I want to search for...
Permit #2022011152
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-00290-0200 |
| GARAGE: 532 sqft |
| CONDITIONED SPACE: 2250 sqft |
| OPENED PORCH (WITH ROOF) : 340 sqft |
| Total Square Footage: 3122 sqft |
| Block: 00290 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 863-647-5815 |
| Location Address: 5 EASTVUE PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/04/2022 |
| NOC: RECORDED |
| Applicant name: MARK ALLAN HULBERT |
| Owner: HULBERT HOMES INC |
|
Address PO BOX 6254 LAKELAND, FL 33807 |
| Lot: 0200 |
| Contracted Stated Job Value: ¤279,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
HULBERT HOMES INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 6254 LAKELAND, FL 33813 |
CRC1331304 (Exp: 08/31/2026) | 863-647-5815 |
Sub Contractors
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
ANTONIO VINCENZO DAHM
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 RYBAR LANE PALM COAST, FL 32164 |
CFC1429951 (Exp: 08/31/2026) | 386-237-5692 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/19/2022 | FINAL APPROVED | RMARTIN |
| Note: 12/15/2022 - PREVIOUS INSPECTION NOTES 12/15/22 All Items listed EXCEPT for the spray foam insulation have been addressed. 12/14/2022 - PREVIOUS INSPECTION NOTES 12/14/22 Previous starred note still not resolved. 1). Breaker for AHU is wrong size. Max 35amp as indicated on unit. 40amp is installed in panel. 12/5/2022 - PREVIOUS INSPECTION NOTES 12/5/22: 1). Continuous feed Garbage disposal is missing a switch. (also unplugged) 2). Breaker for AHU is wrong size. Unit sticker calls for a 15AMP max but a 40 is installed. 3). Specifications for spray foam in attic space above garage have not been submitted. *** Garage door deadbolt & back slider lock are not functioning. Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2490 The storage area above the garage where spary from has been installed will need to a thermal barrier installed or provide specifications on the rating of the foam. R316.5.3 Attics. The thermal barrier specified in Section R316.4 is not required where all of the following apply: 1. Attic access is required by Section R807.1. 2. The space is entered only for purposes of repairs or maintenance. 3. The foam plastic insulation has been tested in accordance with Section R316.6 or the foam plastic insulation is protected against ignition using one of the following ignition barrier materials: 3.1. 11/2-inch-thick (38 mm) mineral fiber insulation. 3.2. 1/4-inch-thick (6.4 mm) wood structural panels. 3.3. 3/8-inch (9.5 mm) particleboard. 3.4. 1/4-inch (6.4 mm) hardboard. 3.5. 3/8-inch (9.5 mm) gypsum board. 3.6. Corrosion-resistant steel having a base metal thickness of 0.016 inch (0.406 mm). 3.7. 11/2-inch-thick (38 mm) cellulose insulation; or 3.8. 1/4-inch (6.4 mm) fiber-cement panel, soffit or backer board. The ignition barrier is not required where the foam plastic insulation has been tested in accordance with Section R316.6. 7/21/22 Specifications for spray foam have not been provided. | |||
| BLD - BUILDING FINAL | 12/15/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 12/15/22 All Items listed EXCEPT for the spray foam insulation have been addressed. 12/14/2022 - PREVIOUS INSPECTION NOTES 12/14/22 Previous starred note still not resolved. 1). Breaker for AHU is wrong size. Max 35amp as indicated on unit. 40amp is installed in panel. 12/5/2022 - PREVIOUS INSPECTION NOTES 12/5/22: 1). Continuous feed Garbage disposal is missing a switch. (also unplugged) 2). Breaker for AHU is wrong size. Unit sticker calls for a 15AMP max but a 40 is installed. 3). Specifications for spray foam in attic space above garage have not been submitted. *** Garage door deadbolt & back slider lock are not functioning. Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2490 The storage area above the garage where spary from has been installed will need to a thermal barrier installed or provide specifications on the rating of the foam. R316.5.3 Attics. The thermal barrier specified in Section R316.4 is not required where all of the following apply: 1. Attic access is required by Section R807.1. 2. The space is entered only for purposes of repairs or maintenance. 