE VACANT LOT TO THE LEFT OF YOURS 2) NEED TO REMOVE THE DUMPSTER OUT OF THE VACANT 3) NEED TO RE-ESTABLISH THE SOD BUFFER ALONG THE ROAD NEED TO BE BAHIA SOD AND NEED TO BE TWO ROWS 4) NEED TO HAAVE TWO ROWS OF BAHIA SOD AT THE END OF THE SIDEWALK.
U -UTILITY RESIDENTIAL FINAL 12/06/2022 FINAL APPROVED JHARDING
ROW - STORMWATER FINAL 12/06/2022 Disapproved -FEE REQUIRED PFLANAGAN
Note: THINGS THAT NEED TO BE ADDRESSED BEFORE PASSING 1) NEED TO PICK UP ALL TRASH OUT OF THE VACANT LOT TO THE LEFT OF YOURS 2) NEED TO REMOVE THE DUMPSTER OUT OF THE VACANT 3) NEED TO RE-ESTABLISH THE SOD BUFFER ALONG THE ROAD NEED TO BE BAHIA SOD AND NEED TO BE TWO ROWS 4) NEED TO HAAVE TWO ROWS OF BAHIA SOD AT THE END OF THE SIDEWALK.
U-CROSS CONNECTION 12/06/2022 APPROVED - AS NOTED JHARDING
Note: No cross connections.
ROW - FINAL APRON (AFTER POUR) 12/06/2022 APPROVED PFLANAGAN
BLD - BUILDING FINAL 12/06/2022 Disapproved - NO FEE BTAYLOR
Note: 12-6-22 1. No energy cals on site. 2. Sink in masted bath does not work. 3. Fan in bed room on right side of house does not work. 4. Generator plug not on plan.
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/05/2022 APPROVED PFLANAGAN
Note: 12/1/2022 - PREVIOUS INSPECTION NOTES 1) THERE IS A LOW AREA ING BACK YARD THE ELEVATION SURROUNDING WON'T ALLOW THE WATER TO FLOW TO DRAINAGE CONVEANCY ON THE PROPERTY LINE 2) BOTH DRAINAGE CONVEANY ON THE PROPERTY LINE NEED TO HAVE POSITIVE FALL TO THE CURB AND GUTTER NEED TO HAVE A MINIMUM OF 0.10 FALL EVERY 20' -------------------------------------------------------------------------------------------------- 11/30/2022 - PREVIOUS INSPECTION NOTES NEED TO RELOAD THE FINAL SURVEY CAN'T READ THE ELEAVTIONS ON THE FINAL SURVEY ITS TO BLURRY TO READ
ROW FIELD SURVEY /GRADING CERTIFICATION 12/05/2022 APPROVED PFLANAGAN
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/01/2022 Disapproved - NO FEE PFLANAGAN
Note: 1) THERE IS A LOW AREA ING BACK YARD THE ELEVATION SURROUNDING WON'T ALLOW THE WATER TO FLOW TO DRAINAGE CONVEANCY ON THE PROPERTY LINE 2) BOTH DRAINAGE CONVEANY ON THE PROPERTY LINE NEED TO HAVE POSITIVE FALL TO THE CURB AND GUTTER NEED TO HAVE A MINIMUM OF 0.10 FALL EVERY 20' -------------------------------------------------------------------------------------------------- 11/30/2022 - PREVIOUS INSPECTION NOTES NEED TO RELOAD THE FINAL SURVEY CAN'T READ THE ELEAVTIONS ON THE FINAL SURVEY ITS TO BLURRY TO READ
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/30/2022 Disapproved - NO FEE PFLANAGAN
Note: NEED TO RELOAD THE FINAL SURVEY CAN'T READ THE ELEAVTIONS ON THE FINAL SURVEY ITS TO BLURRY TO READ
WINDOW NAILING 11/16/2022 APPROVED DCUSHING
Note: THIS IS A REINSPECTION New inspection due to canceled inspection Inspector Notes from Inspection 2490 Inspector Notes from Inspection 2420 THIS IS A REINSPECTION 1. NEED TO PHASE OUT HOT CONDUCTORS IN PANEL BOX. NEC.210.5(C).. 2. FIREBLOCKING AT SOFFITS AND DROP CEILINGS…FBC 718.2.3 (fire place area) 3. FIREBLOCKING MATERIALS R302.11.1 (1-8) (thickness og fireblocking at range hood wall soffit does not meet minimum) 4. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 5. need to connect electric to shower/bath exhaust in guest bath 6. need nail plate at nailer area foe soffit at range hood. 7. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 (low voltage) 8. need all exterior swing doors installed and inspected (can be moved to insulation inspection if other notes are resolved but will need to add notes to insulation inspection WINDOW NAILING INSP. ADDED FOR EXTERIOR SWING DOORS ONLY 8-18-22 1. Front door not screwed off
