I want to search for...

Permit #2022011152

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00290-0200
GARAGE: 532 sqft
CONDITIONED SPACE: 2250 sqft
OPENED PORCH (WITH ROOF) : 340 sqft
Total Square Footage: 3122 sqft
Block: 00290
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 863-647-5815
Location Address: 5 EASTVUE PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/04/2022
NOC: RECORDED
Applicant name: MARK ALLAN HULBERT
Owner: HULBERT HOMES INC

Address

PO BOX 6254

LAKELAND, FL 33807

Lot: 0200
Contracted Stated Job Value: ¤279,000.00
Job Description: Single Family Residence
Type: CN

Contractor

HULBERT HOMES INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 6254

LAKELAND, FL 33813

CRC1331304 (Exp: 08/31/2026) 863-647-5815

Sub Contractors

BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
ANTONIO VINCENZO DAHM
Status Location Address State License Number Phone
ACTIVE

10 RYBAR LANE

PALM COAST, FL 32164

CFC1429951 (Exp: 08/31/2026) 386-237-5692

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/19/2022 FINAL APPROVED RMARTIN
Note: 12/15/2022 - PREVIOUS INSPECTION NOTES 12/15/22 All Items listed EXCEPT for the spray foam insulation have been addressed. 12/14/2022 - PREVIOUS INSPECTION NOTES 12/14/22 Previous starred note still not resolved. 1). Breaker for AHU is wrong size. Max 35amp as indicated on unit. 40amp is installed in panel. 12/5/2022 - PREVIOUS INSPECTION NOTES 12/5/22: 1). Continuous feed Garbage disposal is missing a switch. (also unplugged) 2). Breaker for AHU is wrong size. Unit sticker calls for a 15AMP max but a 40 is installed. 3). Specifications for spray foam in attic space above garage have not been submitted. *** Garage door deadbolt & back slider lock are not functioning. Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2490 The storage area above the garage where spary from has been installed will need to a thermal barrier installed or provide specifications on the rating of the foam. R316.5.3 Attics. The thermal barrier specified in Section R316.4 is not required where all of the following apply: 1. Attic access is required by Section R807.1. 2. The space is entered only for purposes of repairs or maintenance. 3. The foam plastic insulation has been tested in accordance with Section R316.6 or the foam plastic insulation is protected against ignition using one of the following ignition barrier materials: 3.1. 11/2-inch-thick (38 mm) mineral fiber insulation. 3.2. 1/4-inch-thick (6.4 mm) wood structural panels. 3.3. 3/8-inch (9.5 mm) particleboard. 3.4. 1/4-inch (6.4 mm) hardboard. 3.5. 3/8-inch (9.5 mm) gypsum board. 3.6. Corrosion-resistant steel having a base metal thickness of 0.016 inch (0.406 mm). 3.7. 11/2-inch-thick (38 mm) cellulose insulation; or 3.8. 1/4-inch (6.4 mm) fiber-cement panel, soffit or backer board. The ignition barrier is not required where the foam plastic insulation has been tested in accordance with Section R316.6. 7/21/22 Specifications for spray foam have not been provided.
BLD - BUILDING FINAL 12/15/2022 Disapproved -FEE REQUIRED JWALKER
