Permit #2022010763

Permit Details

Status: COED

Parcel Id: 07-11-31-7063-00190-0130
CONDITIONED SPACE: 3154 sqft
GARAGE: 578 sqft
OPENED PORCH (WITH ROOF) : 78 sqft
OPENED PORCH (WITH ROOF) : 216 sqft
OPENED PORCH (WITH ROOF) : 39 sqft
Total Square Footage: 4065 sqft
Block: 00190
Subdivision: 2174 - SECTION 63-ZEBULAHS TRAIL
Job Phone: (386) 246-6123
Location Address: 5 ZITHER CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/25/2022
NOC: RECORDED
Applicant name: BRIAN ANDREW GAZZOLI
Owner: SEAGATE HOMES LLC

Address

185 CYPRESS POINT PKWY

PALM COAST, FL 32164

Address

STE 7

PALM COAST, FL 32164

Lot: 0130
Contracted Stated Job Value: ¤332,709.00
Job Description: SINGLE FAMIYL RESIDENCE
Type: CN

Contractor

SEAGATE HOMES, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

185 CYPRESS POINT PARKWAY

Palm Coast, FL 32137

SUITE 7

Palm Coast, FL 32137

CGC1518372 (Exp: 08/31/2026) 386-246-6132

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
CHAD DAVID GRESSANI
Status Location Address State License Number Phone Fax
ACTIVE

2640 BROOKSHIRE CIRCLE

MELBOURNE, FL 32904

CCC1327235 (Exp: 08/31/2026) 321-288-6415 321-729-8997
TERRY HILE BURD
Status Location Address State License Number Phone Fax
INACTIVE