3. The foam plastic insulation has been tested in accordance with Section R316.6 or the foam plastic insulation is protected against ignition using one of the following ignition barrier materials: 3.1. 11/2-inch-thick (38 mm) mineral fiber insulation. 3.2. 1/4-inch-thick (6.4 mm) wood structural panels. 3.3. 3/8-inch (9.5 mm) particleboard. 3.4. 1/4-inch (6.4 mm) hardboard. 3.5. 3/8-inch (9.5 mm) gypsum board. 3.6. Corrosion-resistant steel having a base metal thickness of 0.016 inch (0.406 mm). 3.7. 11/2-inch-thick (38 mm) cellulose insulation; or 3.8. 1/4-inch (6.4 mm) fiber-cement panel, soffit or backer board. The ignition barrier is not required where the foam plastic insulation has been tested in accordance with Section R316.6. 7/21/22 Specifications for spray foam have not been provided. | |||
| BLD - BUILDING FINAL | 12/14/2022 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 12/14/22 Previous starred note still not resolved. 1). Breaker for AHU is wrong size. Max 35amp as indicated on unit. 40amp is installed in panel. 12/5/2022 - PREVIOUS INSPECTION NOTES 12/5/22: 1). Continuous feed Garbage disposal is missing a switch. (also unplugged) 2). Breaker for AHU is wrong size. Unit sticker calls for a 15AMP max but a 40 is installed. 3). Specifications for spray foam in attic space above garage have not been submitted. *** Garage door deadbolt & back slider lock are not functioning. Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2490 The storage area above the garage where spary from has been installed will need to a thermal barrier installed or provide specifications on the rating of the foam. R316.5.3 Attics. The thermal barrier specified in Section R316.4 is not required where all of the following apply: 1. Attic access is required by Section R807.1. 2. The space is entered only for purposes of repairs or maintenance. 3. The foam plastic insulation has been tested in accordance with Section R316.6 or the foam plastic insulation is protected against ignition using one of the following ignition barrier materials: 3.1. 11/2-inch-thick (38 mm) mineral fiber insulation. 3.2. 1/4-inch-thick (6.4 mm) wood structural panels. 3.3. 3/8-inch (9.5 mm) particleboard. 3.4. 1/4-inch (6.4 mm) hardboard. 3.5. 3/8-inch (9.5 mm) gypsum board. 3.6. Corrosion-resistant steel having a base metal thickness of 0.016 inch (0.406 mm). 3.7. 11/2-inch-thick (38 mm) cellulose insulation; or 3.8. 1/4-inch (6.4 mm) fiber-cement panel, soffit or backer board. The ignition barrier is not required where the foam plastic insulation has been tested in accordance with Section R316.6. 7/21/22 Specifications for spray foam have not been provided. | |||
| ROW - STORMWATER FINAL | 12/06/2022 | FINAL APPROVED | PFLANAGAN |
| Note: 12/5/2022 - PREVIOUS INSPECTION NOTES 12/05/22= facing the house on the left side by the edge of the road is missing some sod. picture attached,I LEFT IT PAINTED WITH PINK SPRAY PAINT | |||
| U -UTILITY RESIDENTIAL FINAL | 12/05/2022 | FINAL APPROVED | JHARDING |
| ROW - STORMWATER FINAL | 12/05/2022 | Disapproved - NO FEE | GBERTOLA |
| Note: 12/05/22= facing the house on the left side by the edge of the road is missing some sod. picture attached,I LEFT IT PAINTED WITH PINK SPRAY PAINT | |||
| U-CROSS CONNECTION | 12/05/2022 | APPROVED - AS NOTED | JHARDING |
| Note: No cross connections. | |||
| BLD - BUILDING FINAL | 12/05/2022 | Disapproved - NO FEE | RSIMS |
| Note: 12/5/22: 1). Continuous feed Garbage disposal is missing a switch. (also unplugged) 2). Breaker for AHU is wrong size. Unit sticker calls for a 15AMP max but a 40 is installed. 3). Specifications for spray foam in attic space above garage have not been submitted. *** Garage door deadbolt & back slider lock are not functioning. Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2490 The storage area above the garage where spary from has been installed will need to a thermal barrier installed or provide specifications on the rating of the foam. R316.5.3 Attics. The thermal barrier specified in Section R316.4 is not required where all of the following apply: 1. Attic access is required by Section R807.1. 2. The space is entered only for purposes of repairs or maintenance. 