Note: 12/15/22 All Items listed EXCEPT for the spray foam insulation have been addressed. 12/14/2022 - PREVIOUS INSPECTION NOTES 12/14/22 Previous starred note still not resolved. 1). Breaker for AHU is wrong size. Max 35amp as indicated on unit. 40amp is installed in panel. 12/5/2022 - PREVIOUS INSPECTION NOTES 12/5/22: 1). Continuous feed Garbage disposal is missing a switch. (also unplugged) 2). Breaker for AHU is wrong size. Unit sticker calls for a 15AMP max but a 40 is installed. 3). Specifications for spray foam in attic space above garage have not been submitted. *** Garage door deadbolt & back slider lock are not functioning. Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2490 The storage area above the garage where spary from has been installed will need to a thermal barrier installed or provide specifications on the rating of the foam. R316.5.3 Attics. The thermal barrier specified in Section R316.4 is not required where all of the following apply: 1. Attic access is required by Section R807.1. 2. The space is entered only for purposes of repairs or maintenance. 3. The foam plastic insulation has been tested in accordance with Section R316.6 or the foam plastic insulation is protected against ignition using one of the following ignition barrier materials: 3.1. 11/2-inch-thick (38 mm) mineral fiber insulation. 3.2. 1/4-inch-thick (6.4 mm) wood structural panels. 3.3. 3/8-inch (9.5 mm) particleboard. 3.4. 1/4-inch (6.4 mm) hardboard. 3.5. 3/8-inch (9.5 mm) gypsum board. 3.6. Corrosion-resistant steel having a base metal thickness of 0.016 inch (0.406 mm). 3.7. 11/2-inch-thick (38 mm) cellulose insulation; or 3.8. 1/4-inch (6.4 mm) fiber-cement panel, soffit or backer board. The ignition barrier is not required where the foam plastic insulation has been tested in accordance with Section R316.6. 7/21/22 Specifications for spray foam have not been provided.
BLD - BUILDING FINAL 12/14/2022 Disapproved -FEE REQUIRED RSIMS
Note: 12/14/22 Previous starred note still not resolved. 1). Breaker for AHU is wrong size. Max 35amp as indicated on unit. 40amp is installed in panel. 12/5/2022 - PREVIOUS INSPECTION NOTES 12/5/22: 1). Continuous feed Garbage disposal is missing a switch. (also unplugged) 2). Breaker for AHU is wrong size. Unit sticker calls for a 15AMP max but a 40 is installed. 3). Specifications for spray foam in attic space above garage have not been submitted. *** Garage door deadbolt & back slider lock are not functioning. Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2490 The storage area above the garage where spary from has been installed will need to a thermal barrier installed or provide specifications on the rating of the foam. R316.5.3 Attics. The thermal barrier specified in Section R316.4 is not required where all of the following apply: 1. Attic access is required by Section R807.1. 2. The space is entered only for purposes of repairs or maintenance. 3. The foam plastic insulation has been tested in accordance with Section R316.6 or the foam plastic insulation is protected against ignition using one of the following ignition barrier materials: 3.1. 11/2-inch-thick (38 mm) mineral fiber insulation. 3.2. 1/4-inch-thick (6.4 mm) wood structural panels. 3.3. 3/8-inch (9.5 mm) particleboard. 3.4. 1/4-inch (6.4 mm) hardboard. 3.5. 3/8-inch (9.5 mm) gypsum board. 3.6. Corrosion-resistant steel having a base metal thickness of 0.016 inch (0.406 mm). 3.7. 11/2-inch-thick (38 mm) cellulose insulation; or 3.8. 1/4-inch (6.4 mm) fiber-cement panel, soffit or backer board. The ignition barrier is not required where the foam plastic insulation has been tested in accordance with Section R316.6. 7/21/22 Specifications for spray foam have not been provided.
ROW - STORMWATER FINAL 12/06/2022 FINAL APPROVED PFLANAGAN