ROW- PRE-APRON (PRE-POUR) 10/18/2022 APPROVED PFLANAGAN
Note: READY FOR PAVERS 10/14/2022 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS NOT READY NEED TO HAVE ALL PAVER BASE DOWN AND COMPACTED BEFORE THIS INSPECTION --------------------------------------------------------------------------------- 10/5/2022 - PREVIOUS INSPECTION NOTES READY TO POUR PAVER RESTRAINTS, SIDEWALK AND THE APRON BEFORE THE NEXT PRE POUR INSPECTION ALL PAVER BASE NEEDS TO BE DOWN AND COMPACTED WITH NO PAVERS IF THERE ARE PAVERS DOWN WILL MAKE YOU PULL THEM SO WE CAN INSPECT THE BASE
ROW- PRE-APRON (PRE-POUR) 10/17/2022 CANCELLED BY APPLICANT WEB
Note: 10/14/2022 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS NOT READY NEED TO HAVE ALL PAVER BASE DOWN AND COMPACTED BEFORE THIS INSPECTION --------------------------------------------------------------------------------- 10/5/2022 - PREVIOUS INSPECTION NOTES READY TO POUR PAVER RESTRAINTS, SIDEWALK AND THE APRON BEFORE THE NEXT PRE POUR INSPECTION ALL PAVER BASE NEEDS TO BE DOWN AND COMPACTED WITH NO PAVERS IF THERE ARE PAVERS DOWN WILL MAKE YOU PULL THEM SO WE CAN INSPECT THE BASE
ROW- PRE-APRON (PRE-POUR) 10/14/2022 Disapproved -FEE REQUIRED PFLANAGAN
Note: THIS INSPECTION IS NOT READY NEED TO HAVE ALL PAVER BASE DOWN AND COMPACTED BEFORE THIS INSPECTION --------------------------------------------------------------------------------- 10/5/2022 - PREVIOUS INSPECTION NOTES READY TO POUR PAVER RESTRAINTS, SIDEWALK AND THE APRON BEFORE THE NEXT PRE POUR INSPECTION ALL PAVER BASE NEEDS TO BE DOWN AND COMPACTED WITH NO PAVERS IF THERE ARE PAVERS DOWN WILL MAKE YOU PULL THEM SO WE CAN INSPECT THE BASE
ROW- PRE-APRON (PRE-POUR) 10/05/2022 PARTIALLY APPROVED PFLANAGAN
Note: READY TO POUR PAVER RESTRAINTS, SIDEWALK AND THE APRON BEFORE THE NEXT PRE POUR INSPECTION ALL PAVER BASE NEEDS TO BE DOWN AND COMPACTED WITH NO PAVERS IF THERE ARE PAVERS DOWN WILL MAKE YOU PULL THEM SO WE CAN INSPECT THE BASE
ELECTRIC - EARLY POWER 09/20/2022 APPROVED - AS NOTED LMILLER
Note: FPL notified at 10:51
GRAVITY SEWER TEST 09/06/2022 APPROVED MGIBSON
Note: THIS IS A REINSPECTION HOUSE HAS EXCEEDED 100' OF SEWER PIPE ANOTHER C/O IS REQUIRED
GRAVITY SEWER TEST 09/01/2022 Disapproved -FEE REQUIRED MGIBSON
Note: HOUSE HAS EXCEEDED 100' OF SEWER PIPE ANOTHER C/O IS REQUIRED
U - SEWER TIE IN 09/01/2022 APPROVED MGIBSON
LATH/BRICK/ WATER BARRIER 08/18/2022 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2490 Inspector Notes from Inspection 2420 THIS IS A REINSPECTION 1. NEED TO PHASE OUT HOT CONDUCTORS IN PANEL BOX. NEC.210.5(C).. 2. FIREBLOCKING AT SOFFITS AND DROP CEILINGS…FBC 718.2.3 (fire place area) 3. FIREBLOCKING MATERIALS R302.11.1 (1-8) (thickness og fireblocking at range hood wall soffit does not meet minimum) 4. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 5. need to connect electric to shower/bath exhaust in guest bath 6. need nail plate at nailer area foe soffit at range hood. 7. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 (low voltage) 8. need all exterior swing doors installed and inspected (can be moved to insulation inspection if other notes are resolved but will need to add notes to insulation inspection WINDOW NAILING INSP. ADDED FOR EXTERIOR SWING DOORS ONLY