3. The foam plastic insulation has been tested in accordance with Section R316.6 or the foam plastic insulation is protected against ignition using one of the following ignition barrier materials: 3.1. 11/2-inch-thick (38 mm) mineral fiber insulation. 3.2. 1/4-inch-thick (6.4 mm) wood structural panels. 3.3. 3/8-inch (9.5 mm) particleboard. 3.4. 1/4-inch (6.4 mm) hardboard. 3.5. 3/8-inch (9.5 mm) gypsum board. 3.6. Corrosion-resistant steel having a base metal thickness of 0.016 inch (0.406 mm). 3.7. 11/2-inch-thick (38 mm) cellulose insulation; or 3.8. 1/4-inch (6.4 mm) fiber-cement panel, soffit or backer board. The ignition barrier is not required where the foam plastic insulation has been tested in accordance with Section R316.6. 7/21/22 Specifications for spray foam have not been provided. | |||
| ROW - FINAL APRON (AFTER POUR) | 12/02/2022 | APPROVED | PFLANAGAN |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/02/2022 | APPROVED | PFLANAGAN |
| Note: 11/7/2022 - PREVIOUS INSPECTION NOTES 11/07/22=The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet WATER IS BEING TRAPED IN THE BACK ON THE RIGHT SIDE NEED TO REGRADE IF THIS IS THE ISSUE OR IF GRADE IS RIGHT NEED TO GET YOUR SURVEYOR TO SHOW THATS NOT BEING TRAPED ------------------------------------------------------------------------------------------------------------------------- 10/11/2022 - PREVIOUS INSPECTION NOTES 1) RIGHT OF WAY LINE NEED TO BE GREATER OR HIGHER THEN THE CENTER LINE OF ROAD 2) CULVERT PIPE IS OUT OF TOLERANCE 3) WATER IS BEING TRAPED IN THE BACK ON THE RIGHT SIDE NEED TO REGRADE IF THIS IS THE ISSUE OR IF GRADE IS RIGHT NEED TO GET YOUR SURVEYOR TO SHOW THATS NOT BEING TRAPED 4) NEED TO HAVE .10 OF FALL FROM BACK TO FRONT | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/02/2022 | APPROVED | PFLANAGAN |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/07/2022 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 11/07/22=The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet WATER IS BEING TRAPED IN THE BACK ON THE RIGHT SIDE NEED TO REGRADE IF THIS IS THE ISSUE OR IF GRADE IS RIGHT NEED TO GET YOUR SURVEYOR TO SHOW THATS NOT BEING TRAPED ------------------------------------------------------------------------------------------------------------------------- 10/11/2022 - PREVIOUS INSPECTION NOTES 1) RIGHT OF WAY LINE NEED TO BE GREATER OR HIGHER THEN THE CENTER LINE OF ROAD 2) CULVERT PIPE IS OUT OF TOLERANCE 3) WATER IS BEING TRAPED IN THE BACK ON THE RIGHT SIDE NEED TO REGRADE IF THIS IS THE ISSUE OR IF GRADE IS RIGHT NEED TO GET YOUR SURVEYOR TO SHOW THATS NOT BEING TRAPED 4) NEED TO HAVE .10 OF FALL FROM BACK TO FRONT | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/11/2022 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) RIGHT OF WAY LINE NEED TO BE GREATER OR HIGHER THEN THE CENTER LINE OF ROAD 2) CULVERT PIPE IS OUT OF TOLERANCE 3) WATER IS BEING TRAPED IN THE BACK ON THE RIGHT SIDE NEED TO REGRADE IF THIS IS THE ISSUE OR IF GRADE IS RIGHT NEED TO GET YOUR SURVEYOR TO SHOW THATS NOT BEING TRAPED 4) NEED TO HAVE .10 OF FALL FROM BACK TO FRONT | |||
| U - SEWER TIE IN | 09/22/2022 | APPROVED | MGIBSON |
| Note: 9/21/2022 - PREVIOUS INSPECTION NOTES | |||
| GRAVITY SEWER TEST | 09/22/2022 | APPROVED | MGIBSON |
| Note: 9/21/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 sewer ran to approximatly where pep tank will be place, C/M NEEDS TO SCHEDULE GRAVITY SEWER INSPECTION | |||
| GRAVITY SEWER TEST | 09/21/2022 | CANCELLED BY APPLICANT | MGIBSON |
| Note: Inspector Notes from Inspection 2060 sewer ran to approximatly where pep tank will be place, C/M NEEDS TO SCHEDULE GRAVITY SEWER INSPECTION | |||
| U - SEWER TIE IN | 09/21/2022 | CANCELLED BY APPLICANT | MGIBSON |
| PEP TANK INSTALLATION REQUEST | 09/12/2022 | APPROVED | CSTONE |
| Note: THIS IS A REINSPECTION ADDED ON 9/2/2022 10:49:51 AM THIS IS A REINSPECTION ADDED ON 8/15/2022 12:07:03 PM THIS IS A REINSPECTION ADDED ON 7/26/2022 2:17:58 PM Exterior (stucco, stone, or siding must be applied) Dumpster in the way Dumpster needs to move | |||
| ELECTRIC - EARLY POWER | 09/06/2022 | APPROVED | JMUNSON |
| Note: THIS IS A REINSPECTION Inspector Notes from Inspection 2170 Emailed FPL @ 2:30 PM Cancelled09/2/2022 | |||
| ELECTRIC - EARLY POWER | 09/02/2022 | CANCELLED BY APPLICANT | TSTAUFFACHER |
