I want to search for...

Permit #2022010887

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-00210-0060
CONDITIONED SPACE: 2704 sqft
OPENED PORCH (WITH ROOF) : 226 sqft
OPENED PORCH (WITH ROOF) : 68 sqft
GARAGE: 896 sqft
Total Square Footage: 3894 sqft
Block: 00210
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: 386-931-5395
Location Address: 104 LYNBROOK DR
Type: DU - DUPLEX
Issue Date: 01/28/2022
NOC: RECORDED
Applicant name: RYAN JAMES PERRY
Owner: MONKEVITCH EUGENII

Address

46 NORTH PARK CIRCLE

PALM COAST, FL 32137

Lot: 0060
Contracted Stated Job Value: ¤300,000.00
Job Description: DUPLEX
Type: CN

Contractor

WATERSIDE HOMES RENOVATIONS AND DESIGNS INC
Status Location Address State License Number Phone
ACTIVE

10 BISCAYNE DRIVE

PALM COAST, FL 32137

CBC1263021 (Exp: 08/31/2026) 386-931-5395

Sub Contractors

HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
RYAN JAMES PERRY
Status Location Address State License Number Phone
ACTIVE

10 BISCAYNE DRIVE

PALM COAST, FL 32137

CBC1263021 (Exp: 08/31/2026) 386-931-5395
PETER JOSEPH LYDEN
Status Location Address State License Number Phone
CANCEL

17 UNIMAY CT

BUNNELL, FL 32110

EC0002436 (Exp: 08/31/2022) 386-931-2568
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

PO BOX 912

PALM COAST, FL 32164

CAC1820539 (Exp: 08/31/2026) 386-264-0550
DILLON CARRERAS
Status Location Address State License Number
ACTIVE

3504 LUNDY ROAD

PALATKA, FL 32177

EC13010133 (Exp: 08/31/2026)