PO Box 180308

CASSELBERRY, FL 32707

CAC1814423 (Exp: 08/31/2024) (407) 831-3600 (407)831-2893

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/19/2023 FINAL APPROVED RSIMS
Note: 5/17/2023 - PREVIOUS INSPECTION NOTES 5/17/23: House is locked up tight and no key on site. 5/16/2023 - PREVIOUS INSPECTION NOTES 5/16/23: 1). 2nd floor right front bedroom smoke detector is not working properly. (& not interconnected). 2). Oven anti-tip device is not anchored securely. (need 2 anchors into bottom plate).
BLD - BUILDING FINAL 05/17/2023 Disapproved - NO FEE RSIMS
Note: 5/17/23: House is locked up tight and no key on site. 5/16/2023 - PREVIOUS INSPECTION NOTES 5/16/23: 1). 2nd floor right front bedroom smoke detector is not working properly. (& not interconnected). 2). Oven anti-tip device is not anchored securely. (need 2 anchors into bottom plate).
BLD - BUILDING FINAL 05/16/2023 Disapproved - NO FEE RSIMS
Note: 5/16/23: 1). 2nd floor right front bedroom smoke detector is not working properly. (& not interconnected). 2). Oven anti-tip device is not anchored securely. (need 2 anchors into bottom plate).
ROW - FINAL APRON (AFTER POUR) 04/28/2023 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
ROW - STORMWATER FINAL 04/28/2023 APPROVED GBERTOLA
Note: CORRECTION WERE MADE AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
U -UTILITY RESIDENTIAL FINAL 04/26/2023 FINAL APPROVED JHARDING
U-CROSS CONNECTION 04/26/2023 APPROVED - AS NOTED JHARDING
Note: No cross connections.
ROW FIELD SURVEY /GRADING CERTIFICATION 04/14/2023 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
FINAL SURVEY (OFFICE USE ONLY) 04/14/2023 APPROVED GBERTOLA
ROW- PRE-APRON (PRE-POUR) 03/08/2023 APPROVED EMADISON
Note: ** 03/08/23 READY TO POUR IN THE EVENT OF RAIN RECHECK CULVERT AND COMPACTION ** MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ELECTRIC - EARLY POWER 03/07/2023 APPROVED RSIMS
Note: 3/7/23: Front door was wide open with a fresh paint lid lying outside of the door & what appeared to be freshly painted doors inside. 3/3/2023 - PREVIOUS INSPECTION NOTES 3/3/23: Range feed now has a damaged insulating jacket inside the wall above the lath. Once repaired it will also need a nail plate to protect from damage during drywall repair. 2/28/2023 - PREVIOUS INSPECTION NOTES 2/28/23: 1). Individual unsheathed conductors are outside of the Range outlet. Need to be fully into box or covered with conduit/sealtite.
ELECTRIC - EARLY POWER 03/03/2023 Disapproved -FEE REQUIRED RSIMS
Note: 3/3/23: Range feed now has a damaged insulating jacket inside the wall above the lath. Once repaired it will also need a nail plate to protect from damage during drywall repair. 2/28/2023 - PREVIOUS INSPECTION NOTES 2/28/23: 1). Individual unsheathed conductors are outside of the Range outlet. Need to be fully into box or covered with conduit/sealtite.
ELECTRIC - EARLY POWER 02/28/2023 Disapproved - NO FEE RSIMS
Note: 2/28/23: 1). Individual unsheathed conductors are outside of the Range outlet. Need to be fully into box or covered with conduit/sealtite.
GRAVITY SEWER TEST 02/10/2023 APPROVED RSIMS
U - SEWER TIE IN 02/10/2023 APPROVED RSIMS
PEP TANK INSTALLATION REQUEST 01/06/2023 APPROVED CSTONE
INSULATION 12/01/2022 APPROVED BTAYLOR
Note: 11/30/2022 - PREVIOUS INSPECTION NOTES 11/30/22 1. Garage wall insulation falling out 2. Large hole in upstairs floor decking must be sealed under tub 11/29/2022 - PREVIOUS INSPECTION NOTES 11-29-22 Workers just arrived.
INSULATION 11/30/2022 Disapproved -FEE REQUIRED MKRASKI
Note: 11/30/22 1. Garage wall insulation falling out 2. Large hole in upstairs floor decking must be sealed under tub 11/29/2022 - PREVIOUS INSPECTION NOTES 11-29-22 Workers just arrived.
INSULATION 11/29/2022 Disapproved - NO FEE BTAYLOR
Note: 11-29-22 Workers just arrived.
LATH/BRICK/ WATER BARRIER 11/29/2022 APPROVED BTAYLOR
ALL ROUGH 11/15/2022 APPROVED BTAYLOR
WINDOW NAILING 11/15/2022 APPROVED BTAYLOR
Note: 11/3/2022 - PREVIOUS INSPECTION NOTES 11/3/2022: 1). 1st floor windows not installed per manufacturer's instructions. (Installation instructions not included with plans. / Looked up online as instructed on window sticker.) * 2nd floor flanged windows - Approved 11/1/2022 - PREVIOUS INSPECTION NOTES 11/1/2022: INSPECTION STOPPED. 1). No documents (installation instructions) in permit box. 2). Window trim (screw covers) still in place. Need to be removed for inspection. 3). broken inside window pane - 1st floor * R 107.3,1. Approved Documents need to be on site for inspection.