WINDOW NAILING 08/18/2022 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2490 Inspector Notes from Inspection 2420 THIS IS A REINSPECTION 1. NEED TO PHASE OUT HOT CONDUCTORS IN PANEL BOX. NEC.210.5(C).. 2. FIREBLOCKING AT SOFFITS AND DROP CEILINGS…FBC 718.2.3 (fire place area) 3. FIREBLOCKING MATERIALS R302.11.1 (1-8) (thickness og fireblocking at range hood wall soffit does not meet minimum) 4. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 5. need to connect electric to shower/bath exhaust in guest bath 6. need nail plate at nailer area foe soffit at range hood. 7. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 (low voltage) 8. need all exterior swing doors installed and inspected (can be moved to insulation inspection if other notes are resolved but will need to add notes to insulation inspection WINDOW NAILING INSP. ADDED FOR EXTERIOR SWING DOORS ONLY
WINDOW NAILING 08/18/2022 Disapproved - NO FEE BTAYLOR
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2490 Inspector Notes from Inspection 2420 THIS IS A REINSPECTION 1. NEED TO PHASE OUT HOT CONDUCTORS IN PANEL BOX. NEC.210.5(C).. 2. FIREBLOCKING AT SOFFITS AND DROP CEILINGS…FBC 718.2.3 (fire place area) 3. FIREBLOCKING MATERIALS R302.11.1 (1-8) (thickness og fireblocking at range hood wall soffit does not meet minimum) 4. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 5. need to connect electric to shower/bath exhaust in guest bath 6. need nail plate at nailer area foe soffit at range hood. 7. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 (low voltage) 8. need all exterior swing doors installed and inspected (can be moved to insulation inspection if other notes are resolved but will need to add notes to insulation inspection WINDOW NAILING INSP. ADDED FOR EXTERIOR SWING DOORS ONLY 8-18-22 1. Front door not screwed off
INSULATION 07/25/2022 APPROVED - AS NOTED DCUSHING
Note: Inspector Notes from Inspection 2420 THIS IS A REINSPECTION 1. NEED TO PHASE OUT HOT CONDUCTORS IN PANEL BOX. NEC.210.5(C).. 2. FIREBLOCKING AT SOFFITS AND DROP CEILINGS…FBC 718.2.3 (fire place area) 3. FIREBLOCKING MATERIALS R302.11.1 (1-8) (thickness og fireblocking at range hood wall soffit does not meet minimum) 4. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 5. need to connect electric to shower/bath exhaust in guest bath 6. need nail plate at nailer area foe soffit at range hood. 7. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 (low voltage) 8. need all exterior swing doors installed and inspected (can be moved to insulation inspection if other notes are resolved but will need to add notes to insulation inspection WINDOW NAILING INSP. ADDED FOR EXTERIOR SWING DOORS ONLY
ALL ROUGH 07/21/2022 APPROVED - AS NOTED DCUSHING
Note: THIS IS A REINSPECTION 1. NEED TO PHASE OUT HOT CONDUCTORS IN PANEL BOX. NEC.210.5(C).. 2. FIREBLOCKING AT SOFFITS AND DROP CEILINGS…FBC 718.2.3 (fire place area) 3. FIREBLOCKING MATERIALS R302.11.1 (1-8) (thickness og fireblocking at range hood wall soffit does not meet minimum) 4. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 5. need to connect electric to shower/bath exhaust in guest bath 6. need nail plate at nailer area foe soffit at range hood. 7. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 (low voltage) 8. need all exterior swing doors installed and inspected (can be moved to insulation inspection if other notes are resolved but will need to add notes to insulation inspection