| Note: Inspector Notes from Inspection 2170 Emailed FPL @ 2:30 PM Cancelled09/2/2022 | |||
| PEP TANK INSTALLATION REQUEST | 09/02/2022 | Disapproved -FEE REQUIRED | CSTONE |
| Note: THIS IS A REINSPECTION ADDED ON 8/15/2022 12:07:03 PM THIS IS A REINSPECTION ADDED ON 7/26/2022 2:17:58 PM Exterior (stucco, stone, or siding must be applied) Dumpster in the way Dumpster needs to move | |||
| ROW- PRE-APRON (PRE-POUR) | 08/30/2022 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION NEED TO DIG OUT FOOTERS NEED TO HAVE ALL ASPHALT OUT OF POURING AREA CULVERT PIPE NEEDS TO BE BACK FILLED HALF WAY UP ON PIPE NEED TO HAVE THE SWALE DAIGRAM IN PERMIT BOX CULVERT PIPE IS OUT OF TOLERANCE | |||
| ROW- PRE-APRON (PRE-POUR) | 08/15/2022 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: NEED TO DIG OUT FOOTERS NEED TO HAVE ALL ASPHALT OUT OF POURING AREA CULVERT PIPE NEEDS TO BE BACK FILLED HALF WAY UP ON PIPE NEED TO HAVE THE SWALE DAIGRAM IN PERMIT BOX CULVERT PIPE IS OUT OF TOLERANCE | |||
| PEP TANK INSTALLATION REQUEST | 08/15/2022 | Disapproved -FEE REQUIRED | CSTONE |
| Note: THIS IS A REINSPECTION ADDED ON 7/26/2022 2:17:58 PM Exterior (stucco, stone, or siding must be applied) Dumpster in the way | |||
| PEP TANK INSTALLATION REQUEST | 07/26/2022 | Disapproved - NO FEE | CSTONE |
| Note: Exterior (stucco, stone, or siding must be applied) | |||
| LATH/BRICK/ WATER BARRIER | 07/21/2022 | APPROVED - AS NOTED | KSANDOE |
| Note: Inspector Notes from Inspection 2490 The storage area above the garage where spary from has been installed will need to a thermal barrier installed or provide specifications on the rating of the foam. R316.5.3 Attics. The thermal barrier specified in Section R316.4 is not required where all of the following apply: 1. Attic access is required by Section R807.1. 2. The space is entered only for purposes of repairs or maintenance. 3. The foam plastic insulation has been tested in accordance with Section R316.6 or the foam plastic insulation is protected against ignition using one of the following ignition barrier materials: 3.1. 11/2-inch-thick (38 mm) mineral fiber insulation. 3.2. 1/4-inch-thick (6.4 mm) wood structural panels. 3.3. 3/8-inch (9.5 mm) particleboard. 3.4. 1/4-inch (6.4 mm) hardboard. 3.5. 3/8-inch (9.5 mm) gypsum board. 3.6. Corrosion-resistant steel having a base metal thickness of 0.016 inch (0.406 mm). 3.7. 11/2-inch-thick (38 mm) cellulose insulation; or 3.8. 1/4-inch (6.4 mm) fiber-cement panel, soffit or backer board. The ignition barrier is not required where the foam plastic insulation has been tested in accordance with Section R316.6. 7/21/22 Specifications for spray foam have not been provided. | |||
| INSULATION | 07/15/2022 | APPROVED - AS NOTED | JWALKER |
| Note: The storage area above the garage where spary from has been installed will need to a thermal barrier installed or provide specifications on the rating of the foam. R316.5.3 Attics. The thermal barrier specified in Section R316.4 is not required where all of the following apply: 1. Attic access is required by Section R807.1. 2. The space is entered only for purposes of repairs or maintenance. 3. The foam plastic insulation has been tested in accordance with Section R316.6 or the foam plastic insulation is protected against ignition using one of the following ignition barrier materials: 3.1. 11/2-inch-thick (38 mm) mineral fiber insulation. 3.2. 1/4-inch-thick (6.4 mm) wood structural panels. 3.3. 3/8-inch (9.5 mm) particleboard. 3.4. 1/4-inch (6.4 mm) hardboard. 3.5. 3/8-inch (9.5 mm) gypsum board. 3.6. Corrosion-resistant steel having a base metal thickness of 0.016 inch (0.406 mm). 3.7. 11/2-inch-thick (38 mm) cellulose insulation; or 3.8. 1/4-inch (6.4 mm) fiber-cement panel, soffit or backer board. The ignition barrier is not required where the foam plastic insulation has been tested in accordance with Section R316.6. | |||
| INSULATION | 07/14/2022 | CANCELLED BY APPLICANT | WEB |
| ALL ROUGH | 07/12/2022 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION Nail plates missing, Top plate garage wall. dining wall. front entry. Front bed room wall, Check all areas Top of the front arch windows not fastened. Wire not phased out in electical panel. Where the miro wave exhaust vent penentrates the top plate of the kitchen wall strap wall and install fire blocking. | |||