Note: 12/5/2022 - PREVIOUS INSPECTION NOTES 12/05/22= facing the house on the left side by the edge of the road is missing some sod. picture attached,I LEFT IT PAINTED WITH PINK SPRAY PAINT
U -UTILITY RESIDENTIAL FINAL 12/05/2022 FINAL APPROVED JHARDING
ROW - STORMWATER FINAL 12/05/2022 Disapproved - NO FEE GBERTOLA
Note: 12/05/22= facing the house on the left side by the edge of the road is missing some sod. picture attached,I LEFT IT PAINTED WITH PINK SPRAY PAINT
U-CROSS CONNECTION 12/05/2022 APPROVED - AS NOTED JHARDING
Note: No cross connections.
BLD - BUILDING FINAL 12/05/2022 Disapproved - NO FEE RSIMS
Note: 12/5/22: 1). Continuous feed Garbage disposal is missing a switch. (also unplugged) 2). Breaker for AHU is wrong size. Unit sticker calls for a 15AMP max but a 40 is installed. 3). Specifications for spray foam in attic space above garage have not been submitted. *** Garage door deadbolt & back slider lock are not functioning. Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2490 The storage area above the garage where spary from has been installed will need to a thermal barrier installed or provide specifications on the rating of the foam. R316.5.3 Attics. The thermal barrier specified in Section R316.4 is not required where all of the following apply: 1. Attic access is required by Section R807.1. 2. The space is entered only for purposes of repairs or maintenance. 3. The foam plastic insulation has been tested in accordance with Section R316.6 or the foam plastic insulation is protected against ignition using one of the following ignition barrier materials: 3.1. 11/2-inch-thick (38 mm) mineral fiber insulation. 3.2. 1/4-inch-thick (6.4 mm) wood structural panels. 3.3. 3/8-inch (9.5 mm) particleboard. 3.4. 1/4-inch (6.4 mm) hardboard. 3.5. 3/8-inch (9.5 mm) gypsum board. 3.6. Corrosion-resistant steel having a base metal thickness of 0.016 inch (0.406 mm). 3.7. 11/2-inch-thick (38 mm) cellulose insulation; or 3.8. 1/4-inch (6.4 mm) fiber-cement panel, soffit or backer board. The ignition barrier is not required where the foam plastic insulation has been tested in accordance with Section R316.6. 7/21/22 Specifications for spray foam have not been provided.
ROW - FINAL APRON (AFTER POUR) 12/02/2022 APPROVED PFLANAGAN
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/02/2022 APPROVED PFLANAGAN
Note: 11/7/2022 - PREVIOUS INSPECTION NOTES 11/07/22=The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet WATER IS BEING TRAPED IN THE BACK ON THE RIGHT SIDE NEED TO REGRADE IF THIS IS THE ISSUE OR IF GRADE IS RIGHT NEED TO GET YOUR SURVEYOR TO SHOW THATS NOT BEING TRAPED ------------------------------------------------------------------------------------------------------------------------- 10/11/2022 - PREVIOUS INSPECTION NOTES 1) RIGHT OF WAY LINE NEED TO BE GREATER OR HIGHER THEN THE CENTER LINE OF ROAD 2) CULVERT PIPE IS OUT OF TOLERANCE 3) WATER IS BEING TRAPED IN THE BACK ON THE RIGHT SIDE NEED TO REGRADE IF THIS IS THE ISSUE OR IF GRADE IS RIGHT NEED TO GET YOUR SURVEYOR TO SHOW THATS NOT BEING TRAPED 4) NEED TO HAVE .10 OF FALL FROM BACK TO FRONT
ROW FIELD SURVEY /GRADING CERTIFICATION 12/02/2022 APPROVED PFLANAGAN
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/07/2022 Disapproved -FEE REQUIRED GBERTOLA