WINDOW NAILING 11/03/2022 Disapproved -FEE REQUIRED RSIMS
Note: 11/3/2022: 1). 1st floor windows not installed per manufacturer's instructions. (Installation instructions not included with plans. / Looked up online as instructed on window sticker.) (Please include installation instructions with plans or FPA sheet). * 2nd floor flanged windows - Approved 11/1/2022 - PREVIOUS INSPECTION NOTES 11/1/2022: INSPECTION STOPPED. 1). No documents (installation instructions) in permit box. 2). Window trim (screw covers) still in place. Need to be removed for inspection. 3). broken inside window pane - 1st floor * R 107.3,1. Approved Documents need to be on site for inspection.
WINDOW NAILING 11/01/2022 Disapproved - NO FEE RSIMS
Note: 11/1/2022: INSPECTION STOPPED. 1). No documents (installation instructions) in permit box. 2). Window trim (screw covers) still in place. Need to be removed for inspection. 3). broken inside window pane - 1st floor * R 107.3,1. Approved Documents need to be on site for inspection.
ROOF VALLEY & METAL 10/06/2022 APPROVED RSIMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/22/2022 APPROVED TSTAUFFACHER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION New inspection due to canceled inspection THIS IS A REINSPECTION THIS IS A REINSPECTION 6/29/22 F13 and the F-12 missing strapping per plan meta 18 are to be 24" o.c. Floor trusses to bearing wall connection are missing all HTS20 detail page 6.1 All bearing wall missing SP4 bottom and top. Mid way blocking not installed.Missing CS20 at headers. Missing all truss connectors. See detail Page 9.1 bearing wall. 2nd floor Header opening missing all MSTA anchors at the floor. also at the jack post 4 corners. Rods have not been installed at wall above LVL beam below please provide detail on beam to wall above connection. Due to multiple missing anchors THIS INSPECTION HAS BEEN STOPPED. Roof sheating was bumped checked and passed. Prints have been highlighted to assists contractor. 07/15/2022: Load bearing walls still missing SP4 and mid wall blocking per plans 7/19/22 LOAD BEARING WALLS STILL MISSING SP4 HIGHLIGHTED ON PLAN DO NOT RE-SCHEDULE UNTIL WORK IS DONE AND YOU WALK JOB TO VERIFY WORK IS DONE 2-20-22 note above not resolved 2-21-22 note above not resolved
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/21/2022 Disapproved - NO FEE LMILLER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION New inspection due to canceled inspection THIS IS A REINSPECTION THIS IS A REINSPECTION 6/29/22 F13 and the F-12 missing strapping per plan meta 18 are to be 24" o.c. Floor trusses to bearing wall connection are missing all HTS20 detail page 6.1 All bearing wall missing SP4 bottom and top. Mid way blocking not installed.Missing CS20 at headers. Missing all truss connectors. See detail Page 9.1 bearing wall. 2nd floor Header opening missing all MSTA anchors at the floor. also at the jack post 4 corners. Rods have not been installed at wall above LVL beam below please provide detail on beam to wall above connection. Due to multiple missing anchors THIS INSPECTION HAS BEEN STOPPED. Roof sheating was bumped checked and passed. Prints have been highlighted to assists contractor. 07/15/2022: Load bearing walls still missing SP4 and mid wall blocking per plans 7/19/22 LOAD BEARING WALLS STILL MISSING SP4 HIGHLIGHTED ON PLAN DO NOT RE-SCHEDULE UNTIL WORK IS DONE AND YOU WALK JOB TO VERIFY WORK IS DONE 2-20-22 note above not resolved 2-21-22 note above not resolved
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/20/2022 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION New inspection due to canceled inspection THIS IS A REINSPECTION THIS IS A REINSPECTION 6/29/22 F13 and the F-12 missing strapping per plan meta 18 are to be 24" o.c. Floor trusses to bearing wall connection are missing all HTS20 detail page 6.1 All bearing wall missing SP4 bottom and top. Mid way blocking not installed.Missing CS20 at headers. Missing all truss connectors. See detail Page 9.1 bearing wall. 2nd floor Header opening missing all MSTA anchors at the floor. also at the jack post 4 corners. Rods have not been installed at wall above LVL beam below please provide detail on beam to wall above connection. Due to multiple missing anchors THIS INSPECTION HAS BEEN STOPPED. Roof sheating was bumped checked and passed. Prints have been highlighted to assists contractor. 07/15/2022: Load bearing walls still missing SP4 and mid wall blocking per plans 7/19/22 LOAD BEARING WALLS STILL MISSING SP4 HIGHLIGHTED ON PLAN DO NOT RE-SCHEDULE UNTIL WORK IS DONE AND YOU WALK JOB TO VERIFY WORK IS DONE 2-20-22 note above not resolved