| ALL ROUGH | 07/08/2022 | Disapproved - NO FEE | JWALKER |
| Note: Nail plates missing, Top plate garage wall. dining wall. front entry. Front bed room wall, Check all areas Top of the front arch windows not fastened. Wire not phased out in electical panel. Where the miro wave exhaust vent penentrates the top plate of the kitchen wall strap wall and install fire blocking. | |||
| ALL ROUGH | 07/07/2022 | CANCELLED BY APPLICANT | WEB |
| ROOF VALLEY & METAL | 06/17/2022 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION The synthetic underlayment is to be fastened 6" o.c. at the laps and ends and 12" o.c. in the field. The field nailing is good the nailing needs to be corrected. | |||
| ROOF VALLEY & METAL | 06/03/2022 | Disapproved - NO FEE | JWALKER |
| Note: The synthetic underlayment is to be fastened 6" o.c. at the laps and ends and 12" o.c. in the field. The field nailing is good the nailing needs to be corrected. | |||
| WALL SHEATHING | 06/01/2022 | APPROVED | JWALKER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/01/2022 | APPROVED - AS NOTED | JWALKER |
| Note: Garage wall. Post under the Girder truss calls for a concrete to post base. Detail on page GN of the prints. Check at all rough, | |||
| FOUND SURVEY APPROVED (OFFICE) | 05/31/2022 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 05/09/2022 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1) The front entry area where the walls step up. Rebar pieces have been dropped down the block wall cells and tie to the dowels. To give the appearance of a full down rod. Down rods are to be continous from top of wall to bottom. Highlighted the drawings. Check all down rods in this area. 2) Missing down cell at front entry door right hand side. Missing dowel on right side garage wall. 5/5/22 Above listed corrections have not been fully made. Rebar is to be continuous. The missed dowel at the right side front column was not drilled the required 6" depth and set in epoxy and was easily pulled out, | |||
| TIE BEAM / LINTEL | 05/05/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: THIS IS A REINSPECTION 1) The front entry area where the walls step up. Rebar pieces have been dropped down the block wall cells and tie to the dowels. To give the appearance of a full down rod. Down rods are to be continous from top of wall to bottom. Highlighted the drawings. Check all down rods in this area. 2) Missing down cell at front entry door right hand side. Missing dowel on right side garage wall. 5/5/22 Above listed corrections have not been fully made. Rebar is to be continuous. The missed dowel at the right side front column was not drilled the required 6" depth and set in epoxy and was easily pulled out, | |||
| ELECTRIC TEMP POLE | 05/03/2022 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 2:30 PM | |||
| ELECTRIC TEMP POLE | 04/28/2022 | Disapproved - NO FEE | JWALKER |
| Note: The top GFIC outlet is cracked in half, and needs to be replaced. | |||
| TIE BEAM / LINTEL | 04/27/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 1) The front entry area where the walls step up. Rebar pieces have been dropped down the block wall cells and tie to the dowels. To give the appearance of a full down rod. Down rods are to be continous from top of wall to bottom. Highlighted the drawings. Check all down rods in this area. 2) Missing down cell at front entry door right hand side. Missing dowel on right side garage wall. | |||
| MONOLITHIC SLAB | 03/31/2022 | APPROVED | KSANDOE |
| Note: THIS IS A REINSPECTION 3/30/ FBC SECTION 1907 MINIMUM SLAB PROVISIONS 1907.1 General. The thickness of concrete floor slabs supported directly on the ground shall not be less than 3 1/2 inches. Slab is showing shallow areas of 2" in some locations. (3) test string lines have been left in place for contractors reference. Dig out excess soil, A termite retreat will need to be done due to soil being removed. | |||
| MONOLITHIC SLAB | 03/30/2022 | Disapproved - NO FEE | JWALKER |
