Permit #2022011130

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00210-0200
Total Square Footage: 2728 sqft
Block: 00210
Subdivision: 2155 - SECTION 32-ROYAL PALMS
Job Phone: 847-942-1764
Location Address: 10 ROYAL LEAF LN
Type: RF - REROOF
Issue Date: 01/26/2022
NOC: RECORDED
Applicant name: MATTHEW BREITENGROSS
Owner: JENSEN FRED J & ALICE M H&W

Address

15 PRINCESS KIM LANE

PALM COAST, FL 32164

Lot: 0200
Contracted Stated Job Value: ¤15,000.00
Job Description: REROOF
Type: CN

Contractor

EXTREME WEATHER CONSULTING, LLC
Status Location Address State License Number Phone
CANCEL

2206 NW 39TH AVE

CAPE CORAL, FL 33993

CCC1332204 (Exp: 08/22/2022) 847-942-1764

Inspection History

Type Request Date Result Inspector
ROOF FINAL 04/07/2022 FINAL APPROVED DCUSHING
Note: THIS IS A REINSPECTION The gutter guards installed on the left and rear of the building are not allowing the eave shingles to adhere to the starter strips below.
ROOF FINAL 03/18/2022 Disapproved - NO FEE JWALKER
Note: The gutter guards installed on the left and rear of the building are not allowing the eave shingles to adhere to the starter strips below.
ROOF AFFIDAVIT 02/08/2022 APPROVED BBEMBRY
ROOF IN PROGRESS- MIDROOF 02/03/2022 APPROVED JWALKER
Note: THIS IS A REINSPECTION First stop appx 8:30 roof not ready 2nd stop 12:15 Drip edge has not been nail as per code. The off ridge vent are being plywooded over and ridge vents being used. blocking was not added and the plywood is not nailed properly. Remove and install nailers. The plywood fix at the left front above bath window is not replaced properly. A 6" x 2" piece was used and a 1' x 2' piece and part of the rotted plywood was not removed. Plywood replace needs to be a minium of 2' wide and span minimum of two trusses. No shingles have been installed.
ROOF IN PROGRESS- MIDROOF 02/02/2022 Disapproved -FEE REQUIRED JWALKER
Note: First stop appx 8:30 roof not ready 2nd stop 12:15 Drip edge has not been nail as per code. The off ridge vent are being plywooded over and ridge vents being used. blocking was not added and the plywood is not nailed properly. Remove and install nailers. The plywood fix at the left front above bath window is not replaced properly. A 6" x 2" piece was used and a 1' x 2' piece and part of the rotted plywood was not removed. Plywood replace needs to be a minium of 2' wide and span minimum of two trusses. No shingles have been installed.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 03/18/2022
SURCHARGE FS 533.721 ¤2.00 01/26/2022
SURCHARGE - FS 468.631 ¤2.00 01/26/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/26/2022
INSPECTION - RESIDENTIAL ¤60.00 01/26/2022
Fees Total Due: ¤0.00 Total Paid: ¤134.00