Note: 11/07/22=The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet WATER IS BEING TRAPED IN THE BACK ON THE RIGHT SIDE NEED TO REGRADE IF THIS IS THE ISSUE OR IF GRADE IS RIGHT NEED TO GET YOUR SURVEYOR TO SHOW THATS NOT BEING TRAPED ------------------------------------------------------------------------------------------------------------------------- 10/11/2022 - PREVIOUS INSPECTION NOTES 1) RIGHT OF WAY LINE NEED TO BE GREATER OR HIGHER THEN THE CENTER LINE OF ROAD 2) CULVERT PIPE IS OUT OF TOLERANCE 3) WATER IS BEING TRAPED IN THE BACK ON THE RIGHT SIDE NEED TO REGRADE IF THIS IS THE ISSUE OR IF GRADE IS RIGHT NEED TO GET YOUR SURVEYOR TO SHOW THATS NOT BEING TRAPED 4) NEED TO HAVE .10 OF FALL FROM BACK TO FRONT
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/11/2022 Disapproved - NO FEE PFLANAGAN
Note: 1) RIGHT OF WAY LINE NEED TO BE GREATER OR HIGHER THEN THE CENTER LINE OF ROAD 2) CULVERT PIPE IS OUT OF TOLERANCE 3) WATER IS BEING TRAPED IN THE BACK ON THE RIGHT SIDE NEED TO REGRADE IF THIS IS THE ISSUE OR IF GRADE IS RIGHT NEED TO GET YOUR SURVEYOR TO SHOW THATS NOT BEING TRAPED 4) NEED TO HAVE .10 OF FALL FROM BACK TO FRONT
U - SEWER TIE IN 09/22/2022 APPROVED MGIBSON
Note: 9/21/2022 - PREVIOUS INSPECTION NOTES
GRAVITY SEWER TEST 09/22/2022 APPROVED MGIBSON
Note: 9/21/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 sewer ran to approximatly where pep tank will be place, C/M NEEDS TO SCHEDULE GRAVITY SEWER INSPECTION
GRAVITY SEWER TEST 09/21/2022 CANCELLED BY APPLICANT MGIBSON
Note: Inspector Notes from Inspection 2060 sewer ran to approximatly where pep tank will be place, C/M NEEDS TO SCHEDULE GRAVITY SEWER INSPECTION
U - SEWER TIE IN 09/21/2022 CANCELLED BY APPLICANT MGIBSON
PEP TANK INSTALLATION REQUEST 09/12/2022 APPROVED CSTONE
Note: THIS IS A REINSPECTION ADDED ON 9/2/2022 10:49:51 AM THIS IS A REINSPECTION ADDED ON 8/15/2022 12:07:03 PM THIS IS A REINSPECTION ADDED ON 7/26/2022 2:17:58 PM Exterior (stucco, stone, or siding must be applied) Dumpster in the way Dumpster needs to move
ELECTRIC - EARLY POWER 09/06/2022 APPROVED JMUNSON
Note: THIS IS A REINSPECTION Inspector Notes from Inspection 2170 Emailed FPL @ 2:30 PM Cancelled09/2/2022
ELECTRIC - EARLY POWER 09/02/2022 CANCELLED BY APPLICANT TSTAUFFACHER
Note: Inspector Notes from Inspection 2170 Emailed FPL @ 2:30 PM Cancelled09/2/2022
PEP TANK INSTALLATION REQUEST 09/02/2022 Disapproved -FEE REQUIRED CSTONE
Note: THIS IS A REINSPECTION ADDED ON 8/15/2022 12:07:03 PM THIS IS A REINSPECTION ADDED ON 7/26/2022 2:17:58 PM Exterior (stucco, stone, or siding must be applied) Dumpster in the way Dumpster needs to move
ROW- PRE-APRON (PRE-POUR) 08/30/2022 APPROVED RGROSS
Note: THIS IS A REINSPECTION NEED TO DIG OUT FOOTERS NEED TO HAVE ALL ASPHALT OUT OF POURING AREA CULVERT PIPE NEEDS TO BE BACK FILLED HALF WAY UP ON PIPE NEED TO HAVE THE SWALE DAIGRAM IN PERMIT BOX CULVERT PIPE IS OUT OF TOLERANCE
ROW- PRE-APRON (PRE-POUR) 08/15/2022 Disapproved -FEE REQUIRED PFLANAGAN
Note: NEED TO DIG OUT FOOTERS NEED TO HAVE ALL ASPHALT OUT OF POURING AREA CULVERT PIPE NEEDS TO BE BACK FILLED HALF WAY UP ON PIPE NEED TO HAVE THE SWALE DAIGRAM IN PERMIT BOX CULVERT PIPE IS OUT OF TOLERANCE
PEP TANK INSTALLATION REQUEST 08/15/2022 Disapproved -FEE REQUIRED CSTONE
Note: THIS IS A REINSPECTION ADDED ON 7/26/2022 2:17:58 PM Exterior (stucco, stone, or siding must be applied) Dumpster in the way
PEP TANK INSTALLATION REQUEST 07/26/2022 Disapproved - NO FEE CSTONE
Note: Exterior (stucco, stone, or siding must be applied)
LATH/BRICK/ WATER BARRIER 07/21/2022 APPROVED - AS NOTED KSANDOE