ALL ROUGH 07/19/2022 CANCELLED BY APPLICANT WEB
ALL ROUGH 07/19/2022 Disapproved -FEE REQUIRED LMILLER
Note: 1. NEED TO PHASE OUT HOT CONDUCTORS IN PANEL BOX. NEC.210.5(C).. 2. FIREBLOCKING AT SOFFITS AND DROP CEILINGS…FBC 718.2.3 (fire place area) 3. FIREBLOCKING MATERIALS R302.11.1 (1-8) (thickness og fireblocking at range hood wall soffit does not meet minimum) 4. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 5. need to connect electric to shower/bath exhaust in guest bath 6. need nail plate at nailer area foe soffit at range hood. 7. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 (low voltage) 8. need all exterior swing doors installed and inspected (can be moved to insulation inspection if other notes are resolved but will need to add notes to insulation inspection
ELECTRIC-TUG 06/07/2022 APPROVED - AS NOTED RMARTIN
Note: emailed fpl released power 10:00
ROOF VALLEY & METAL 06/02/2022 APPROVED DCUSHING
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/02/2022 APPROVED DCUSHING
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Please provide a full set of Approved drawings and engineering packet on site for inspection. Neither on site. 5/25/22 need two straps on BO1 double truss
WALL SHEATHING 05/25/2022 APPROVED RMARTIN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/25/2022 Disapproved - NO FEE RMARTIN
Note: THIS IS A REINSPECTION Please provide a full set of Approved drawings and engineering packet on site for inspection. Neither on site. 5/25/22 need two straps on BO1 double truss
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/20/2022 Disapproved - NO FEE AGAETANO
Note: Please provide a full set of Approved drawings and engineering packet on site for inspection. Neither on site.
ROOF SHEATHING 05/17/2022 APPROVED LMILLER
FOUND SURVEY APPROVED (OFFICE) 05/13/2022 APPROVED TBAKER
TIE BEAM / LINTEL 04/12/2022 APPROVED RMARTIN
MONOLITHIC SLAB 03/15/2022 APPROVED AGAETANO
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1. COMPACTION AND TERMITE TREATMENT NOTIFICATION NOT IN BOX 2. 12 inch MINIMUM DEPTH , UNDISTURBED GROUND SURFACE… R403.1.3.4 and in accordance with R401.2, and R403.1 ALL FOOTINGS SHALL BE PLACED AT LEAST 12 in. BELOW THE UNDISTURBED GROUND SURFACE 3. Notes on foundation plan indicate exterior footings are to be per typical wall detail (detail shows 3 bars in footings but there are no notes indicating how many bars to use, so we need clarification), (there are only two bars in footings)
WATER METER INSTALLATION REQUEST 03/15/2022 APPROVED CSTONE
MONOLITHIC SLAB 03/11/2022 CANCELLED BY APPLICANT LMILLER
Note: THIS IS A REINSPECTION 1. COMPACTION AND TERMITE TREATMENT NOTIFICATION NOT IN BOX 2. 12 inch MINIMUM DEPTH , UNDISTURBED GROUND SURFACE… R403.1.3.4 and in accordance with R401.2, and R403.1 ALL FOOTINGS SHALL BE PLACED AT LEAST 12 in. BELOW THE UNDISTURBED GROUND SURFACE 3. Notes on foundation plan indicate exterior footings are to be per typical wall detail (detail shows 3 bars in footings but there are no notes indicating how many bars to use, so we need clarification), (there are only two bars in footings)