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/19/2022 Disapproved - NO FEE RMARTIN
Note: New inspection due to canceled inspection THIS IS A REINSPECTION THIS IS A REINSPECTION 6/29/22 F13 and the F-12 missing strapping per plan meta 18 are to be 24" o.c. Floor trusses to bearing wall connection are missing all HTS20 detail page 6.1 All bearing wall missing SP4 bottom and top. Mid way blocking not installed.Missing CS20 at headers. Missing all truss connectors. See detail Page 9.1 bearing wall. 2nd floor Header opening missing all MSTA anchors at the floor. also at the jack post 4 corners. Rods have not been installed at wall above LVL beam below please provide detail on beam to wall above connection. Due to multiple missing anchors THIS INSPECTION HAS BEEN STOPPED. Roof sheating was bumped checked and passed. Prints have been highlighted to assists contractor. 07/15/2022: Load bearing walls still missing SP4 and mid wall blocking per plans 7/19/22 LOAD BEARING WALLS STILL MISSING SP4 HIGHLIGHTED ON PLAN DO NOT RE-SCHEDULE UNTIL WORK IS DONE AND YOU WALK JOB TO VERIFY WORK IS DONE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/18/2022 CANCELLED BY APPLICANT WEB
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 6/29/22 F13 and the F-12 missing strapping per plan meta 18 are to be 24" o.c. Floor trusses to bearing wall connection are missing all HTS20 detail page 6.1 All bearing wall missing SP4 bottom and top. Mid way blocking not installed.Missing CS20 at headers. Missing all truss connectors. See detail Page 9.1 bearing wall. 2nd floor Header opening missing all MSTA anchors at the floor. also at the jack post 4 corners. Rods have not been installed at wall above LVL beam below please provide detail on beam to wall above connection. Due to multiple missing anchors THIS INSPECTION HAS BEEN STOPPED. Roof sheating was bumped checked and passed. Prints have been highlighted to assists contractor. 07/15/2022: Load bearing walls still missing SP4 and mid wall blocking per plans
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/15/2022 Disapproved - NO FEE TSTAUFFACHER
Note: THIS IS A REINSPECTION 6/29/22 F13 and the F-12 missing strapping per plan meta 18 are to be 24" o.c. Floor trusses to bearing wall connection are missing all HTS20 detail page 6.1 All bearing wall missing SP4 bottom and top. Mid way blocking not installed.Missing CS20 at headers. Missing all truss connectors. See detail Page 9.1 bearing wall. 2nd floor Header opening missing all MSTA anchors at the floor. also at the jack post 4 corners. Rods have not been installed at wall above LVL beam below please provide detail on beam to wall above connection. Due to multiple missing anchors THIS INSPECTION HAS BEEN STOPPED. Roof sheating was bumped checked and passed. Prints have been highlighted to assists contractor. 07/15/2022: Load bearing walls still missing SP4 and mid wall blocking per plans
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/29/2022 Disapproved -FEE REQUIRED JWALKER
Note: 6/29/22 F13 and the F-12 missing strapping per plan meta 18 are to be 24" o.c. Floor trusses to bearing wall connection are missing all HTS20 detail page 6.1 All bearing wall missing SP4 bottom and top. Mid way blocking not installed.Missing CS20 at headers. Missing all truss connectors. See detail Page 9.1 bearing wall. 2nd floor Header opening missing all MSTA anchors at the floor. also at the jack post 4 corners. Rods have not been installed at wall above LVL beam below please provide detail on beam to wall above connection. Due to multiple missing anchors THIS INSPECTION HAS BEEN STOPPED. Roof sheating was bumped checked and passed. Prints have been highlighted to assists contractor.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/24/2022 Disapproved -FEE REQUIRED DCUSHING