Note: Inspector Notes from Inspection 2490 The storage area above the garage where spary from has been installed will need to a thermal barrier installed or provide specifications on the rating of the foam. R316.5.3 Attics. The thermal barrier specified in Section R316.4 is not required where all of the following apply: 1. Attic access is required by Section R807.1. 2. The space is entered only for purposes of repairs or maintenance. 3. The foam plastic insulation has been tested in accordance with Section R316.6 or the foam plastic insulation is protected against ignition using one of the following ignition barrier materials: 3.1. 11/2-inch-thick (38 mm) mineral fiber insulation. 3.2. 1/4-inch-thick (6.4 mm) wood structural panels. 3.3. 3/8-inch (9.5 mm) particleboard. 3.4. 1/4-inch (6.4 mm) hardboard. 3.5. 3/8-inch (9.5 mm) gypsum board. 3.6. Corrosion-resistant steel having a base metal thickness of 0.016 inch (0.406 mm). 3.7. 11/2-inch-thick (38 mm) cellulose insulation; or 3.8. 1/4-inch (6.4 mm) fiber-cement panel, soffit or backer board. The ignition barrier is not required where the foam plastic insulation has been tested in accordance with Section R316.6. 7/21/22 Specifications for spray foam have not been provided.
INSULATION 07/15/2022 APPROVED - AS NOTED JWALKER
Note: The storage area above the garage where spary from has been installed will need to a thermal barrier installed or provide specifications on the rating of the foam. R316.5.3 Attics. The thermal barrier specified in Section R316.4 is not required where all of the following apply: 1. Attic access is required by Section R807.1. 2. The space is entered only for purposes of repairs or maintenance. 3. The foam plastic insulation has been tested in accordance with Section R316.6 or the foam plastic insulation is protected against ignition using one of the following ignition barrier materials: 3.1. 11/2-inch-thick (38 mm) mineral fiber insulation. 3.2. 1/4-inch-thick (6.4 mm) wood structural panels. 3.3. 3/8-inch (9.5 mm) particleboard. 3.4. 1/4-inch (6.4 mm) hardboard. 3.5. 3/8-inch (9.5 mm) gypsum board. 3.6. Corrosion-resistant steel having a base metal thickness of 0.016 inch (0.406 mm). 3.7. 11/2-inch-thick (38 mm) cellulose insulation; or 3.8. 1/4-inch (6.4 mm) fiber-cement panel, soffit or backer board. The ignition barrier is not required where the foam plastic insulation has been tested in accordance with Section R316.6.
INSULATION 07/14/2022 CANCELLED BY APPLICANT WEB
ALL ROUGH 07/12/2022 APPROVED JWALKER
Note: THIS IS A REINSPECTION Nail plates missing, Top plate garage wall. dining wall. front entry. Front bed room wall, Check all areas Top of the front arch windows not fastened. Wire not phased out in electical panel. Where the miro wave exhaust vent penentrates the top plate of the kitchen wall strap wall and install fire blocking.
ALL ROUGH 07/08/2022 Disapproved - NO FEE JWALKER
Note: Nail plates missing, Top plate garage wall. dining wall. front entry. Front bed room wall, Check all areas Top of the front arch windows not fastened. Wire not phased out in electical panel. Where the miro wave exhaust vent penentrates the top plate of the kitchen wall strap wall and install fire blocking.
ALL ROUGH 07/07/2022 CANCELLED BY APPLICANT WEB
ROOF VALLEY & METAL 06/17/2022 APPROVED JWALKER
Note: THIS IS A REINSPECTION The synthetic underlayment is to be fastened 6" o.c. at the laps and ends and 12" o.c. in the field. The field nailing is good the nailing needs to be corrected.
ROOF VALLEY & METAL 06/03/2022 Disapproved - NO FEE JWALKER