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 04/25/2023 FINAL APPROVED DHANEY
ROW - FINAL APRON (AFTER POUR) 02/10/2023 APPROVED PFLANAGAN
BLD - BUILDING FINAL 02/10/2023 FINAL APPROVED RMARTIN
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/27/2023 APPROVED RGROSS
ROW FIELD SURVEY /GRADING CERTIFICATION 01/27/2023 APPROVED RGROSS
ROW - FINAL INSPECTION 01/27/2023 APPROVED RGROSS
ELECTRIC - EARLY POWER 01/13/2023 CANCELLED BY APPLICANT WEB
ELECTRIC - EARLY POWER 01/13/2023 APPROVED JMUNSON
Note: 1/12/2023 - PREVIOUS INSPECTION NOTES Not ready. Label disconnects A and B
ELECTRIC - EARLY POWER 01/12/2023 Disapproved - NO FEE JMUNSON
Note: Not ready. Label disconnects A and B
ELECTRIC - EARLY POWER 01/12/2023 CANCELLED BY APPLICANT WEB
ELECTRIC - EARLY POWER 01/12/2023 CANCELLED BY APPLICANT WEB
ROW- PRE-APRON (PRE-POUR) 12/28/2022 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
U - SEWER TIE IN 11/03/2022 APPROVED RMARTIN
GRAVITY SEWER TEST 11/03/2022 APPROVED RMARTIN
PEP TANK INSTALLATION REQUEST 10/19/2022 APPROVED CSTONE
INSULATION 09/08/2022 APPROVED FWILLIS
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION LEFT UNIT ELECTRICAL PANEL IN GARAGE NOT FIRE FOAMED. ALSO IN THE LAUNDRY ROOM, PVC PIPES NOT FIRE FOAMED. 9/6/22 - NOTHING DONE. SAME ITEMS OPEN. 9-7-22 vent stack at top plate in laundryroom still no evidence of fire foam
INSULATION 09/07/2022 Disapproved - NO FEE LMILLER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION LEFT UNIT ELECTRICAL PANEL IN GARAGE NOT FIRE FOAMED. ALSO IN THE LAUNDRY ROOM, PVC PIPES NOT FIRE FOAMED. 9/6/22 - NOTHING DONE. SAME ITEMS OPEN. 9-7-22 vent stack at top plate in laundryroom still no evidence of fire foam
INSULATION 09/06/2022 Disapproved -FEE REQUIRED FWILLIS
Note: THIS IS A REINSPECTION LEFT UNIT ELECTRICAL PANEL IN GARAGE NOT FIRE FOAMED. ALSO IN THE LAUNDRY ROOM, PVC PIPES NOT FIRE FOAMED. 9/6/22 - NOTHING DONE. SAME ITEMS OPEN.
INSULATION 09/02/2022 Disapproved - NO FEE FWILLIS
Note: LEFT UNIT ELECTRICAL PANEL IN GARAGE NOT FIRE FOAMED. ALSO IN THE LAUNDRY ROOM, PVC PIPES NOT FIRE FOAMED.
LATH/BRICK/ WATER BARRIER 09/02/2022 APPROVED FWILLIS
ALL ROUGH 08/25/2022 APPROVED DCUSHING
Note: THIS IS A REINSPECTION NEED TO HAVE CONDUCTORS LANDED IN OUTSIDE SERVICE ON LUGS, LUGS ARE MISSING FOR OVERHEAD CONDUCTORS, NEED TO CHECK ALL SMOKE DETECTORS IN RELATION TO FAN BOXES IN BED ROOMS AND SUPPLY DUCTS, RIGHT SIDE UNIT ENTERING FROM FRONT DOOR 12-2 ROMEX TO THE LEFT NEEDS STRAP WITHIN 12" OF OUTLET BOX
ALL ROUGH 08/23/2022 Disapproved - NO FEE RMARTIN
Note: NEED TO HAVE CONDUCTORS LANDED IN OUTSIDE SERVICE ON LUGS, LUGS ARE MISSING FOR OVERHEAD CONDUCTORS, NEED TO CHECK ALL SMOKE DETECTORS IN RELATION TO FAN BOXES IN BED ROOMS AND SUPPLY DUCTS, RIGHT SIDE UNIT ENTERING FROM FRONT DOOR 12-2 ROMEX TO THE LEFT NEEDS STRAP WITHIN 12" OF OUTLET BOX
FIREWALL DRYWALL NAILING 08/05/2022 APPROVED RMARTIN
FIREWALL FINAL 08/05/2022 APPROVED RMARTIN
ROOF VALLEY & METAL 07/21/2022 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/14/2022 APPROVED FWILLIS
Note: THIS IS A REINSPECTION one section of fire rated roof sheathing appears to be missing, no set of approved plans on site to verify detail 7/14/22 - Firewall will be inspected separately.
WALL SHEATHING 07/12/2022 APPROVED DCUSHING
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/12/2022 Disapproved - NO FEE DCUSHING
Note: one section of fire rated roof sheathing appears to be missing, no set of approved plans on site to verify detail
TIE BEAM / LINTEL 06/08/2022 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 05/31/2022 APPROVED AMOBLEY
MONOLITHIC SLAB 05/03/2022 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 03/24/2022 APPROVED MKRASKI
WATER METER INSTALLATION REQUEST 02/15/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 02/07/2023 02/07/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/31/2022 05/31/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/31/2022 05/31/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 01/27/2022 01/27/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 01/27/2022 01/27/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 01/27/2022 01/28/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
SWALE COMPLETE 01/21/2022 03/17/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 01/20/2022 01/21/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Demising Wall Section on A-2 references detail ‘A’ on sheet A-7. No sheet A7 was submitted. 2. Properly identify Florida Product Approval Number (i.e. 11470); the submitted number was either invalid or expired.
CUSVC COMPLETE 01/20/2022 01/26/2022
Note: Released By: HALEIGH HAND - -
ELEC HOLD 01/20/2022 01/20/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need to reference the correct NEC year
ENGIN1 COMPLETE 01/20/2022 01/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 01/20/2022 01/24/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 01/20/2022 01/21/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Plans show R38 insulation in attic. Energy Calcs say R30. Revise to match
SW1 COMPLETE 01/20/2022 01/26/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 01/20/2022 01/21/2022
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 02/10/2023
PLAN REVIEW - REVISION ¤32.50 02/10/2023
REINSPECTION RESIDENTIAL ¤40.00 02/10/2023
CONNECTION FEES ¤2,155.76 01/28/2022
METER - DEPOSIT ¤120.00 01/28/2022
WATER- TURN ON ¤50.00 01/28/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/28/2022
INSPECTION - RESIDENTIAL ¤959.75 01/28/2022
PLAN REVIEW - RESIDENTIAL ¤272.22 01/28/2022
3% FIRE IMPACT FEE CREDIT (¤23.32) 01/28/2022
IMPACT FEE FIRE ¤777.30 01/28/2022
IMPACT FEE PARKS ¤2,910.26 01/28/2022
IMPACT FEE SCHOOL ¤7,200.00 01/28/2022
IMPACT FEE TRANSPORTATION ¤2,738.00 01/28/2022
WATER -IRRIGATION INSPECTION ¤50.00 01/28/2022
3% PARKS IMPACT FEE CREDIT (¤87.31) 01/28/2022
SURCHARGE FS 533.721 ¤13.25 01/28/2022
SURCHARGE - FS 468.631 ¤19.88 01/28/2022
SW ENG - FOUNDATION SURVEY ¤20.00 01/28/2022
SW ENG INSPECTION 80 ¤80.00 01/28/2022
SW ENG PRE APRON ¤30.00 01/28/2022
SW ENG - REVIEW 20 ¤20.00 01/28/2022
SW ENG RES REVIEW 200 ¤200.00 01/28/2022
3% TRANS IMPACT FEE CREDIT (¤82.14) 01/28/2022
SEWER CREDIT (¤1,806.00) 01/28/2022
SEWER INSPECTION ¤25.00 01/28/2022
SEWER CAPITAL FACILITY ¤9,879.52 01/28/2022
WATER CAPITAL FACILITY FEE ¤7,253.00 01/28/2022
SITE PLAN 30 ¤30.00 01/28/2022
Fees Total Due: ¤0.00 Total Paid: ¤32,927.67