Note: THIS IS A REINSPECTION Missing anchor bolts at bearing wall at stairs Missing SP4s at base of header at bottom of stairs Loose threaded rod Cannot verify strapping at LVL on right side F13 missing strapping per plans INSPECTION STOPPED/VERIFY DETAILS PRIOR TO CALLING IN FOR INSPECTION Some items addressed, anchor bolt nuts are only hand tight, check all
WALL SHEATHING 06/16/2022 APPROVED TSTAUFFACHER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/16/2022 Disapproved - NO FEE TSTAUFFACHER
Note: Missing anchor bolts at bearing wall at stairs Missing SP4s at base of header at bottom of stairs Loose threaded rod Cannot verify strapping at LVL on right side F13 missing strapping per plans INSPECTION STOPPED/VERIFY DETAILS PRIOR TO CALLING IN FOR INSPECTION
TIE BEAM / LINTEL 05/11/2022 APPROVED TSTAUFFACHER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Several down rods too short to meet 25" min. lap, not visible @ 2nd course of cmu above slab, check allL 05/10/2022: Added bar left of front door in wrong cell and not tied Back right side/additional bar added not tied
TIE BEAM / LINTEL 05/10/2022 Disapproved - NO FEE TSTAUFFACHER
Note: THIS IS A REINSPECTION Several down rods too short to meet 25" min. lap, not visible @ 2nd course of cmu above slab, check allL 05/10/2022: Added bar left of front door in wrong cell and not tied Back right side/additional bar added not tied
TIE BEAM / LINTEL 05/03/2022 Disapproved - NO FEE DCUSHING
Note: Several down rods too short to meet 25" min. lap, not visible @ 2nd course of cmu above slab, check all
FOUND SURVEY APPROVED (OFFICE) 04/25/2022 APPROVED TBAKER
MONOLITHIC SLAB 04/07/2022 APPROVED TSTAUFFACHER
PLUMBING 1ST ROUGH UNDERGROUND 04/05/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 02/10/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 02/10/2023 02/10/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 08/01/2022 08/02/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 07/07/2022 07/08/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON COMPLETE 04/25/2022 04/25/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/25/2022 04/25/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SWALE COMPLETE 01/19/2022 03/14/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 01/18/2022 01/19/2022
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
CUSVC COMPLETE 01/18/2022 01/24/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 01/18/2022 01/19/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/18/2022 01/19/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 01/18/2022 01/21/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 01/18/2022 01/19/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 01/18/2022 01/24/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 01/18/2022 01/20/2022
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 05/19/2023
PLAN REVIEW - REVISION ¤32.50 05/19/2023
PLAN REVIEW - REVISION ¤32.50 05/19/2023
PLAN REVIEW - REVISION ¤32.50 05/19/2023
REINSPECTION RESIDENTIAL ¤40.00 05/19/2023
REINSPECTION RESIDENTIAL ¤40.00 05/19/2023
REINSPECTION RESIDENTIAL ¤40.00 05/19/2023
REINSPECTION RESIDENTIAL ¤40.00 05/19/2023
REINSPECTION RESIDENTIAL ¤40.00 05/19/2023
REINSPECTION RESIDENTIAL ¤40.00 05/19/2023
CONNECTION FEES ¤1,077.88 01/25/2022
METER - DEPOSIT ¤60.00 01/25/2022
WATER- TURN ON ¤25.00 01/25/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/25/2022
INSPECTION - RESIDENTIAL ¤1,064.25 01/25/2022
PLAN REVIEW - RESIDENTIAL ¤301.86 01/25/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 01/25/2022
IMPACT FEE FIRE ¤388.65 01/25/2022
IMPACT FEE PARKS ¤1,455.13 01/25/2022
IMPACT FEE SCHOOL ¤3,600.00 01/25/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 01/25/2022
WATER -IRRIGATION INSPECTION ¤25.00 01/25/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 01/25/2022
SURCHARGE FS 533.721 ¤14.63 01/25/2022
SURCHARGE - FS 468.631 ¤21.94 01/25/2022
SW ENG - FOUNDATION SURVEY ¤20.00 01/25/2022
SW ENG INSPECTION 80 ¤80.00 01/25/2022
SW ENG PRE APRON ¤30.00 01/25/2022
SW ENG - REVIEW 20 ¤20.00 01/25/2022
SW ENG RES REVIEW 200 ¤200.00 01/25/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 01/25/2022
SEWER CREDIT (¤1,147.00) 01/25/2022
SEWER INSPECTION ¤25.00 01/25/2022
SEWER CAPITAL FACILITY ¤4,939.76 01/25/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 01/25/2022
SITE PLAN 30 ¤30.00 01/25/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,921.87