Note: The synthetic underlayment is to be fastened 6" o.c. at the laps and ends and 12" o.c. in the field. The field nailing is good the nailing needs to be corrected.
WALL SHEATHING 06/01/2022 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/01/2022 APPROVED - AS NOTED JWALKER
Note: Garage wall. Post under the Girder truss calls for a concrete to post base. Detail on page GN of the prints. Check at all rough,
FOUND SURVEY APPROVED (OFFICE) 05/31/2022 APPROVED TBAKER
TIE BEAM / LINTEL 05/09/2022 APPROVED JWALKER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1) The front entry area where the walls step up. Rebar pieces have been dropped down the block wall cells and tie to the dowels. To give the appearance of a full down rod. Down rods are to be continous from top of wall to bottom. Highlighted the drawings. Check all down rods in this area. 2) Missing down cell at front entry door right hand side. Missing dowel on right side garage wall. 5/5/22 Above listed corrections have not been fully made. Rebar is to be continuous. The missed dowel at the right side front column was not drilled the required 6" depth and set in epoxy and was easily pulled out,
TIE BEAM / LINTEL 05/05/2022 Disapproved -FEE REQUIRED JWALKER
Note: THIS IS A REINSPECTION 1) The front entry area where the walls step up. Rebar pieces have been dropped down the block wall cells and tie to the dowels. To give the appearance of a full down rod. Down rods are to be continous from top of wall to bottom. Highlighted the drawings. Check all down rods in this area. 2) Missing down cell at front entry door right hand side. Missing dowel on right side garage wall. 5/5/22 Above listed corrections have not been fully made. Rebar is to be continuous. The missed dowel at the right side front column was not drilled the required 6" depth and set in epoxy and was easily pulled out,
ELECTRIC TEMP POLE 05/03/2022 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 2:30 PM
ELECTRIC TEMP POLE 04/28/2022 Disapproved - NO FEE JWALKER
Note: The top GFIC outlet is cracked in half, and needs to be replaced.
TIE BEAM / LINTEL 04/27/2022 Disapproved -FEE REQUIRED JWALKER
Note: 1) The front entry area where the walls step up. Rebar pieces have been dropped down the block wall cells and tie to the dowels. To give the appearance of a full down rod. Down rods are to be continous from top of wall to bottom. Highlighted the drawings. Check all down rods in this area. 2) Missing down cell at front entry door right hand side. Missing dowel on right side garage wall.
MONOLITHIC SLAB 03/31/2022 APPROVED KSANDOE
Note: THIS IS A REINSPECTION 3/30/ FBC SECTION 1907 MINIMUM SLAB PROVISIONS 1907.1 General. The thickness of concrete floor slabs supported directly on the ground shall not be less than 3 1/2 inches. Slab is showing shallow areas of 2" in some locations. (3) test string lines have been left in place for contractors reference. Dig out excess soil, A termite retreat will need to be done due to soil being removed.
MONOLITHIC SLAB 03/30/2022 Disapproved - NO FEE JWALKER
Note: 3/30/ FBC SECTION 1907 MINIMUM SLAB PROVISIONS 1907.1 General. The thickness of concrete floor slabs supported directly on the ground shall not be less than 3 1/2 inches. Slab is showing shallow areas of 2" in some locations. (3) test string lines have been left in place for contractors reference. Dig out excess soil, A termite retreat will need to be done due to soil being removed.
MONOLITHIC SLAB 03/28/2022 CANCELLED BY APPLICANT JWALKER
PLUMBING 1ST ROUGH UNDERGROUND 02/28/2022 APPROVED - AS NOTED MGIBSON