MONOLITHIC SLAB 03/04/2022 Disapproved -FEE REQUIRED LMILLER
Note: 1. COMPACTION AND TERMITE TREATMENT NOTIFICATION NOT IN BOX 2. 12 inch MINIMUM DEPTH , UNDISTURBED GROUND SURFACE… R403.1.3.4 and in accordance with R401.2, and R403.1 ALL FOOTINGS SHALL BE PLACED AT LEAST 12 in. BELOW THE UNDISTURBED GROUND SURFACE 3. Notes on foundation plan indicate exterior footings are to be per typical wall detail (detail shows 3 bars in footings but there are no notes indicating how many bars to use, so we need clarification), (there are only two bars in footings)
MONOLITHIC SLAB 02/18/2022 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 02/03/2022 APPROVED MGIBSON

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 05/13/2022 05/13/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/13/2022 05/13/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 03/09/2022 03/10/2022
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
MECH COMPLETE 01/19/2022 01/19/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 01/19/2022 01/20/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD HOLD 01/11/2022 01/12/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS: 1. Provide product approval for address of proposed construction. Submitted is for 26 Rio Vista Dr. Per F.S. 471.025 and F.A.C. 61 G15-23.005.
CUSVC COMPLETE 01/11/2022 01/18/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 01/11/2022 01/12/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/11/2022 01/11/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 01/11/2022 01/12/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 01/11/2022 01/12/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Orientation of Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2020 7Th Edition
SW1 COMPLETE 01/11/2022 01/19/2022
Note: Released By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM
ZON COMPLETE 01/11/2022 01/12/2022
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/07/2022
REINSPECTION RESIDENTIAL ¤40.00 12/07/2022
REINSPECTION RESIDENTIAL ¤40.00 12/07/2022
SW ENG REINSPECTION 20 ¤20.00 12/07/2022
SW ENG REINSPECTION 30 ¤30.00 12/07/2022
SW ENG - REVIEW 20 ¤20.00 01/25/2022
SW ENG RES REVIEW 200 ¤200.00 01/25/2022
3% TRANS IMPACT FEE CREDIT (¤96.72) 01/25/2022
SEWER INSPECTION ¤25.00 01/25/2022
SEWER CAPITAL FACILITY ¤2,607.06 01/25/2022
WATER CAPITAL FACILITY FEE ¤2,436.75 01/25/2022
SITE PLAN 30 ¤30.00 01/25/2022
CONNECTION FEES ¤25.00 01/25/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 01/25/2022
IMPACT FEE FIRE ¤388.65 01/25/2022
IMPACT FEE PARKS ¤1,455.13 01/25/2022
IMPACT FEE SCHOOL ¤3,600.00 01/25/2022
IMPACT FEE TRANSPORTATION ¤3,224.00 01/25/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 01/25/2022
SURCHARGE FS 533.721 ¤12.67 01/25/2022
SURCHARGE - FS 468.631 ¤19.01 01/25/2022
SW ENG - FOUNDATION SURVEY ¤20.00 01/25/2022
SW ENG INSPECTION 80 ¤80.00 01/25/2022
SW ENG PRE APRON ¤30.00 01/25/2022
METER - DEPOSIT ¤60.00 01/25/2022
WATER-METER ¤467.09 01/25/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/25/2022
INSPECTION - RESIDENTIAL ¤915.75 01/25/2022
PLAN REVIEW - RESIDENTIAL ¤259.74 01/25/2022
Fees Total Due: ¤0.00 Total Paid: ¤15,923.82