| Note: 3/30/ FBC SECTION 1907 MINIMUM SLAB PROVISIONS 1907.1 General. The thickness of concrete floor slabs supported directly on the ground shall not be less than 3 1/2 inches. Slab is showing shallow areas of 2" in some locations. (3) test string lines have been left in place for contractors reference. Dig out excess soil, A termite retreat will need to be done due to soil being removed. | |||
| MONOLITHIC SLAB | 03/28/2022 | CANCELLED BY APPLICANT | JWALKER |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/28/2022 | APPROVED - AS NOTED | MGIBSON |
| Note: sewer ran to approximatly where pep tank will be place, C/M NEEDS TO SCHEDULE GRAVITY SEWER INSPECTION | |||
| WATER METER INSTALLATION REQUEST | 02/23/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 11/09/2022 | 11/09/2022 |
| Note: Marked INFORMATION By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM PLEASE SUBMIT THE CERTIFICATE OF COMPLETION FOR THE TERMITE THIS NOT THE CERTIFICATE. | |||
| ENGIN1 | COMPLETE | 05/31/2022 | 05/31/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/31/2022 | 05/31/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/02/2022 | 02/02/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/02/2022 | 02/03/2022 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/02/2022 | 02/02/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 01/26/2022 | 04/04/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/25/2022 | 01/26/2022 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM 1. Product Approval Specification Sheet clarification per F.S. 553.842: a. FL 474.115- for wood anchors cannot be found on approved listing. Please verify the number. b. FL 5259.1-R33 - for roofing underlayment does not match with the number shown on Roofing Worksheet. Please coordinate and resubmit the correct one to be used. | |||
| CUSVC | COMPLETE | 01/25/2022 | 02/01/2022 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | HOLD | 01/25/2022 | 01/26/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to reference the correct NEC code year. 2. Need to reference the correct FBC year and edition on the note in the garage about the AHU in the attic. | |||
| ENGIN1 | COMPLETE | 01/25/2022 | 01/26/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 01/25/2022 | 01/28/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 01/25/2022 | 01/26/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Duct layout needs to be signed by the AC contractor | |||
| SW1 | COMPLETE | 01/25/2022 | 02/01/2022 |
| Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/25/2022 | 01/26/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/19/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/19/2022 |
| SW ENG REINSPECTION 30 | ¤30.00 | 11/07/2022 |
| UTILITY PEP REINSPECTION | ¤40.00 | 11/07/2022 |
| UTILITY PEP REINSPECTION | ¤40.00 | 11/07/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/07/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/07/2022 |
| SEWER CREDIT | (¤850.00) | 02/04/2022 |
| SEWER INSPECTION | ¤25.00 | 02/04/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 02/04/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 02/04/2022 |
| SITE PLAN 30 | ¤30.00 | 02/04/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 02/04/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 02/04/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤52.92) | 02/04/2022 |
| METER - DEPOSIT | ¤60.00 | 02/04/2022 |
| WATER- TURN ON | ¤25.00 | 02/04/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/04/2022 |
| INSPECTION - RESIDENTIAL | ¤783.75 | 02/04/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤222.30 | 02/04/2022 |
| CONNECTION FEES | ¤1,077.88 | 02/04/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 02/04/2022 |
| IMPACT FEE FIRE | ¤388.65 | 02/04/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 02/04/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 02/04/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 02/04/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 02/04/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 02/04/2022 |
| SURCHARGE FS 533.721 | ¤10.93 | 02/04/2022 |
| SURCHARGE - FS 468.631 | ¤16.40 | 02/04/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 02/04/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 02/04/2022 |
| SW ENG PRE APRON | ¤30.00 | 02/04/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤17,742.07 |