Note: sewer ran to approximatly where pep tank will be place, C/M NEEDS TO SCHEDULE GRAVITY SEWER INSPECTION
WATER METER INSTALLATION REQUEST 02/23/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
BADMIN INFORMATION 11/09/2022 11/09/2022
Note: Marked INFORMATION By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM PLEASE SUBMIT THE CERTIFICATE OF COMPLETION FOR THE TERMITE THIS NOT THE CERTIFICATE.
ENGIN1 COMPLETE 05/31/2022 05/31/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/31/2022 05/31/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 02/02/2022 02/02/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 02/02/2022 02/03/2022
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
ELEC COMPLETE 02/02/2022 02/02/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 01/26/2022 04/04/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 01/25/2022 01/26/2022
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM 1. Product Approval Specification Sheet clarification per F.S. 553.842: a. FL 474.115- for wood anchors cannot be found on approved listing. Please verify the number. b. FL 5259.1-R33 - for roofing underlayment does not match with the number shown on Roofing Worksheet. Please coordinate and resubmit the correct one to be used.
CUSVC COMPLETE 01/25/2022 02/01/2022
Note: Released By: HALEIGH HAND - -
ELEC HOLD 01/25/2022 01/26/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to reference the correct NEC code year. 2. Need to reference the correct FBC year and edition on the note in the garage about the AHU in the attic.
ENGIN1 COMPLETE 01/25/2022 01/26/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 01/25/2022 01/28/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 01/25/2022 01/26/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Duct layout needs to be signed by the AC contractor
SW1 COMPLETE 01/25/2022 02/01/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 01/25/2022 01/26/2022
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/19/2022
REINSPECTION RESIDENTIAL ¤40.00 12/19/2022
SW ENG REINSPECTION 30 ¤30.00 11/07/2022
UTILITY PEP REINSPECTION ¤40.00 11/07/2022
UTILITY PEP REINSPECTION ¤40.00 11/07/2022
REINSPECTION RESIDENTIAL ¤40.00 11/07/2022
REINSPECTION RESIDENTIAL ¤40.00 11/07/2022
SEWER CREDIT (¤850.00) 02/04/2022
SEWER INSPECTION ¤25.00 02/04/2022
SEWER CAPITAL FACILITY ¤4,939.76 02/04/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 02/04/2022
SITE PLAN 30 ¤30.00 02/04/2022
SW ENG - REVIEW 20 ¤20.00 02/04/2022
SW ENG RES REVIEW 200 ¤200.00 02/04/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 02/04/2022
METER - DEPOSIT ¤60.00 02/04/2022
WATER- TURN ON ¤25.00 02/04/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/04/2022
INSPECTION - RESIDENTIAL ¤783.75 02/04/2022
PLAN REVIEW - RESIDENTIAL ¤222.30 02/04/2022
CONNECTION FEES ¤1,077.88 02/04/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 02/04/2022
IMPACT FEE FIRE ¤388.65 02/04/2022
IMPACT FEE PARKS ¤1,455.13 02/04/2022
IMPACT FEE SCHOOL ¤3,600.00 02/04/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 02/04/2022
WATER -IRRIGATION INSPECTION ¤25.00 02/04/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 02/04/2022
SURCHARGE FS 533.721 ¤10.93 02/04/2022
SURCHARGE - FS 468.631 ¤16.40 02/04/2022
SW ENG - FOUNDATION SURVEY ¤20.00 02/04/2022
SW ENG INSPECTION 80 ¤80.00 02/04/2022
SW ENG PRE APRON ¤30.00 02/04/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,742.07